• Title/Summary/Keyword: conventional cytology

Search Result 54, Processing Time 0.028 seconds

Comparison of Liquid-based Cytology and Conventional Smear in the Evaluation of Sputum Cytology

  • Back, Oun-Cheol
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.45 no.1
    • /
    • pp.26-31
    • /
    • 2013
  • The cytology of sputum specimens, at a medical facility in Korea, is using the liquid-based cytology and conventional smear method. It confirms the diagnosis using conventional smear methods and the liquid-based cytology. In addition, the diagnosis uses two kinds of each method, compares the suitability, sensitivity and specificity for each test and tries to understand the efficient method needed. It divided sputum specimens in half and liquid-based cytology. A conventional smear method was conducted and the Papanicolaou's staining was conducted using Autostainer. Diagnosed each slide of staining produced smear slides specimens by using an optical microscope. The result of the liquid-based cytology and conventional smear method was that the liquid-based cytology was of a higher-grade than the conventional smear method. It was 36.8%, and 62.8% in the same condition. But only one case was of a lower grade. Liquid-based cytology showed 86.2% of adequacy, 31.0% of sensitivity and 97.5% of specificity. The conventional smear method showed 54.4% of adequacy, 19.6% of sensitivity and 100% of specificity. If it was conducted with two methods at the same time, the results would be similar to the liquid-based cytology. In conclusion, liquid-based cytology has a more superior adequacy and sensitivity than the conventional smear method. The combination of the two methods is similar to the result of only conducting a liquid-based cytology. Conducting a liquid-based cytology rather than the combination of the two ways of sputum cytoscopy, is to be considered as an efficient method to achieve diagnostic accuracy, reduce labor of clinical technologist and pathologist, and to reduce the expense of patients.

  • PDF

Diagnosis of Malignant Biliary Strictures: Conventional or Negative Pressure Brush Cytology?

  • Abbasi, Mohammad Reza;Mirsaeed, Seyedeh Masoumeh Ghazi;Alizadeh, Amir Houshang Mohammad
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.10
    • /
    • pp.4563-4566
    • /
    • 2016
  • Background/Objective: The aim of this study was to perform a comparative evaluation of the yields of conventional brush cytology and brush cytology with negative pressure in the diagnosis of malignant biliary strictures. Methods: A total of 132 consecutive patients undergoing endoscopic were identified. Of these, 88.0 had brush cytology after ERCP and 44 were Brush cytology with negative pressure. Retrograde cholangiopancreatography (ERCP) including brush cytology and brush cytology with negative pressure in patients with biliary strictures between 2012-2015. Endoscopic retrograde cholangiography was performed with a standard videoduodenoscope Olympus TFJ 160-R (Olympus, Hamburg, Germany) and brush cytology with a Cook medical Double Lumen Biliary BrushTM (Cytology). Means and standard frequencies were used to calculate variables. Results: Positive results for malignancy were obtained in 22 of 88 patients (25%) by brush cytology and 31 of 44 patients (70.4 %) by brush cytology with negative pressure. Conclusions: Sensitivity of cytology sampling could be maximized by negative pressure during ERCP.

Comparison of Unsatisfactory Rates and Detection of Abnormal Cervical Cytology Between Conventional Papanicolaou Smear and Liquid-Based Cytology (Sure Path®)

  • Kituncharoen, Saroot;Tantbirojn, Patou;Niruthisard, Somchai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8491-8494
    • /
    • 2016
  • Purpose: To compare unsatisfactory rates and detection of abnormal cervical cytology between conventional cytology or Papanicolaou smear (CC) and liquid-based cytology (LBC). Materials and Methods: A total of 23,030 cases of cervical cytology performed at King Chulalongkorn Memorial Hospital during 2012-2013 were reviewed. The percentage unsatisfactory and detection rates of abnormal cytology were compared between CC and LBC methods. Results: There was no difference in unsatisfactory rates between CC and LBC methods (0.1% vs. 0.1%, p = 0.84). The detection rate for squamous cell abnormalities was significantly higher with the LBC method (7.7% vs. 11.5%, p < 0.001), but those for overall abnormal glandular epithelium were similar (0.4% vs. 0.6%, p = 0.13). Low grade squamous lesion (ASC-US and LSIL) were more frequently detected by the LBC method (6.1% vs. 9.5%, p < 0.001). However, there was no difference in high gradd squamous lesions (1.1% vs. 1.1%, p = 0.95). When comparing between types of glandular abnormality, there was no significant difference the groups. Conclusions: There was no difference in unsatisfactory rates between the conventional smear and LBC. However, LBC could detect low grade squamous cell abnormalities more than CC, while there were similar rates of detection of high grade squamous cell lesions and glandular cell abnormalities.

Diagnostic Value of Urine Cytology in 236 cases; a Comparison of Liquid-Based Preparation and Conventional Cytospin Method (요 세포 검사의 진단적 가치; 액상세포검사와 고식적 방법의 비교)

  • Lee, Sun;Park, Jung-Hee;Do, Sung-Im;Kim, Youn-Wha;Lee, Ju-Hie;Chang, Sung-Gu;Park, Yong-Koo
    • The Korean Journal of Cytopathology
    • /
    • v.18 no.2
    • /
    • pp.119-125
    • /
    • 2007
  • Urine cytology is an important screening tool for urinary tract neoplasms. Liquid-based preparation methods, such as $ThinPrep^{(R)}$, have been introduced for non-gynecological samples. We aimed to assess the diagnostic accuracy of liquid-based preparations in urine cytology by comparing the results of the conventional Cytospin preparation method for the same samples. A total of 236 cases subject to urine cytology were enrolled in this study from January 2005 to December 2005. All cases were subjected to cystoscopy and if a malignancy was suspected, a biopsy was performed. Urine cytology slides were made using the $ThinPrep^{(R)}$ preparation method and the conventional Cytospin and/or direct smear method from the individual samples. The results of urine cytology were compared with the final cystoscopic or histological diagnoses. We analyzed the sensitivity, specificity, positive predictive value, negative predictive value and accuracy of both cytology preparation methods. A total of 236 slides made using the liquid based method were satisfactory for slide quality, whereas 5 slides (2.1%) prepared by conventional methods were unsatisfactory because of air-drying, a thick smear, or a bloody or inflammatory background. The $ThinPrep^{(R)}$ method showed 53.1% sensitivity, 92.6% specificity, a 92,6% positive predictive value, a 94.1% negative predictive value and 85,6% accuracy, while the conventional method showed 51% sensitivity, 98.4% specificity, a 92.6% positive predictive value, a 98.4% negative predictive value and 88,6% accuracy. Although the diagnostic values were equivalent between the use of the two methods, the quality of the cytology slides and the time consumed during the microscopic examination for a diagnosis were superior for the $ThinPrep^{(R)}$ method than for the conventional method. In conclusion, our limited studies have shown that the use of the liquid based preparation method is beneficial to improve the quality of slides and reduce the duration for a microscopic examination, but did not show better sensitivity, accuracy and predictive values.

Manual Liquid-Based Cytology (Liqui-$PREP^{TM}$) in Breast Fine Needle Aspiration Cytology: Comparison with the Conventional Smears (유방의 세침흡인 세포검사: 수기 액상세포검사법(Liqui-$PREP^{TM}$)과 고식적 도말법과의 비교)

  • Jeong, Ji-Yun;Kim, Jeong-Shik;Kim, Young-Su;Kim, Hye-Jung;Park, Ji-Young
    • The Korean Journal of Cytopathology
    • /
    • v.19 no.1
    • /
    • pp.34-40
    • /
    • 2008
  • Fine needle aspiration (FNA) cytology of the breast is a useful method for diagnosing breast lesions. Yet making the definite diagnosis with performing FNA is limited by some problems, such as the low cellularity, the poor preservation and the obscuring background. Recent studies have found that liquid-based cytology solves such problems, but it is an expensive method and it is limited by the loss of the background information. The purpose of this study is to compare the Liqui-$PREP^{TM}$, a new manual liquid-based method of cytology, and the conventional smears for analyzing breast FNA cytology materials. A total of 31 randomized FNA specimens of breast were studied. In each case, both the conventional smears and the Liqui-$PREP^{TM}$ method were performed, and the smears were evaluated for cellularity, cellular preservation, the background, the cytologic features and the architectural arrangement. The cellularity and architectural arrangement were equal for both preparations. The Liqui-$PREP^{TM}$ specimens showed better cellular preservation, loss of the obscuring background, no overlapping of cells and a smaller area to screen compared with the conventional smears. Moreover, it has the potential advantages of being able to use the remaining specimens for immunohistochemical study and ploidy analysis, and it can reduce the costs for preparation compared with the other liquid-based methods of cytology. But some background information is lost in the Liqui-$PREP^{TM}$ specimens, the same as the other liquid-based methods of cytology. In conclusion, the Liqui-$PREP^{TM}$ and conventional smears showed good correlation, but they have their respective advantages and disadvantages. These results suggest that Liqui-$PREP^{TM}$ can contribute to making the accurate diagnosis with performing breast FNA cytology when it is used along with other methods.

A Comparison of Conventional Cytology and ThinPrep Cytology of Bronchial Washing Fluid in the Diagnosis of Lung Cancer (폐암의 진단 검사 중 기관지 세척액에서 ThinPrep검사법과 기존의 세포검사법의 유용성에 대한 비교)

  • Kim, Sang-Hoon;Kim, Eun Kyung;Shi, Kyeh-Dong;Kim, Jung-Hyun;Kim, Kyung Soo;Yoo, Jeong-Hwan;Kim, Joo-Young;Kim, Gwang-Il;Ahn, Hee-Jung;Lee, Ji-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.6
    • /
    • pp.523-530
    • /
    • 2007
  • Background: A ThinPrep$^{(R)}$ Processor was developed to overcome the limitations of conventional cytology and is widely used to diagnose various cancers. This study compared the diagnostic efficacy of conventional cytology for lung cancer with that of the ThinPrep$^{(R)}$ cytology using the bronchial washing fluid. Methods: The bronchial washing fluid of 790 patients from Jan. 2002 to Dec. 2006, who were suspected of gaving a lung malignancy, was evaluated. Both ThinPrep$^{(R)}$ and conventional cytology were performed for all specimens. Result: Four hundred forty-six men and 344 women were enrolled in this study, and 197 of them were diagnosed with cancer from either a bronchoscopic biopsy or a percutaneous needle aspiration biopsy. ThinPrep$^{(R)}$ cytology showed a sensitivity, specificity, positive predictive value, negative predictive value and false negative error rate of 71.1%, 98.0%, 92.1%, 91.1%, 8.9%, respectively. The conventional cytology showed sensitivity, specificity, positive predictive value, nagative predictive value and false negative error rate of 57.9%, 98.0%, 90.5%, 87.5%, 12.5%, respectively. For central lesions, the sensitivity of conventional cytology and ThinPrep$^{(R)}$ were 70.1% and 82.8%, respectively. Conclusion: ThinPrep$^{(R)}$ cytology showed a higher sensitivity and lower false negative error rate than conventional cytology. This result was unaffected by the histological classification of lung cancer. Therefore, ThinPrep$^{(R)}$ cytology appears to be a useful method for increasing the detection rate of lung cancer in bronchial washing cytology test.

Liquid-Based Cytology Using $MonoPrep2^{TM}$ System in Cervicovaginal Cytology: Comparative Study with Conventional Pap Smear and Histology (고식적 직접 도말법과 $MonoPrep2^{TM}$ system 법에 의한 자궁경부질 세포검사 성적의 비교 검토)

  • Jeon, Yoon-Kyung;Kim, Ok-Ran;Park, Ki-Wha;Kang, Soon-Beom;Park, In-Ae
    • The Korean Journal of Cytopathology
    • /
    • v.15 no.1
    • /
    • pp.33-39
    • /
    • 2004
  • We compared the diagnostic accuracy of liquid-based cervicovaginal cytology using $MonoPrep2^{TM}$ system (Monogen, Herndon, Virginia, USA), a manual system based on membrane filtration method, with conventional Pap smear. Study population included 92 patients visiting the gynecologic department under the suspicion of uterine cervical disease. In thirty of them, surgical biopsy was performed. $MonoPrep2^{TM}$ system provided well-preserved monolayer specimen with good nuclear morphology. However, about 19% of specimens were inadequate to interpret due to low cellularity. The detection rate of abnormal cells more than ASCUS (atypical squamous cells of unknown significance) was 23.9% and higher than 19.4 % of conventional Pap smear. Diagnostic concordance rate with conventional Pap smear was 81%, and severe discordance rate influencing on the management of patient was 7.6 %. Among these seven cases, $MonoPrep2^{TM}$ system was more diagnostic only in four. In comparison with histology, the sensitivity of diagnosis of $MonoPrep2^{TM}$ system was 78.9% and slightly higher than 73.5% of conventional Pap smear. However, the specificity was 81.1% and lower than 90.9% of Pap smear. In conclusion, $MonoPrep2^{TM}$ system provided diagnostic accuracies similar to the conventional Pap smear. The inexpertness of slide preparation and the low cellularity were considered to endow a limitation in more accurate evaluation.

Comparison of Efficacy in Abnormal Cervical Cell Detection between Liquid-based Cytology and Conventional Cytology

  • Tanabodee, Jitraporn;Thepsuwan, Kitisak;Karalak, Anant;Laoaree, Orawan;Krachang, Anong;Manmatt, Kittipong;Anontwatanawong, Nualpan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.16
    • /
    • pp.7381-7384
    • /
    • 2015
  • This study was conducted to 1206 women who had cervical cancer screening at Chonburi Cancer Hospital. The spilt-sample study aimed to compare the efficacy of abnormal cervical cells detection between liquid-based cytology (LBC) and conventional cytology (CC). The collection of cervical cells was performed by broom and directly smeared on a glass slide for CC then the rest of specimen was prepared for LBC. All slides were evaluated and classified by The Bethesda System. The results of the two cytological tests were compared to the gold standard. The LBC smear significantly decreased inflammatory cell and thick smear on slides. These two techniques were not difference in detection rate of abnormal cytology and had high cytological diagnostic agreement of 95.7%. The histologic diagnosis of cervical tissue was used as the gold standard in 103 cases. Sensitivity, specificity, positive predictive value, negative predictive value, false positive, false negative and accuracy of LBC at ASC-US cut off were 81.4, 75.0, 70.0, 84.9, 25.0, 18.6 and 77.7%, respectively. CC had higher false positive and false negative than LBC. LBC had shown higher sensitivity, specificity, PPV, NPV and accuracy than CC but no statistical significance. In conclusion, LBC method can improve specimen quality, more sensitive, specific and accurate at ASC-US cut off and as effective as CC in detecting cervical epithelial cell abnormalities.

Utility of Bile Duct Brush Cytology in Pancreaticobiliary Diseases - Prospective Comparative Study of Conventional Smear and $MonoPrep2^{TM}$ Liquid Based Cytology - (췌담관질환에서 담관 솔질세포검사의 유용성 - 통상도말과 $MonoPrep2^{TM}$ 액상세포검사의 전향적 비교연구 -)

  • Lee, Dong-Wha;Kim, Mee-Sun;Cho, Young-Deok;Cheon, Young-Koog;Choi, Min-Sung;Kim, Dong-Won;Jin, So-Young
    • The Korean Journal of Cytopathology
    • /
    • v.17 no.1
    • /
    • pp.38-45
    • /
    • 2006
  • Bile duct brush cytology has been employed as a diagnostic tool for the evaluation of pancreatic and biliary tract strictures. The specificity of this method is high however, its sensitivity is quite low. A recent study employing liquid based cytology (LBC) reported results comparable to those achieved via conventional cytology. Therefore, we have attempted to prospectively evaluate the diagnostic utility of bile duct brush cytology in pancreaticobiliary diseases. A total of 46 cases with bile duct stricture were enrolled including 11 cases of benign stricture, 29 cases of bile duct carcinoma, 3 cases of gallbladder cancer, and 3 cases of pancreatic cancer. Both conventional smear and LBC using $MonoPrep2^{TM}$ system were conducted in each case. The cytological diagnosis of each case was classed into the following categories; benign, suspicious for malignancy, and malignancy. The diagnostic accuracy of both cytologic methods was investigated. LBC evidenced a high rate of material insufficiency (13/46), which was attributed to low cellularity. The kappa index of both cytological methods was 0.508. Cytological and tissue diagnoses were correlated in 25 cases conducted from biopsy or operation. The sensitivity, specificity, positive predictive value, and negative predictive value were 41.2% (7/17), 100% (8/8), 100% (7/7), and 44.4% (10/18) in conventional smear; 58.8% (10/17), 87.5% (7/8), 90.9% (10/11), and 50.0% (7/14) in LBC; and 94.1% (16/17), 87.5% (7/8), 94.1% (16/17), and 87.5% (7/8) in any one of both cytological methods, respectively. Based on these results, the sensitivity of LBC was found to be superior to that of conventional smear and we were able to obtain higher positive predictive value upto 94.1% by simultaneously conducting both cytologic methods.

Cytologic Findings of Cerebrospinal Fluid (뇌척수액의 세포병리)

  • Jin, So-Young
    • The Korean Journal of Cytopathology
    • /
    • v.19 no.2
    • /
    • pp.86-98
    • /
    • 2008
  • Cerebrospinal fluid (CSF) cytology is based on the cytopathologic findings of other body fluids. However, CSF's cytologic features are less familiar to physicians than are those of the other body fluid's cytology because of the small number of cases. The low overall diagnostic accuracy and the presence of false positivity still remain as problems. The incidence of lymphoreticular malignancies and metastatic carcinomas are rather higher than that of primary brain tumors. In this review, the characteristic cytologic findings of conventional CSF cytology are reviewed along with a brief note on the technical preparation and diagnostic pitfalls.