• Title/Summary/Keyword: contamination electron

Search Result 158, Processing Time 0.025 seconds

Monte Carlo Simulation for Electron Contamination of Photon Beam (치료용 광자선의 전자오염에 대한 몬테카를로 시뮬레이션)

  • Chung, Kap-Soo;Ko, Shin-Kwan;Yang, Han-Joon;Han, Chang-Yul
    • Journal of radiological science and technology
    • /
    • v.22 no.2
    • /
    • pp.47-51
    • /
    • 1999
  • We calculated the energy distribution and the percentage depth-dose at 10 cm in a $10{\times}10\;cm^2$ with a photon beam at SSD of 100 cm by using a Monte Carlo Simulation. PDD is used as a beam-quality specifier for radiotherapy beams. It is better than the commonly used values of TPR or nominal accelerating potential. The presence of electron contamination affects the measurement of PDD, but can be removed by the use of a 0.1 cm lead filter. It reduces surface dose from contaminant electrons from the accelerator by more than 90% for radiotherapy beams. The filter performs best when it is placed immediately below the head. An electron-contamination correction factor is introduced to correct for electron contamination from the filter and air. It converts PDD which includes the electron contamination with the filter in place into PDD for the photons in the filtered beam. The correction factor can be used to determine stopping-power ratio. Calculations show that the values of water-to-air slopping power ratio in the unfiltered beam are related to PDD.

  • PDF

Contamination of an Alcyon Co-60 Gamma rays by Electrons (Alcyon Co-60 감마선의 전자오염)

  • Yoo Meong-Jin;Kim Dong-Won;Kim Chul-Soo;Chung Woon-Hyuk
    • Radiation Oncology Journal
    • /
    • v.6 no.1
    • /
    • pp.109-116
    • /
    • 1988
  • The Alcyon Co-60 gamma rays was studied for electron contamination. The surface dose, attributable almost entirely to contamination electrons, has a linear dependence on field width for square fields and an inverse square dependence on distance from the bottom of the fixed head assembly Build-up and surface dose measurements were taken with and without an acrylic blocking tray in place. Further measurements were made with a copper filter designed to reduce secondary electrons emitted by photon interactions with the acrylic tray. The results are discussed in relation to skin sparing effect for radiation therapy Patients. And to achieve the maximum skin sparing effect, the selection of the optimum SSD and TSD is needed.

  • PDF

Study on the Reduction of Electron Contamination with A Cobalt-60 Gamma Ray (코발트-60 감마선의 전자 오염에 관한 연구)

  • Kim, Tae-Kyu;Chun, Ha-Chung;Lee, Myung-Za
    • Radiation Oncology Journal
    • /
    • v.7 no.2
    • /
    • pp.293-297
    • /
    • 1989
  • Electron contamination due to the interaction between radiation beam and material was analyzed for the factors such as source-skin distance (SSD), field size, tray characteristics and position of filter, which can affect the surface dose in Cobalt teletherapy. Surface dose in open beam was more influenced by SSD with increasing field size. Relative surface charge (RSC) increased with the use of tray (solid, circular hole, slotted), compared with open beam, which is thought to be due to increased electron contamination of the tray. To reduce the surface dose, 0.4mm thick Lipowitz metal filter was used. Compared with open beam, RSC decreased by 8.8%, 11.3%, 13.3%, 16.6%, 19.3% and 21.7% for the field size of $5{\times}5$, $10{\times}10$, $15{\times}15$, $20{\times}20$, $25{\times}25$ and $30{\times}30cm^2$, respectively. On the contrary, use of Lipowitz metal filter increased RSC at 60cm or less SSD. Surface dose was effectively reduced with Lpowitz metal filter placed right below solid tray in Cobalt teletherapy.

  • PDF

A Study on the Contamination of D.I. Water and its Effect on Semiconductor Device Manufacturing (초순수의 오염과 반도체 제조에 미치는 영향에 대한 연구)

  • Kim, Heung-Sik;Yoo, Hyung-Won;Youn Chul;Kim, Tae-Gak;Choi, Min-Sung
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.11
    • /
    • pp.99-104
    • /
    • 1993
  • We analyzed the D.I. water used in wet cleaning process of semiconductor device manufacturing both at the D.I. water plant and at the wafer cleaning bath to detect the impurity source of D.I. water contamination. This shows that the quantity of impurity is related to the resistivity of D.I. water, and we found that the cleanliness of the wafer surface processed in D.I. water bath was affected by the degree of the ionic impurity contamination. So we evaluated the cleaning effect as different method for Fe ion, having the best adsoptivity on wafer surface. Moreover the temperature effect of the D.I. water is investigated in case of anion in order to remove the chemical residue after wet process. In addition to the control of D.I. water resistivity, chemical analysis of impurity control in D.I. water should be included and a suitable cleaning an drinsing method needs to be investigated for a high yielding semiconductor device.

  • PDF

Effect of Electron Acceptors on the Anaerobic Biodegradation of BTEX and MTBE at Contaminated Sites (전자 수용체가 BTEX, MTBE로 오염된 토양의 혐기성 자연정화에 미치는 영향)

  • Kim, Won-Seok;Kim, Ji-Eun;Baek, Ji-Hye;Sang, Byoung-In
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.4
    • /
    • pp.403-409
    • /
    • 2005
  • Methyl tert-butyl ether (MTBE) contamination in groundwater often coexists with benzene, toluene, ethylbenzene, and xylene (BTEX) near the source of the plume. Then, groundwater contamination problems have been developed in areas where the chemical is used. Common sources of water contamination by BTEX and MTBE include leaking underground gasoline storage tanks and leaks and spills from above ground fuel storage tanks, etc. In oil-contaminated environments, anaerobic biodegradation of BTEX and MTBE depended on the concentration and distribution of terminal electron acceptor. In this study, effect of electron acceptor on the anaerobic biodegradation for BTEX and MTBE-contaminated soil was investigated. This study showed the anaerobic biodegradation of BTEX and MTBE in two different soils by using nitrate reduction, ferric iron reduction and sulfate reduction. The soil samples from the two fields were enriched for 65 days by providing BTEX and MTBE as a sole carbon source and nitrate, sulfate or iron as a terminal electron acceptor. This study clearly shows that degradation rate of BTEX and MTBE with electron acceptors is higher than that without electron acceptors. Degradation rate of Ethylbenzene and Xylene is higher than that of Benxene, Toluene, and MTBE. In case of Benzene, Ethylbenzene, and MTBE, nitrate has more activation. In case of Toluene and Xylene, sulfate has more activation.

Reduction of Electron Contamination Using a Filter for 6MV Photon Beam (6MV 광자선에서 전자오염 감소에 관한 연구)

  • Lee, Choul-Soo;Yoo, Myung-Jin;Yum, Ha-Yong
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.159-165
    • /
    • 1997
  • Purpose : Secondary electrons generated by interaction between Primary X-rar beam and block tray in megavoltage irradiation, result in excess soft radiation dose to the surface layer To reduce the surface dose from the electron contamination, electron filters were attached under the tray when a customized block was used. Materials and Methods : Cu, Al or Cu/Al combined Plate with different thickness was used as a filter and the surface dose reduction was measured for each case. The measurement to find optimal filter was performed with $10m\times10cm$ field size and 78.5cm source to surface distance. The measurement points are positioned with 2mm intervals from surface to maximum build-up point. To acquire the effect of field size dependence on optimal electron filter, the measurement was performed from $4cm\times4cm\;to\;25cm\times25cm$ field sizes. Results : The surface dose was slowly increased by increasing irradiation field but rapidly increased beyond $15cm\times15cm$ field size. Al plate was found to be inadequate filter because of the failure to have surface dose kept lowering than the dose of deep area. Cu 0.5mm plate and Cu/Al=0.28mm/1.5mm combined plate were found to be optimal filters. By using these 2 filters, the absorbed dose to the surface layer was effectively reduced by $5.5\%,\;11.3\%,\;and\;22.3\%$ for the field size $4cm\times4cm,\;10m\times10cm,\;and\;25cm\times25cm$, respectively. Conclusion : The surface dose attributable to electron contamination had a dependence on field size. The electron contamination was increased when tray was used. Specially the electron contamination in the surface layer was greater when the larger field was used. 0.5mm Cu Plate and Cu/Al=0.28mm/15mm combined plates were selected as optimal electron filters. When the optimal electron filter was attached under the tray, excessive surface dose was decreased effectively The effect of these electron filters was better when a larger field was used.

  • PDF

The Proton Contamination Problem of RBSPICE's electron data during March 1, 2013 storm event

  • Kim, Hang-Pyo;Hwang, Junga;Choi, Eunjin;Park, Jong-Seon;Park, Young-Deuk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.95.1-95.1
    • /
    • 2013
  • The RBSPICE (Radiation Belt Storm Probes Ion Composition Experiment) is one of five instrument suites onboard the twin Van Allan Probes (or Radiation Belt Storm Probes; RBSP), launched August 30, 2012 by NASA. One of science targets of RBSPICE instrument is to determine "how changes in that ring current affect the creation, acceleration, and loss of radiation belt particles?". For that purpose, it measures ions and electrons simultaneously. Ion's energy range is from ~20 keV to ~1 MeV and electron's energy channel is from ~35 keV to 1 MeV in order to provide supplementary information about the radiation belts. In this paper, we investigate a reliability of the electron flux measured from the RBSPICE by comparing with ECT (The Energetic Particle, Composition and Thermal Plasma Suite) data. We found there is a critical proton contamination problem in the electron channels of ~ 1MeV of RBSPICE observations during one moderate storm event of Sym H ~ -76 nT on March 1, 2013.

  • PDF

The Comparative Study On Scanning Electron Microscopic Findings Of Retrived ePTFE Membrane With Clinical Conditions (제거된 ePTFE 막의 주사전자현미경적 소견과 치주임상상태의 비교연구)

  • Park, Jeong-Min;Choi, Byung-Son;Lee, Seok-Cho;Kim, Hyung-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.133-142
    • /
    • 1996
  • Ten intrabony defects in 10 patients were treated by flap surgery including root surface debridement and placement of an expanded polytetrafluoroethylene(ePTFE) membrane. The membranes were removed after 4-6 weeks. This study was performed to examine the retrived ePTFE membrane by scanning electron microscopy(SEM) for bacterial contamination and adherent connective tissue elements, and to compare it with clinical conditions. The cervical portion of the membrane, which in most cases had become partially exposed to the oral cavity, had a bacterial deposit. Small bacterial colonies and a scatter of single cells in some instances extended into the apical portion of the membrane. Fibroblast-like cells, erythrocytes and fibrous structures were seen in the apical portion of the membrane. Outer surface of membrane tends to more bacterial contamination than inner surface(p<0.01), and upper portions more than lower portions(P<0.01). Comparison of ultrastructural findings and clinical conditions revealed that extent of bacterial contamination of the membrane correlated with gingival inflammation and extent of membrane exposure, but it was not significant statistically. The results suggested that gingival inflammation and membrane exposure affect periodontal regeneration by the use of ePTFE membrane.

  • PDF

DC Langmuir Probe for Measurement of Space Plasma: A Brief Review

  • Oyama, Koichiro
    • Journal of Astronomy and Space Sciences
    • /
    • v.32 no.3
    • /
    • pp.167-180
    • /
    • 2015
  • Herein, we discuss the in situ measurement of the electron temperature in the ionosphere/plasmasphere by means of DC Langmuir probes. Major instruments which have been reported are a conventional DC Langmuir probe, whose probe voltage is swept; a pulsed probe, which uses pulsed bias voltage; a rectification probe, which uses sinusoidal signal; and a resonance cone probe, which uses radio wave propagation. The content reviews past observations made with the instruments above. We also discuss technical factors that should be taken into account for reliable measurement, such as problems related to the contamination of electrodes and the satellite surface. Finally, we discuss research topics to be studied in the near future.

Practical Issues on In Situ Heating Experiments in Transmission Electron Microscope (투과전자현미경 내 직접 가열 실험에서의 실험적 문제들)

  • Kim, Young-Min;Kim, Jin-Gyu;Kim, Yang-Soo;Oh, Sang Ho;Kim, Youn-Joong
    • Applied Microscopy
    • /
    • v.38 no.4
    • /
    • pp.383-386
    • /
    • 2008
  • In performing in situ heating transmission electron microscopy (TEM) for materials characterizations, arising concerns such as specimen drifts and unintentional Cu contamination are discussed. In particular, we analysed the thermal and mechanical characteristics of in situ heating holders to estimate thermal drift phenomena. From the experimental results, we suggest an empirical model to describe the thermal drift behavior so that we can design an effective plan for in situ heating experiment. Practical approaches to minimize several hindrances arisen from the experiment are proposed. We believe that our experimental recommendations will be useful for a microscopist fascinated with the powerful potential of in situ heating TEM.