• Title/Summary/Keyword: continuous-time

Search Result 5,031, Processing Time 0.04 seconds

Analysis of Rainfall Infiltration Velocity in Unsaturated Soils Under Both Continuous and Repeated Rainfall Conditions by an Unsaturated Soil Column Test (불포화토 칼럼시험을 통한 연속강우와 반복강우의 강우침투속도 분석)

  • Park, Kyu-Bo;Chae, Byung-Gon;Park, Hyuck-Jin
    • The Journal of Engineering Geology
    • /
    • v.21 no.2
    • /
    • pp.133-145
    • /
    • 2011
  • Unsaturated soil column tests were performed for weathered gneiss soil and weathered granite soil to assess the relationship between infiltration velocity and rainfall condition for different rainfall durations and for multiple rainfall events separated by dry periods of various lengths (herein, 'rainfall break duration'). The volumetric water content was measured using TDR (Time Domain Reflectometry) sensors at regular time intervals. For the column tests, rainfall intensity was 20 mm/h and we varied the rainfall duration and rainfall break duration. The unit weight of weathered gneiss soil was designed 1.21 $g/cm^3$, which is lower than the in situ unit weight without overflow in the column. The in situ unit weight for weathered granite soil was designed 1.35 $g/cm^3$. The initial infiltration velocity of precipitation for the two weathered soils under total amount of rainfall as much as 200 mm conditions was $2.090{\times}10^{-3}$ to $2.854{\times}10^{-3}$ cm/s and $1.692{\times}10^{-3}$ to $2.012{\times}10^{-3}$ cm/s, respectively. These rates are higher than the repeated-infiltration velocities of precipitation under total amount of rainfall as much as 100 mm conditions ($1.309{\times}10^{-3}$ to $1.871{\times}10^{-3}$ cm/s and $1.175{\times}10^{-3}$ to $1.581{\times}10^{-3}$ cm/s, respectively), because the amount of precipitation under 200 mm conditions is more than that under 100 mm conditions. The repeated-infiltration velocities of weathered gneiss soil and weathered granite soil were $1.309{\times}10^{-3}$ to $2.854{\times}10^{-3}$ cm/s and $1.175{\times}10^{-3}$ to $2.012{\times}10^{-3}$ cm/s, respectively, being higher than the first-infiltration velocities ($1.307{\times}10^{-2}$ to $1.718{\times}10^{-2}$ cm/s and $1.789{\times}10^{-2}$ to $2.070{\times}10^{-2}$ cm/s, respectively). The results reflect the effect of reduced matric suction due to a reduction in the amount of air in the soil.

Application of Radiological Study by Small Bowel Disease - Comparison of Diagnostic Results of Small Bowel Series and Abdominal Pelvic Computed Tomography - (소장 질환별 방사선학적 검사의 적용에 관한 연구 - 소장조영술과 복부골반전산화단층촬영의 결과 분석을 중심으로 -)

  • Lee, Hee-Jung;Son, Soon-Yong;Lee, Won-Hong
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.279-286
    • /
    • 2005
  • Purpose : There are two modalities, those are small bowel series(SBS) and abdominal pelvic computed tomography(CT), for diagnosis of small bowel disease. The aim of this study is to lend radiological technologists who are doing the two modalities assistance in the understanding characteristic of disease by comparing the two results. Meterials and method : 284 patients were examined the two SBS and abdominal pelvic CT together from 1999 to 2003. 250 ml $BaSO_4$ suspension 40 w/v% and 600ml carboxy methyl cellulose 0.5 w/v% were used for SBS. Abdominal Pelvic CT was examined in one hour before taking 450 ml $BaSO_4$ suspension 1.5 w/v%. The CT scan was done in 72 sec after 150 ml contrast media injection. the used protocol was helical mode 5:5 mm pitch 1.375:1, speed 27.50, exposure 120 kv, 240 mA, tube rotation time 0.5 sec. the statistic analysis was conducted with statistical program SPSS 10 version with frequency and crossing analysis. P-value less than 0.05 were considered significant. Results : In the results of SBS, normal findings were 131 patients(46.1%), inflammatory bowel disease(IBD) 64(22.9%), ischemia+ileocolitis+vasculitis 22(7.7%), Obstruction+stricture 21(7.7%) and Others 45(15.9%). In the results of abdominal pelvic CT, normal findings were 103 patients(36.3%), inflammatory bowel disease 65(22.9%), wall thickening+lymphadenopathy 42(14.8%), Fluid collection 17(6%), and Others 57case(20%). The same results of the two were 130patients(45.8%). 30patients(10.6%) of normal finding in SBS were diagnosed as wall thickening+lymphadenopathy and IBD in CT, and 15patients(5.3%) of normal finding in CT were diagnosed as ischemia+ileocolitis+vasculitis, mass and IBD in SBS(p<0.05). Transit time delay was diagnosed in 10patients(3.5%) on only SBS, wall thickening+lymphadenopathy was diagnosed in 20patients(7%) in only CT(p<0.05). Conclusion : We think that proper examination method will be selected in the small bowel disease, if we understand the characteristics of the disease and method.

  • PDF

Study on the Combination of In-situ Chemical Oxidation Method by using Hydrogen Peroxide with the Air-sparging Method for Diesel Contaminated Soil and Groundwater (과산화수소를 이용한 현장원위치 화학적 산화법과 공기분사법(Air-sparging)을 연계한 디젤 오염 토양/지하수 동시 정화 실내 실험 연구)

  • Kim, Nam-Ho;Kim, In-Su;Choi, Ae-Jung;Lee, Min-Hee
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.6
    • /
    • pp.8-17
    • /
    • 2006
  • Laboratory scale experiments were performed to investigate the removal efficiency of the in-situ chemical oxidation method and the air-sparging method for diesel contaminated soil and groundwater. Two kinds of diesel contaminated soils (TPH concentration : 2,401 mg/kg and 9,551 mg/kg) and groundwater sampled at Busan railroad station were used for the experiments. For batch experiments of chemical oxidation by using 50% hydrogen peroxide solution, TPH concentration of soil decreased to 18% and 15% of initial TPH concentration. For continuous column experiments, more than 70% of initial TPH in soil was removed by using soil flushing with 20% hydrogen peroxide solution, suggesting that most of diesel in soil reacted with hydrogen peroxide and degraded into $CO_2$ or $H_2O$ gases. Batch experiment for the air-sparging method with artificially contaminated groundwater (TPH concentration : 810 mg/L) was performed to evaluate the removal efficiency of the air-sparging method and TPH concentration of groundwater decreased to lower than 5 mg/L (waste water discharge tolerance limit) within 72 hours of air-sparging. For box experiment with diesel contaminated real soil and groundwater, the removal efficiency of air-sparging was very low because of the residual diesel phase existed in soil medium, suggesting that the air-sparging method should be applied to remediate groundwater after the free phase of diesel in soil medium was removed. For the last time, the in-situ box experiment for a unit process mixed the chemical oxidation process with the air-sparging process was performed to remove diesel from soil and groundwater at a time. Soil flushing with 20% hydrogen peroxide solution was applied to diesel contaminated soils in box, and subsequently contaminated groundwater was purified by the air-sparging method. With 23 L of 20% hydrogen peroxide solution and 2,160 L of air-sparging, TPH concentration of soil decreased from 9,551 mg/kg to 390 mg/kg and TPH concentration of groundwater reduced to lower than 5 mg/L. Results suggested that the combination process of the in-situ hydrogen peroxide flushing and the air-sparging has a great possibility to simultaneously remediate fuel contaminated soil and groundwater.

The Clinical Comparision of Amrinone and Dopamine after Open Heart Surgery (개심술후 암리논과 도파민의 효과에 대한 임상 비교)

  • 이성호;이현재
    • Journal of Chest Surgery
    • /
    • v.29 no.2
    • /
    • pp.191-198
    • /
    • 1996
  • Amrinone is a non-glycosidic, non-adrenergic positive inotropic agent with peripheral and coronary vasodilator effect. It inhibits phosphodiesterase F-III, the cardiac cyclic-AMP specific phosphodiesterase, selectively and potently. In this study, the effects of IV administered amrinone and dopamine were compared in 40 patients who had open heart surgery. Amrinone was administered as a bolus of 1 5~2mglkg for several minutes, followed by continuous infusion at 5~1 Oug/kg/min. The hemodynamic measurements including heart rate, systolic and diastolic pressure, cardiac index, pulmonary wedge pressure, and systemic vascular resistance were recorded immediately for 12~24 hours awl 7th day following operation. In amrinone group, cardiac index increased from 3.73$\pm$1.39 L/min/m2 to 5.44$\pm$2.65 L/min/m2 at the time of posterative 48 hours (n=20, p< 0.05). The decrease in systemic vascular resistance from 1237.5 $\pm$ 637.7 dyne/sec/cm2 to 1000.8 $\pm$ 608.5 dyne/sec/cm2(p<0.05). In Dopamine group, the heart rate increased from 92.1 $\pm$ 13.0/min to 101.0 $\pm$ 13.1/min and the cardiac index decreased from 3.40 $\pm$ 0.50 L/min/m2 to 2.53 $\pm$ 1.15 L/min/m2 at the time of postoperative 12 hours(p<0.05). Systemic vascular resistance increased from 1058.5 $\pm$ 234.6 dyne/sec/cm2 to 1979.7 $\pm$ 759.2 dynelsec/cm2 The comparison of the hemodynamic effects of amrinone and dopamine, both drugs improved cardiac performance. But the administration of amrinone results in a higher cardiac index, diastolic blood pressure and lower systemic vascular resistance than those achieved with dopamine (p<0.05). The uniqueness of the action of amrinone on the heart and its sustained hemodynamic effect suggest it has clinical promise, pos operative care of cardiac surgery

  • PDF

Effects of Different Day / Night Temperature Regimes on Growth and Clove Development in Cool-type Garlic (Allium sativum L.) (한지형 마늘의 생육 및 인편 발달에 미치는 주야간 온도의 영향)

  • Oh, Soonja;Moon, Kyung Hwan;Koh, Seok Chan
    • Horticultural Science & Technology
    • /
    • v.35 no.1
    • /
    • pp.1-10
    • /
    • 2017
  • We investigated growth, clove development, and photosystem II activity in garlic (Allium sativum L.) grown under different day/night temperature regimes using Soil-Plant-Atmosphere - Research (SPAR) chambers to determine the optimum cultivation temperature and to assess the impact of temperature stress on garlic. In the early stages of growth, plant growth increased markedly with temperature. At harvest time, however, the pseudostem diameter decreased significantly under a relatively low day/night temperature range ($14/10-17/12^{\circ}C$), suggesting that these temperature conditions favor regular bulb growth. At harvest time, the bulb diameter and height were great at $14/10-23/18^{\circ}C$, whereas the bulb fresh weight and number of cloves per bulb were greatest at $17/12-20/15^{\circ}C$. However, the number of regularly developed cloves per bulb was highest at the relatively low temperature range of $14/10-17/12^{\circ}C$, as were the clove length and fresh weight. The photochemical efficiency ($F_v/F_m$) and potential photochemical efficiency ($F_v/F_o$) of photosystem II in the leaves of garlic plants were higher at $14/10-20/15^{\circ}C$ and lower at temperatures below $14/10^{\circ}C$ or above $20/15^{\circ}C$, implying that the $14/10-20/15^{\circ}C$ temperature range is favorable, whereas temperatures outside this range are stressful for garlic growth. Furthermore, at temperatures above $20/15^{\circ}C$, secondary growth of garlic, defined as lateral bud differentiation into secondary plants, continuous growth of the cloves of the primary plants, or the growth of bulbil buds into secondary plants, was enhanced. Therefore, to achieve commercial production of fresh scapes and bulbs of garlic, it may be better to grow garlic at relatively low temperature ranges of $14/10-17/12^{\circ}C$.

Comparison of Two Methods of Recruiting the Acutely Injured Lung (급성 폐손상에서 폐를 Recruit시키는 방법간의 비교 연구)

  • Suh, Gee-Young;Kang, Kyeong-Woo;Park, Sang-Joon;Kim, Ho-Choel;Young, Lim-Si;Chung, Man-Pyo;Han, Jeong-Ho;Kim, Ho-Joong;Kwon, O-Jung;Rhee, Chong-H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.4
    • /
    • pp.500-512
    • /
    • 2000
  • Background : To evaluate the efficacy of two methods of obtaining lung recruitment to reduce ventilator-induced lung injury(VILI). Methods : Fifteen New-Zealand white rabbits were ventilated in the pressure-controlled mode while maintaining constant tidal volume(10 ml/kg) and fixed respiration rate. Lung injury was induced by repeated saline lavage (PaO2<100 mmHg), and the pressure-volume curve was drawn to obtain Pflex. The animals were then randomly assigned to three groups and ventilated for 4 hours. In the control group(n=5), positive end-expiratory pressure(PEEP) less than that of Pflex by 3 mmHg was applied throughout the study. In the recruitment maneuver(RM) group(n=5), RM(CPAP of 22.5 mmHg, for 45 seconds) was performed every 15 minutes in addition to PEEP level less than Pflex by 3 mmHg This phrase is unclear. In the Pflex group, PEEP of Pflex was given without RM. Gas exchange, lung mechanics, and hemodynamics parameters as well as pathology were examined. Results : 1) Both the control and RM groups showed decreasing tendency in PaO2 with time. There was significantly decreased PaO2 at 4 hr compared to Ihr(p<0.05). But in the Pflex group, PaO2 did not decrease with time(p<0.05 vs other groups at 3, 4 hr). PaCO2 did not show significant difference among the three groups. 2) There was no significant difference in static compliance and plateau pressure. Mean blood pressure and heart rate also did not show any significant difference among the three groups. 3) The pathologic exam showed significantly less neutrophil infiltration in the Pflex group than in the control group(p<0.05). There was borderline significant difference in hyaline membrane score among the groups (p= 0.0532). Conclusion : Although recruitment maneuver of the injured lung may be important in decreasing VILI, it alone may not be sufficient to minimize VILI.

  • PDF

A Survey on Risk Factors Related to Job-Low Back Pain in Physical Therapists (물리치료사들의 직업적 요통 발생의 위험요인 조사)

  • Lee, Jun-cheol
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.2
    • /
    • pp.289-297
    • /
    • 2020
  • The purpose of this study was to investigate the prevalence of back pain and the variables related to back pain in physiotherapists. In order to investigate the variables related to the incidence of back pain, The results were as follows : 1. Physical therapists' low back pain occurrence possibility appeared by whole 55.0% by male 11.0% and female 44.0%. 2. A day by people's work environmental special quality with low back pain treat morbidity to 31~40 people 40.0%, office hours per week by 45~49 hours 49.1%, a day stand-up tome be less than 5~7 hours 36.4% and appeared the highest. 3. Case that respond "Do dissatisfaction" to profession which is physical therapists' special psychological quality examined by people's 67.0% which low back pain. 4. Cause of low back pain in special active quality to get low back pain is the highest by case 38.2% that respond is "Special cause does not know, it is because for a long time worked to physical-therapy, and the reason that play waist softness gymnastics examined the highest by case 45.4% that respond is "Because present low back pain serves to be or prevents flare-up." According to result of this research, we could Know physical therapists are professionally endanger of getting low back pain. Specially, we could say physical therapists' low back pain occurrence possibility is high because of their having an experience or regarding work environmental special quality such as a day treatment morbidity, office hours per week, stand-up time for a day. There, educational programs need to improve of work environment and prevent the recurrence of low back pain. In this research, we recognized various variables of physical therapists' low back pain occurrence possibility are related to direct causal connection of low back pain occurrence, but we think continuous research should be tired forward in reply.

Needs analysis for development of training program for newly appointed Home Economics teachers - Focusing on the participants of first-grade teachers qualification training - (초임기 가정과 교사 직무연수 프로그램 개발에 대한 요구 분석 - 1급 정교사 가정 자격연수 대상자 중심으로 -)

  • Lee, Hyunjung
    • Journal of Korean Home Economics Education Association
    • /
    • v.30 no.1
    • /
    • pp.15-28
    • /
    • 2018
  • Teachers are not completed by appointment, but gradually made through self-development and training for a long time. In order to improve a sense of responsibility of home economics teachers, and also to suggest the purpose and direction of program through job training, the needs of training subjects should be preferentially understood. Thus, this study aims to provide basic data for establishing the developmental operation measures of training for home economics teachers, by researching the needs for training performed after the qualification training for first-grade teachers, targeting the teachers participating in the qualification training program for first-grade teachers of home economics in 2017. About the half of the research subjects received the home economics training one time or less for last three years. Through the training for first-grade teachers, the technical improvement of lesson instruction was demanded the most. As professional qualifications that should be cultivated through training, the ability to develop teaching methods and teaching/learning materials was the highest. Regarding the theme of training, the development of teaching/learning materials for home economics was desired the most. They wanted the training method including direct participation with high utilization for lesson, sublation of competition-centered evaluation, preference of instructors with field experience, continuous opportunity of home economics training, and communicative training. Regarding the needs for the 2015 revised curriculum, the demand for the training of 'human development and family' area was the highest. Therefore, in order to improve the professionalism of teachers through home economics training, it would be necessary to improve the educational environment such as temporal room for training and administrative support, and also to provide diverse types of training like group training, remote training, and smartphone app training suitable for changes in the generation of teachers. Also, on top of forming communities of home economics teachers, and sharing great contents of training, there should be individually-customized training for practice and sharing lesson cases.

Real-time Nutrient Monitoring of Hydroponic Solutions Using an Ion-selective Electrode-based Embedded System (ISE 기반의 임베디드 시스템을 이용한 실시간 수경재배 양액 모니터링)

  • Han, Hee-Jo;Kim, Hak-Jin;Jung, Dae-Hyun;Cho, Woo-Jae;Cho, Yeong-Yeol;Lee, Gong-In
    • Journal of Bio-Environment Control
    • /
    • v.29 no.2
    • /
    • pp.141-152
    • /
    • 2020
  • The rapid on-site measurement of hydroponic nutrients allows for the more efficient use of crop fertilizers. This paper reports on the development of an embedded on-site system consisting of multiple ion-selective electrodes (ISEs) for the real-time measurement of the concentrations of macronutrients in hydroponic solutions. The system included a combination of PVC ISEs for the detection of NO3, K, and Ca ions, a cobalt-electrode for the detection of H2PO4, a double-junction reference electrode, a solution container, and a sampling system consisting of pumps and valves. An Arduino Due board was used to collect data and to control the volume of the sample. Prior to the measurement of each sample, a two-point normalization method was employed to adjust the sensitivity followed by an offset to minimize potential drift that might occur during continuous measurement. The predictive capabilities of the NO3 and K ISEs based on PVC membranes were satisfactory, producing results that were in close agreement with the results of standard analyzers (R2 = 0.99). Though the Ca ISE fabricated with Ca ionophore II underestimated the Ca concentration by an average of 55%, the strong linear relationship (R2 > 0.84) makes it possible for the embedded system to be used in hydroponic NO3, K, and Ca sensing. The cobalt-rod-based phosphate electrodes exhibited a relatively high error of 24.7±9.26% in the phosphate concentration range of 45 to 155 mg/L compared to standard methods due to inconsistent signal readings between replicates, illustrating the need for further research on the signal conditioning of cobalt electrodes to improve their predictive ability in hydroponic P sensing.

Implantable Flexible Sensor for Telemetrical Real-Time Blood Pressure Monitoring using Polymer/Metal Multilayer Processing Technique (폴리머/ 금속 다층 공정 기술을 이용한 실시간 혈압 모니터링을 위한 유연한 생체 삽입형 센서)

  • Lim Chang-Hyun;Kim Yong-Jun;Yoon Young-Ro;Yoon Hyoung-Ro;Shin Tae-Min
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.599-604
    • /
    • 2004
  • Implantable flexible sensor using polymer/metal multilayer processing technique for telemetrical real-time blood pressure monitoring is presented. The realized sensor is mechanically flexible, which can be less invasively implanted and attached on the outside of blood vessel to monitor the variation of blood pressure. Therefore, unlike conventional detecting methods which install sensor on the inside of vessel, the suggested monitoring method can monitor the relative blood pressure without injuring blood vessel. The major factor of sudden death of adults is a disease of artery like angina pectoris and myocardial infarction. A disease of circulatory system resulted from vessel occlusion by plaque can be preventable and treatable early through continuous blood pressure monitoring. The procedure of suggested new method for monitoring variation of blood pressure is as follows. First, integrated sensor is attached to the outer wall of blood vessel. Second, it detects mechanical contraction and expansion of blood vessel. And then, reader antenna recognizes it using telemetrical method as the relative variation of blood pressure. There are not any active devices in the sensor system; therefore, the transmission of energy and signal depends on the principle of mutual inductance between internal antenna of LC resonator and external antenna of reader. To confirm the feasibility of the sensing mechanism, in vitro experiment using silicone rubber tubing and blood is practiced. First of all, pressure is applied to the silicone tubing which is filled by blood. Then the shift of resonant frequency with the change of applied pressure is measured. The frequency of 2.4 MHz is varied while the applied pressure is changed from 0 to 213.3 kPa. Therefore, the sensitivity of implantable blood pressure is 11.25 kHz/kPa.