창원지역 지하수 수질과 DRASTIC에 의한 지하수 오염취약성 평가

  • 김무진;함세영;정재열;장성;차용훈
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.459-462
    • /
    • 2004
  • This study assesses groundwater vulnerability to contaminants in 12 administrative districts of the city of Changwon, using DRASTIC technique. DRASTIC was originally applied to situations in which the contamination sources are at the ground surface, and the contaminants flow into the groundwater with infiltration of rainfall. However, groundwater contamination in urban areas can also be related to excessive pumping resulting in a lowering of the water level. The correlation coefficient between minimum DRASTIC indices and the degree of poor water quality for 10 districts is low as 0.40. The correlation coefficients between minimum DRASTIC indices and the groundwater discharge rate, and between minimum DRASTIC indices and well density per unit area are 0.70 and 0.87, respectively. Thus, to evaluate the potential of groundwater contamination in urban areas, it is necessary to consider other factors such as groundwater withdrawal rate and well density per unit area with ratings and weights as well as the existing six DRASTIC factors.

  • PDF

Variation in Leakage Current Characteristics of Polymer Insulator for Various Environmental Condition (여러 환경조건에 대한 고분자애자의 누설전류 특성 변화)

  • Park Jae-Jun;Choi In-Hyuk;Lee Dong-il
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.2
    • /
    • pp.169-175
    • /
    • 2006
  • This study investigated variation leakage current maximum value and waveform considering applied voltage phase angel by simulating three environmental conditions, such as fog, salt fog, and kaolin contamination .As the result of applied voltage phase angel characteristics, leakage currents presented almost in phases in the early stage regardless of environmental conditions just after applying the voltage, and the phase of leakage currents certain phase lags for the discharge of the applied voltage when surface discharges occurred due to the continuous environmental contamination. In addition, the difference in phase significantly increased according to the intensity of discharges. The change in distortion rates according to the environmental contamination presented a nearly same level just after applying the voltage. The distortion rate of third harmonic for the fundamental wave presented by the order of fog>salt fog>kaolin when surface discharges occurred due to the applied voltage for certain continued periods. In the case of the fog and salt fog, the scale of spectrums decreased according to the increase in frequencies from the results of the analysis of high frequencies. In addition, the even number frequency presented a relatively large level compared to the odd number frequency under the kaolin contamination.

Measurement of Microbic Contamination Rate in the Dispensing Process Making Suspension of Barium Sulfate Powder (분말 형태의 황산바륨을 현탁액으로 조제하는 과정에서 발생하는 미생물의 오염도 측정)

  • Kim, Young-Keun;Lee, Yang-Sub;Cho, Cheong-Chan;Ryu, Meung-Sun;Lee, Kyung-Sup
    • Journal of radiological science and technology
    • /
    • v.24 no.2
    • /
    • pp.53-57
    • /
    • 2001
  • The purpose of this study is to investigate the contamination rate of barium sulfate suspension made in the exposed state in usual circumstances. This study was performed in four university hospital using the contrast media by barium sulfate powder. The specimen were detected at dispensing water, agitator and mixing tank. We also classified the suspension into general bacteria, mycete, and Bacillus coli infection. The tap water were used to dispense water in the all hospitals. Bacillus colt were not detected in the all. General bacteria and mycete were not detected in the one specimen, but detected in two specimen over defined value. In the contamination rate of agitator, mixing tank, and the manufactured, Bacillus coli were not detected in all. However, general bacteria and mycete were detected too numberous to count. In conclusion, the refined water must be used in dispensing water in manufacturing suspension. The disinfectant is also used in washing the agitator and mixing tank for sterilization. Hand washing is indispensible to manufacturing suspension for preventing from infection.

  • PDF

An Efficient Micropropagation to Obtain the Disease-free Bulbs from Scales for Cryopreservation in Lilium

  • Song, Jae-young;Yi, Jung-yoon;Yoon, Mun-sup;Lee, Jung-ro;Lee, Young-yi
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2019.10a
    • /
    • pp.37-37
    • /
    • 2019
  • Cryopreservation is one of the ideal and suitable methods for long-term storage of plant germplasm. The plant contaminated with diseases and pathogens are decreased the multiplication rate, survival rate and high quality of plants after cryopreservation. The aim of this work was to improve a micropropagation method for lily in Korea, which are cultivars and indigenous plant. In the last process of rinsing scales after surface-sterilization, we tried to control the diseases and pathogens lived within the tissue by rinsing in 0.03% sodium hypochlorite (NaClO) instead of sterile distilled water. Bulb scales of Lilium were cultured in vitro on MS medium supplemented with Plant Preservative Mixture (PPM). The newly small bulb formed from bulb-scales was transferred to MS medium. We checked the non-contamination and survival rate after 2 weeks in culture. Non-contamination was shown to be 70 to 90% in formed small bulbs. This study will help to mitigate microbial contamination in Lilium species micropropagation for cryopreservation.

  • PDF

Analysis of Microbial Contamination in Poultry Slaughtering Operations for the Application of HACCP (HACCP 적용을 위한 도계처리 공정내 미생물 오염의 분석)

  • 홍종해;권혁무;고주언
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.1
    • /
    • pp.45-50
    • /
    • 1996
  • The application of HACCP system, which was adopted by Codex Alimentarius Committee for the safe meat and poultry production, is one of the urgent task for competing in the world trade markets. But there have been no useful analytical studies to identify the causes of contamination in the poultry meat processing plants in Korea. This study was conducted to investigate the potential hazards during the operations by the microbiological examination for the poultry meat processing plant (20,000 birds capacity a day) located in Kangwon province. In spite of air contamination of work places, it may not directly affect the surface contamination of poultry meats. But the risk of Campylobacter jejuni/coli contamination was high. The number of total count was decreased about ten times, but remarkable changes of microbial contamination could not be recognized in each procedure during the operations. The washing water was already contaminated as much as $10^{3-6}CFU/ml$ in SPC before the operations. It means that to keep water tanks hygienic is a primary step to prevent the occurrences of microbial contamination. The overflow and recirculation of water in scalding, washing, and chilling was aslo an important factor for a hygienic control. Based on this study, the followings could be regarded as an important factors for hygenic control in the poultry slaughtering plants on a small scale. The temperature of water used for scalding should be constantly maintained on a required temperature, and the overflow rate of 1~1.5 liter per bird. The carcass surface and the body cavity should be washed thoroughly and the cross-contamination due to facilities, workers, and tools should be prevented. The chilling water sholud be maintained under 5$\circ$C of temperature with ice and overflow, and residual chlorine level of 50 ppm.

  • PDF

Microbial contamination in contact lens care systems (Contact lens care system의 미생물 오염)

  • Kim, Sang-Moon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.1
    • /
    • pp.57-63
    • /
    • 1996
  • The microbial contamination in contact lens care systems and conjunctivas of 40 asymptomatic cosmetic soft contact lens wearers was investigated. Patient ages ranged from 19 to 27(mean:22), most of them have used hydrogel contact lenses for less than 1 year, and the ages of lens cases were 1 weeks ~ 3 months (43 %) or 4~6 months (52%). Twenty-seven patients (67%) chemically disinfected their lenses and 8(20 %) used hydrogen peroxide, and 5 used heat to disinfect. Fourteen patients used commercial non-preserved saline, and 26(65%) were using commercial preserved saline. Sixty-two percent of the patients had bacterial contamination of lens case, and 17% had conjunctival contamination. The bacterial contamination rate was highest in lens cases, followed by unpreserved salines, disinfecting chemicals(non-hydrogen peroxide), and conjunctivas. The fungal contamination rate of cases and conjunctivas was 67% and 15%, respectively, and lens case, unpreserved saline, and conjunctiva seemed more susceptible to contamination. The use of hydrogen peroxide for disinfection rather than chemical disinfection was associated remarkabley with decreased contamination of solution itself, and there was no significant difference in contamination rates between hydrogen peroxide care system and other disinfecting systems. Five of lens cases(13%) and 2 conjunctivas(5%) were contaminated with Pseudomonas aeruginosa, and Candida albicans were isolated from 11cases (27%) and 5 conjunctivas (12%). Of the organisms that were contaminated lens cases and conjunctivas, Pseudomonas aeruginosa, Escherichia coli, Candida albicans, and Aspergillus fumigatus were isolated from lens cases, whereas Pseudomonas aeruginosa, Candida albicans, and Aspergillus fumigatus were recorvered from conjunctivas. Fortunately all of the these tested samples showed 0% of Acanthamoeba in this investigation.

  • PDF

A Study of the Device Development for the Contamination Detection in the Delivery Line (유체배관 오염 검출장치 개발에 관한 연구)

  • Jeong, Yi Ha;Kim, Byung Han;Hong, Joo-Pyo
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.1
    • /
    • pp.45-49
    • /
    • 2015
  • Process gases with vapor or liquid phase as well as gas phase may experience alteration in itself or be contaminated in the fluid pipe to the process chamber. And thus it result in as particles or defects on the substrates in semiconductor, LCD, LED manufacturing. Purifiers and filters are used for control of contamination. However, none of detection device is available in the delivery line. In this paper, we propose simple device with lighting and sensing in order to predict contamination of the fluid or the tube wall. For some general purpose gases, it showed constant voltage output regardless of the flow rates. But, the smoke and the moisture in the air lowered the figure due to its concentration. Numerical values for several solid and liquid media were obtained. And, the operating temperature tendency was investigated.

Microbial change of pork carcass during processing in small size slaughterhouse (소규모 돼지도축공정에서 도체오염 미생물의 변화)

  • 홍종해;이경환;이성모
    • Korean Journal of Veterinary Service
    • /
    • v.25 no.1
    • /
    • pp.31-37
    • /
    • 2002
  • Major hazards existed in slaughterhouse are pathogenic microorganisms originated from intestinal microflora of slaughtered animals. This study was intended for the identification of microbial contamination sources during pork slaughtering in small plants. Total aerobic bacteria, Coliform group, Salmonella spp, Listeria monocytogenes, and Campylobacter jejuni/coli were isolated from the surface sample of pork carcasses. Contamination level among different sampling points of ham, belly and neck did not showed statistical differences. Therefore, the mixed sampling from belly and neck of carcass could be effective for microbiological monitoring. Isolation rates of pathogenic microorganisms showed Salmonella spp 20.9%, Listeria monocytogenes 10.5%, and Campylobacter jejuni/coli 8.1% from 296 sampling points. High prevalence rate of Salmonella spp indicated that the contamination of intestinal microflora occurred due to unsanitary processing control, which required HACCP system in small plants. It was recommended that the prerequisite program should be a key factor for a successful HACCP system implementation especially in small size slaughterhouse.

Evaluation of Risk rates for Foreign Materials in a Minienvironment (클린룸 국소환경에서 이물의 위험율 평가)

  • Noh, Kwang-Chul;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.600-605
    • /
    • 2007
  • In this study, the risk rates of different contamination sources of the Foreign material in a minienvironment were analyzed through CFD simulation. From the results, the ambient contamination sources mainly affect wafers in the FOUP, whereas the internal contamination sources mainly affect wafers laid on the robot arm in the minienvironment. And the purging plenum system is very useful in protecting the wafers in the FOUP from Foreign materials transferred from the FFU. However, this system is unable to protect the wafers on the robot arm from internal Foreign materials and the wafers in the FOUP from sources of the interface between the FOUP and the minienvironment.

  • PDF

Transfer rates of pathogenic bacteria during pork processing

  • Park, Jung min;Koh, Jong Ho;Cho, Min Joo;Kim, Jin Man
    • Journal of Animal Science and Technology
    • /
    • v.62 no.6
    • /
    • pp.912-921
    • /
    • 2020
  • We examined the rates of pathogenic bacterial cross-contamination from gloves to meat and from meat to gloves during pork processing under meat-handling scenarios in transfer rate experiments of inoculated pathogens. The inoculated pork contained ~5-6 Log10 CFU/g pathogenic bacteria like Escherichia coli (E. coli), Staphylococcus aureus (S. aureus), Listeria monocytogenes (L. monocytogenes), and Salmonella enterica subsp. enterica (Sal. enteritidis). On cotton gloves, after cutting the pork, the cutting board, knife, and cotton gloves showed 3.07-3.50, 3.29-3.92 and 4.48-4.86 Log10 CFU/g bacteria. However, when using polyethylene gloves, fewer bacteria (3.12-3.75, 3.20-3.33, and 3.07-3.97 Log10 CFU/g, respectively) were transferred. When four pathogens (6 Log10 CFU/g) were inoculated onto the gloves, polyethylene gloves showed a lower transition rate (cutting board 2.47-3.40, knife 2.01-3.98, and polyethylene glove 2.40-2.98 Log10 CFU/g) than cotton gloves. For cotton gloves, these values were 3.46-3.96, 3.37-4.06, and 3.55-4.00 Log10 CFU/g, respectively. Use of cotton gloves, polyethylene gloves, knives and cutting boards for up to 10 hours in a meat butchering environment has not exceeded HACCP regulations. However, after 10 h of use, 3.09, 3.27, and 2.94 Log10 CFU/g of plate count bacteria were detected on the cotton gloves, cutting board, and knives but polyethylene gloves showed no bacterial count. Our results reveal the transfer efficiency of pathogenic bacteria and that gloved hands may act as a transfer route of pathogenic bacteria between meat and hands. The best hand hygiene was achieved when wearing polyethylene gloves. Thus, use of polyethylene rather than cotton gloves reduces cross-contamination during meat processing.