• Title/Summary/Keyword: continuous dryer

Search Result 30, Processing Time 0.023 seconds

Development of Continuous Cross-Flow Rice Drying Model (벼의 횡류 연속식 건조 모델 개발)

  • 송대빈;고학균
    • Journal of Biosystems Engineering
    • /
    • v.22 no.3
    • /
    • pp.279-288
    • /
    • 1997
  • This study was worked out to obtain fundamental data needed for developing a continuous type dryer. The drying process in a cross-flow type continuous dryer was expressed as partial differential equations, and a drying simulation model for predicting rice moisture content, rice temperature, drying air absolute humidity, drying air temperature was developed by using the finite difference method. To validate the performance of the drying simulation model, a prototype continuous dryer was constructed in this study. The size of the test dryer was one-tenth to that of a commercial continuous dryer. The difference in the outlet rice moisture content between the predicted values and the measured values was within 0.5%, that of outlet rice temperature was below $3^{\circ}C$, that of drying air temperature in drying bed was within $8^{\circ}C$ and that of relative humidity of outlet drying air was big because of the different measuring point. In addition, a drying simulation model for a actual size continuous dryer with double flow was developed in this study. This drying simulation model included the rice mixing effect in the middle of drying length. The difference of outlet moisture content between the predicted and the measured values showed below 0.5% in this study.

  • PDF

Development of a Prototype Continuous Flow Dryer using For Infrared Ray and Heated -air for White Ginseng (열풍과 원적외선 겸용 연속식 백삼 건조기의 개발)

  • 박승제;김성민;김명호;김철수;이종호
    • Journal of Biosystems Engineering
    • /
    • v.25 no.2
    • /
    • pp.115-122
    • /
    • 2000
  • This study was performed to develop a prototype continuous flow ginseng dryer with which better product quality and lower drying energy consumption could be achieved compared with conventional ginseng dryers. A dryer having both far infrared ray (IR) and heated-air as the drying energy sources was designed and fabricated . Dryer performance was studied by examining energy efficiencies and dryer performance evaluation indices (DPEI) during the drying tests of medium-sized four year ginseng roots with IR radiating plate temperature and drying air temperature in the range of 80-12$0^{\circ}C$ and 22-5$0^{\circ}C$, respectively. The DPEI of IR /heated -air combined drying was 1/3 of that of the conventional heated-air drying when ginseng were dried to the same final moisture ratio. When ginsengs were dried for 12 hours in the prototype IR/heated-air combination dryer, a linear relationship was found to exist between final moisture ratio and ginseng temperature. As the drying progressed, drying air temperature inside the dryer was nearly constant but ginseng temperature was drastically increased during the first two hours and gradually increased thereafter until the end of drying. With the prototype Ir/heated-air combination dryer, the drying rate changed little but the energy efficiency increased proportionally when the amount of ginseng to be dried increased. Drying capacity, energy efficiency, and DPEI of the prototype IR/heated-air combination ginseng dryer were estimated to 1.500 roots, 65% and 3.800kJ/kg-water , respectively.

  • PDF

Drying Characteristics of Rough Rice in Continuous Dryer

  • Song, D.B.;Koh, H.K.;Keum, D.H.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.863-877
    • /
    • 1996
  • A drying model to predict the drying process in continuous dryer was developed and proved by drying experiments. The experiment showed that the difference of moisture contents between the predicted and the observed was within 0.5%(wb). There was no cracked rice found even in high drying rate with the inlet moisture content over 23%(wb), and tempering treatment in the same temperature reduced the ratio of cracked rice. There was a little difference in the ratio of cracked rice between 40$^{\circ}C$ and 45$^{\circ}C$ drying temperatures with the final drying moisture content (14.5% wb), and the cracked rice increased at 55$^{\circ}C$. As a results, it was better to make fast drying on the rice over 23%(wb) inlet content it was recommended to keep drying at 45$^{\circ}C$.

  • PDF

Development of Fuzzy Control System For Uniform Drying in Continuous Dryer

  • Song, D.B.;H.K.Koh;Cho, S.I.;Lee, J.H.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.668-678
    • /
    • 1996
  • A control system using fuzzy logic for a large capacity continuous dryer has been developed in order to minimize the damage of rice quality. The system has been verified in the case of 17% of object moisture content. With the initial input moisture contents of 20.46%(wb), 20.96%(wb) and 18.98%(wb), the final moisture contents of 17.99%(wb), 17.6%(wb) and 17.23%(wb) are obtained, respectively. The results show that the system controls the moisture content with the maximum error of 0.99% of the object moisture content.

  • PDF

DEVELOPMENT of CONTINUOUS GRAIN DRYER

  • Kim, Y.H.;Cho, Y.K.;Cho, K.H.;Keum, D.H.;Han, C.S.;Han, J.K.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.396-404
    • /
    • 2000
  • Post harvest processes for rice include drying, storage and processing. Drying has a great effect on the quality of the grain. The existing rice centers are with the ill equipped, especially with drying and storage facilities. The rice harvesting has bully mechanized, a large volume of rice with high moisture content are taken to the rice processing complex(RPC). Three, the need for drying and storage facilities becomes more urgent. At present the daily drying capacity of RPC can't exceed over 40~50 M/T. Therefore new technology and facilities for a high quality and main efficient drying should be introduced one such technology is the continuous flow drying system. This research, aims to test performance efficiency the mixed continuous flow grain dryer was whose daily drying capacity is 100 M/T. The results of the performance tests of the dryer are shown as follows; (1) The temperature distribution of the drying modules were measured by a temperature recorder. The fifth module showed the highest value, followed by the seventh and the third. (2) When the intake air temperature was $55^{circ}C$, the drying rates were 1.7 and 2.6%, wb/pass in the exhaust temperatures of 20 and $22^{circ}C$. And when the intake air temperature was $60^{circ}C$, the drying rates were 1.7 and 2.3%, wb/pass in the exhaust temperatures of 22 and $25^{circ}C$. (3) The average increased rate of cracked grains after the drying process was 0.7% which is below the tolerance limit (2.0%) of the continuous grain dryer.

  • PDF

Study on the Drying Characteristics of Band Dryer using Impingement Jet Stream (충돌제트기류를 이용한 밴드건조기의 건조특성에 관한 연구)

  • Kim, S.I.;Lee, W.H.;Chun, W.P.;Lee, K.W.;Lee, K.J.
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.1931-1936
    • /
    • 2007
  • The application of high velocity air jets to heat transfer surface has tremendous engineering potential in various industries. The impinging jets are therefore widely used for their enhanced transport characteristics, especially for drying of continuous materials such as sheet, film, carpets, forming materials and pallets. This paper presents the drying characteristics of plate type material and performs the test with the change of operating conditions in conveyer band dryer using the impinging jet nozzles. The factors influencing drying rate were confirmed, also the design data of band dryer using the impinging jet was obtained.

  • PDF

A Study on the Performance Optimization of a Continuous Monitoring Method for Hazardous VOCs in the Ambient Atmosphere (환경대기 중 유해성 VOC에 대한 자동연속 측정방법의 성능 최적화에 관한 연구)

  • Son, Eun-Seong;Seo, Young-Kyo;Lee, Dong-Hyun;Lee, Min-Do;Han, Jin-Seok;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.6
    • /
    • pp.523-538
    • /
    • 2009
  • Recently, there has been a keen demand for real-time automatic monitoring of VOCs not only in Korea but other developed countries. We carried out this study to evaluate and to optimize the performance of a continuous automatic monitoring system for hazardous VOCs (HVOCs) in the ambient atmosphere, using an on-line GC system. The online system normally consisted of a Nafion dryer prior to a cold trap of an automatic thermal desorption apparatus and a GC system equipped with two detectors, i.e. PID and ECD. Preliminary tests conducted to check out any contamination of the system revealed an evidence of significant artifact formation of benzene, and it was found that the Nafion dryer (even brand new one) is the source of the benzene artifact. Thus, all the subsequent experiments in this study was carried out inevitably by removing the Nafion dryer. The on-line GC method was investigated with a variety of QC/QA performance criteria such as repeatability, linearity, lower detection limits, and accuracy. In order to find out the best operating condition for the on-line GC system, three different types (in terms of adsorption strength) of cold trap combinations were tested, i.e. (i) Tenax-TA and Carbopack-B combination (weak and hydrophobic); (ii) Tenax-TA, Carbopack-X and Carboxen-1000 combination (strong and hydrophilic); and (iii) Tenax-TA and Carbopack-X combination (medium and hydrophobic/hydrophilic). The USEPA TO-17 manual method was selected as a reference method to evaluate the performance of the on-line method. A series of experiments revealed that the system performance was superior to others when a cold trap packed with hydrophilic adsorbents (Tenax-TA/Carbopack-X/Carboxen-1000 combination) was used and operated at $25^{\circ}C$. However, the system with a cold trap packed with a combination of Tenax-TA and Carbopack-X is more recommended for field applications since the carboxen-1000 adsorbent is too sensitive to water vapor, and hence the performance of the system might be very unstable to humid samples or during rainy days. Furthermore, the precision and accuracy criteria of the Tenax-TA/ Carbopack-X combination were generally compatible with the triple adsorbents cold trap. The continuous automatic monitoring method is, thus, considered very useful to real-time monitoring to understand the variations of VOCs concentrations in ambient air, as it adopts much simpler procedures in sampling, analysis, and data integration steps than manual monitoring methods. However, it should be noted that there is a high possibility of benzene artifacts formation through the Nafion dryer, which is often installed to remove water vapor in air samples before being adsorbed onto the cold trap. Therefore, if a Nafion dryer is used in any studies of monitoring VOCs, the benzene contamination should be carefully examined before carrying out obtaining the data.

Reuse of Exhaust Heat and Improvement in Fuel Efficiency of Grain Dryer (곡물(穀物) 건조기(乾燥機)의 배기열(排気熱) 재이용(再利用) 및 열효율(熱効率) 개선(改善)에 관(關)한 연구(硏究))

  • Keum, Dong Hyuk;Lee, Yong Kook;Lee, Kyou Seung;Han, Jong Ho
    • Journal of Biosystems Engineering
    • /
    • v.9 no.2
    • /
    • pp.65-73
    • /
    • 1984
  • While most of researches on the performance of high temperature grain dryer have dealt mainly with improving dryer capacity and drying speed during the last twenty years, energy efficiency, in fact, has not been emphasized. Current fuel supplies and energy cost have shifted the emphasis to reducing the energy consumption for grain drying while maintaining dryer capacity and grain quality. Since the energy input for drying is relatively large, the recovery and reuse of at least part of the exhaust energy can significantly reduce the total energy consumption in existing drying systems. Unilization of exhaust heat in grain dryer either through direct recycling or by a thermal coupling in heat exchanger have been subject of a number of investigators. However, very seldom research in Korea has been done in this area. Three drying tests(non-recycling, 0.22 recycle ratio, and 0.76 recycle ratio)were performed to investigate the thermal efficiency and heat loss factors of continuous flow type dryer, and to analyze the effect of recycle ratio (weight of exhaust air recycled/total weight of input air) on the energy requriements for rough rice drying. The test results showed that when the exhaust air was not recycled, the energy lost from furnace was 15.3 percent of input fuel energy, and latent and sensible heat of exhaust air were 61.4 percent and 11.2 percent respectively. The heat which was required in raising grain temperature and stored in dryer was relatively small. As the recycle ratio of exhaust air was increased, the drying rate was suddenly decreased, and thermal efficiency of the kerosene burner was also decreased. Drying test with 0.76 recycle ratio resulted in 12.4% increase in fuel consumption, and 38.4% increase in electric power consumption as compared to the non-recycled drying test. Drying test of 0.22 recycle ratio resulted in 6.8% saving in total energy consumption, 8.0% reduction in fuel consumption, and 2.5% increase in electric power consumption as compared to the non-recycled drying test.

  • PDF