냉매 가열식 대용량 VRF 히트펌프 사이클 설계를 통한 극한랭지 난방 성능 평가 (Heating Performance Evaluation of the VRF Heat Pump System with Refrigerant Heating Cycle for the Extreme Cold Region)

  • 이상헌;최송;김병순;이재근;이광호
    • 설비공학논문집
    • /
    • 제23권8호
    • /
    • pp.571-579
    • /
    • 2011
  • Heat pump systems for commercial building with variable refrigerant flow(VRF) are expanding a market due to high energy efficiency, lower maintenance cost and easy installation comparing with the conventional heat pump with the constant refrigerant flow. In general, heat pump systems degrade the energy efficiency in the extremely low temperature regions. In this study, VRF heat pump system with refrigerant heating is experimentally investigated to overcome the low heating performance in the extremely low temperature regions. VRF heat pump system with refrigerant heating is found out the sufficient heating performance in the -25 degree temperature condition comparing with the conventional heat pump system and is obtained more than 2,500 kPa high pressure in the evaporator at low temperature.

옴가열이 전분의 레올로지 특성에 미치는 영향 (Effect of Ohmic Heating on Rheological Property of Starches)

  • 차윤환
    • 한국식품영양학회지
    • /
    • 제32권4호
    • /
    • pp.304-311
    • /
    • 2019
  • Ohmic heating is a heating method based on the principle when an electrical current passes through food. Since this method is internal, electrical current damage occurred during heating treatment. The results of ohmic heated starch's external structure, X-ray diffraction, DSC analysis and RVA were differed from those of conventional heating at the same temperature. Several starches changed more rigid by structure re-aggregation. This change in starch was caused by change of physical, chemical, rheological property. The rheology of ohmic heated potato and corn starch of different heated methods were compared with chemically modified starch. After gelatinization, sample starch suspension (2%, 3%) measured flow curves by rheometer. Cross-linked chemically modified starch's shear stress was decreased with degree of substitution reversibly. Ohmic heated more dramatic, at $60^{\circ}C$. Potato starch's shear stress was less than commercial high cross-linked modified starch. Flow curves of potato starches measured at $4^{\circ}C$, $10^{\circ}C$, $20^{\circ}C$. Showed that Ohmic heated potato starch's shear stress ranging between $4^{\circ}C$ and $20^{\circ}C$ was narrower than modified starch. According to this study, ohmic heated potato starch can be used by decreasing viscosity agent like cross-linked modified starch.

석탄회로부터 제올라이트 A의 합성 (Synthesis of Zeolite A from Coal Fly Ash)

  • 지정대;최고열
    • 공업화학
    • /
    • 제22권2호
    • /
    • pp.214-218
    • /
    • 2011
  • 마이크로파 가열 방법과 기존의 가열 방법을 이용하여 석탄회로부터 제올라이트 A를 합성하였다. 반응시간, sodium aluminate의 양, 반응 온도 등이 제올라이트 A의 결정화에 미치는 영향에 대해 연구하였다. $80{\sim}100^{\circ}C$의 범위에서 제올라이트 A의 합성에 필요한 반응 시간은 3~6 h이었으며, 6 h 이상이 되면 결정화도가 오히려 감소하였다. 제올라이트 A의 합성에 필요한 sodium aluminate의 양은 $90^{\circ}C$ 이상에서는 합성용액의 $SiO_2/Al_2O_3$의 비가 0.44~1.05에서 최적이었으며, $80^{\circ}C$에서는 더 많은 양이 필요하였다. 마이크로파 가열 방법은 기존의 가열 방법에 비해 초기 결정화 속도는 약간 증가하였으나, 충분히 결정화되는데 필요한 반응시간은 서로 비슷하였다. 따라서 마이크로파 가열에 의한 석탄회로부터 제올라이트 A의 합성에 미치는 영향은 크지 않다는 것을 알 수 있었다.

마이크로파 진공가열방법이 효소의 불활성화에 미치는 영향 (Effect of Microwave Vacuum Heating on Inactivation of Enzymes)

  • 문은경;한기영;김석신;김상용;노봉수
    • 한국식품과학회지
    • /
    • 제29권2호
    • /
    • pp.284-291
    • /
    • 1997
  • 식품의 저장과 가공과정에서 품질을 저해시키는 바람직하지 못한 효소를 불활성화시키기 위하여 식품을 살균시키는 경우 고온에서 가열처리하게 되면 다른 성분들이 파괴될 우려가 있다. 따라서 열에 의한 영양파괴를 최소화 하기 위해 감압상태에서 마이크로파를 이용하여 저온에서 가열처리하는 방법을 사용하였다. 이 가열방법을 사용하여 ${\alpha}-amylase$${\beta}-amylase,\;glucoamylase,\;peroxidase$의 열불활성화를 측정하였고 이를 기존의 가열방법과 비교하였다. $60^{\circ}C$에서 기존의 방법으로 가열했을 경우와 260 mmHg의 감압상태하에서 microwave (출력버튼 1)를 이용하여 가열했을 경우 비타민 C 파괴 정도는 거의 같았다. 이와같은 조건에서 ${\alpha}-amylase$${\beta}-amylase$의 불활성화를 조사하였으며 초기에는 lag time의 영향으로 기존의 방법에 비해 잔존활성이 많이 남아 있었으나 완전히 실활되는데 걸리는 시간은 마이크로파 진공가열방법을 이용한 경우가 더 짧았다. 또한 $75^{\circ}C$에서 기존의 열처리 방법으로 했을 경우와 360 mmHg의 감압상태에서 microwave (출력버튼 2)를 이용하여 가열했을 경우 비타민 C 파괴정도가 거의 같았는데 이와 같은 조건에서 glucoamylase와 peroxidase의 불활성화를 조사하였으며 실활되는데 걸리는 시간은 이 경우에도 마이크로파 진공가열 방법을 이용한 경우가 더 짧았다. 저온에서 마이크로파 진공가열 방법에 의해 효소를 불활성화 시키는 가열조건을 얻었다.

  • PDF

카본블랙/나일론 66 혼합 나노섬유웹의 마이크로파에 의한 접착거동 (Bonding Behavior of Carbon Black/Nylon 66 Hybrid Nanofiber Webs via Microwave Heating)

  • Shin, Dong-Ho;Joo, Chang-Whan
    • 한국섬유공학회:학술대회논문집
    • /
    • 한국섬유공학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.114-117
    • /
    • 2003
  • Conventional heating the heat source cause the molecules to react from the surface toward the center so that successive layers of molecules heat in turn. The product surfaces may be in danger of over heating by the time heat penetrates the material. Microwave, however, produce a volume heating effect. All molecules are set in action at the same time. It also evens temperature gradients and offers other important benefits such as selective heating. (omitted)

  • PDF

Effects of Temperature Coefficients for Dielectric Constants on Thermoreflectances and Thermal Responses of Metal Thin Films Exposed to Ultrashort Pulse Laser Beams

  • Seungho Park
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권1호
    • /
    • pp.1-9
    • /
    • 2002
  • Effects of temperature coefficients fur dielectric constants on transient reflectances and thermal responses have been investigated for a metal(gold) thin-film during ultrashort pulse laser heating. Heating processes are simulated using the conventional conduction model(parabolic one-step, POS), the parabolic tow-step model(PTS), the hyperbolic two-step model(HTS). Results fro the HTS model are very similar to those from the PTS model, since the laser heating time in this study is considerably greater than the electron relaxation time. PTS and HTS models, however, result in completely different temperature profiles from those obtained by the POS model due to slow electron-lattice interactions compared to laser pulse duration. Transient reflectances are directly estimated from the linear relationship between electron temperature and complex dielectric constants, while conventional approaches assume that the change in reflectances is proportional to that in temperatuer. Reflectances at the front surface vary considerably for various dielectric constants, while those at the rear surface remain unchanged relatively.

페리미터존의 에어배리어 공조방식에 따른 실내 열환경 평가 (Evaluation of Indoor Thermal Environment According to Air-Barrier Air Conditioning System in Perimeter Zone)

  • 박병윤;함흥돈;손장열
    • 설비공학논문집
    • /
    • 제17권4호
    • /
    • pp.370-376
    • /
    • 2005
  • For the purpose of investigating the effective removal of heating/cooling load from light-weighted building envelope, two air-conditioning systems, conventional parameter air-conditioning system and air-barrier system, are evaluated and compared by both experiment and simulation with six different cases during heating and cooling season. In addition, the characteristics of window-side building thermal load are assessed by varying supply air velocity in order to seek the optimal system operation condition. The results are as follows. 1) Air-barrier system is more effective to remove heating/cooling load at perimeter zone than conventional parameter air-conditioning system. Moreover, the better effectiveness appears during cooling season than during heating season. 2) The experiment during cooling season provides that indoor temperature of air-barrier system shows $1^{\circ}C$ less than that of the conventional system with similar outdoor air temperature profile, and indoor temperature distribution is more uniform throughout the experimented model space. It concludes that air-barrier system can achieve energy saving comparing to the conventional system. 3) The capturing efficiency of air-barrier system is 0.47 on heating season and 0.2 on cooling season with the same supply air volume. It results that the system performs effectively to remove building thermal load, moreover demonstrates high efficiency during cooling season. 4) The simulation results provide that capturing efficiency to evaluate the effective removal of building load from perimeter zone shows high value when supply air velocity is 1 m/s.

Selective Crystallization of SAPO-5 and SAPO-34 Molecular Sieves in Alkaline Condition: Effect of Heating Method

  • Yoon, Ji-Woong;Jhung, Sung-Hwa;Kim, Young-Ho;Park, Sang-Eon;Chang, Jong-San
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권4호
    • /
    • pp.558-562
    • /
    • 2005
  • Crystallization of SAPO-5 and SAPO-34 molecular sieves with microwave and conventional electric heating of the same gel has been investigated in an alkaline condition using N,N,N’N’tetraethylethylenediamine as a template molecule. SAPO-5 structure can be selectively prepared with microwave heating because of the fast crystallization of the technique. On the other hand, SAPO-34 is the sole product with usual conventional electric heating because SAPO-5 can be gradually transformed into SAPO-34 structure with an increase in crystallization time. This phase selectivity is probably because of the relative stability of the two phases at the reaction conditions (kinetic effect). Crystallization with microwave heating can be suggested as a phase selective synthesis method for relatively unstable materials because of fast crystallization.

2단 승온 캐스케이드 히트펌프의 성능 특성에 관한 연구 (Study on the Performance of a Cascade Heat Pump with Two-stage Water Heating Process)

  • 장한별;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제12권4호
    • /
    • pp.27-32
    • /
    • 2016
  • It is estimated that only heating and cooling take about one third of the total energy consumption worldwide. However, the conventional heating and cooling systems have low efficiencies. Also, boilers and electric heaters that are mostly used to generate both domestic and industrial hot water are inefficient and high energy consumers. For this reason, cascade heat pumps which are known to be very energy efficient and have less environmental impact are being promoted to replace conventional heating, cooling and hot water systems. In this study, a newly designed cascade heat pump by two-stage water heating method has been experimentally investigated. By adopting the auxiliary heat exchanger, the performance of the system was increased. The performance enhancement rate of the system could be maximized by adjusting the low stage compressor speed rather than the high stage compressor speed. The performance of the system with the auxiliary heat exchanger was enhanced by 16.5%.

지역난방의 일반제어 및 열량제어 에너지 시뮬레이션 (Energy Simulation for Conventional and Thermal-Load Controls in District Heating)

  • 이성욱;홍희기;조성환
    • 설비공학논문집
    • /
    • 제27권1호
    • /
    • pp.50-56
    • /
    • 2015
  • Korea district heating systems have mainly used setting temperature control and outdoor reset control. Different from such conventional normal methods, a thermal-load control proposed in Sweden can decrease the return temperature and reduce pump power consumptions because the control is able to provide the appropriate amount of required heat. In this study, further improved predictive optimal control in addition to the conventional controls were simulated in order to verify its effect in district heating system using TRNSYS 17. $200m^2$ apartment housing which accounts for 25% in Korea and is used as a calculation model;. the number of households in the simulation was 9. As a result, a higher temperature difference and decreasing flow rate at primary loop were shown when using thermal-load control.