• Title/Summary/Keyword: contamination sources

Search Result 368, Processing Time 0.025 seconds

Building a Classification Scheme of Soil and Groundwater Contamination Sources in Korea: 2. Construction of Classification System and Applications of Attribute Data (토양.지하수오염원 분류체계 구축방안: 2. 분류체계 구축 및 속성자료 활용방안)

  • An, Jeong-Yi;Shin, Kyung-Hee;Hwang, Sang-Il
    • Journal of Soil and Groundwater Environment
    • /
    • v.15 no.6
    • /
    • pp.122-127
    • /
    • 2010
  • Constructing the national inventory that can be used as a tool to identify and assess existing or potential contamination is necessary for efficiently managing the soil and groundwater contamination. In order to start this construction, the first step is how we define and classify potential contamination sources of soil and groundwater. After selecting the basic classification model of contamination sources from developed countries, we suggested the classification and list of the potential contamination sources of soil and groundwater which are appropriate for specific conditions of South Korea. In addition, we investigated several databases to confirm the existence of available data sources and then examined established attribute data through chemical accident response information system (CARIS) and water information system (WIS) in National Institute of Environmental Research and mine geographic information system (MGIS) in Mine Reclamation Corporation. All sorts of attribute data in the existing databases can be utilized as significant assessment factors for determining the management priority of potential contamination sources in the future. Therefore, it is required the expanded investigation of additional database sources and the continual modification so that the classification system of potential contamination sources can be improved.

Building a Classification Scheme of Soil and Groundwater Contamination Sources in Korea: 1. State-of-the-Art and Suggestions (토양.지하수오염원 분류체계 구축방안: 1. 국내외 현황 및 시사점)

  • An, Jeong-Yi;Shin, Kyung-Hee;Hwang, Sang-Il
    • Journal of Soil and Groundwater Environment
    • /
    • v.15 no.6
    • /
    • pp.64-71
    • /
    • 2010
  • National inventory of soil and groundwater contamination is an efficient decision-making tool to identify and manage existing or potential contaminated sources and contaminants. It has been used as basic data for establishing the scheme of regulations and remediation plans of soil and groundwater contamination in developed countries. This study examined classification of existing or potential sources of soil and groundwater contamination from various countries to suggest implications that required for development of classification of soil and groundwater contamination sources in Korea. Each country has provided a list of currently or potentially contaminating activities or landuses and identified some of the potential contaminants related to those contamination sources. Consideration of sources which had not been mentioned or regarded as contamination sources before was suggested for Korea situation. In addition, it is necessary to compile a list of existing data and information as much as possible to develop a detailed and practical list of various contamination sources.

Numerical evaluation of risk rates for contamination sources in a minienvironment (클린룸 국소환경에서 오염원의 위험율에 대한 수치해석적 평가)

  • Noh, Kwang-Chul
    • Particle and aerosol research
    • /
    • v.14 no.4
    • /
    • pp.181-189
    • /
    • 2018
  • In this study, the risk rates of different contamination sources of the contaminant in a minienvironment were analyzed through Computational Fluid Dynamics (CFD) simulation. The airflow pattern characteristics can only predict the qualitative variation of contaminant concentration, but cannot evaluate the quantitative variations in the risk rate of sources. From the results, the ambient contamination sources mainly affect wafers in the Front Opening Unified Pod (FOUP), whereas the internal contamination sources mainly affect wafers laid on the robot arm in the minienvironment. And the purging plenum system is very useful in protecting the wafers in the FOUP from contaminants transferred from the Fan Filter Unit (FFU). However, this system is unable to protect the wafers on the robot arm from internal contaminants and the wafers in the FOUP from sources of the interface between the FOUP and the minienvironment.

A Study on the Drinking Water Quality and Contamination Sources in a Rural Area (일부 농촌지역의 오염원 현황과 먹는 물 수질에 관한 조사연구)

  • 김탁수;이용미;김문선;김성연;신해철;최경호;정문호
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.2
    • /
    • pp.98-103
    • /
    • 2004
  • To evaluate the quality of drinking water and contamination sources in a rural community, this study was carried out on the summer of 2003 at Shin-Dong Myun, Chun-Cheon, Gang-Won province. Seventy three drinking water samples were collected from three different types of water supply systems. Sources of contamination were identified and the public perception of water quality area were evaluated. The findings of this study are as follows; Drinking water was mainly obtained from Local Water and Simple Piped Water Supply Systems, and pollution sources varied over the study area. Most of residents (>63%) were satisfied with the quality of drinking water and could not identify any contamination sources. Corresponding to this perception, measured water quality parameters generally met the Drinking Water Quality Standards (>64%). However, approximately 35.6% of samples exceeded the regulation for Nㅒ$_3$$^{-}$$_{-}$N, coliform, and general bacteria. The water quality was significantly different among the three water supply systems, and between the potentially contaminated areas and the rest of the areas (p<0.05). In the potentially contaminated areas, the levels of coliform and general bacteria contamination were significantly higher than the rest of the areas (p<0.05). The coliform and general bacteria values of Simple Piped Water were significantly higher than Own Piped Water's, and the NO$_3$$^{-}$$_{-}$N values of Own Piped Water were significantly higher than those of water's (p<0.05). Based on this study, NO$_3$$^{-}$$_{-}$N, coliform, and general bacteria were identified as a major problem of drinking water. To regularly manage drinking water supply systems, to identify contamination sources, and to add drainage systems are required in the study area.

Development of Preliminary Assessment Methodology for Priority Listing of Soil and Groundwater Contamination Sources (토양.지하수오염원 관리우선순위 개략평가기법 개발)

  • Jeong, Seung-Woo;Kim, Young-Ju;Kim, Jae-Hoon;Hwang, Sang-Il
    • Journal of Soil and Groundwater Environment
    • /
    • v.16 no.6
    • /
    • pp.106-112
    • /
    • 2011
  • This study developed preliminary assessment methodology for priority listing of soil and groundwater contamination sources, considering source characteristics, local environments and risk receptors. Source characteristics were evaluated by scoring relative risk of contamination sources. Local environments were evaluated by scoring annual rainfall, hydraulic conductivity of aquifer, and annual groundwater use. Risk receptors were evaluated by scoring local population, direct distance to surface water, direct distance to drinking-water wells. Scores of each parameter were allocated by analysing distribution of parameter values obtained from government databases. Distributed scores of source characteristics local environments: risk receptors were 12 : 12 : 12. The preliminary assessment scored 0 to 36 for each soil and groundwater sources. Inventory of soil and groundwater sources consisted of 7 categories. This study applied the preliminary assessment methodology to Manan-Gu, Anyang City, Korea. The number of car repair and washing facility was the largest in the contamination source inventory. Petroleum storage facilities showed the highest assessment score. The preliminary assessment methodology also indicated that Anyang-Dong was the priority section among Anyang-Dong, Suksu-Dong, Bakdal-Dong. This study is the first trial for relative ranking soil and groundwater contamination sources by considering source and local characteristics. Therefore, further researches and revision of the preliminary assessment methodology need to be pursued for various applications.

Zoning Method to Predict Contaminant Sources in Turbulent-Type Cleanroom (난류형 클린룸에서 영역분할법을 이용한 오염원 추정에 관한 연구)

  • Kim, D.K.;Sung, H.G.;Han, S.M.;Hwang, Y.K.
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.3
    • /
    • pp.253-260
    • /
    • 2015
  • Particle contamination in a cleanroom is very complex with a complicated process and several pieces of spreading equipment. Detailed information on the locations of the contamination sources and the path of the contamination is needed for economical and efficient control of the contaminant particles in such a cleanroom. An allocation method was developed to quantitatively predict the contamination generated from the pollution sources. In this paper, we propose a zoning method to accelerate the computation time for estimating the contributions. Our results showed that we can quantitatively estimate the amount of contamination generated from pollution sources.

Evaluation of Risk rates for Foreign Materials in a Minienvironment (클린룸 국소환경에서 이물의 위험율 평가)

  • Noh, Kwang-Chul;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.600-605
    • /
    • 2007
  • In this study, the risk rates of different contamination sources of the Foreign material in a minienvironment were analyzed through CFD simulation. From the results, the ambient contamination sources mainly affect wafers in the FOUP, whereas the internal contamination sources mainly affect wafers laid on the robot arm in the minienvironment. And the purging plenum system is very useful in protecting the wafers in the FOUP from Foreign materials transferred from the FFU. However, this system is unable to protect the wafers on the robot arm from internal Foreign materials and the wafers in the FOUP from sources of the interface between the FOUP and the minienvironment.

  • PDF

Mapping Soil Contamination using QGIS (QGIS를 이용한 토양오염지도 작성)

  • Kim, Ji-Young;Bae, Yong-Soo;Park, Jin-Ho;Son, Yeong-Geum;Oh, Jo-Kyo
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.5
    • /
    • pp.487-496
    • /
    • 2019
  • Objective: The purpose of this study was to create soil contamination maps using QGIS (Quantum Geographic Information System) and suggest selection methods for soil pollution sources for preferential investigation in a soil contamination survey. Method: Data from soil contamination surveys over five years in Gyeonggi-do Province, South Korea (2013-2017) were used for making soil contamination maps and analyzing the density of survey points. By analyzing points exceeding the concern level of soil contamination, soil pollutant sources for priority management were identified and selection methods for preferred survey points were suggested through a study of the model area. Results: A soil contamination survey was conducted at 1,478 points over five years, with the largest number of surveys conducted in industrial complex and factory areas. Soil contamination maps for copper, zinc, nickel, lead, arsenic, fluoride, and total petroleum hydrocarbons were made, and most of the survey points were found to be below concern level 1 for soil contamination. The density of the survey points is similar to that of densely populated areas and factory areas. The analysis results of points exceeding the criteria showed that soil pollutant sources for priority management were areas where ore and scrap metals were used and stored, traffic-related facilities areas, industrial complex and factory areas, and areas associated with waste and recycling. According to the study of the model area, the preferred survey points were traffic-related facilities with 15 years or more since their construction and factories with a score of 10 or more for soil contamination risk. Conclusion: Soil contamination surveys should use GIS for even regional distribution of survey points and for the effective selection of preferred survey points. This study may be used as guidelines to select points for a soil contamination survey.

Simulation of the Route of 4-Nitrophenol in the Geumho River and Analysis of the Impact of Potential Contamination Sources using a Numerical Model (수치모형을 이용한 금호강 수계 내 4-Nitrophenol의 거동 모의 및 잠재 오염원의 영향 분석)

  • Park, Kyeong-Deok;Shin, Dong-Seok;Yang, Duk-Seok;Lee, Injung;Lim, Young-Kyong;Kim, Il-Kyu
    • Journal of Environmental Science International
    • /
    • v.26 no.2
    • /
    • pp.211-220
    • /
    • 2017
  • For areas with the diverse contamination sources, the change of 4-nitrophenol contamination and impact of potential contamination sources have been evaluated using monitoring data and a numerical model (HydroGeoSphere). The model considered several parameters including land cover, precipitation, and flow rate. And, the model has been performed to investigate the effect of decay rate of 4-nitrophenol. The results of the simulations showed that the influence on 4-nitrophenol in downstream was mainly greater than that in upstream, and the tributaries did not significantly affect the mainstream because of their low flow rates. In addition, the effect of contamination sources was simulated for each section, then the measured data were higher than the corresponding simulated data in most sections of the Geumho river. In particular, the impact of the potential contamination sources in the upstream area was much higher than that in the other area, thus more monitoring data for the upstream area is required.

Groundwater Contamination (지하수 오염)

  • Jeon, Hyo-Taek
    • 수도
    • /
    • v.25 no.1 s.88
    • /
    • pp.25-35
    • /
    • 1998
  • Factors controlling water quality, water-quality standards, and normal ranges of concentrations in unpolluted fresh water and the sources of elements were explained in this paper. In particular, the sources of groundwater contamination such as the disposal of domestic waste water, landfills, chemical spills and leaking underground tanks, and agricultural and mining activities were discussed.

  • PDF