• Title/Summary/Keyword: conventional medicine

Search Result 2,758, Processing Time 0.042 seconds

Multi-tracer Imaging of a Compton Camera (다중 추적자 영상을 위한 컴프턴 카메라)

  • Kim, Soo Mee
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.18-27
    • /
    • 2015
  • Since a Compton camera has high detection sensitivity due to electronic collimation and a good energy resolution, it is a potential imaging system for nuclear medicine. In this study, we investigated the feasibility of a Compton camera for multi-tracer imaging and proposed a rotating Compton camera to satisfy Orlov's condition for 3D imaging. Two software phantoms of 140 and 511 keV radiation sources were used for Monte-Carlo simulation and then the simulation data were reconstructed by listmode ordered subset expectation maximization to evaluate the capability of multi-tracer imaging in a Compton camera. And the Compton camera rotating around the object was proposed and tested with different rotation angle steps for improving the limited coverage of the fixed conventional Compton camera over the field-of-view in terms of histogram of angles in spherical coordinates. The simulation data showed the separate 140 and 511 keV images from simultaneous multi-tracer detection in both 2D and 3D imaging and the number of valid projection lines on the conical surfaces was inversely proportional to the decrease of rotation angle. Considering computation load and proper number of projection lines on the conical surface, the rotation angle of 30 degree was sufficient for 3D imaging of the Compton camera in terms of 26 min of computation time and 5 million of detected event number and the increased detection time can be solved with multiple Compton camera system. The Compton camera proposed in this study can be effective system for multi-tracer imaging and is a potential system for development of various disease diagnosis and therapy approaches.

A Projection-based Intensity Correction Method of Phased-Array Coil Images (위상 배열 코일 영상에서의 밝기 비균등성을 projection에 기반하여 수정하는 방법)

  • Yun SungDae;Chung Jun-Young;Han YeJi;Park HyunWook
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.1
    • /
    • pp.36-42
    • /
    • 2005
  • Purpose : To develop a novel approach to calculate the sensitivity profiles of the phased array coil for use in non-uniform intensity correction. Materials and Methods : The proposed intensity correction method estimates the sensitivity profile of the coil to extract intensity variations that represent the scanned image. The sensitivity profile is estimated by fitting a non-linear curve to various angles of projections through the imaged object in order to eliminate the high-frequency image content. Filtered back projection is then used to compute the estimates of the sensitivity profile of each coil. The method was applied both to phantom and brain images from 8-channel phased-array coil and 4-channel phased-array coil, respectively. Results : Intensity-corrected images from the proposed method have more uniform intensity than those from the commonly used 'sum-of-squares' approach. By using the proposed correction method, the intensity variation was reduced to $6.1\%$ from $13.1\%$, acquired from the 'sum-of-squares'. Conclusion : The proposed method is more effective at correcting the intensity non-uniformity of the phased-array surface-coil images than the conventional 'sum-of-squares' method.

  • PDF

Diffus ion-Weighted MR Imaging of Spinal Cord Infarction (척수경색의 확산강조자기공명영상)

  • 김윤정;서정진;임남열;정태웅;김윤현;박진균;정광우;강형근
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.2
    • /
    • pp.166-172
    • /
    • 2002
  • Purpose : To evaluate the usefulness of diffusion-weighted imaging(DWI) and quantitative apparent diffusion coefficient (ADC) maps in the patients with spinal cord infarction. Materials and methods : We studied 6 patients presented symptoms with spinal cord infarction, retrospectively (3 men and 3 women). We obtained multi-shot echo planar-based, DWI using 1.5T MR scanner at 5.4 mean days after the onset of ischemic symptoms. In six patients, signal intensity was acquired at conventional b value $1000s/\textrm{mm}^2$). The ADC value for the normal spinal cord and for infarcted lesions was measured from the trace ADC maps by using regions of interest positioned over the spinal cord. We analyzed signal intensity of lesion on MRI and DWI, and compared with ADC values in infarcted lesions and normal site. Results : T1-weighted MR image showed isosignal intensity in four of six patients and low signal intensity in two of six. T2-weighted MR image demonstrated high signal intensity in all of six. All DWI were considered to be diagnostic. All of six depicted a bright signal intensity on DWI. ADC values of infarcted lesion were measured lower than that of normal spinal cord on ADC map. The differences in ADC values between infarcted and normal spinal cord were significantly different (p<0.05). Conclusion : It is possible to obtain DWI and ADC map of the spinal cord and DWI may be useful in the early diagnosis and localization of lesion site in patients with spinal cord infarction.

  • PDF

Magnetic Resonance Elastography (자기 공명 탄성법)

  • Kim, Dong-Hyun;Yang, Jae-Won;Kim, Myeong-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.1
    • /
    • pp.10-19
    • /
    • 2007
  • Conventional MRI methods using T1-, T2-, diffusion-, perfusion-weighting, and functional imaging rely on characterizing the physical and functional properties of the tissue. In this review, we introduce an imaging modality based on measured the mechanical properties of soft tissue, namely magnetic resonance elastography (MRE). The use of palpation to identify the stiffness of tissue remains a fundamental diagnostic tool. MRE can quantify the stiffness of the tissue thereby providing a objective means to measure the mechanical properties. To accomplish a successful clinical setting using MRE, hardware and software techniques in the area of transducer, pulse sequence, and imaging processing algorithm need to be developed. Transducer, a mechanical vibrator, is the core of MRE application to make wave propagate invivo. For this reason, considerations of the frame of human body, pressure and friction of the interface, and high magnetic field of a MRI system needs to be taken into account when designing a transducer. Given that the wave propagates through human body effectively, developing an appropriate pulse sequence is another important issue in obtaining an optimal image. In this review paper, we introduce the technical aspects needed for MRE experiments and introduce several applications of this new field.

  • PDF

Antibiofilm Activity of Scutellaria baicalensis through the Inhibition of Synthesis of the Cell Wall (1, 3)-${\beta}$-D-Glucan Polymer (세포벽 (1,3)-${\beta}$-D-Glucan Polymer 합성의 저해로 인한 황금(Scutellaria baicalensis)의 항바이오필름 활성)

  • Kim, Younhee
    • Microbiology and Biotechnology Letters
    • /
    • v.41 no.1
    • /
    • pp.88-95
    • /
    • 2013
  • Candida biofilms are self-organized microbial communities growing on the surfaces of host tissues and medical devices. These biofilms have been displaying increasing resistance against conventional antifungal agents. The roots of Scutellaria baicalensis have been widely used for medicinal purpose throughout East Asia. The aim of the present study was to evaluate the effect of S. baicalensis aqueous extract upon the preformed biofilms of 10 clinical C. albicans isolates, and assess the mechanism of the antibiofilm activity. Its effect on preformed biofilm was judged using an XTT reduction assay and the metabolic activity of all tested strains were reduced ($57.7{\pm}17.3$%) at MIC values. The S. baicalenis extract inhibited (1, 3)-${\beta}$-D-glucan synthase activity. The effect of S. baicalensis on the morphology of C. albicans was related to the changes in growth caused by inhibiting glucan synthesis; most cells were round and swollen, and cell walls were densely stained or ruptured. The anticandidal activity was fungicidal, and the extract also arrested C. albicans cells at $G_0/G_1$. The data suggest that S. baicalensis has multiple fatal effects on target fungi, which ultimately result in cell wall disruption and killing by inhibiting (1, 3)-${\beta}$-D-glucan synthesis. Therefore, S. baicalensis holds great promise for use in treating and eliminating biofilm-associated Candida infections.

Radiation Therapy In Management Of Primary Non-Hodgkin's Lymphoma Of Central Nervous System (원발성 중추신경계 림프종에 대한 방사선치료)

  • Hong, Seong-Eon
    • Radiation Oncology Journal
    • /
    • v.12 no.1
    • /
    • pp.33-42
    • /
    • 1994
  • From 1982 to 1991, sixteen Patients with primary non-Hodgkin's lymphoma of the central nervous system(CNS) were seen at Kyung Hee University Hospital. The most common subtypes were large, noncleaved cell lymphoma and immunoblastic lymphoma of B cells. Lesions most commonly involved were the parietal lobes and/or deep nuclei. Positive cerebrospinal fluid cytology was rare at initial presentation. Sixteen patients were treated with surgical biopsy or resection followed by whole brain radiotherapy at a median dose of 40 Gy(range=30-50 Gy) with variable boost doses. Of 16 patients who underwent surgery and postoperative radiotherapy, fourteen patients died between 2 and 49 months following treatment, and two are alive with no evidence of disease at 8 and 22 months. The 1-and 2-year survival rates were 55.6$ \% $ and 34.7$ \% $, respectively with 12 months of median survival. Patterns of failure were analyzed in eleven patients of total 16 patients. Failure at the original site of involvement was uncommon after radiotherapy treatment. In contrast, failure in the brain at sites other than those originally invovled was common in spite of the use of whole brain irradiation. Failure occurred in the brain 11/16(68.7$ \% $), in spinal axis 4/16(25.0$ \% $). The age, sex, location of involvement within CNS, numbers of lesion, or radiation dose did not influence on survival. The authors conclude that Primary CNS lymphoma is a locally aggressive disease that is poorly controlled with conventional radiation therapy. The limitation of current therapy for this disease are discussed, and certain promising modality should be made in regarding the management of future patients with this disease.

  • PDF

A Study on the Non-Toxic Compound-based Multi-layered Radiation Shielding Sheet and Improvement of Properties (무독성 화합물 기반의 다층 구조 방사선 차폐 시트 개발과 특성 개선에 관한 연구)

  • Heo, Ye Ji;Yang, Seung u;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.149-155
    • /
    • 2020
  • Most of radiation protection clothing is made of lead with excellent radiation shielding because it has excellent process ability and economic efficiency and has a high atomic number. However, lead is classified as a hazardous heavy metal, and there is a risk of lead poisoning. Recently, research to replace lead has been actively conducted. In this study, a research on a shielding sheet with improved physical properties while maintaining the radiation shielding ability equivalent to that of conventional materials by mixing two materials that are harmless to the human body, such as BaSO4 and Bi2O3, and a silicone material binder Was performed. For comparison evaluation with the existing lead shielding sheet, the shielding rate was evaluated using a 40 degree shielding sheet having the highest porosity. As a result, it was analyzed that the shielding rate was superior to 9 % or more at the same thickness. In addition, as a result of studies to improve the physical properties of the shielding sheet, it was analyzed that the shielding sheet mixed with BaSO4/nylon/Bi2O3 was the best.

Serodiagnosis of cysticercosis by ELISA-inhibition test using monoclonal antibodies (단세포군항체를 이용한 효소면역억제측정 법에 의한 유구낭미충증의 혈청학적 진단)

  • 용태순;여인석
    • Parasites, Hosts and Diseases
    • /
    • v.31 no.2
    • /
    • pp.149-156
    • /
    • 1993
  • Monoclonal antibodies (Mabs) were produced against crude scolex extract of T solium metacestodes, and applied to ELISA-inhibition test for improving the specificity of serodiagnosis of human cysticercosis. Four hybridomas secreting species-specific anti- cysticercal Mabs (Cya-1, Cya-7, Cya-28 and Cya-31) were selected. Each Mab reacted on antigenic components of 25.5 kDa (Cya-1), 28 kDa (rcya-7), 87.5 kDa (Cya-281), and 12.5 kDa (Cya-31). IFA showed that Cya-1 was located at the calcium corpuscles, and Cya-7 at the loose connective tissue of T soLium metacestode scolex. Cya-28 and Cya-31 reacted on the tegument of the scolex. By conventional ELISA, 23 out of 28 (82.1%) cysticercosis patients were found serologically positive, but 1 out of 9 (11.1%) sparganosls cases and 6 out of 31 (19.4%) paragonlmiasis cases showed false positives. By ELISA-Inhibition test using species-specific anti-cysticercal Mab Cya-7, 19 out of 28 (67.9%) cystlcercosis cases were found serologically positive, but there were no false positives In other parasitic infections.

  • PDF

Usefulness of the Neutrophil Gelatinase-Associated Lipocalin (NGAL) Kit for Acute Kidney Injury Patients at the Emergency Medical Center in Daegu (대구지역 응급의료센터에 내원한 급성 콩팥손상 환자의 진단을 위한 호중구 젤라티나제 관련 리포칼린 키트의 유용성)

  • Lee, Seung-Jin;Park, Sangwook
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.2
    • /
    • pp.49-53
    • /
    • 2016
  • Acute kidney injury (AKI) is a common syndrome resulting in kidney damage and malfunction within a few days or even a few hours. The diagnosis of AKI depends on routine biochemical tests, including serum creatinine, aspartate aminotransferase (AST), alanine aminotransaminase (ALT), blood urea nitrogen (BUN), and electrolytes. Plasma neutrophil gelatinase-associated lipocalin (NGAL) is a biomarker that shows correlation with the severity of acute infections and kidney injuries. The predictive value in other conventional assays for kidney functions has been reported to cause distraction for AKI syndrome. The aim of this study is to verify the predictive value of plasma NGAL in patients with established AKI. The NGAL kit for checkup demonstrates sensitivity of ${\geq}300$ (92.2%), ${\geq}200$ (95.6%), ${\geq}100$ (99.6%), specificity of ${\geq}300$ (95.1%), ${\geq}200$ (97.3%), ${\geq}100$ (99.4%), positive predictability of ${\geq}300$ (93.3%), ${\geq}200$ (93.4%), ${\geq}100$ (99.2%), and negative predictability of ${\geq}300$ (96.7%), ${\geq}200$ (97.7%), ${\geq}100$ (98.1%), respectively. The plasma NGAL compared with the enzyme-linked immunosorbent assay (ELISA) has been shown to be an early predictive biomarker of AKI. The NGAL kit, recently developed for point-of-care of plasma specimens, is thought to be a useful and reliable biomarker for the early diagnosis of decreased kidney functions.

Characterization of proteases of Toxoplasma gondii (Toxoplasma gondii에서 단백질 분해 효소의 특징)

  • Choe, Won-Yeong;Nam, Ho-U;Yun, Ji-Hye
    • Parasites, Hosts and Diseases
    • /
    • v.27 no.3
    • /
    • pp.161-170
    • /
    • 1989
  • The proteases of Toxoplasma gcndii were purified partially and characterisrd for some biochemical properties including various chromatographic patterns, major catalytic classes, and conditions to promote the activity of these enzymes. When Toxoplasma extract was incubated with 3H-casein at various pH, peak hydrolysis of casein was observed at pH 6.0 and at pH 8.5. Proteasfs working at pH 6.0 and at pH 8.5 were purified partially by conventional methods of chromatographies of DE52 anion rxchange, Sephadex G-200 gel permeation, and hydroxylapatite chromatography. Partially purified enzymes were tested by site-specific inhibitors and promotorf. The protease working at pH 6.0 was inactivated by iodoacetamide with LDso of 10-5 M and promoted by dithiothreitol, while the protease working at pH 8.5 was inhibited by phenylmethylsulfonyl fluoride with LD50 of 10-5 M and was Promoted by ATP (excess ATP beyond 2 mM inhibited the activity reversely). The protease of pH 8.5 had the activity of ATPase which might exert the energy to its action. Therefore the former was referred to as a cysteinyl acid protease and the latter, ATP-dependent neutral serine protease.

  • PDF