• Title/Summary/Keyword: continuous-type

Search Result 2,102, Processing Time 0.039 seconds

Associated-Genes and Virulence Factors of Staphylococcus aureus Isolated from Nasal Cavity of Neonates (신생아 비강에서 분리된 황색포도구균의 병원성 인자와 관련 유전자)

  • Kim, Yung Bu;Moon, Ji Young;Park, Jae Hong
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.1
    • /
    • pp.24-32
    • /
    • 2003
  • Purpose : Nosocomial infection with Staphylococcus aureus, especially methicillin resistant S. aureus, has become a serious concern in the neonatal intensive care unit. The aim of this study is to investigate the virulence factors, and the relationship between the antibiotic resistance and the associated genes of Staphylococcus aureus isolated from nasal cavity of neonates. Methods : Fifty one isolates of S. aureus were obtained from nasal swab taken in 28 neonates in the NICU and nursery of Pusan National University Hospital between February and May, 2001. They were tested in regard to antibiotic susceptibility, coagulase test and typing, plasmid DNA profile, as well as reactivity to enterotoxin A-E(sea, seb, sec, sed, see) genes and toxic shock syndrome toxin-1(tst) gene by polymerase chain reaction(PCR). Associated genes such as mecA, mecR1, mecI, and femA were also determined by PCR. The origin of MRSA strains was assessed using DNA fingerprinting by arbitrarily-primed polymerase chain reaction(AP-PCR). Results : Twenty three(45.1%) and six(11.8%) isolates were resistant to oxacillin and vancomycin respectively. Multidrug resistance to three or more of the antibiotics tested was observed in 51.0% of the isolates. Forty two isolates were coagulase positive and twenty two isolates had mecA gene. Sixteen isolates had both mecA and femA genes and had type I-III plasmids. 64.7% of isolates carried sec gene, and 80.4% carried tst gene. DNA fingerprinting by AP-PCR for 12 MRSA strains showed 10 distinct patterns, suggesting different origins. Conclusion : We confirmed that the prevalence of nasal carriage of S. aureus and the incidence of antimicrobial-resistant S. aureus, especially vancomycin resistance, is very high in neonates who were admitted in NICU and nursery. It is possible that these pathogens are responsible for serious nosocomial infections in neonates. The need for improved surveillance and continuous control of pathogens is emphasized.

Potential of River Bottom and Bank Erosion for River Restoration after Dam Slit in the Mountain Stream

  • Kang, Ji-Hyun;So, Kazama
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.46-46
    • /
    • 2011
  • Severe sediment erosion during floods occur disaster and economic losses, but general sediment erosion is basic mechanism to move sediment from upstream to downstream river. In addition, it is important process to change river form. Check dam, which is constructed in mountain stream, play a vital role such as control of sudden debris flow, but it has negative aspects to river ecosystem. Now a day, check dam of open type is an alternative plan to recover river biological diversity and ecosystem through sediment transport while maintaining the function of disaster control. The purpose of this paper is to verify sediment erosion progress of river bottom and bank as first step for river restoration after dam slit by cross-sectional shear stress and critical shear stress. Study area is upstream reach of slit check dam in mountain stream, named Wasada, in Japan. The check dam was slit with two passages in August, 2010. The transects were surveyed for four upstream cross-sections, 7.4 m, 34 m, 86 m, and 150 m distance from dam in October 2010. Sediment size was surveyed at river bottom and bank. Sediment of cobble size was found at the wetted bottom, and small size particles of sand to medium gravel composed river bank. Discharge was $2.5\;m^3/s$ and bottom slope was 0.027 m/m. Excess shear stress (${\tau}_{ex}$) was calculated for hydraulic erosion by subtracting the values of critical shear stress (${\tau}_{c}$) from the value of shear stress (${\tau}$) at river bottom and bank (${\tau}_{ex}=\tau-{\tau}_c$). Shear stress of river bottom (${\tau}_{bottom}$) was calculated using the cross-sectional shear stress, and bank shear stress (${\tau}_{bank}$) was calculated from the method of Flintham and Carling (1988). $${\tau}_{bank}={\tau}^*SF_{bank}((B+P_{bed})/(2^*P_{bank}))$$ where $SF_{bank}=1.77(P_{bed}/p_{bank}+1.5)^{-1.4}$, B is the water surface width, $P_{bed}$ and $P_{bank}$ are wetted parameter of the bed and bank. Estimated values for ${\tau}_{bottom}$ for a flow of $2.5\;m^3/s$ were lower as 25.0 (7.5 m cross-section), 25.7 (34 m), 21.3 (86 m) and 19.8 (150 m), in N/$m^2$, than critical shear stress (${\tau}_c=62.1\;N/m^2$) with cobble of 64 mm. The values were insufficient to erode cobble sediment. In contrast, even if the values of ${\tau}_{bank}$ were lower than the values for ${\tau}_{bottom}$ as 18.7 (7.5 m), 19.3 (34 m), 16.1 (86 m) and 14.7 (150 m), in N/$m^2$, excess shear stresses were calculated at the three cross-sections of 7.5 m, 34 m, and 86 m distances compare with ${\tau}_c$ is 15.5 N/$m^2$ of 16mm gravel. Bank shear stresses were sufficient for erosion of the medium gravel to sand. Therefore there is potential to erode lateral bank than downward erosion in a flow of $2.5\;m^3/s$. Undercutting of the wetted bank can causes bank scour or collapse, therefore this channel has potential to become wider at the same time. This research is about a potential of sediment erosion, and the result could not verify with real data. Therefore it need next step for verification. In addition an erosion mechanism for river restoration is not simple because discharge distribution is variable by snow-melting or rainy season, and a function for disaster control will recover by big precipitation event. Therefore it needs to consider the relationship between continuous discharge change and sediment erosion.

  • PDF

Effects of Activated Carbon Types and Service Life on Removal of Odorous Compounds: Geosmin and 2-MIB (활성탄 재질과 사용연수에 따른 Geosmin과 MIB 흡착특성)

  • Lee, Hwa-Ja;Son, Hee-Jong;Lee, Chul-Woo;Bae, Sang-Dae;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.4
    • /
    • pp.404-411
    • /
    • 2007
  • Adsorption performance of odorous compounds such as geosmin and 2-MIB on granular activated carbon were evaluated in this study. The coal-based activated carbon was found more effective than other carbons in adsorption of geosmin and 2-MIB. The wood-based virgin activated carbon was less effective than coconut- and coal-based carbon in adsorption nevertheless having larger pore volume and specific surface area than others carbons. The maximum adsorption capacity(X/M) of coal-based activated carbon for geosmin and 2-MIB was $1.2\sim1.9$ and $2.1\sim2.6$ times larger than coconut- and wood-based virgin activated carbon, respectively. Carbon usage rate (CUR) of coal-, coconut- and wood-based virgin activated carbons for geosmin and 2-MIB were 1.72 and 1.44 g/day, 1.72 and 2.05 g/day and 2.12 and 1.90 g/day, respectively. In the evaluation of adsorption isotherm of geosmin and 2-MIB for coal-, coconut- and wood-based virgin activated carbons, k value of 2-MIB was lower than geosmin, It menas 2-MIB is more difficult to remove by activated carbon adsorption than geosmin. The relationship of max. adsorption versus total pore volume of coconut- and wood-based virgin and used activated carbon for geosmin and 2-MIB were $y=264,459\times-79,047(R^2=0.95)$, $y=319,650\times-101,762(R^2=0.93)$.

Injuries and Prevention methods Associated with In-Line Skate (인라인 스케이트시 발생한 손상 밑 예방)

  • Lim Hong Chul;Chun Seung Joo;Rho Young Jin;Hwang Jin Ho;Park Chan Eung;Kim Tae Un
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.2
    • /
    • pp.163-167
    • /
    • 2003
  • Purpose: The purpose of this study is to describe causes and injury mechanisms during inline skating and to find preventive measures .Materials and Methods: We have carefully selected 57 patients who have been treated in our hospital and nearby hospital. There are 37 males and 20 females, and mean age is 9 years 9 months (range,6-40 years old) . We have meticulously investigated their injured sites, their favorite location for inline skating , their use of protective means while they were on the wheels and their injury mechanisms . Results: Injury consisted of 50 fractures,1 meniscal tear,2 medial collateral ligament rupture and 4 contusion or sprain. Fracture sites varied as follows : 33(66$\%$) cases in distal radius and ulna,5(10$\%$) in elbow. 3(6$\%$) in diaphysis of humerus, etc Location at the time of injury varied as follows : 22 cases(39$\%$) in their apartment complex, 19 cases in (33$\%$) narrow streets, and 16 cases(28$\%$) in parks Only five patients admitted that any means of protection were used.2 cases only had knee pad on , 1 case put on elbow pad in addition, and 2 cases put on wrist guard as well. However none of the patients had helmet on Conclusion: We would strongly like to stress the importance of using sufficient protections and of choosing area where it is safe to ride, in order to reduce the risk of accidents. In addition, continuous and effective prior education from inline skate circles may be in order before riding the inline skate.

  • PDF

Evaluation of Temperature and Humidity of a Thermo-Hygrostat of PET/CT Equipment using a Temperature and Humidity Sensor(BME 280) (온·습도센서(BME 280 센서)를 이용한 PET/CT 장비의 항온 항습기 온·습도 평가)

  • Ryu, Chan-Ju;Kim, Jeong-A;Kim, Jun-Su;Yun, Geun-Yeong;Heo, Seung-Hui;Hong, Seong-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • PET(Positron Emission Tomography) devices are used as PET/CT or PET/MRI devices fused with the devices of CT or MRI for obtaining anatomical information. Therefore, the devices are constructed in circular ring-type structure whose length of gantry(the main part of filming) becomes wider and the interior depth becomes longer in comparison to other common medical equipments. scintillator, one of the components in PET devices, is inside the gantry, and as it is consisted of crystal which is sensitive to the change of temperature and humidity, large temperature change can cause the scintillator to be damaged. Though scintillator located inside the gantry maintains temperature and humidity with a thermo-hygrostat, changes in temperature and humidity are expected due to structural reasons. The output value was measured by dividing the inside of the gantry of the PET/CT device into six zones, each of which an Adafruit BME 280 temperature and humidity sensor was placed at. A thermo-hygrostat keeps the temperature and humidity constant in the PET/CT room. As the measured value of temperature and humidity of the sensor was obtained, the measured value of temperature and humidity appeared in the thermohygrostat was taken at the same time. Comparing the average measured values of temperature and humidity measured at each six zones with the average values of the thermo-hygrostat results in a difference of 2.71℃ in temperature and 21.5% in humidity. The measured temperature and humidity of PET Gantry is out of domestic quality control range. According to the results of the study, if there is continuous change in temperature and humidity in the future, the aging of the scintillator mounted in the PET Gantry is expected to be aging, so it is necessary to find a way to properly maintain the temperature and humidity inside the Gantry structure.

A Study on the Evaluation of Patient Dose in Interventional Radiology (중재적방사선검사에서 환자 피폭선량에 관한 연구)

  • Park, Hyung-Sin;Lim, Cheong-Hwan;Kang, Byung-Sam;You, In-Gyu;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.299-308
    • /
    • 2012
  • To perform patient dose surveys in major interventional radiography procedures as a mean of inter-institutional comparison and of establishing reference dose levels with the ultimate goal of optimizing patient doses in the field of interventional radiography. We reviewed international patient dose survey data in the literature and measured patient dose in major interventional radiography procedures (TACE, AVF, PTBD, TFCA, GDC embolization). ESD(Entrance Skin Dose) was measured using TLD chips attached to the patient skin and ED(Effective Dose) was calculated using angiography unit-derived DAP. A survey of patient dose in interventional radiography procedures were also performed with a questionnaire for interventional radiologists and we proposed a guideline for optimizing patient doses in the field of interventional radiology. The patient dose survey data in interventional radiography procedures were very rare in literature compared with those in diagnostic radiography procedures. In TACE, the mean ED was 25.43 mSv and the mean ESD was 511.75 mGy. The mean ED of TACE was not high, but the cumulative dose should be checked, due to longer procedure TACE. In TFCA, the mean ED was 22.6 mSv and it was relatively high compared with data of other countries. In GDC embolization, the mean ED was not available, because GDC embolization was performed with old Image-Intensifier-type unit and there has no unit-installed ionization chamber. Also, the mean ESD of GDC embolization was up to 2,264 mGy and further studies are needed to calculate the net ED of GDC embolization. Patient dose occurred during interventional radiography procedures are high related with the difficulty of the procedure, fluoroscopy time, the number of angiographies and the treatment protocol. Therefore, continuous education and efforts should be made to optimize the patient dose in the field of interventional radiology.

Development of Rapid Analytical Method of Forbidden Medicines in Dietary Supplements Using LC-ESI-Tandem MS (LC-ESI-tandem MS를 이용한 기능성표방식품 중 부정유해물질 신속검사체계 개발)

  • Kim, Hee-Yun;Jang, Young-Mi;Joo, Hyun-Jin;Jung, Young-Hyun;Lee, Myoung-Sook;Park, Jong-Seok;Lee, Kwang-Ho;Lee, Hwa-Mi
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.4
    • /
    • pp.372-379
    • /
    • 2007
  • A high-performance liquid chromatography-electrospray ionization (HPLC-ESI) tandem MS was developed for the rapid and simultaneous determination of forbidden medicines in dietary supplements. Thirteen medicinal components such as PDE-5 inhibitors and their analogues, and the newly identified dimethylsildenafil and xanthoanthrafil, were included in this study. After tentative standardization of molecular ions in both polarities using thirteen references on the mass spectrometer, with ESI-continuous infusion via the syringe pump method, the relative intensity of the ions present in the resulting spectra was quantitatively compared. From the results, the ion mode was selected depending on each reference's characteristics. A HPLC method coupled with the ESI mode was developed considering the matrix effect and interference depending on the type of sample. The validation test of the developed method was followed by carrying out precision, accuracy, recovery, sensitivity and linearity, etc. The method showed sufficiently high sensitivity, reproducibility, and specificity, and produced 4 times faster results when compared with the existing HPLC/UV method for the determination of forbidden compounds in dietary supplements.

The Design and Fabrication of Conversion Layer for Application of Direct-Detection Type Flat Panel Detector (직접 검출형 평판 검출기 적용을 위한 변환층 설계 및 제작)

  • Noh, Si-Cheol;Kang, Sang-Sik;Jung, Bong-Jae;Choi, Il-Hong;Cho, Chang-Hoon;Heo, Ye-Ji;Yoon, Ju-Seon;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.73-77
    • /
    • 2012
  • Recently, Interest to the photoconductor, which is used to flat form X-ray detector such as a-Se, $HgI_2$, PbO, CdTe, $PbI_2$ etc. is increasing. In this study, the film layer by using the photoconductive material with particle sedimentation was fabricated and evaluated. The quantization efficiency of the continuous X-ray with the 70 kVp energy bandwidth was analyzed by using the Monte Carlo simulation. With the results, the thickness of film with 64 % quantization efficiency was 180 ${\mu}m$ which is similar to the efficiency of 500 ${\mu}m$ a-Se film. And $HIg_2$ film has the high quantization efficiency of 74 % on 240 ${\mu}m$ thickness. The electrical characteristics of the 239 ${\mu}m$ $Hgl_2$ films produced by particle sedimentation were shown as very low dark current(under 10 $pA/mm^2$), and high sensitivity(19.8 mC/mR-sec) with 1 $V/{\mu}m$ input voltage. The SNR, which is influence to the contrast of X-ray image, was shown highly as 3,125 in low driving voltage on 0.8 $V/{\mu}m$. With the results of this study, the development of the low-cost, high-performance image detector with film could be possible by replacing the film produced by particle sedimentation instead to a-Se detector.

Assessment of Hydroureteronephrosis in Children Using Diuretic Radionuclide Ureterography (동위원소 이뇨 요관그람을 이용한 소아 요관폐쇄의 평가)

  • Kim, Jong-Ho;Lee, Dong-Soo;Kwark, Cheol-Eun;Lee, Kyung-Han;Choi, Chang-Woon;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Choi, Yong;Choi, Hwang
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.75-84
    • /
    • 1994
  • The need for assessment of ureteric function in the patient with an obviousely dilated ureter has increased particularly with the added spectrum of asymptomatic patients presenting with hydrone-phrosis and hydroureter on antenatal and perinatal ultrasound. To assess the influence of ureteral status on kidney washout during $^{99m}Tc$-DTPA diuretic renography, ureteral images were reviewed in 80 children referred for hydronephrosis. A scintigraphically abnormal ureter was defined as an intense and continuous image of > 10 min during diuretic renography. Out of them, a total of 16 nephroureteral systems in 12 children with scintigraphically abnormal ureter were analyzed. A diuretic washout index using response half time (t1/2) by linear fitting after lasix injection, was determined on renal (Kt1/2) and ureteral (Ut1/2) curves (diuretic renogram vs. diuretic ureterogram). Diuretic ureterogram curve patterns corresponding to normal (type I), obstructive (II) and non-obstructive (III) cases were described. Compared with X-ray data, diuretic renography was highly sensitive (88%) and specific (99%) for detecting any ureteral abnormality. Despite an obstructive Kt1/2 (>20 min), no patient with an abnormal ureter underwent therapy at the ureteropelvic junction because the hydronephrosis regressed after surgery at the lower level. Our data indicate that the abnormal ureter findings during diuretic renography have to be recognized before therapy for children with hydeonephrosis.

  • PDF

Seeding Soils and Tray Types Mediate Growth Characteristics of Perilla Seedlings (상토 및 트레이 종류에 따른 종실용 들깨의 육묘 특성)

  • Park, Jin-Ki;Han, Won-Young;Han, Kil-Su;Ryu, Jong-Soo;Won, Ok-Jae;Jeong, Tae-Uk;Yoon, Young-Ho;Bae, Jin-Woo
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.65 no.1
    • /
    • pp.63-71
    • /
    • 2020
  • The purpose of this study was to analyze the growth characteristics of perilla according to the materials of the seedbed for the development of seedling plug technology suitable for the mechanical transplantation of perilla. Perilla (Perilla frutescens var. japonica Hara) cultivars Deulsaem and Sodam were used in this experiment. The composition ratios of 170 products from 16 companies published in the 'Korean Association of Seedbed Media' homepage were compared according to usage and type, and 11 products that corresponded to the average were selected. The seedbed was classified according to the seedbed for paddy rice as light-weight, semi-weight, and weight, and based on the seedbed for horticulture, as light-weight and ultra-light. The seedlings were placed in 72-cell (semi-automatic), 128-cell (automatic) and 220-cell (automatic) plug trays. We selected 2 light-weight seedbeds of paddy rice and 2 light-weight seedbeds of horticultural products with the highest plant growth. We analyzed plant height and mat formation of the perilla roots. Results showed that the perilla height and mat formation were the best in light-weight seedbeds of paddy rice (product R1). Therefore, light-weight seedbeds of rice (product R1) were suitable for perilla plant transplantation. The estimated major components were vermiculite 41.0%, cocopeat 31.0%, peat moss 5.7%, and red-yellow soil 20.0%. The mechanical transplantation of perilla significantly boosts plant growth and reduces sowing and thinning efforts. However, continuous evaluation of newly introduced, commercial seedbeds is needed.