• Title/Summary/Keyword: continuous wave

Search Result 785, Processing Time 0.045 seconds

Continuous element method for aeroacoustics' waves in confined ducts

  • Khadimallah, Mohamed A.;Harbaoui, Imene;Casimir, Jean B.;Taieb, Lamjed H.;Hussain, Muzamal;Tounsi, Abdelouahed
    • Advances in nano research
    • /
    • v.13 no.4
    • /
    • pp.341-350
    • /
    • 2022
  • The continuous elements method, also known as the dynamic stiffness method, is effective for solving structural dynamics problems, especially over a large frequency range. Before applying this method to fluid-structure interactions, it is advisable to check its validity for pure acoustics, without considering the different coupling parameters. This paper describes a procedure for taking wave propagation into account in the formulation of a Dynamic Stiffness Matrix. The procedure is presented in the context of the harmonic response of acoustic pressure. This development was validated by comparing the harmonic response calculations performed using the continuous element model with the analytical solution. In addition, this paper illustrates the application of this method to a simple compressible flow problem, since it has been applied solely to structural problems to date.

Design of Decoupled PMC-backed Air Waveguide Antenna for Continuous Wave Ground Penetrating Radar (상호 결합을 최소화한 연속파(CW) Ground Penetrating Radar(GPR)용 공기 도파관 안테나 설계)

  • 제도흥;나정웅
    • Proceedings of the IEEK Conference
    • /
    • 2001.06a
    • /
    • pp.177-180
    • /
    • 2001
  • A decoupled, wide-band, perfectly magnetically conductor(PMC)-backed air waveguide antenna is designed and constructed for the use of the continuous electromagnetic wave ground penetrating radar in the frequency range from 200MHz to 600MHz. Two planar dipoles are located inside air slab covered by PMC on the top side and separated by an air gap from the bottom ground interface. The coupling between the transmitting and the receiving dipoles is calculated by less than -60dB over the frequency from 200MHz to 600MHz.

  • PDF

A Study on Estimation of Lying Posture at Multiple Angles Using Single Frequency Modulated Continuous Wave (FMCW) Radar-Based CNNs (FMCW 레이더 및 CNN을 이용한 다양한 각도로 누운 자세 추정 연구)

  • Jang, Kyongseok;Zhou, Junhao;Kim, Youngok
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2023.11a
    • /
    • pp.349-350
    • /
    • 2023
  • 본 논문에서는 FMCW(Frequency Modulated Continuous Wave) 레이더를 사용하여 재난 상황에서 누워 있는 사람의 다양한 각도의 자세를 통해 사람의 상태를 파악하거나 위치를 추정하고자하였다. 사람의 세 가지 누운 자세 데이터를 전처리하고 이미지로 변환한 데이터를 CNN(Convolutional Neural Network) 1D 모델로 학습시켜 누운 자세를 다양한 각도에서 구별할 수 있는지 분석하여 확인하고자하였으며, 분석 결과 CNN 1D 모델은 99.27%의 정확도를 보였다.

  • PDF

Comparative Study on the Ability of Instruments to Maintain Original Canal Curvature of Continuous rotary System and Single File System (Continuous rotary system과 single file system의 만곡 근관 형태 유지능에 대한 비교 연구)

  • Park, Sang-Hee;Kim, Deok-Joong;Song, Yong-Beom;Lee, Hye-Yun;Kim, Hyoung-Sun;Lee, Kwang-Won;Yu, Mi-Kyung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.4
    • /
    • pp.371-383
    • /
    • 2012
  • Shaping the root canal system to maintain original canal curvature is essential to clinical success in endodontic treatment. Opposed to most root canals that are curved, endodontic instruments are made from straight metal blanks. They have a tendency of straightening the root canal during preparation and frequently result in procedural errors. A new treatment method to maintain original canal curvature during shaping has been introduced for preventing procedural errors. The aim of this study was to compare the ability of instruments to maintain original canal curvature of continuous rotary system and single file system. Thirty ISO 15, 0.02 taper, Endo Training Blocks(Dentsplay Maillefer) were used. Specimens were assigned to 1 of 3 groups for shaping: specimens in group 1 were shaped with ProFile #20/.06 at the WL. Specimens in group 2 were shaped with Mtwo #35/.04 at the WL. Specimens in group 3 were shaped with WaveOne Primary reciprocating files at the WL after the glide path was achieved with PathFile. Pre- and postinstrumentation digital images were superimposed and processed with Matlab r2010b(The MathWorks Inc, Natick, MA) software to analyze the curvature-radius ratio(CRr), representing canal curvature modification. Data for comparison on the ability of instruments to maintain original canal curvature depending on each Ni-Ti file were analyzed with 1-way ANOVA(P<.05). Data for comparison on the ability of instruments to maintain original canal curvature depending on each Ni-Ti file system were analyzed with independent t-test(P<.05). A statistically significant difference(P<0.05) was noted on each Ni-Ti file. ProFile and WaveOne instrumentations maintained the original canal curvature significantly better(P<0.05) than Mtwo file. There were no significant difference(P>0.05) between continuous rotary system and single file system. Under the conditions of this study, ProFile and WaveOne instruments maintained the original curvature significantly better than Mtwo file and were less modification of the canal curvature compared. There was no significant difference between continuous rotary system and single file system in shaping of simulated canals. As clinical practitioners, it may be advantages to use hybrid approach when root canal shapes depending on the design and usage of Ni-Ti files.

A Study on Continuous long-term Wave Observation using Remote Monitoring System (원격모니터링을 이용한 연속파랑관측에 관한 연구)

  • Shin, Bumshick
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.654-659
    • /
    • 2018
  • In this study, continuous long-term observation is implemented with an ocean radar. Ocean radar conducts remote observation (combined) with ground-based radars, which enable a series of simultaneous observations of an extensive range of the coast with high frequency. An ocean radar for continuous long-term observation is operated at Samcheok on the east coast of Korea. Samcheok experienced tsunami damage in recent years and is the location of a nuclear power plant. In order to examine the reliability of the ocean radar, a pressure-type wave gauge, ultrasonic wave gauge, and ocean buoy are installed for the purpose of data comparison and verification. The ocean radar used in this study is an array-type HF-RADAR named WERA (WavE RAdar). The analysis of the data obtained from continuous long-term observations showed that the radar observations were in agreement with more than 90% of the wave data collected within a 25 km range from the center of two sites. Less than 1% of the entire observation data was unmeasured by the time series analysis. As a result of comparing the radar data with the direct observations made by the wave gauge, it was inferred that the RMS deviation is less than 20cm and the correlation coefficient was in the range of 0.84 ~ 0.87. Moreover, supported by such observations, a comprehensive monitoring system is being developed to provide the public with real-time reports on waves and currents via the internet.

COMPARISON OF THE SEALING ABILITY OF VARIOUS ROOT CANAL FILLING TECHNIQUES (근관충전방법에 따른 폐쇄효과의 비교)

  • Lee, Dong-Kyoung;Yoon, Soo-Han;Bae, Kwang-Shik
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.346-356
    • /
    • 1998
  • The purpose of this study was to evaluate the sealing ability of various canal filling methods. Palatal roots of ninety extracted human maxillary molar teeth were resected at cementoenamel junction. Eighty of them were randomly assigned to four experimental groups, ten were served as positive and negative controls. All canals were prepared to # 40 using Profile. Experimental groups were obturated by lateral condensation technique, Thermafil technique, Continuous Wave of Condensation Technique, and down-pack & back-fill technique of Obtura-II, each with root canal sealer. Control groups were not obturated. Teeth were immersed in resorcinol-formaldehyde resin for 5 days at $4^{\circ}C$, and the resin was allowed to polymerize completely for 4 days at room temperature. Teeth were then ground horizontally at 1.5mm(level 1), 2.5mm(level 2), 3.5 mm(level 3) from the anatomical apex and examined with a stereomicroscope at ${\times}40$ magnification. The gap between the canal wall and the filling material, which was filled with the resin, was measured at each of the three levels. Each ratio of leakage was obtained by calculating the ratio of the area of the resin to the total area of the canal and was analyzed statistically (Rank-sum test). The results were as follows : 1. At the level 1, there was the greatest leakage in the Thermafil group and Obtura-II group, and the difference between the Obtura-II group and Continuous Wave of Condensation Technique group was statistically significant(p<0.05). 2. At the level 2, there was the least leakage in the Continuous Wave of Condensation Technique group, but there was no statistically significant difference between each group (p>0.05). 3. At the level 3, there was no statistically significant difference between each group(p>0.05).

  • PDF

A study on the target detection method of the continuous-wave active sonar in reverberation based on beamspace-domain multichannel nonnegative matrix factorization (빔공간 다채널 비음수 행렬 분해에 기초한 잔향에서의 지속파 능동 소나 표적 탐지 기법에 대한 연구)

  • Lee, Seokjin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.6
    • /
    • pp.489-498
    • /
    • 2018
  • In this paper, a target detection method based on beamspace-domain multichannel nonnegative matrix factorization is studied when an echo of continuous-wave ping is received from a low-Doppler target in reverberant environment. If the receiver of the continuous-wave active sonar moves, the frequency range of the reverberation is broadened due to the Doppler effect, so the low-Doppler target echo is interfered by the reverberation in this case. The developed algorithm analyzes the multichannel spectrogram of the received signal into frequency bases, time bases, and beamformer gains using the beamspace-domain multichannel nonnnegative matrix factorization, then the algorithm estimates the frequency, time, and bearing of target echo by choosing a proper basis. To analyze the performance of the developed algorithm, simulations were performed in various signal-to-reverberation conditions. The results show that the proposed algorithm can estimate the frequency, time, and bearing, but the performance was degraded in the low signal-to-reverberation condition. It is expected that modifying the selection algorithm of the target echo basis can enhance the performance according to the simulation results.

The Evaluation of Partially Degraded Material Using Nonlinear Propagation Characteristics of Ultrasonic Wave (초음파 비선형 전파특성을 이용한 부분 열화 재료의 평가)

  • Kim, Kyung-Cho;Jhang, Kyung-Young;Hisashi, Yamawaki
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.2
    • /
    • pp.214-219
    • /
    • 2001
  • In this paper, the nonlinear behavior of ultrasonic wave in partially degraded material is considered. For this aim, FDM(finite difference method) model for the nonlinear wave equation was developed with the restriction to the 1-D longitudinal wave motion and how the partial degradation in material contributes to the detected nonlinear parameter was analyzed quantitatively. In order to verify the rightness of this simulation method, the relation between the detected nonlinear parameter and the continuous distribution of degradation obtained from simulation was compared with experiment results and the simulation and experiment results showed similar tendency. It can be known from simulation result that the degree of degradation, the range of degradation and the continuous distribution of degradation have strong correlation with the detected nonlinear parameter. As it was possible in these simulations that only special part is assumed as degraded one, the quantitative evaluation of partially degraded material may be obtained by using this method.

Heart beat and Respiration Detection Performance of CW radar Based on New Signal Model (새로운 신호모델에 의한 CW 레이다 심장박동 및 호흡검출 성능분석)

  • Lee, Byung-Seub
    • Journal of Satellite, Information and Communications
    • /
    • v.12 no.1
    • /
    • pp.28-33
    • /
    • 2017
  • In this paper, new signal model for bio-signal detection, i.e heart beat and respiration, using CW radar. Most research on this similar topic are based on the conventional signal model which is not correct in envisaging reflected signal from the human body. The system developed based on this conventional model can not predict exact performance of the system. So in this paper modified signal model for bio-radar is proposed and then simulation for detecting heartbeat and respiration signal in AWGN, multipath environment. The detection performance difference between two signal models are discussed.the modified

Polymer Thin Film of Phthalic Anhydride via Plasma Polymerization (플라즈마 중합에 의한 프탈릭 안하이드라이드 고분자 박막 필름 제조 연구)

  • Kang, Hyun Min;Basarir, Fevzian;Paek, Kwan Yeol;Yoon, Tae-Ho
    • Journal of Adhesion and Interface
    • /
    • v.10 no.1
    • /
    • pp.17-22
    • /
    • 2009
  • Polymer thin films were prepared by radio frequency (RF) plasma polymerization of phthalic anhydride (PA). First, monomer vaporization temperature ($100{\sim}160^{\circ}C$) was optimized by evaluating the thermal properties of thin films using differential scanning calorimeter (DSC) and measuring the root-mean-square (RMS) roughness with atomic force microscope (AFM) at the fixed plasma power of 10 W and time of 5 min in a continuous-wave (CW) mode. Plasma power (5~20 W) was then optimized by measuring the film solubility in solvents such as toluene, acetone, dimethylsulfoxide (DMSO) and 1 methylpyrrolidine (NMP). Next, pulsed mode plasma polymerization was also studied by varying the duty cycle of on-time (5, 20%) under optimized conditions of continuous-wave (CW) mode ($120^{\circ}C$, 10 W) in order to increase the anhydride functional groups. Finally, polymer thin films were characterized by Fourier transform infrared spectroscopy (FT-IR), thermogravimetric analyzer (TGA) and ${\alpha}$-step.

  • PDF