• Title/Summary/Keyword: continuous wave

Search Result 785, Processing Time 0.035 seconds

Study on a cavity ring-down spectrometer with continuous wave laser sources (연속발진 레이저를 이용한 공동 광자감쇠 분광기 연구)

  • 유용심;한재원;김재완;이재용;이해웅
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.4
    • /
    • pp.240-244
    • /
    • 1998
  • Cavity ring-down spectroscopy (CRDS) is a high-sensitive laser spectroscopic technique capable of measuring concentrations of trace gases. We have demonstrated a new design of the CRDS spectrometer with a continuous wave (CW) laser. The ring-dwon signal is produced through blocking the incident CW laser by scanning the cavity length fast toward off-resonance iwth PZT (piezoelectric transducer). We have also measured an absorption spectrum of acetylene overtone transitions near 570 nm at the pressure of 2700 Pa, and the minimum detectable absorption coefficient has been found to be about $3{\times}10^{-9}\cm^{-1}$.

  • PDF

COMPARISON OF WARM GUTTA-PERCHA CONDENSATION TECHNIQUES IN RIBBON SHAPED CANAL : WEIGHT OF FILLED GUTTA-PERCHA (리본형태의 근관에서의 열연화 근관 충전법의 비교 : 근관 충전된 gutta-percha의 무게)

  • Kim, Hyun-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.3
    • /
    • pp.277-283
    • /
    • 2002
  • The purpose of this study is to evaluate the two warm gutta-percha filling techniques by measuring the weight changes of resin blocks before and after canal filling in ribbon shaped canal. Simulated ribbon shaped root canals in 30 transparent resin blocks were instrumented to #40 using .06 taper Profile. 15 resin blocks were obturated with gutta-percha using cold lateral condensation. Warm lateral condensation using the Endotec II was then accomplished on the same 15 blocks. Another 15 resin blocks were obturated using the System B. All canals were obturated without sealer. The resin blocks were weighed after canal preparation and after each subsequent obturation, and then weight changes of the resin blocks were calculated The results were as follows. 1. Warm lateral condensation using Endotec II and continuous wave of condensation using System B produced a denser obturation of gutta-percha compared with conventional cold lateral condensation (p<0.01). 2. There was no significant difference between warm lateral condensation and continuous wave condensation. In conclusion, the warm gutta-percha condensation techniques like warm lateral condensation and continuous wave condensation can be expected to bring favorable canal obturation results in ribbon shaped canals.

Reverberation suppression algorithm for continuous-wave active sonar system based on overlapping nonnegative matrix factorization (중첩 비음수 행렬 분해 기법에 기반한 지속파 능동 소나의 잔향 신호 제거 기법)

  • Lee, Seokjin;Lim, Jun-Seok;Cheong, Myoung Jun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.4
    • /
    • pp.273-278
    • /
    • 2017
  • In this paper, a post-processing algorithm to suppress reverberation for continuous-wave active sonar system is developed. The developed algorithm is designed for a low-doppler environment where the target echo is not distinguishable from the reverberation. The algorithm is developed based on overlapping nonnegative matrix factorization method. The algorithm analyzes the frequency characteristics of transmitting ping signal, then suppresses the reverberation using time-frequency characteristics of the received signal. Simulations performed in order to evaluate the proposed algorithm, and the results show that the proposed algorithm makes 6 dB signal-to-reverberation ratio enhancement in various reverberation energy conditions.

High-power Quasi-continuous Wave Operation of Incoherently Combined Yb-doped Fiber Lasers

  • Jeon, Minjee;Jung, Yeji;Park, Jongseon;Jeong, Hoon;Kim, Ji Won;Seo, Hongseok
    • Current Optics and Photonics
    • /
    • v.1 no.5
    • /
    • pp.525-528
    • /
    • 2017
  • High-energy, high-power, quasi-continuous wave (QCW) operation of double-clad Yb fiber lasers incorporating an incoherent signal combiner is reported. We constructed four efficient, high-power Yb fiber lasers, each of which produced rectangular pulses at 1080 nm with a pulse energy greater than 15 J, and a pulse duration of 10 ms at a repetition rate of 10 Hz, corresponding to an average power of over 150 W and a peak power of over 1.5 kW for ~200 W of incident pump power at 915 nm. These laser outputs were combined by a homemade incoherent fiber signal combiner with low loss, yielding a maximum peak power of ~6.0 kW in a beam with $M^2{\approx}12.5$. The detailed laser characteristics and prospects for further power scaling in QCW operation are discussed.

Study of Damage in Germanium Optical Window Irradiated by a Near-infrared Continuous Wave Laser (근적외선 연속발진 레이저 조사에 의한 게르마늄 광학창 손상 연구)

  • Lee, Kwang Hyun;Shin, Wan-Soon;Kang, Eung-Cheol
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.82-89
    • /
    • 2014
  • The damage in germanium (Ge) optical window irradiated by a near-infrared continuous wave (CW) laser was studied. Laser-induced heating and melting process were surveyed, and the specific laser power and the irradiance time to melt were estimated by numerical simulation. The experiments were also carried out to investigate the macro and micro structure change on Ge window. Results showed that the surface deformation was formed by melting and resolidification process, the damaged surface had a polycrystalline phase, and the transmittance as an optical performance factor in mid-infrared region was decreased. We confirmed that an abnormal polycrystalline phase and surface deformation effect such as hillock formation and roughness increase reduced the transmittance of Ge window and were the damage mechanism of CW laser induced damage on Ge window.

High Power Continuous-Wave and Graphene Q-switched Operation of Er:YAG Ceramic Lasers at ~1.6 ㎛

  • Wang, Yong;Chen, Hao;Shen, Deyuan;Zhang, Jian;Tang, Dingyuan
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.5-9
    • /
    • 2013
  • We report on high-power continuous-wave operations of an Er:YAG ceramic laser in-band pumped by a cladding-pumped Er,Yb fiber laser at 1532 nm. With an output coupler of 10% transmission, the ceramic laser yielded 16.7 W of continuous-wave output at 1645 nm for 28.8 W of incident pump power, corresponding to a slope efficiency of 61.0% with respect to the incident pump power. The lasing wavelength switched to 1617 nm when output couplers of > 20% transmission were used. Up to 16.2 W of 1617 nm output was generated for 33.0 W of incident pump power, corresponding to a slope efficiency of 51.8%. Graphene Q-switched operation of Er:YAG cermic laser at 1645 nm was also demonstrated with stable pulses of 30-74 kHz repetition rates and 1.5-6.4 ${\mu}s$ pulse widths.

Performance of Continuous-wave Coherent Doppler Lidar for Wind Measurement

  • Jiang, Shan;Sun, Dongsong;Han, Yuli;Han, Fei;Zhou, Anran;Zheng, Jun
    • Current Optics and Photonics
    • /
    • v.3 no.5
    • /
    • pp.466-472
    • /
    • 2019
  • A system for continuous-wave coherent Doppler lidar (CW lidar), made up of all-fiber structures and a coaxial transmission telescope, was set up for wind measurement in Hefei (31.84 N, 117.27 E), Anhui province of China. The lidar uses a fiber laser as a light source at a wavelength of $1.55{\mu}m$, and focuses the laser beam on a location 80 m away from the telescope. Using the CW lidar, radial wind measurement was carried out. Subsequently, the spectra of the atmospheric backscattered signal were analyzed. We tested the noise and obtained the lower limit of wind velocity as 0.721 m/s, through the Rayleigh criterion. According to the number of Doppler peaks in the radial wind spectrum, a classification retrieval algorithm (CRA) combining a Gaussian fitting algorithm and a spectral centroid algorithm is designed to estimate wind velocity. Compared to calibrated pulsed coherent wind lidar, the correlation coefficient for the wind velocity is 0.979, with a standard deviation of 0.103 m/s. The results show that CW lidar offers satisfactory performance and the potential for application in wind measurement.

Analytical and Experimental Comparison of the Velocity of a Supersonic Projectile in the Soft Recovery System (저감속 회수장비에서 초음속 시험탄 속도에 대한 이론적 및 실험적 비교 연구)

  • Song, Minsup;Kim, Jaehoon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.619-628
    • /
    • 2021
  • In order to compare numerical analyses made by Song and Kim needed for predicting gas and water filling with experimental results we conducted an experiment to recover a test projectile (43.7 kg with a 155 mm diameter) at a velocity of 775 m/s in a soft recovery system with a length of 179 m using pressurized gas and filled water. The soft recovery system consisting of a series of pressure tubes had a diaphragm, piston, and water plug for filling the pressurized gas and water. We installed a continuous wave Doppler radar system for velocity measurements of the test projectile travelling in the pressure tubes and pressure transducers for measuring the pressure in the soft recovery system. Continuous wave Doppler radar has the advantage of achieving real-time measurements of the velocity of a test projectile. The velocity-time curve of the test projectile, measured using the continuous wave Doppler radar, and the pressure profile were compared with the numerical analysis results. The experiment results show good agreement with the numerical analysis results based on the one-dimensional Euler equation with an HLL Riemann solver.

Systolic blood pressure measurement algorithm with mmWave radar sensor

  • Shi, JingYao;Lee, KangYoon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.4
    • /
    • pp.1209-1223
    • /
    • 2022
  • Blood pressure is one of the key physiological parameters for determining human health, and can prove whether human cardiovascular function is healthy or not. In general, what we call blood pressure refers to arterial blood pressure. Blood pressure fluctuates greatly and, due to the influence of various factors, even varies with each heartbeat. Therefore, achievement of continuous blood pressure measurement is particularly important for more accurate diagnosis. It is difficult to achieve long-term continuous blood pressure monitoring with traditional measurement methods due to the continuous wear of measuring instruments. On the other hand, radar technology is not easily affected by environmental factors and is capable of strong penetration. In this study, by using machine learning, tried to develop a linear blood pressure prediction model using data from a public database. The radar sensor evaluates the measured object, obtains the pulse waveform data, calculates the pulse transmission time, and obtains the blood pressure data through linear model regression analysis. Confirm its availability to facilitate follow-up research, such as integrating other sensors, collecting temperature, heartbeat, respiratory pulse and other data, and seeking medical treatment in time in case of abnormalities.

Numerical study of compression waves passing through two-continuous ducts (두 연속 덕트를 전파하는 압축파의 수치해석적 연구)

  • Kim, Hui-Dong;Heo, Nam-Geon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.6
    • /
    • pp.823-831
    • /
    • 1998
  • In order to investigate the impulsive noise at the exit of high-speed railway tunnel and the pressure transients inside the tunnel, numerical calculations using a Total Variation Dimishing difference scheme were applied to axisymmetric unsteady compressible flow field. Some compression wave forms were assumed to model the compression wave produced in real high-speed railway tunnel. The numerical data were extensively explored to analyze the peak over-pressure and maximum pressure gradient in the pressure wavefront. The effect of the distance and cross-sectional area ratio between two-continuous ducts on the characteristics of the pressure waves were investigated. The peak over-pressure inside the second duct decreases for the distance and cross-sectional area ratio between two tunnels to increase. The peak over-pressure and maximum pressure gradient of the pressure wavefront inside the second duct increase as the maximum pressure gradient of initial compression wave increases. The present results were qualitatively well agreed with the results of the previous shock tube experiment.