• 제목/요약/키워드: conventional cone

검색결과 188건 처리시간 0.03초

Usefulness of Mobile Computed Tomography in Patients with Coronavirus Disease 2019 Pneumonia: A Case Series

  • Ji Young Rho;Kwon-Ha Yoon;Sooyeon Jeong;Jae-Hoon Lee;Chul Park;Hye-Won Kim
    • Korean Journal of Radiology
    • /
    • 제21권8호
    • /
    • pp.1018-1023
    • /
    • 2020
  • The coronavirus disease (COVID-19) outbreak has reached global pandemic status as announced by the World Health Organization, which currently recommends reverse transcription polymerase chain reaction (RT-PCR) as the standard diagnostic tool. However, although the RT-PCR test results may be found negative, there are cases that are found positive for COVID-19 pneumonia on computed tomography (CT) scan. CT is also useful in assessing the severity of COVID-19 pneumonia. When clinicians desire a CT scan of a patient with COVID-19 to monitor treatment response, a safe method for patient transport is necessary. To address the engagement of medical resources necessary to transport a patient with COVID-19, our institution has implemented the use of mobile CT. Therefore, we report two cases of COVID-19 pneumonia evaluated by using mobile cone-beam CT. Although mobile cone-beam CT had some limitations regarding its image quality such as scatter noise, motion and streak artifacts, and limited field of view compared with conventional multi-detector CT, both cases had acceptable image quality to establish the diagnosis of COVID-19 pneumonia. We report the usefulness of mobile cone-beam CT in patients with COVID-19 pneumonia.

원뿔형 드럼을 이용한 화학기계적 연마기의 개발 (Development of Chemical Mechanical Polishing machine by Conical Drum)

  • 서헌덕
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1999년도 추계학술대회 논문집 - 한국공작기계학회
    • /
    • pp.525-529
    • /
    • 1999
  • A cone shape drum polisher was developed to make up for the demerits of conventional CMP apparatus. The developed equipment has several superiorities. First of all, it can achieve uniform velocity profile on all the contact line because of its shape and easy to control the amount of slurry at the position of use. The whole area of wafer surface is exposed to the visual area except the contact line between wafer and drum, hence we can detect polishing end point more easily than any other polishing equipments. Also it has additional merits such as small foot print and polishing load. Polishing characteristics were investigated by developed equipment.

  • PDF

Injection Media Affecting Expression of Transgene Introduced by Direct in vivo Injection into Olive Flounder (Paralichthys of olivaceus) Muscle

  • Dong Soo Kim;Chang Hwa Jeong;Young Sun Cho;Yoon Kwon Nam
    • 한국양식학회지
    • /
    • 제12권1호
    • /
    • pp.71-77
    • /
    • 1999
  • The potential utility of injection media (sucrose, PEG, and liposome) was demonstrated for direct gene transfer into olive flounder (Paralichthys olivaceus) muscles. Based on the use of sucrose (final cone. 20%), PEG 8,000 (final cone. 10%) or liposome (twice us of DNA injected), the present injection strategy significantly improved the level of transgene expression as well as persistent duration of expression. The increased amounts of expression in DNA injection with sucrose, PEG, and liposome were as high as from 2.1 to 4.9-folds of conventional TE-based DNA injection. The best result was obtained from injections of liposome-encapsulated DNA in which the expression was detectable at least 32 days after injection when compared to only 8-16 days from TE-based injections.

  • PDF

Enamel renal syndrome with associated amelogenesis imperfecta, nephrolithiasis, and hypocitraturia: A case report

  • Bhesania, Dhvani;Arora, Ankit;Kapoor, Sonali
    • Imaging Science in Dentistry
    • /
    • 제45권3호
    • /
    • pp.181-185
    • /
    • 2015
  • Numerous cases of enamel renal syndrome have been previously reported. Various terms, such as enamel renal syndrome, amelogenesis imperfecta and gingival fibromatosis syndrome, and enamel-renal-gingival syndrome, have been used for patients presenting with the dental phenotype characteristic of this condition, nephrocalcinosis or nephrolithiasis, and gingival findings. This report describes a case of amelogenesis imperfecta of the enamel agenesis variety with nephrolithiasis in a 21-year-old male patient who complained of small teeth. The imaging modalities employed were conventional radiography, cone-beam computed tomography, and renal sonography. Such cases are first encountered by dentists, as other organ or metabolic diseases are generally hidden. Hence, cases of amelogenesis imperfecta should be subjected to advanced diagnostic modalities, incorporating both dental and medical criteria, in order to facilitate comprehensive long-term management.

Condylar jugular diverticulum: A report of 3 cases

  • Jagtap, Rohan;Wazzan, Taggreed;Hansen, Matthew;Kashtwari, Deeba
    • Imaging Science in Dentistry
    • /
    • 제49권3호
    • /
    • pp.251-256
    • /
    • 2019
  • Jugular bulb diverticulum is an irregular extension of the jugular bulb into the temporal bone that may be symptomatic or asymptomatic. The jugular bulb has rarely been reported to extend into the occipital condyle; such extension is termed a condylar jugular diverticulum and is characterized as a defect in the occipital condyle contiguous with the jugular bulb. This report details 3 cases of condylar jugular diverticulum. Extension of the jugular bulb into the ipsilateral occipital condyle was noted as an incidental finding on cone-beam computed tomographic (CBCT) images of 3 patients. All 3 patients were asymptomatic, and this finding was unrelated to the initial area of interest. CBCT use is becoming ubiquitous in dentistry, as it allows 3-dimensional evaluation, unlike conventional radiography. Proper interpretation of the entire CBCT is essential, and recognition of the indicators of condylar jugular diverticulum may prevent misdiagnosis of this rare entity.

Atypical periosteal reaction and unusual bone involvement of ameloblastoma: A case report with 8-year follow-up

  • Charoenlarp, Pornkawee;Silkosessak-Chaiudom, Onanong;Vipismakul, Vichittra
    • Imaging Science in Dentistry
    • /
    • 제51권2호
    • /
    • pp.195-201
    • /
    • 2021
  • Unusual radiographic findings of intraosseous ameloblastoma have been reported and discussed. In the case discussed herein, cone-beam computed tomography (CBCT) clearly showed many radiographic features that were ambiguous on conventional radiographs, including an ill-defined periphery, extensive superficial buccal extension with minimal lingual extension, obvious bucco-crestal expansion, and multiple triangular (Codman's triangle-like) areas of periosteal reaction. Based on the above-mentioned findings, the differential diagnosis was a long-term infected benign or low-grade malignant lesion. An incisional biopsy was performed, and the histopathologic diagnosis was acanthomatous ameloblastoma. Recurrence of the lesion was clearly detected on CBCT images at 4 and 8 years after surgery. These unusual radiographic findings have never been reported to be associated with ameloblastoma, and thus may contribute to novel concepts in radiographic interpretation in the future. This report also underscores the important role played by CBCT as a comprehensive diagnostic tool and for definite confirmation of recurrence.

Dentin Bonding Agent의 근관폐쇄(根管閉鎖) 효과(效果)에 관(關)한 실험적(實驗的) 연구(硏究) (A STUDY OF SEALING ABILITY OF DENTIN BONDING AGENT AS ROOT CANAL SEALER)

  • 민효기;민병순;최호영;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제13권1호
    • /
    • pp.103-111
    • /
    • 1988
  • The purpose of this study was to, examine the sealing ability of the denting bonding agent, when used with gutta percha cone, as a root canal sealer. Seventy two upper and lower extracted human teeth with single root were randomly selected and instrumented in a conventional method with K-file. After instrumentation and dry the canal with paper point, there were divided into three groups and twenty four teeth in each group were filled with the following material; In group I: Scotchbond in combination with gutta percha cone. In group II: AH 26 in combination with gutta percha cone. In group III: Tubli-Seal in combination with gutta percha cone. All specimens were immersed in Indian Ink, decalcified, and cleared. The depth of dye penetration into the canals were evaluated by caliper at the intervals of 1 day, 1 week, 2 weeks. The results were as follows; 1. Depth of dye penetration for all groups increased with time. 2. As to difference in mean dye penetration at time interval of 1 day and 14 days, Scotchbond group exhibited the smallest value as 0.53mm and Tubli-Seal group exhibited the largest value as 0.70mm. 3. There was the difference of dye penetration between each group, but its difference was not significant, statistically.

  • PDF

Clinical Application of Transcatheter Arterial Chemoembolization Combined with Synchronous C-arm Cone-Beam CT Guided Radiofrequency Ablation in treatment of Large Hepatocellular Carcinoma

  • Wang, Zhi-Jun;Wang, Mao-Qiang;Duan, Feng;Song, Peng;Liu, Feng-Yong;Wang, Yan;Yan, Jie-Yu;Li, Kai;Yuan, Kai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권3호
    • /
    • pp.1649-1654
    • /
    • 2013
  • Objective: This work aimed to evaluate the safety and clinical efficacy of transcatheter arterial chemoembolization (TACE) combined with c-arm cone-beam CT guided synchronous radiofrequency ablation (RFA) in treatment of large hepatocellular carcinoma (HCC). Methods: 21 patients with large HCC were studied from January 2010 to March 2012. TACE combined with synchronous C-arm cone-beam CT guided RFA were performed on a total of 25 lesions. Conventional imaging examination (CEUS, enhanced CT or MRI) and AFP detection were regularly conducted to evaluate the technical success rate of combined treatment, complications, treatment response, time without disease recurrence and survival rate. Results: The technical success rate of combined treatment was 100%, without any significant complication. After 1 month, there were 19 cases with complete response and 2 cases with partial response, with an complete response rate of 90.4% (19/21) and a clinical effective rate of 100% (21/21). The complete response rates of single nodular lesions (100%, 17/17) was significantly higher than that of multiple nodular lesions (50%, 2/4) (P<0. 05). During 2 to 28 months of follow-up, in 19 cases with complete response, the average time without disease recurrence was $10.8{\pm}6$ months. The total survival rates of 6, 12 and 18 months in 21 patients were 100%, respectively. Conclusion: TACE combined with synchronous C-arm CT guided RFA is safe and effective for treatment of large HCC. The treatment efficacy for single nodular lesion is better than that for multiple nodular lesions.

Anti-Inflammatory Activity of Pinus koraiensis Cone Bark Extracts Prepared by Micro-Wave Assisted Extraction

  • Kang, Sun-Ae;Kim, Dong-Hee;Hong, Shin-Hyub;Park, Hye-Jin;Kim, Na-Hyun;Ahn, Dong-Hyun;An, Bong-Jeun;Kwon, Joong-Ho;Cho, Young-Je
    • Preventive Nutrition and Food Science
    • /
    • 제21권3호
    • /
    • pp.236-244
    • /
    • 2016
  • In this study, we compared the anti-inflammatory activity of Pinus koraiensis cone bark extracts prepared by conventional extraction and microwave-assisted extraction (MAE). Water extracts and 50% ethanol extracts prepared using MAE were applied to RAW 264.7 cell at 5, 10, 25, and $50{\mu}g/mL$ of concentrations, and tested for cytoxicity. The group treated with $50{\mu}g/mL$ of 50% ethanol extracts showed toxicity. In order to investigate the inhibition of nitric oxide (NO) production in RAW 264.7 cells, extracts of water and ethanol were treated with 5, 10, and $25{\mu}g/mL$ concentrations. The inhibitory activity of water and 50% ethanol extracts groups were determined as 40% and 60% at $25{\mu}g/mL$ concentration, respectively. We found concentration dependent decreases on inducible NO synthase. The inhibitory effect against forming inflammatory cytokines, prostaglandin $E_2$, tumor necrosis factor-${\alpha}$, interleukin (IL)-6, and IL-$1{\beta}$, was also superior in the $25{\mu}g/mL$ treated group than the control group. According to these results, the water extracts and 50% ethanol extracts both inhibited inflammatory mediators by reducing the inflammatory response. Therefore, The MAE extracts of P. koraiensis cone bark can be developed as a functional ingredient with anti-inflammatory activity.

Performance Test of a Real-Time Measurement System for Horizontal Soil Strength in the Field

  • Cho, Yongjin;Lee, DongHoon;Park, Wonyeop;Lee, Kyouseung
    • Journal of Biosystems Engineering
    • /
    • 제41권4호
    • /
    • pp.304-312
    • /
    • 2016
  • Purpose: Soil strength has been measured using a cone penetrometer, which is making it difficult to obtain the spatial data required for precision agriculture. Our objectives were to evaluate real-time horizontal soil strength (RHSS) to measure soil strength in real time while moving across the field. Using the RHSS data, the tillage depth was determined, and the power consumption of a tractor and rotavators were compared. Methods: The horizontal soil-strength index (HSSI) obtained by the RHSS was compared with the cone index (CI), which was measured using a cone penetrometer. Comparison analysis in accordance with the measurement depth that increased at 5-cm interval was conducted using kriged maps at six sensing depths. For tillage control and evaluation of the power consumption, the system was installed with a potentiometer for tillage depth, a torque sensor from the rear axle, and a power take-off (PTO) shaft. Results: The HSSI was lower than the CI, but they were the same at 54.81% of the total grids for the 5-cm depth and at 3.85% for the 10-cm depth. In accordance with the recommended tillage map, tillage operations between 0 and 15 cm left 2.3% and 7% residue cover on the soil, and that between 20 and 10 cm covered a wider utilization of 3% and 18.4%, respectively. When the tillage depth was 15 cm, the comparison result of the power requirements between the PTO and rear axle in terms of control performance revealed that the maximum power requirements of the axle and PTO were 44.63 and 23.24 kW, respectively. Conclusions: An HSSI measurement system was evaluated by comparison with the conventional soil strength measurement system (CI) and applied to a tractor to compare the tillage power consumption. Further study is needed on its application to various farm works using a tractor for precision agriculture.