• Title/Summary/Keyword: contour of breast

Search Result 44, Processing Time 0.019 seconds

Delayed versus Delayed-Immediate Autologous Breast Reconstruction: A Blinded Evaluation of Aesthetic Outcomes

  • Albino, Frank P.;Patel, Ketan M.;Smith, Jesse R.;Nahabedian, Maurice Y.
    • Archives of Plastic Surgery
    • /
    • v.41 no.3
    • /
    • pp.264-270
    • /
    • 2014
  • Background The technique of delayed-immediate breast reconstruction includes immediate insertion of a tissue expander, post-mastectomy radiation, followed by reconstruction. The aesthetic benefits of delayed-immediate reconstruction compared to delayed reconstruction are postulated but remain unproven. The purpose of this study was to compare aesthetic outcomes in patients following delayed and delayed-immediate autologous breast reconstruction. Methods A retrospective analysis was performed of all patients who underwent delayed or delayed-immediate autologous breast reconstruction by the senior author from 2005 to 2011. Postoperative photographs were used to evaluate aesthetic outcomes: skin quality, scar formation, superior pole contour, inferior pole contour, and overall aesthetic outcome. Ten non-biased reviewers assessed outcomes using a 5-point Likert scale. Fisher's Exact and Wilcoxon-Mann-Whitney tests were used for comparative analysis. Results Patient age and body mass index were similar between delayed (n=20) and delayed-immediate (n=20) cohorts (P>0.05). Skin and scar quality was rated significantly higher in the delayed-immediate cohort (3.74 vs. 3.05, P<0.001 and 3.41 vs. 2.79, P<0.001; respectively). Assessment of contour-related parameters, superior pole and inferior pole, found significantly improved outcomes in the delayed-immediate cohort (3.67 vs. 2.96, P<0.001 and 3.84 vs. 3.06, P<0.001; respectively). Delayed-immediate breast reconstruction had a significantly higher overall score compared to delayed breast reconstructions (3.84 vs. 2.94, P<0.001). Smoking and the time interval from radiation to reconstruction were found to affect aesthetic outcomes (P<0.05). Conclusions Preservation of native mastectomy skin may allow for improved skin/scar quality, breast contour, and overall aesthetic outcomes following a delayed-immediate reconstructive algorithm as compared to delayed breast reconstruction.

Reverse Abdominoplasty with Augmentation Mammoplasty Using Breast Implant: A Case Report (보형물을 이용한 유방성형술을 동반한 역복부성형술의 치험례)

  • Bae, In-Ho;Lee, Yoon-Ho
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.535-538
    • /
    • 2011
  • Purpose: The reverse abdominoplasty has been reported infrequently as a procedure to improve the upper abdominal wall contour. Especially, there have been rare cases on the surgical techniques with augmentation mammoplasty using implant. It is known to maintain the result. Methods: This is a retrospective review of the senior surgeon's patients who underwent reverse abdominoplasty with augmentation mammoplasty. A 63-year-old female was dissatisfied with her contracted breast and upper abdominal contour after previous abdominal wall liposuction. We performed reverse abdominoplasty with augmentation mammoplasty through same inframammary incision. Results: There was a significant improvement of the upper abdominal wall and breast contour. There was no perioperative complication. The patients was satisfied with the results and retained a good shape during the 3 months follow-up periods. Conclusion: Reverse abdominoplasty with augmentation mammoplasty is an acceptable technique that provides good results and should be considered in cases of upper abdominal laxity with capsular contracture on both breasts.

Chest Wall Contouring of Poland's Syndrome (폴란드 증후군 환자의 가슴윤곽 재건)

  • Ahn, Yong-Su;Ahn, Hee-Chang;Kim, Youn-Hwan
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.409-414
    • /
    • 2010
  • Purpose: Poland's syndrome encompasses a constellation of congenital chest wall, breast, and upper extremity deformities. We would like to present several techniques, which may be combined if necessary, used to treat the forms involving both the breast and chest wall according to the degree of deformity. Methods: In a retrospective series of 9 patients (3 men and 6 women), we report our experience with reconstructing breast and chest contour deformities associated with Poland syndrome. We recorded their age, gender, the surgical techniques, and the grade in Poland's syndrome according to the classification of Foucras. Results: The breast and chest wall deformities associated with Poland syndrome can be treated in individualized fashion according to the classification of Foucras. In case of 3 male patients with gradeI, II, the latissimus dorsi muscle pedicled flap improved the chest contour deformity. 3 female patients with grade II underwent the latissimus dorsi muscle pedicled flap with breast implant. 2 female patients with gradeIunderwent breast reconstruction with breast implant and fat injection each other. One female patient with severe chest wall deformity (grade III) underwent breast reconstruction using the free TRAM flap. All patients were satisfied with the results without specific complications. Conclusion: The Individualized correction for this syndrome according to the degree of patient's deformity and preference made the overall satisfaction of the patients high.

New Breast Measurement Technique and Bra Sizing System Based on 3D Body Scan Data

  • Oh, Seolyoung;Chun, Jongsuk
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.4
    • /
    • pp.299-311
    • /
    • 2014
  • Objective: The aim of this study was to develop a method for measuring breast size from three-dimensional (3D) body scan image data. Background: Previous bra studies established reference points by directly contacting the subject's naked skin to determine the boundary of the breast. But some subjects were uncomfortable with these types of measurements. This study examined noncontact methods of extracting breast reference points from 3D body scan data that were collected while subjects were wearing standardized soft bras. Method: 3D body scan data of 32 Korean women were analyzed. The subjects were selected from the Size Korea 2010 study. The breast landmarks were identified by graphic analyses of slicing contour lines on 3D body scan data. Results: Three methods determining bra cup size were compared. The M1 and M2 methods determined cup size by calculating the difference between bust girth and under-bust girth. The M3 method determined bra cup size by measuring breast arc length. Conclusion: The researchers proposed an anthropometric bra cup sizing system with the breast arc length (M3 method). It was measured from the geometrically defined landmarks on the 3D body scan slicing contour lines. The new bra cup size was highly correlated with breast depth. Application: The noncontact measuring method used in this study can be applied to the ergonomic studies measuring sensitive body parts.

Various Applications of Deep Inferior Epigastric Artery Perforator Free Flap (심부하복벽천공지 유리피판의 다양한 임상적 적용)

  • Ahn, Hee Chang;Yang, Eun Zin;Kim, Chang Yeon;Lee, Jang Hyun
    • Archives of Plastic Surgery
    • /
    • v.36 no.6
    • /
    • pp.707-713
    • /
    • 2009
  • Purpose: The deep inferior epigastric perforator(DIEP) free flap is well known as an ideal donor site for the breast reconstruction. The flap can provide huge amount of fat tissue for breast and buttock contour, while it is also very useful as a thin skin flap to reconstruct the upper and lower extremities. We used a DIEP free flap in various site reconstructions besides the breast and would like to reinsure the usefulness of this flap. Methods: Twenty nine consecutive patients who underwent DIEP free flap surgery from 2001 January to 2007 December were reviewed. The case constituted seven male patients and twenty two female patients. There were sixteen breast reconstructions, five face reconstructions, five lower extremity reconstructions, two upper extremity reconstructions, and one buttock contour reconstruction. All clinical data were based on the patient's medical records. Results: All DIEP free flaps survived without major complications. There was no hematoma, seroma, or partial necrosis. The donor sites were closed primarily with linear scar on lower abdomen. The thinnest part of flap was 0.7 cm in thickness. The size of the largest flap was $38{\times}13cm$. The flaps were used in various types of skin and adipose tissue, adipose tissue only, and skin only according to the requirement of recipient site. Conclusion: The DIEP free flap was enough to provide a thin and huge flap for both breast and extremity reconstructions. It was able to provide versatile designs with sufficient adipose tissue. So we use it for 3 - dimentional face and buttock contour reconstructions. The DIEP free flap is a valuable reconstructive donor for face, upper and lower extremity in addition to breast without compromising the integrity of abdominal wall.

Usefulness of the Purse-string Suture Technique for Aesthetic Breast Reconstruction Surrounding the Nipple-areolar Complex (유두 유륜 복합체 주변의 미용적 유방 재건을 위한 주머니끈 봉합의 유용성)

  • Song, Jung-Yoon;Jin, Ung-Sik;Chang, Hak;Minn, Kyung-Won
    • Archives of Plastic Surgery
    • /
    • v.38 no.5
    • /
    • pp.715-717
    • /
    • 2011
  • Purpose: In cases of breast reconstruction with a free transverse rectus abdominis musculocutaneous (TRAM) flap after skin-sparing mastectomy with nipple-areolar complex (NAC) removal, the flat contour of the flap's skin paddle can easily look unnatural and dissatisfying. Reconstructed NAC on the flap surface lacks the elevated contour that the normal areola possesses, resulting in an unnatural final result. Therefore, we would like to introduce a novel method to improve this problem and report the satisfactory results we obtained. Methods: Operations were conducted on 19 patients who underwent immediate breast reconstruction with a free TRAM flap and skin-sparing mastectomy from January 2009 to January 2010, with a mean follow-up of nine months. While the TRAM free flap was being inset, a purse-string suture was carried out on the dermal layer of skin flap to create a slight protrusion with Gore-$Tex^{(R)}$ sutures. Results: The elevated mound surrounding the NAC was well maintained for an average follow-up period of nine months. Nipple projection was also well maintained. There was no complaint about breast contour or nipple height reduction. In addition, there was no reported incidence of other complications. Conclusion: The purse-string suture technique presents a more natural breast silhouette around the NAC and helps to maintain nipple projection. Furthermore, it does not require any supplementary incisions or complicated skills. There has been no report of additional complications using this technique.

Implementing Graphic User Interface System for Microwave Radiometry Data to Utilize Breast Cancer Diagnosis (유방암 진단 활용을 위한 마이크로파 라디오미터 측정 데이터의 GUI 시스템 구현)

  • Shin, Seung-Won;Kim, Kyeong-Seop;Lee, Jeong-Whan;Han, Jong-Sam;Heo, Kyou-Hak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.818-824
    • /
    • 2013
  • In this study, a novel Graphic User Interface (GUI) software development system is suggested so that it can be applied to diagnose breast cancer with utilizing 3~4.2 GHz microwave radiometric data. The estimated inner and surface temperature values on the patient's right and left breast in terms of microwave radiometry are visualized in HSV color mapping space and their relevant contour regions and lines are depicted by Marching Square graphic algorithm. Also the database system is implemented in terms of patient and diagnostic module to support the medical decisions concerning the breast cancer diagnosis.

Prevention of Implant Malposition in Inframammary Augmentation Mammaplasty

  • Kim, Yoon Ji;Kim, Yang Woo;Cheon, Young Woo
    • Archives of Plastic Surgery
    • /
    • v.41 no.4
    • /
    • pp.407-413
    • /
    • 2014
  • Background Implant malposition can produce unsatisfactory aesthetic results after breast augmentation. The goal of this article is to identify aspects of the preoperative surgical planning and intraoperative flap fixation that can prevent implant malposition. Methods This study examined 36 patients who underwent primary dual plane breast augmentation through an inframammary incision between September 1, 2012 and January 31, 2013. Before the surgery, preoperative evaluation and design using the Randquist formula were performed. Each patient was evaluated retrospectively for nipple position relative to the breast implant and breast contour, using standardized preoperative and postoperative photographs. The average follow-up period was 10 months. Results Seven of 72 breasts were identified as having implant malposition. These malpositions were divided into two groups. In relation to the new breast mound, six breasts had an inferiorly positioned and one breast had a superiorly positioned nipple-areolar complex. Two of these seven breasts were accompanied with an unsatisfactory breast contour. Conclusions We identified two main causes of implant malposition after inframammary augmentation mammaplasty. One cause was an incorrect preoperatively designed nipple to inframammary fold (N-IMF) distance. The breast skin and parenchyma quality, such as an extremely tight envelope, should be considered. If an extremely tight envelope is found, the preoperatively designed new N-IMF distance should be increased. The other main cause of malposition is failure of the fascial suture from Scarpa's fascia to the perichondrium through an inframammary incision. As well, when this fixation is performed, it should be performed directly downward to the perichondrium, rather than slanted in a cranial or caudal direction.

A Study on Breast Type Classification & Discrimination Using Manual Measurement- Focusing on Korean Women in Their 20s -

  • Sohn, Boo-Hyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.5
    • /
    • pp.137-146
    • /
    • 2020
  • The manual measurements of 182 unmarried women subjects in their 20s was classified 4-breast types. For the breast type classification, 4 factors were identified, such as overall breast factor, upper breast internal shape factor, breast volume factor, and lower breast external shape factor. The breast shapes were 'breast with well-grown upper part', 'flat breast', 'breast with well-grown lower part', and 'protruded breast'. The breast types can be differentiated in 10 items of actual anthropometric dimension the length between frontal neck point and nipple point, length between lateral neck point and nipple point, length between the breast inner points, nipple to nipple breadth, diameter below the breast, inner depth of breast, outer length of breast, length below the breast, length between breast outer point and upper breast point, and contour line length below the breast.

Measurement of Breast Volume and the Area of Breast Base Using 3D Measurement System (3차원 측정시스템을 이용한 유방부피 및 유저면적의 측정)

  • 이현영;이옥경;홍경희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.2
    • /
    • pp.270-276
    • /
    • 2003
  • Methodology was suggested to analyze breast volume, base area of breast bulk. and surface area of breast using the 3D measurement system. Thirty-seven middle-aged (30s-40s) women wearing 80A brassiere were participated in this study. Image of the upper body was captured by Phase-shifting moire. The posture of the subject was adjusted to get the full image of the right breast. Rapidform 2001 was used for the analysis of the images. The mean breast volume was 547.0㎤ and mean base area of breast bulk was 235. I$\textrm{cm}^2$ It was also found that the volume(r=0.169) and surface area of breast(r=10.242) were loosely correlated with the circumference difference between top and under breast. Therefore, it is noted that current selection criterion of cup size based on the difference in the two kinds of breast circumference is inadequate. The result of this study is expected to contribute to the design of ergonomic brassiere as well as surgical operations in the medical field.