• 제목/요약/키워드: continuous flow-through system

검색결과 138건 처리시간 0.033초

대기오염의 확산 연구를 위한 산성 오염물질의 연속 측정법의 개발 (Development of Continuous Monitoring System of Acidic Pollutants for The Studies of Their Diffusion in The Atmosphere)

  • 정형근;피.케이. 다스쿱타;이대운
    • 분석과학
    • /
    • 제5권3호
    • /
    • pp.269-276
    • /
    • 1992
  • An ion-exchange/conductometric method is applied for the determination of total acidity in simulated atmospheric samples. Non-$H^+$ cations and strong acid anions are enriched by the preconcentrator columns in series and eluted through the corresponding parallel suppressor units. The conductivities from each channel correspond to the concentrations of the resulting ionized species in equivalents per unit volume. The difference is the measure of acidity due to strong acids. With 5-min sampling at a flow rate of 0.3 mL/min, the detection limits for ${NH_4}^+$ and ${SO_4}^{2-}$ are 0.3 and $0.1{\mu}equiv/L$, respectively. The acidity for samples composed of various ions can be determined without significant error, usually less than 5%. The proposed method discriminates against the artifact from the $CO_2$ dissolution. Principles of acidity measurements are also presented.

  • PDF

퇴비화 암모니아 가스의 톱밥 바이오 필터 매체에 의한 생물학적 탈취 (Biofiltration of Ammonia Gas from Composting Using Sawdust as Biofilter Media)

  • Hong Ji Hyung;Park Keum Joo
    • 한국농공학회지
    • /
    • 제45권2호
    • /
    • pp.107-115
    • /
    • 2003
  • Dairy manure amended with crop and forest residues (moisture 69% wet basis, C/N 22) was composted in a 605 L pilot-scale vessel using continuous air flow (56 L/min) for 19 days. Three pilot-scale sawdust biofilters (moisture 63%, pH 5.0) were built to clean biological waste gas from the composting process. For each methods, two replicated experiments were monitored over a period of three weeks. The system was evaluated to determine the biofilter media depth that would be adequate for compost odour reduction. The compost air cleaning was measured based on ammonia gas concentration before and after passing through the biofilter. Ammonia gas removal efficiency over 3 weeks was 42, 75 and 87% at sawdust biofilter media depth levels of 202, 400 and 600 mm, respectively. Each sawdust biofilter was operated at a moisture content in the range of 60~62% (wb), a temperature from 15 to $25^{\circ}C$, an average pressure drop from 240 to 340 Pa and a detention time from 60 to 180 seconds during the biofiltration process.

PPTC 소자를 사용한 저전압 직류차단기의 아크소호기술 (Arc Extinguishment for Low-voltage DC (LVDC) Circuit Breaker by PPTC Device)

  • 김용중;나재호;김효성
    • 전력전자학회논문지
    • /
    • 제23권5호
    • /
    • pp.299-304
    • /
    • 2018
  • An ideal circuit breaker should supply electric power to loads without losses in a conduction state and completely isolate the load from the power source by providing insulation strength in a break state. Fault current is relatively easy to break in an Alternating Current (AC) circuit breaker because the AC current becomes zero at every half cycle. However, fault current in DC circuit breaker (DCCB) should be reduced by generating a high arc voltage at the breaker contact point. Large fire may occur if the DCCB does not take sufficient arc voltage and allows the continuous flow of the arc fault current with high temperature. A semiconductor circuit breaker with a power electronic device has many advantages. These advantages include quick breaking time, lack of arc generation, and lower noise than mechanical circuit breakers. However, a large load capacity cannot be applied because of large conduction loss. An extinguishing technology of DCCB with polymeric positive temperature coefficient (PPTC) device is proposed and evaluated through experiments in this study to take advantage of low conduction loss of mechanical circuit breaker and arcless breaking characteristic of semiconductor devices.

자동연속측정시스템 개발 및 이 시스템을 이용한 서울 대기 중 PM2.5의 화학적 조성과 특성에 관한 연구 (Development of an Automated and Continuous Analysis System for PM2.5 and Chemical Characterization of the PM2.5 in the Atmosphere at Seoul)

  • 이보경;김영훈;하재윤;이동수
    • 한국대기환경학회지
    • /
    • 제21권4호
    • /
    • pp.439-458
    • /
    • 2005
  • An automated analysis system for water soluble constituents in $PM_{2.5}$ has been developed. The system consists of a high capacity multi tube diffusion scrubber (MTDS), a low temperature particle impactor (LTPI), and two ion (anion and cation) chromatography (IC) systems. Atmospheric particles have been collected by passing sample air through a thermostated MTDS followed by a LTPI. This system allows simultaneous measurements of soluble ions in $PM_{2.5}$ at 30 minutes interval. At the air sampling flow rate of 1.0L/min, the detection limits of the overall system are in the order of tens of $ng/m^3$. This system has been successfully used for the measurement of particulate components of Seoul air from April 2003 to January 2004. $SO_4^{2-},\;NO_3^-,\;NH_4^+,\;NO_2^-,\;Cl^-,\;Na^+,\;K^+,\;Ca^{2+},\;and\;Mg^{2+}$ are the major ionic species for $PM_{2.5}$ at Seoul. Among them, $SO_4^{2-},\;NO_3^-\;and\;NH_4^+$ are the most abundant ions, contributed up to $86\%$ of the total and the concentrations were higher than those in any other urban sites in the world except for Chinese cities. There are high pollutant episodes which contribute about $15\~20\%$ of annual average values of the major ions. During the episode, the all parcels were transported from the asian continent and $PM_{2.5}$ were significantly neutralized. This suggests that aged and long range transported pollutants caused the high pollutant episodes. They showed a distinct daily and seasonal variations:they showed a peak in the early morning caused by the night-time accumulation of particulate matters. Atmospheric reactions including gas-to-particle reactions and inter-particle reactions and meteorological parameters including relative humidity and ambient temperature were described with related to the $PM_{2.5}$ 5 concentrations. All of the ionic species showed higher concentrations during the spring than those for summer and winter.

세포 배양액의 연속 공급기 제작을 통한 심근세포의 성숙개선에 관한 연구 (A study on the maturation of cardiomyocytes by continuous supply of culture media)

  • 권우진;김근우;정운선;김종윤;이동원
    • 센서학회지
    • /
    • 제30권2호
    • /
    • pp.109-113
    • /
    • 2021
  • In this study, an automated culture media replacement system was developed to analyze changes in the contraction characteristics of cardiomyocytes according to the state of the culture media. For the long-term storage of culture media, a Peltier refrigerator with a temperature of 5 to 8℃ was provided and a pH of 7.4 was maintained. The cell culture media of the cardiomyocytes was continuously replaced using interlocking pumps at a flow rate of 0.83 μl/h. The cardiomyocytes in which the culture media was replaced automatically demonstrated lower heartbeats per minute compared to samples in which there was no replacement. However, these cardiomyocytes moved more uniformly and produced greater displacement in one heartbeat cycle. It was observed that the sarcomere length of the cardiomyocytes increased due to the automated culture media replacement system. These cardiomyocytes were found to demonstrate better maturation compared to the control group. The maturation of cardiomyocytes was verified through staining images. The proposed automated culture media replacement system generates a uniform heart rate and improvements in contraction force. Based on the study, patient-specific drug toxicity assessments can be conducted using differentiated cardiomyocytes in induced pluripotent stem cells.

동전기-펜턴 공정을 이용한 phenanthrene 오염토양의 정화 (Electrokinetic-Fenton Process for Removal of Phenanthrene)

  • 양지원;박지연;김상준;이유진;기대정
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제9권1호
    • /
    • pp.47-53
    • /
    • 2004
  • 본 연구에서는 동전기-펜턴 공정을 이용한 phenanthrene 오염토양 정화의 타당성을 확인하기 위해서, 토양 시스템 내에서 전기삼투흐름에 의한 과산화수소의 이동과 펜턴유사 반응에 의한 phenanthrene의 산화분해 양상을 살펴보았다. 10 mA와 5 mA의 두 가지 전류 조건 중에서, 10 mA일 때 더 높은 전압경사와 전기삼투유량이 관찰되었다. 높은 전기삼투유량은 토양 내로 많은 양의 과산화수소가 이동한 것을 의미하므로, phenanthrene 제거효율이 전기삼투유량이 증가함에 따라 증가한 것으로 판단된다. 동전기 정화기술만을 이용한 토양 세척에 의해 7일간의 가동기간 동안 8.5%의 phenanthrene이 제거되었다. Phenanthrene을 직접 산화분해하기 위하여 양극 전극조를 통하여 과산화수소 용액을 토양에 공급한 경우에는 14일 동안 최고 95.6%의 제거효율을 얻을 수 있었다. 실험 종료 후 95.6%의 제거효율을 나타낸 토양시료를 분석한 결과 phenanthrene의 중간산물이 거의 관찰되지 않음으로써, 과산화수소의 연속적인 주입을 통하여 가동기간 중간에 생성된 중간산물들이 저분자 물질로 산화분해 되었거나 물과 이산화탄소로 분해된 것으로 추정된다.

지반보강재로서 폐타이어 사용에 따른 환경영향 분석 (Environmental Characteristics of Waste Tire for Use as Soil Reinforcement)

  • 조진우;이용수
    • 한국지반환경공학회 논문집
    • /
    • 제14권1호
    • /
    • pp.61-68
    • /
    • 2013
  • 본 연구에서는 지반보강재로서 폐타이어 사용에 따른 환경영향을 평가하기 위하여 실내실험 및 현장시험시공을 수행하였다. 실내실험을 통하여 폐타이어의 용출특성에 가장 큰 영향을 미치는 폐타이어의 입경과 배수조건을 변화시켜가며 유출수의 pH, 탁도, TOC, Zn 농도를 분석하였다. 또한, 현장시험시공을 통하여 폐타이어를 이용한 보강토 옹벽 시공 후 하부 집수정의 수질을 분석하였다. 입경에 따른 용출실험 결과 폐타이어 입경이 증가할수록 용출농도가 감소하는 것을 확인할 수 있었으며, 이는 비표면적의 차이 때문으로 판단된다. 배수조건에 따른 용출실험 결과 배수조건인 경우 시간이 경과할수록 용출농도가 감소하여 주변 환경에 큰 영향을 미치지 않을 것으로 판단되나, 비배수 조건인 경우 시간이 경과할수록 용출농도가 증가하는 현상을 발견할 수 있었다. 1년간의 현장모니터링 결과 폐타이어로 보강된 옹벽으로부터 발생되는 침출수는 전반적으로 용출농도가 높지 않은 것으로 나타났으며, 침출수 발생 초기에 농도가 증가하다가 이후 점점 감소하여 원수인 우수와 비슷해지는 경향을 나타내었다. 따라서 폐타이어를 지반보강재로 사용함에 따라 발생하는 환경적 영향은 무시할 수 있는 수준임을 알 수 있었다.

X선 영상 장치를 이용한 핵연료 집합체 내 기포율 측정을 위한 선행 연구 (A Preliminary Study on Measuring Void Fraction in a Fuel Rod Assembly by using an X-ray Imaging System)

  • 이선영;오오성;이세호;이승욱
    • 한국방사선학회논문지
    • /
    • 제11권7호
    • /
    • pp.571-578
    • /
    • 2017
  • 원자로 내 사고발생 시 냉각수의 비등으로 기포가 발생하고, 기포율을 측정하기 위하여 열수력 안전 분야에서는 주로 Optical Fiber Probe(OFP)나 광학 카메라를 이용하여 측정하지만 기하학적 구조의 한계로 인해 $17{\times}17$ 배열의 봉 다발 내에 장비를 설치하는 것에는 어려움이 있다. 본 연구는 예비 연구로서 봉 다발에 적용하기 전 X선 시스템과 다양한 모사 팬텀을 이용하여 연구 가능성 평가를 수행하였다. 라디오그라피 및 토모그라피 실험을 통해 X선 발생 장치의 관전압 130 kVp, 관전류 1 mA가 적합하였다. 또한, 기포 해상도 팬텀을 통해 가시적으로 1 mm 크기의 구멍에 대해 측정이 가능하였으며 막대 팬텀을 이용한 대조도 평가의 경우 프레온 내부에서 대조도가 상대적으로 떨어짐을 확인할 수 있었다. 그러나 영상 재구성 시 일그러짐이 없는 좋은 영상을 획득할 수 있었다. 기포 발생 팬텀 실험을 통해 기포의 유동 방향 확인 및 단층 영상을 획득할 수 있었고, Image J 툴을 이용하여 하나의 단층영상에 대해 18 %의 기포율을 측정할 수 있었다. 본 연구는 핵연료 주변 기포율 측정을 위한 선행 연구를 수행하였고 지속적인 연구를 위한 기초 연구로서 활용할 수 있을 것이다.

모바일 게임 플랫폼 평가 및 플로우경험이 게임사용자의 애호도에 미치는 영향 (The Effect of Game Platform Evaluation and Flow Experience on Player Loyalty in Mobile Game Application)

  • 오세구
    • 한국콘텐츠학회논문지
    • /
    • 제20권3호
    • /
    • pp.235-244
    • /
    • 2020
  • 4차 산업시대에 모바일 게임은 하루에도 수백 가지의 게임이 출시되는 등 경쟁이 치열하지만 매우 수익성이 높은 산업이다. 성공적인 모바일 게임을 제작하기 위해서는 모바일환경 및 모바일시대의 소비자에 대한 이해가 필요하며, 다양한 요인 중 어떤 점을 중시해야 하는가에 대한 시사점을 제공할 수 있는 연구가 필요하다. 본 연구에서는 모바일 게임의 성공에 영향을 미치는 게임 내·외적 요인을 탐색하고 이 요인들과 고객 만족 및 애호도 간의 관계를 살펴봄으로써 게임제작자들이 게임 제작 시 도움이 될 시사점을 제공하고자 하였다. 분석 결과, 게임 플랫폼의 시스템 및 서비스 품질은 평가에 긍정적인 영향을 미치며, 가격정책의 경우 평가에 유의한 영향을 미치지 못하는 것으로 나타났다. 또한, 플로우 요인에서는 목표와 상호작용(관계 형성)이 플로우에 정(+)의 영향을 주며, 스킬이나 도전 의식은 유의한 영향을 주지 않는 것으로 나타났다. 플로우와 플랫폼 평가가 고객 애호도에 미치는 영향은 모두 정(+)의 영향을 미치는 것으로 나타났다. 기업은 첫째, 고객과의 지속적인 상호작용을 통하여 게임에 대한 고객의 의견과 행위를 이끌어 내야 하며, 둘째, 게임상에서 고객에게 적절한 목표를 부여하고, 이용자 간 상호작용이 가능하도록 하는 기능을 부여한다면 보다 성공적인 게임을 개발 할 수 있을 것이다.

연속회분식 반응 장치에서 Ferrate를 이용한 Cu(II)-EDTA 함유 폐수 처리 연구 (Treatment of Wastewater Containing Cu(II)-EDTA Using Ferrate in Sequencing Batch Scale System)

  • 김형욱;김병권;이승목;양재규;김현욱;권정안;임항식
    • 대한환경공학회지
    • /
    • 제30권7호
    • /
    • pp.729-734
    • /
    • 2008
  • 높은 산화상태를 갖는 철화합물인 ferrate(Fe$^{6+}$)를 Cu(II)-EDTA가 오염된 폐수를 처리하는데 적용하였다. Fe(VI)는 3가 철염에 차아염소산을 가하여 습식 산화시키는 방법을 적용하여 제조하였으며 93% 이상의 순도를 얻을 수 있었다. 용액에서의 Fe(VI)의 안정성은 pH가 낮을수록 자체분해반응이 가속화됨으로써 감소하는 것으로 나타났다. 자외선-가시광선 분광광도계를 사용하여 Fe(VI)의 환원정도를 측정하였다. 실험실규모의 연속회분식 반응장치를 Cu(II)-EDTA 함유 폐수처리에 적용함으로서 Cu(II)-EDTA의 산화특성, Fe(III)에 대한 구리이온의 거동 특성 그리고 유기물의 제거능을 조사하였다. 연속처리를 위한 반응조 및 pH 조정조에서 총 구리의 제거는 체류시간 120분에서 각각 69% 및 75%로서 최대 제거율을 보였으며 체류시간 120분 경과 후 Cu(II)-EDTA의 비착물화 정도는 80% 이상을 보였다. 본 연구를 통하여 Fe(VI)를 다기능성 처리제로서 사용하여 Cu(II)와 EDTA가 함께 존재하는 폐수를 연속적으로 처리하는 공정을 개발하였다.