• Title/Summary/Keyword: continuous heat treatment

Search Result 157, Processing Time 0.028 seconds

Characteristics on Surface Hardening by using of Continuous Wave Nd:YAG Laser of Cold-Work Die Steel(STD11) about Variation of Focal Lens F-number (초점렌즈 F-수 변화에 의한 냉간금형강 STD11 의 연속파 Nd:YAG 레이저 표면경화 특성)

  • Hwang, Chan-Youn;Yang, Yun-Seok;Lee, Ka-Ram;Yoo, Young-Tae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.4
    • /
    • pp.395-408
    • /
    • 2012
  • An experimental investigation with 2.8kW Nd:YAG laser system was carried out to study the effects of different laser process parameters on the microstructure and hardness of STD11. The optical lens with the elliptical profile are designed to obtain a wide surface hardening area with uniform hardness. The Laser beam is allowed to scan on the surface of the work piece varying the power (1600, 1800 and 1900kW) and traverse speed (200, 400, 600, 800 and 1000mm/min) at three different F-numbers of lens. After laser surface treatment three zones, In the microstructure have been observed : melted zone(decarburization), heat affected zone(martensite), and the substrate.

Effects of Holding Temperatures on Microstructure and Mechanical Properties of CP Titanium and Ti-6Al-4V Alloy and Its low Temperature Brazing Characteristics (열노출 온도에 따른 CP 티타늄, Ti-6Al-4V 합금의 미세조직/기계적성질 변화 및 저온브레이징 특성)

  • Sun, J.H.;Shin, S.Y.;Hong, J.W.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.23 no.1
    • /
    • pp.3-9
    • /
    • 2010
  • Titanium and its alloys were brazed in the range of $850-950^{\circ}C$ within 10 min. of brazing time using expensive infra red or other heating methods. However, brazing time needs to be extended to get temperature-uniformity for mass production by using continuous belt type furnace or high vacuum furnace with low heating rate. This study examined effects of holding temperature for 60 min, on microstructure and mechanical properties of titanium alloys. Mechanical properties of titanium alloys were drastically deteriorated with increasing holding temperature followed by grain growth. Maximum holding temperatures for CP (commercial pure) titanium and Ti-6Al-4V were confirmed as $800^{\circ}C$ and $850^{\circ}C$, respectively. Both titanium alloys were successfully brazed at $800^{\circ}C$ for 60 min. with the level of base metal strengths by using Zr based filler metal, $Zr_{54}Ti_{22}Ni_{16}Cu_8$.

Literary Study on the Climacteric Syndrome (갱년기(更年期) 장애(障碍)에 대(對)한 문헌적(文獻的) 고찰(考察))

  • Kim, Kyung Su;Yoo, Dong Youl
    • Journal of Haehwa Medicine
    • /
    • v.13 no.1
    • /
    • pp.107-128
    • /
    • 2004
  • This thesis is focused to get treatment on climacteric syndrome through literary study. The results are followed as below. 1. The climacteric syndrome is beginning with lowering of secretion of female hormone. It's not understood as abnormal disease but as normal phenomenon. 2. The causes of climacteric syndrome are defined as deficiency of the Kidney, stagnation of Liver, disharmony between Heart and Kidney, insufficiency of both the Heart and the Spleen, blood stagnation. 3. The causes of climacteric bleeding are continuous with overstrain, injury of the five emotions, blood heat, deteriorating blood. 4. The treatment of climacteric syndrome are mainly nutrition of Kidney and Liver, that of Kidney heat, descending Yang of Liver, nutrition of blood of heart, having a comunication with Kidney and Heart, nutrition of Spleen and Stomarch. 5. For the prescriptions on climacteric syndrome, the treatments such as Jaguium(左歸飮), Wooguium(右歸飮), Soyosan(逍遙散加減), Jibakjihwangtang(知柏地黃湯加減), Esuntang(二仙湯), Ejihwan(二至丸加味), Sihogayonggolmoryutang(柴胡加龍骨牡蠣湯加減) are used. And the acupuncture points such as Conception Channel, the Spleen Channel, the Urinary Bladder Channel, the Kidney Channel which are related to the lower belly of woman.

  • PDF

The Effects of Solute Carbon Atoms in Ferrite on Austenitization and the Thermal Expansion Coefficients of Ferrite and Austenite (페라이트 내에 고용된 미량의 탄소가 오스테나이트화 거동 및 페라이트와 오스테나이트의 열팽창 계수에 미치는 영향)

  • Mun, Yumi;Park, Jihye;Kang, Singon;Jung, Jae-Gil;Lee, Sangmin;Lee, Young-Kook
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.26 no.6
    • /
    • pp.300-305
    • /
    • 2013
  • The effects of solute carbon atoms on the thermal expansion coefficients of ferrite and austenite as well as austenitization behavior were investigated by comparing carbon-free ferrite and carbon-containing ferrite. The thermal expansion coefficients and austenitization start and finish temperatures were measured using a dilatometer. Solute carbon atoms at elevated temperatures above the cementite dissolution temperature (650 K) decreased the thermal expansion coefficients of both ferrite and austenite. In addition, minute amount of carbon atoms dissolved in ferrite stimulated austenite nucleation during continuous heating, resulting in the lower starting temperature of austenitization.

A Study on the Microstructure of Melt-Quenched AISI 310 Stainless Steel (단롤법으로 제조한 AISI 310 스테인레스강의 급냉 조직에 관한 연구)

  • Choi, J.H.;Oh, M.S.;J., S.S.;Lee, Y.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.9 no.1
    • /
    • pp.19-26
    • /
    • 1996
  • Melt-quenching of steels leads to various metallographic effects such as refinement of grain size, extension of the solid solubility of carbon and alloying elements, and is expected to improve the mechanical properties of conventional steels. Furthermore, this technique is a useful method for producing sheet directly from liquid state. And it will lend itself to development as a continuous cast process which offers significant savings in energy and product costs. The purpose of this study is to present the microstructures of melt-quenched austenitic stainless steels. As the results of this study, the morphology of melt-quenched microstructure show that the roll contact area is columnar structure, and the free surface area is dendrite structure. As the line speed increases, the ratio of $d_{colunnar}/d_{total}$ increases from 0.12 to 0.60, but the ribbon thickness decreases from $150{\mu}m$ to $30{\mu}m$.

  • PDF

A Study on Wear Resistance and Surface Hardening of 3%Cr-Mo-V Steel by Two-step Gas Nitriding (3%Cr-Mo-V강의 2단 가스질화처리를 통한 표면경화 및 내마모성 연구)

  • Jung, G.B.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.22 no.6
    • /
    • pp.361-367
    • /
    • 2009
  • The two-step gas nitriding was adopted to increase the depth of surface hardening in 3%Cr-Mo-V steel. The two-step gas nitriding consisted of Step I; $520^{\circ}C{\times}20\;hrs$ and Step II; $550^{\circ}{\times}70\;hrs$. The layer of two-step gas nitriding showed better uniformity and deeper nitriding layer than one-step gas-nitriding layer. The maximum surface hardness showed the value of 850 Hv. The maximum depth of nitrogen permeation showed $750\;{\mu}m$ (350 Hv). X-ray diffraction analysis showed that compound layer was mainly consisted of CrN and $\varepsilon-Fe_3N$ phases. These phases were presumed contributing to surface hardening and wear resistance. However, the corrosion resistance of gas-nitrided Cr-Mo-V steel were not improved in the solution of 1 N HCl and NaOH. Therefore, it is necessary that the continuous study for improvement of corrosion resistance hereafter.

Changes in Microstructure and Texture during Annealing of 0.015% C-1.5% Mn-0~0.5% Mo Steels (0.015% C-1.5% Mn-0~0.5% Mo 강의 어닐링과정에서 미세조직과 집합조직의 변화)

  • Jeong, Woo Chang
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.24 no.5
    • /
    • pp.251-261
    • /
    • 2011
  • The changes in microstructure and texture during annealing were examined in a series of 0.015% C-1.5% Mn cold-rolled sheet steels with 0~0.5% Mo. Orientation distribution function data were calculated from the (110), (200), (211) pole figures determined on the rolled plane of cold-rolled and annealed steel sheets. Regardless of Mo content and annealing conditions, martensite volume fraction was less than 1.0%, not affecting the texture evolution. Textural change at the cooling stage after heating at $820^{\circ}C$ for 67 sec was not observed. Increasing the Mo content and annealing temperature markedly strengthened the intensities of ${\gamma}$-fiber texture, resulting in the increase in $r_m$ value. The desirable texture evolution for deep drawability in the 0.5% Mo steel may be mainly caused by the grain refining effect of Mo carbide in the hot-rolled steel sheet.

Changes in Hardness and Thermal Conductivity with Volume Fraction of Discontinuous Precipitates in Mg-Al Alloy (Mg-Al 합금에서 불연속 석출물의 부피 분율에 의한 경도 및 열전도도의 변화)

  • Jun, Joong-Hwan
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.34 no.6
    • /
    • pp.302-308
    • /
    • 2021
  • The aim of this study was to investigate the dependence of the hardness and thermal conductivity on the volume fraction of discontinuous precipitates (DPs) in the Mg-9.3%Al alloy with (α-(Mg)+DPs) dual phase structure. In order to obtain various DPs volume fractions, the alloy was solution-treated at 688 K for 24 h and then aged at 418 K for up to 144 h. The volume fraction of DPs increased from 0% to 63% with an increase in the aging time up to 72 h, over which, continuous precipitation was observed within the α-(Mg) grains. It is noticeable that the hardness and thermal conductivity of the alloy increased linearly with the volume fraction of DPs. The improved hardness and thermal conductivity with respect to volume fraction of DPs are closely associated with the higher hardness of the DPs with fine (α+β) lamellar structure and the lower Al concentration in the α phase layer of the DPs, respectively.

A Study on the heat generation during implant abutment preparation (임플란트 지대주 삭제시의 발생열에 관한 연구)

  • Lee, Ho-Jin;Song, Kwang-Yeob;Jang, Tae-Yeob
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.1
    • /
    • pp.27-33
    • /
    • 2003
  • Excessive heat generation at the implant-bone interface may cause irreversible bone damage and loss of osseointegration. The effect of heat generation in vitro at the implant surface caused by abutment reduction with high-speed dental turbine was examined. Titanium-alloy abutments connected to a titanium alloy screw-implant embedded in an acrylic-resin block in a $37^{\circ}C$ water bath were prepared. Temperature changes were recorded via embedded thermocouples at the cervix and apex of the implant surface. Analysis of variance for repeated measures was used to compare seven treatment groups. Fifty seconds of continuous cutting with air and water coolant caused a mean temperature increase of $1.24^{\circ}C$ at apex and $5.77^{\circ}C$ at cervix. Similar intermittent cutting caused increase of $2.50^{\circ}C$ at apex and $1.64^{\circ}C$ at cervix. But, continuous cutting with air coolant caused a mean temperature increase of $6.47^{\circ}C$ at apex and $5.77^{\circ}C$ at cervix. Similar intermittent cutting caused increase of $6.47^{\circ}C$ at apex and $5.77^{\circ}C$ at cervix. Preparation of implant abutment does not lead to detrimental effect on peri-implant tissues provided that adequate cooling. However, without water cooling, extreme overheating could be provoked, reaching the critical temperature that would lead to irreversible bone damage within only a few seconds.

Effects of extreme heat stress and continuous lighting on growth performance and blood lipid in broiler chickens (연속조명과 폭염 스트레스가 육계의 혈액지질 및 성장능력에 미치는 영향)

  • Park, Sang-Oh;Hwangbo, Jong;Ryu, Chae-Min;Yoon, Jae-Sung;Park, Byung-Sung;Kang, Hwan-Ku;Seo, Ok-Suk;Chae, Hyun-Seok;Choi, Hee-Chul;Choi, Yang-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.78-87
    • /
    • 2013
  • In this study, the effect of extreme heat diet on growth performance, lymphoid organ, blood immunoglobulin and cecum microflora change in broilers exposed to continuous lighting and extreme heat stress (EHS) was studied. Broilers raised under normal environment temperature ($25^{\circ}C$ or extreme heat stress temperature ($33{\pm}2^{\circ}C$, and consumed chow diet (CD) or extreme heat stress diet (EHSD). Five hundred Ross 308 day-old commercial broilers were arranged in a completely randomized block design of 5 treatment groups with 4 repetitions (25 heads per repetition pen). The broilers were divided into: T1 (normal environment+CD), T2 (EHS+CD), T3 (EHS+EHSD in which the tallow in CD was substituted by soy oil and contained 5% molasses), T4 (EHS+EHSD in which the tallow in CD was substituted by soy oil and contained 5% molasses, and 1.5 times more methionine and lysine than CD), and T5 (EHS+EHSD in which the tallow in CD was substituted by soy oil, contained 5% molasses, 1.5 times more methionine and lysine than CD, and 300ppm of vitamin C). The EHS significantly reduced the body weight gain and feed intake. The blood immunoglobulin, bursa of Fabricius, thymus, and spleen weight were significantly reduced when broilers were exposed to EHS. Compared to the normal environment temperature group, the cecum Lactobacillus sp. was low in the EHS treatment group, while Escherichia sp., Salmonella sp. and total aerobic bacteria in the EHS treatment group were high. A statistically significant difference was acknowledged between the treatment groups.