• Title/Summary/Keyword: continuous monitoring

Search Result 1,564, Processing Time 0.031 seconds

LANDCOVER CHANGE DETECTION USING MODIS TEMPORAL PROFILE DATA SUPPORED BY ASTER NDVI

  • Yoon, Jong-Suk;Kang, Sung-Jin;Lee, Kyu-Sung
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.382-385
    • /
    • 2008
  • MODIS images have a great advantage of high temporal resolution to monitor land cover changes in a large area. The moderate and low spatial resolution satellite images are incomparably economic than high resolution satellite images. As diverse satellite images are provided recently, strategies using satellite images are necessary for continuous, effective and long-term land monitoring. This research purposed to use MODIS images to monitor land cover in Korean peninsula for long-term and continuous change detection. To maximize the advantages of high temporal resolution, the change detection was based on the MODIS temporal profiles of the surface reflectance for one year. In this study as the reflectance patterns of year 2005 were compared with the reflectance patterns of year 2007, the changed pixels could be detected during two years. To set up the threshold value for the decision of change, ASTER images with the higher spatial resolution, 15m, were used for this study. The test area covered the suburban area of metropolitan city, Seoul, where the landcover changes have been frequently happened.

  • PDF

Vibration Monitoring and Diagnosis System Framework for 3MW Wind Turbine (3MW 풍력발전기 진동상태감시 및 진단시스템 프레임워크)

  • Son, Jong-Duk;Eom, Seung-Man;Kim, Sung-Tae;Lee, Ki-Hak;Lee, Jeong-Hoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.8
    • /
    • pp.553-558
    • /
    • 2015
  • This paper aims at making a dedicated vibration monitoring and diagnosis framework for 3MW WTG(wind turbine generator). Within the scope of the research, vibration data of WTG drive train are used and WTG operating conditions are involved for dividing the vibration data class which included transient and steady state vibration signals. We separate two health detections which are CHD(continuous health detection) and EHD(event health detection). CHD has function of early detection and continuous monitoring. EHD makes the use of finding vibration values of fault components effectively by spectrum matrix subsystem. We proposed framework and showed application for 3MW WTG in a practical point of view.

Characterizing the Spatial-temporal Distribution of Soil Moisture for Sulmachun Watershed Through a Continuous Monitoring (설마천 유역의 토양수분 장기 모니터링을 통한 토양수분 시공간 변화양상의 특성화)

  • Lee, Ga Young;Kim, Ki Hoon;Kim, Sang Hyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.209-214
    • /
    • 2004
  • Time Domain Reflectometry with multiplex system has been installed to configure the spatial and temporal characteristics of soil moisture in a mountainous hillslope. An intensive surveying was performed to build a refined digital elevation model and flow determination algorithms with inverse surveying have been applied to establish an efficient soil monitoring system. Steady state wetness index, quasi-dynamic wetness index and fully dynamic wetness index have been calculated. Continuous monitoring of soil moisture data were analyized with wetness indices. Limitations and hydrological interpretations of this approach have beer discussed.

  • PDF

Computer Based Core Monitoring System for an Operating CANDU Reactor

  • Yoon Moon Young;Kwon Hwan O.;Kim Kyung Hwa;Yeom Choong Sub
    • Nuclear Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.53-63
    • /
    • 2004
  • The research was performed to develop a CANDU-6 Core Monitoring System(CCMS) that enables operators to have efficient core management by monitoring core power distribution, burnup distribution, and the other important core variables and managing the past core history for Wolsong nuclear power plant unit 1. The CCMS uses Reactor Fueling Simulation Program(RFSP, developed by AECL) for continuous core calculation by integrating the algorithm and assumptions validated and uses the information taken from Digital Control Computer(DCC) for the purpose of producing basic input data. The CCMS has two modules; CCMS server program and CCMS client program. The CCMS server program performs automatic and continuous core calculation and manages overall output controlled by DataBase Management System. The CCMS client program enables users to monitor current and past core status in the predefined GUI(Graphic-User Interface) environment. For the purpose of verifying the effectiveness of CCMS, we compared field-test data with the data used for Wolsong unit 1 operation. In the verification the mean percent differences of both cases were the same($0.008\%$), which showed that the CCMS could monitor core behaviors well.

Condition Monitoring in Gear System Using Spike Wavelet Transform (스파이크 웨이블렛 변환을 이용한 기어 시스템의 건전성 감시)

  • 이상권;심장선
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.21-27
    • /
    • 2001
  • Impulsive sound and vibration signals in gear system are often associated with their faults. Thus these impulsive sound and vibration signals can be used as indicators in condition monitoring of gear system. The traditional continuous wavelet transform has been used for detection of impulsive signals. However, it is often difficult for the continuous wavelet transform to identify spikes at high frequency and meshing frequencies at low frequency simultaneously since the continuous wavelet transform is to apply the linear scaling (a-dilation) to the mother wavelet. In this paper, the spike wavelet transform is developed to extract these impulsive sound and vibration signals. Since the spike wavelet transform is to apply the non-linear scaling, it has better time resolution at high frequency and frequency resolution at low frequency than that of the continuous wavelet transform respectively. The spike wavelet transform can be, therefore, used to detect fault position clearly without the loss of information for the damage of a gear system. The spike wavelet transform is successfully is applied to detection of the gear fault with tip breakage.

  • PDF

Monitoring of Long-Term Behavior of The Continuous IPC Girder Bridge (IPC거더 연속교의 장기거동 모니터링)

  • Lee, Hong-Woo;Ahn, Jeong-Seang;Kim, Kyoung-Won;Yu, Sang-Hui
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.349-352
    • /
    • 2008
  • IPC girder is more prestressed and has smaller sectional area than the conventional PSC-I type girder due to incremental prestressing along the construction process. The continuous IPC girder bridge may have problems in serviceability and stresses at internal supports because it is very flexible. In this paper, The long-term behavior of the continuous IPC girder bridge is studied through long-term structural analysis and monitoring the deflections. The long-term behavior is monitored right before the introduction of 2nd prestressing that is the construction process different from the conventional PSC-I type girder bridge. The total station of high-precision was used in measuring the deflections. According to the monitoring result so far, the continuous IPC girder bridges does not show remarkable long-term behavior like severe camber or deflection and the measured deflections are very similar to the results of long-term structural analysis.

  • PDF

Development of Holter ECG Monitor with Improved ECG R-peak Detection Accuracy (R 피크 검출 정확도를 개선한 홀터 심전도 모니터의 개발)

  • Junghyeon Choi;Minho Kang;Junho Park;Keekoo Kwon;Taewuk Bae;Jun-Mo Park
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.23 no.2
    • /
    • pp.62-69
    • /
    • 2022
  • An electrocardiogram (ECG) is one of the most important biosignals, and in particular, continuous ECG monitoring is very important in patients with arrhythmia. There are many different types of arrhythmia (sinus node, sinus tachycardia, atrial premature beat (APB), and ventricular fibrillation) depending on the cause, and continuous ECG monitoring during daily life is very important for early diagnosis of arrhythmias and setting treatment directions. The ECG signal of arrhythmia patients is very unstable, and it is difficult to detect the R-peak point, which is a key feature for automatic arrhythmias detection. In this study, we develped a continuous measuring Holter ECG monitoring device and software for analysis and confirmed the utility of R-peak of the ECG signal with MIT-BIH arrhythmia database. In future studies, it needs the validation of algorithms and clinical data for morphological classification and prediction of arrhythmias due to various etiologies.

Development of PVDF sensor and system to detect breathing sounds during deep sedation (진정 마취 시 호흡음 검출을 위한 PVDF 센서 및 시스템 개발)

  • Lee, Seung-Hwan;Li, Xiong;Im, Jae-Joong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.1
    • /
    • pp.153-159
    • /
    • 2019
  • Respiration is one of the important vital signs to determine the condition of the patient. Especially during deep sedation, since the patient's apnea and hypopnea are difficult to detect without continuous monitoring, there is a need for a continuous respiration monitoring method that can accurately and simply determine the patient's respiratory condition. Currently, respiration monitoring methods using various devices have been developed, but these methods have not only late response time but also low reliability at the clinical stage. In this study, attachable sensor using PVDF(polyvinylidene fluoride) film and a monitoring device which could detect abnormal symptoms of breathing in early stage during deep sedation. The results of this study can be used in various medical fields including not only in the area of remote monitoring for respiration related sleep monitoring but also in routine monitoring during deep sedation.

PD Monitoring of Transformer Using UHF Technique (UHF 기술을 응용한 전력용 변압기의 PD 모니터링)

  • Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2116-2117
    • /
    • 2008
  • This system has successfully captured long intermittent discharge signals that hadn't been detected through conventional techniques, and solved the problem successfully. The results demonstrate that UHF technique has great advantages for on-line PD monitoring of transformers. By adopting the peak detection technique, it becomes easy and effective for the transplantation of the phase-resolved pattern recognition technique from conventional method to UHF method, and then to realize continuous on-line monitoring, source characterization and trending analysis.

  • PDF