• Title/Summary/Keyword: contrast flow

Search Result 503, Processing Time 0.028 seconds

Effect of Oil Supply Direction on Power Loss and Bearing Temperature of Elliptical Bearing (오일공급 방향에 따른 타원형 베어링 손실 및 온도 특성)

  • Bang, Kyungbo;Choi, Yonghoon;Cho, Yongju
    • Tribology and Lubricants
    • /
    • v.34 no.4
    • /
    • pp.138-145
    • /
    • 2018
  • Elliptical bearings are widely used for large steam turbines owing to their excellent load carrying capacity and good dynamic stability. Power loss in bearings is an extremely important parameter, especially for high turbine capacities. Optimization of operation conditions and design variables such as bearing clearance and bearing length can reduce the power loss in elliptical bearings. Although changes in the oil supply method have served to increase the efficiency of the tilting pad journal bearing, it has not explicitly improved elliptical bearings. In this study, we verify the static characteristics of an elliptical bearing by changing the direction of oil supply. We evaluate the bearing power loss and bearing metal temperature, and compare the bearing performance and reliability in different test cases. The direction of oil supply is $90^{\circ}$ (9 o'clock) and $270^{\circ}$ (3 o'clock) when the rotor rotates in a counterclockwise direction. We use an elliptical bearing with an inner diameter and active length of 220.30 and 110.00 mm, respectively. Bearing power loss and bearing metal temperatures are measured and evaluated by rotor rotational speed, oil flow rate, and bearing load. The results reveal a 20 reduction in the power loss when the direction of oil supply is 90. Furthermore, the oil film on the upper part of the bearing has a high temperature when the direction of oil supply is $90^{\circ}$. In contrast, when the direction of oil supply is $270^{\circ}$, the oil film on the upper part of the bearing is relatively cold.

An Optimal Operation of Multi-Reservoirs for Flood Control by Incremental DP (Incremental DP에 의한 홍수시 댐군의 연계운영)

  • Lee, Jae-Hyeong;Lee, Gil-Seong;Jeong, Dong-Guk
    • Water for future
    • /
    • v.25 no.2
    • /
    • pp.47-60
    • /
    • 1992
  • An optimal operation model for flood control of multi-reservoirs, Hwacheon and Soyanggang, located in the north Han River basin is developed by using the Incremental DP. The objective function is to minimize the peak flow at the confluence point, of Euam dam, and the hydraulic and hydrologic constraints are established by considering the related laws as to the operation of dam in flood season, each reservoir and channel characteristics. In particular, the final elevations of each reservoir are induced to the conservation pool level in order to prepare for the secondary flood. In addition, the results of this model, simulation results and the single reservoir operation by DP are compared in terms of control and utility efficiencies, and also the peak flows at the confluence point for floods with various return periods are compared with the results of simulation suing feedback control. as the results, the control and utility effciencies are more or less low in contrast with the results of simulation and the single reservoir operation by DP, and the peak flows at confluence point are high because of terminal condition of reservoir storage.

  • PDF

Comparative study on properties of commercial polyvinyl siloxane impression materials (시판 폴리비닐실록산 인상재의 물성에 관한 비교연구)

  • Kang, Jae-Kyoung
    • Journal of Korean society of Dental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.171-180
    • /
    • 2001
  • The purpose of this study was to compared with the properties of commercial polyvinyl siloxane impression materials on the Korean product and the other country one. The materials used in this study were 5 hydrophilic polvinyly siloxane impression materials of light body automixing type (Perfect-F, Handae Chemical, Korea; Examix, GC, Japan; Contrast, VOCO, Germany; Express, 3M, U.S.A; Extrude, Kerr, U.S.A.). Specimens of each impression material were fabricated from a mold with dimensions identical to that specified in ASTM D624-91 and were subjected to tensile lode at 500 mm/min until failure for tear strength. Properties of consistency, strain in compression, recovery from deformation, detail reproduction and linear dimensional change were tested according to the testing methods of the ISO specification no.4823(1992). From this study, the follow ing results were obtained 1. The tear strength values were high ET(3.4kN/m), EP(3.4kN/m), PF(3.0kN/m), CT(3.0kN/m), but the lowest was EM(2.2kN/m)(p<0.05). 2. In the consistency, CT(47 mm) had the highest value, followed by PF(42.1 mm), ET(41.2 mm), and EM(39.6 mm), EP(39.2 mm)(p<0.05). It means more flow that the consistency value is high. 3. The strain in compression values were high followed by EM(5.8%), PF(52%), CT(4.6%), ET(4.1%), EP(2.9%)(p<0.05). 4. In the recovery from deformation, ET(99.95%) and PF(99.90%) had the highest value, followed by EP(99.75%), EM(99.74%) without statistical signification, CT(99.64%) had the lowest value(p<0.05). 5. Detail reproduction reappeared to line $20{\mu}m$ all products. 6. The linear dimensional change was a little shrinked all products. and there were not statistical signification (p>0.05). All products were satisfied the ISO specification.

  • PDF

3차원 치료계획용 전산화단층촬영에서 영상증강을 위한 최적의 프로토콜에 관한 연구

  • 이상규;이석;김주호;백종걸;조정희;신동봉;박재일
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2002
  • 1. 목적 : 방사선종양학과에서 3차원 치료계획용 전산화단층촬영 시 조영제 주입율에 따른 CT 값(hounsfield unit, H.U) 변화를 정량적으로 평가하여 최적의 영상증강효과 및 방사선치료계획을 위한 기초 프로토콜을 제시하고자 한다. 2. 대상 및 방법: 연세암센터 방사선종양학과에서 3차원 치료계획용 전산화단층촬영을 시행한 상복부(폐암)환자 20명을 대상으로 하였다. 조영제 양(130mL)은 일정하게 고정하였고, 조영제주입율을 1.2, 1.5, 2.0 mL/sec로 변화시켜가며 조영제를 주입하면서 3차원 방사선치료계획영상에 적합한 조영제주입율(contrast flow rate)과 지연시간(delay time)을 도출하였고, CT 값을 측정하여 정량적 평가를 시행하였다. 관심부위는 폐동맥과 폐정맥으로 하였다. 그리고, 환자 기본정보, 조영제주입율, H.U 등 영상증강에 영향을 미치는 인자들을 통계처리 프로그램인 SPSS를 이용하여 최적의 영상을 획득할 수 있는 기초 프로토콜을 작성하였다. 3. 결과 : 폐암환자의 전산화단층촬영영상 획득 시 3차원 방사선치료계획에 적합한 영상을 얻을 수 있는 조건중 조영제주입율은 1.5 mL/sec 이었고, 지연시간은 $60{\sim}70$초이었다. 통계처리를 수행한 결과 환자의 기본정보 및 조영제주입율 등이 영상증강에 영향을 미치는 인자임을 알 수 있었다. 본 연구에서 작성한 기초 프로토콜을 이용하여 3차원 방사선치료계획 시 정확한 종양 및 정상조직 설정이 용이하게 되어 방사선치료 효율을 극대화 할 수 있었다. 4. 결론 : 방사선종양학과에서 3차원 치료계획용 전산화단층촬영 시 사용할 수 있는 기초적인 영상획득 프로토콜을 도출하였고, 향후 더 많은 임상경험과 정량적 평가가 수반된다면 임상에 적극 사용할 수 있을 것이라 사료된다.

  • PDF

Usefulness of Functional MRI for the study of concentration sheet (Functional MRI를 이용한 학습집중력 향상 시트 개발)

  • Kim, Chang-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2985-2989
    • /
    • 2009
  • An experiment was conducted to examine the effects of ceramic sheet on concentration of students studies. To demonstrate the improvement in the concentration of study, we obtained functional magnetic resonance imaging (fMRI), which has superior time resolution and measures brain noninvasively by using intrinsic contrast agent. As a result of Brainwave measurement, we could verify the blood flow's activate in the nearby frontal lobe related to memory process and noticeable ratio change in absolute alpha wave and beta wave after the analysis of Brainwave measurement. fMRI ascertains the physiological function of the brain and is being used to prevent the trouble medically that can be caused before and after the operation. For the visibility of cranial nerve network, many researches will be carried out to develope the product which is related to brain like concentration of study.

Efficient Killing Effect of Osteosarcoma Cells by Cinobufacini and Cisplatin in Combination

  • Huang, Tao;Gong, Wei-Hua;Li, Xiu-Cheng;Zou, Chun-Ping;Jiang, Guang-Jian;Li, Xu-Hui;Qian, Hao
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.6
    • /
    • pp.2847-2851
    • /
    • 2012
  • Purpose: To study the killing effects on osteosarcoma cells of cinobufacini and cisplatin in combination and the related mechanisms so as to explore the chemotherapeutic method with integrated traditional Chinese and Western medicines. Methods: Cinobufacini and cisplatin were applied to OS732 cells singly or jointly and survival rates were measured by MTT assay. Changes in cellular shape were observed with inverted phase contrast and fluorescence microscopy and apoptosis rates were analyzed with flow cytometry (FCM). Immunocytochemistry were used to examine the Fas expression of OS732 cells. Results: The combination of cinobufacini and cisplatin had the effect of up-regulating Fas expression and inducing apoptosis. The survival rate of combined application of 100 ${\mu}g/ml$ cinobufacini and 1 ${\mu}g/ml$ cisplatin on OS-732 cells was significantly lower than with either of the agents alone (p<0.01). Changes in cellular shape and apoptotic rates also indicated the apoptosis-inducing effects of combined application were much enhanced. Conclusion: The combination of cinobufacini and cisplatin demonstrated strong killing effects on OS-732 cells which might be related to up-regulation of Fas expression.

Intracellular pH is a Critical Element in Apoptosis Triggered by GM-CSF Deprivation in TF1 Cells

  • Yoon, Suk Ran;Choi, In Pyo
    • IMMUNE NETWORK
    • /
    • v.3 no.4
    • /
    • pp.268-275
    • /
    • 2003
  • Background: Hemopoietic cells require the constant presence of growth factors for survival in vitro and in vivo. Caspases have been known as central executors of apoptotic cell death. We have, therefore, investigated the pathways that regulate caspase activity and apoptosis using the $CD34^+$ cell line, TF-1 which requires GM-CSF for survival. Methods: Apoptosis was measured by annexin V staining and mitochondrial membrane potential was measured by DiOC6 labelling. Intracellular pH was measured using pH sensitive fluorochrome, BCECF or SNARF-1, followed by flow cytometry analysis. Caspase activation was analyzed by PARP cleavage using anti-PARP antibody. Results: Removal of GM-CSF induceed PARP cleavage, a hallmark of caspase activity, concomitant with pHi acidification and a drop in mitochondrial potential. Treatment with ZVAD, a competitive inhibitor of caspases, partially rescued cell death without affecting pHi acidification and the reduction of mitochondrial potential, suggesting that both these events act upstream of caspases. Overexpression of Bcl-2 prevented cell death induced by GM-CSF deprivation as well as pHi acidification and the reduction in mitochondrial membrane potential. In parental cells maintained with GM-CSF, EIPA, a competitive inhibitor of $Na^+/H^+$ antiporter induced apoptosis, accompanied by a drastic reduction in mitochondrial potential. In contrast, EIPA induced apoptosis in Bcl-2 transfectants without causing mitochondrial membrane depolarization. Conclusion: Taken together, our results suggest that the regulation of $H^+$fluxes, either through a mitochondriondependent or independent pathway, is central to caspase activation and apoptosis.

Local Current Distribution in a Ferromagnetic Tunnel Junction Fabricated Using Microwave Excited Plasma Method (마이크로파 여기 프라즈마법으로 제조한 강자성 터널링 접합의 국소전도특성)

  • Yoon, Tae-Sick;Kim, Cheol-Gi;Kim, Chong-Oh;Masakiyo Tsunoda;Migaku Takahashi;Ying Li
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.2
    • /
    • pp.47-52
    • /
    • 2003
  • Ferromagnetic tunnel junctions were fabricated by dc magnetron sputtering and plasma oxidation process. The local transport properties of the ferromagnetic tunnel junctions were studied using contact-mode Atomic Force Microscopy (AFM) and the local current-voltage analysis. Tunnel junctions with the structure of sub./Ta/Cu/Ta/NiFe/Cu/Mn$\_$75/Ir$\_$25//Co$\_$70/Fe$\_$30//Al-oxide were prepared on thermally oxidized Si wafers. Al-oxide layers were formed with microwave excited plasma using radial line slot antenna (RLSA) for 5 and 7 sec. Kr gas was used as the inert gas mixed with $O_2$ gas for the plasma oxidization. No correlation between topography and current image was observed while they were measured simultaneously. The local current distribution was well identified with the distribution of local barrier height. Assuming the gaussian distribution of the local barrier height, the ferromagnetic tunnel junction with longer oxidation time was well fitted with the experimental results. As contrast, in the case of the shorter time oxidation junction, the current mainly flow through the low barrier height area for its insufficient oxygen. Such leakage current might result in the decrease of tunnel magnetoresistance (TMR) ratio.

Characteristics of Ground Movement in High Filling Abutment on Soft Ground (연약지반상 고성토 교대구간의 지반거동 특성)

  • Heo, Yol;Song, Seokcheol;Ahn, Kwangkuk;Oh, Seungtak;Seo, Sanggu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.7
    • /
    • pp.13-23
    • /
    • 2008
  • In this study, the centrifuge tests and numerical analyses were performed to investigate the lateral flow behavior and stability of abutment when high filling was applied on the soft ground improved by SCP. The centrifuge model tests and numerical analyses were fulfilled in the case of the back of abutment filled by EPS (case 1) and soil (case 2), and the potentiometer was installed on the abutment and fill to measure the vertical and horizontal displacement at the top of abutment. As a result of the centrifugal tests, the horizontal displacement of abutment in the case 1 was 1.4cm that is almost coincide with the results of numerical and satisfy the allowable standard. On the other hand, the horizontal displacement of abutment in the case 2 was 12 cm that is 18% greater than that of numerical analysis and exceed the allowable standard. As a result of analysis, the maximum horizontal displacement of pile was 1.26 cm in case 1 that satisfies the criterion of allowable horizontal displacement (1.5 cm). In contrast, the maximum horizontal displacement of pile was 1.005 m in case 2 that greatly exceeds the allowable horizontal displacement.

  • PDF

Impact of Debt ratio on Earnings Management after Global Financial Crisis - Comparative Study of Korea and Japan - (글로벌 금융위기 이후 기업의 부채비율이 이익조정에 미치는 영향 - 한·일 비교연구 -)

  • Noh, Gil-Kwan
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.12
    • /
    • pp.299-305
    • /
    • 2019
  • This study analyzed the relationship between the debt ratios of Korean and Japanese manufacturing firms with accruals and actual earnings managements after the global financial crisis. This study was conducted on Korean and Japanese firms from 2008 to 2015. As a result, the Korean firms, the higher (lower) debt ratio is, more up(down)side earnings management using discretionary accruals and operating cash flow. In contrast, the Japanese firms found that the higher(lower) the debt ratio is, more up(down)side through its actual activities (operating cash flows, manufacturing costs, discretionary costs) rather than accruals. This study establishes the academic basis for the decision-making of Korean-Japanese firmss by using the sample of each country to check what kind of decision-makers are making earnings managements at the present time when the relationship between Korea and Japan has suffered due to export restrictions. It is meaningful in that it was.