• 제목/요약/키워드: conventional water treatment

검색결과 567건 처리시간 0.026초

MBR technology for textile wastewater treatment: First experience in Bangladesh

  • Saha, Pradip;Hossain, Md. Zakir;Mozumder, Md. Salatul I.;Uddin, Md. Tamez;Islam, Md. Akhtarul;Hoinkis, Jan;Deowan, Shamim A.;Drioli, Enrico;Figoli, Alberto
    • Membrane and Water Treatment
    • /
    • 제5권3호
    • /
    • pp.197-205
    • /
    • 2014
  • For the first time in Bangladesh, a bench scale membrane bioreactor (MBR) unit was tested in treating a textile wastewater in the industry premises of EOS Textile Mills LTD, Dhaka for three months. The performance of the unit was compared with that of the conventional activated sludge treatment plant, which is in operation in the same premises. The COD and BOD removal efficiency of the MBR unit reached to around 90% and 80% respectively in 20 days whereas the removal efficiency of the conventional treatment plant was as low as 40-50% and 38-40% respectively. The outlet COD and the BOD level for the MBR unit remained stable in spite of the fluctuation in the feed value, while the conventional effluent treatment plant (ETP) failed to keep any stabilized level. The performance of the MBR unit was much superior to that of the functional ETP and the water treated by the MBR system can meet disposal standard.

정수처리공정의 침전법을 개선하기 위한 대체공정으로 용존공기부상법(DAF)을 사용할 때 여러조건에 대한 처리효율 비교 (Comparison of Removal Rates of Sedimentation and DAF(Dissolved Air Flotation) for various Different Conditions in Water Treatment)

  • 김미정;이병호
    • 상하수도학회지
    • /
    • 제11권4호
    • /
    • pp.118-125
    • /
    • 1997
  • Conventional sedimentation method has some limitations for turbidity removal in water treatment because drinking water sources are getting polluted. Removal rates of turbidity using DAF and sedimentation process were compared for various water conditions to know whether DAF is effective to improve sedimentation process. Water samples were clay(gravity 2.65) water 100mg/l, H raw water, mixed water of H raw water and clay 100mg/l, and mixed water of HA(Humic Acid) 5mg/l and clay 100mg/l. Other parameters were temperature, coagulants(Alum, $FeCl_3$), and treatment time. Water temperature greatly affected in removal rates of turbidity for sedimentation and DAF. Generally DAF was more effective in removal rates of turbidity than sedimentation at the same experimental condition. Removal rates of $UV_{254}$ were high to over 90%, and independent of temperature and coagulant.

  • PDF

Model based control of filter run time on potable water treatment plant

  • Jusic, Suvada;Milasinovic, Zoran
    • Coupled systems mechanics
    • /
    • 제4권2호
    • /
    • pp.157-172
    • /
    • 2015
  • Control of potable water treatment plant (PWTP) is nowadays based on experience. The aim of this article is to show that model based control of treatment process is more efficient than process operation based on experience. Stimela environment is used for modeling of processes of potable water treatment. Application of the model was conducted on PWTP "Crkvice" in Zenica (BiH). This plant has used conventional rapid sand filters. By effective application of the model it is determined the optimal filter run time for different input turbidity of raw water. This results in the possibility of reducing the consumption of backwashing water, lower costs for its pumping and reducing the amount of coagulants. In the existing practice, based on experience, these benefits are not used.

정수처리 과정에서의 중금속제거에 관한 연구 (Removal of Heavy Metals Through Conventional Water Treatment Processes)

  • 김중구;고영송;남상호
    • 한국환경보건학회지
    • /
    • 제20권4호
    • /
    • pp.36-44
    • /
    • 1994
  • A study was carried out in order to investigate the removal efficiencies and removal characteristics of heaw metals such as Pb, Cd, Cr, Cu in raw water by one of conventional water treatment processes. The coagulants used in this study were Alum and PAC. Three kinds of water samples were provided: kaolin water, kaolin water mixed with humic acid and raw water from Han River mixed with suspended matter deposited on raw water inlet pipe. Heaw metals were added to the water samples with their respective turbidity, and jar tests were performed. In the results from heaw metal removal studies, lead might be adsorbed or exchanged on the particle surface (SS) rather than react with organic matter added. Cadmium was affected on the dissolved organic matter. Chromium was affected by the both dissolved organic matter and SS concentration, and the restabilization and the enmeshment appeared at moderate (50~80 NTU) and high (100 NTU) turbidity as defined in this experimenL The removal efficiency of copper was relatively little affected by the dissolved organic matter but by SS concentration in comparison with other heavy metals. In these studies as to the raw water turbidities and concentration of heaw metals, it is proved out that the removal efficiency on heaw metals in both cases of PAC and Alum as coagulants was not significantly different.

  • PDF

용존공기 부상법(Disssolved Air Flotation)을 이용한 정수처리 (Water Treatment Using DAF(Disssolved Air Flotation))

  • 이병호;김재훈
    • 상하수도학회지
    • /
    • 제10권2호
    • /
    • pp.80-87
    • /
    • 1996
  • Treatment efficiencies of water quality parameters such as $KMnO_4$ Demand, $UV_{254}$, Turbidity, and LAS(Linear Alkyl Sulfonate) were compared between DAF(Dissolved Air Flotation) and CGS(Conventional Gravitational Sedimentation). The experimental results showed that DAF is much more efficient in treatment of water quality parameters than CGS. The optimum pH was about 7, and optimum alum($Al_2(SO_4)_3$) dose was about 30 ppm for DAF treatment. Economic aspects were also analyzed for bath systems. Even though production cost per ton of drinking water is slightly higher in DAF than in CGS, it turned out that construction cost and land value of CGS far surpass the production cost. DAF system is superior in removal efficiency of impurities and in production cost as a whole to CGS system.

  • PDF

Towards a novel approach to improve drinking water quality at Dhaka, Bangladesh

  • Serajuddin, Md.;Chowdhury, Md. Aktarul Islam
    • Environmental Engineering Research
    • /
    • 제23권2호
    • /
    • pp.136-142
    • /
    • 2018
  • The river water source of Saidabad Surface Water Treatment Plant at Dhaka, Bangladesh, is deteriorated too much to be treated by conventional treatment process due to excessive ammonia pollution. In order to improve the raw water quality before it enters into the main treatment chain, a pilot study was conducted for pre-treatment of the raw water. The objective is to investigate the rate of reduction of ammonia using the Meteor pilot, a biological pretreatment system, which is a laboratory scale Moving Bed Biofilm Reactor with a nominal volume of hundred liters, filled with 50 L of Meteor 660 media. The reduction of ammonia was quite significant on average 73%, while the reduction of COD was in a range from 20 to 60%. The Meteor pilot was able to treat and nitrify the raw water and produce an effluent that respects the guarantee of ammonia < $4.0mg\;NH_3-N/L$ when the raw water ammonia concentration was < $15mg\;NH_3-N/L$. The study identified operating parameters necessary to achieve the desired goal of adequate ammonia removal. The study results would benefit a range of systems across the country by providing guidance on the design and operation of a biological pre-treatment system for ammonia removal.

효과적 공간활용을 위한 Side Stream Plug-Flow Reactor를 이용한 하수 고도처리 공정 적용에 관한 연구 (A study on Applicable to Advanced treatment of using Side Stream Plug-Flow Reactor)

  • 김삼주;현인환;독고석
    • 상하수도학회지
    • /
    • 제22권3호
    • /
    • pp.367-372
    • /
    • 2008
  • This study configured the conventional $A^2O$ (Anaerobic-Anoxic-Aerobic bioreactor) system which the fixed media immersed into the anoxic reactor(Named PFR system : Plug Flow Reactor) for evaluating the removal efficiency of nitrogen in the wastewater. The experimental equipment was a cylinder which was consist of 4 pleated PE Pipes(Length 330M, Diameter 100mm) including 2 rope shape media. As a result, the average effluent T-N removal efficiency of the conventional $A^2O$ system was 17.9, 40.3, 50.6, 44.6% in each mode, but the average effluent T-N removal efficiency of the PFR system could achieve 38.8, 57.1, 71.8, 65.4% in each mode. It indicated that the PFR system caused to the increasing of C/N ratio that effected to the increasing of the denitrification efficiency. Not only the effective T-N removal efficiency but also the controllable install space will give advantages for retrofitting of the wastewater treatment plant with the conventional treatment system to the PFR system.

진동막 분리장치를 이용한 제지폐수의 재이용에 관한 연구 (A study on the pulp and paper mills waste water Recycling by VSEP membrane system)

  • 지은상;김재우;신대윤
    • 환경위생공학
    • /
    • 제16권1호
    • /
    • pp.40-46
    • /
    • 2001
  • Conventional membrane systems was difficult to treatment for pulp and paper mills waste warter. Technological advances in membrane filtration systems have created opportunity for pulp and paper mills to treat effluent streams in order to meet stricter environmental constraints. "Vibratory Shear Enhanced Processing(VSEP)" developed by new logic international makes if possible to filter effluent streams without the fouling problems exhibited by conventional membrane systems. Various kinds of waste water occurred to and paper mills experiment with "VSEP" set up conventional membrane. The results were as followes : Excepting ultra filter($0.1{\mu}\textrm{m}$ Teflon, C-100, G-50), Nano filter(NTR-7450, DS-5, PVD-1) and reverse osmosis(ACM-4) was treated with very excellent weight of treatment, electric conductivity, removal COD, TDS, turbidity.

  • PDF

특허 및 논문 게재 분석을 통한 수처리용 분리막의 연구동향 (Research Trend of Membrane for Water Treatment by Analysis of Patent and Papers Publication)

  • 우창화
    • 공업화학
    • /
    • 제28권4호
    • /
    • pp.410-419
    • /
    • 2017
  • 지구온난화, 환경오염, 가뭄 등의 재해현상으로 인한 물 부족 현상이 진행됨에 따라 수자원의 활용성을 증가시키기 위한 원천기술의 개발과 연구들이 진행되고 있다. 그중 수처리 분리막 기술은 기존 물리화학적 및 생물학적 공정보다 수질 개선 효과가 우수하고 약품 사용이 배제된 환경친화적인 공정이다. 수처리 분리막은 오폐수처리, 정수처리, 해수담수처리, 이온교환 공정, 초순수 제조, 유기용매 분리 등 다양한 분야에 적용되며 분리막을 이용한 수처리 기술은 점차 응용 범위가 넓어지고 있는 추세이다. 수처리 분리막의 핵심 기술은 분리성능을 조절하기 위한 기공 사이즈를 조절하는 것으로써 더 나은 성능을 나타내는 분리막을 개발하기 위한 연구가 활발히 진행되고 있다. 본 총설에서는 수처리용 분리막의 특허 및 논문의 기술경쟁력 평가를 통하여 국가별, 기관별 발표 빈도수를 정리하였으며, 오폐수처리용 분리막, 정수처리용 분리막, 해수담수화용 분리막, 그리고 이온교환공정용 분리막에 대한 평가를 진행하고, 향후 연구 방향에 대하여 제시해 보고자 한다.

재래식 정수처리공정에서 조류입자 제거를 위한 DAF Hybrid 공정의 실험적 적용과 입자특성 변화 (Experimental Application of DAF Hybrid Process to Remove Algae Particles for Conventional Water Treatment Processes and Change of Particle Characteristics)

  • 곽동희;유승준
    • Korean Chemical Engineering Research
    • /
    • 제46권3호
    • /
    • pp.516-520
    • /
    • 2008
  • 우리나라는 상수도시설의 노후화와 그 동안의 상수원 수질변화에 대응한 정수처리공정의 개량과 개선이 요구되어지고 있는 상황에 있어서, 기존의 정수처리공정에 어떠한 시설개량이나 설비의 보완 없이 DAF 공정을 추가하여 점토와 조류입자를 효과적으로 제거할 수 있는 DAF hybrid 공정의 적용성을 살펴보고자 일련의 실험을 실시하였다. DAF 공정의 설치위치는 조류입자의 제거에는 응집지나 침전지 전단을 이용하는 DAF-CGS 공정조합보다는 침전지 후단 또는 여과지 전단을 이용하는 DAF-CSF 방식이 더 효과적인 것으로 나타났다. 또한, DAF-CSF hybrid 공정을 도입함으로써 기존의 상수처리조건과 동일한 처리속도(수리학적 부하량)에서 처리효율이 향상될 것이며, 높은 수리학적 부하에서도 재래식 상수도시설에 적용하여 안정된 처리효율을 얻을 수 있을 것으로 판단되었다.