• Title/Summary/Keyword: contamination degree

Search Result 338, Processing Time 0.027 seconds

Degree of contamination in 3-way stopcock connected to infusion set on the intravenous therapy (정맥내 주사요법시 수액세트에 연결된 3 way-stopcock의 오염정도에 관한 실태조사)

  • Hong, Hae-Sook;Kim, Yun-Kyung;Na, Yeon-Kyung;Lee, Gyeung-Ran;Kwak, Kyung-Suk
    • Journal of Korean Biological Nursing Science
    • /
    • v.4 no.2
    • /
    • pp.113-125
    • /
    • 2002
  • This study is to evaluate contamination of the 3-way stopcocks connected to infusion set, which is used to the patients admitted to emergency room in a general hospital in D city. The data were collected from Oct. 1, 2001 to Feb. 25, 2002. First of all, in order to select microorganisms, From the 50 patients were randomized, Coagulase Negative Staphylococcus, Staphylococcus aureus, micrococcus, Pseudomonas aeruginosa, Acinetobacter detected. Coagulase Negative Staphylococcus, Staphylococcus aureus, micrococcus were determined to be evaluated in this study. As a result, 8 of the patients were Coagulase Negative Staphylococcus positive(>15 colonies), 4 were Staphylococcus aureus positive(>15 colonies). 1 was micrococcus positive(>15 colonies). Among the patients who were Coagulase Negative Staphylococcus positive 112(average) colonies were detected on the first day, 429 were on the second day, and 563 were on the third day. In case of patients of Staphylococcus aureus positive, 85(average) colonies were detected on the first day, 151 were on the second day, and the 203 were on the third day. CNS was cultured using API kit for the 8 patients who were in CNS positive. One case was detected Staphylococcus capitis, another one case was Staphylococcus chromogenes. Two cases were Staphylococcus xylosus, another two were Staphylococcus hominis, and the remainer were Staphylococcus epidermidis. As a result, the API codes of two Staphylococcus epidermidis had shown the same pattern, and the resistance patterns of the them were the same, too. As a result of resistance test among 5 patients who have shown that the same resistance pattern in 02SAK1, 02SAK5, 02SAK2, 02SAK4. As a result of this study, aseptic technique of 3-way stopcock intravenous therapy can protect infections, and it is needed the sterilization of the 3-way stopcock just before injection using disinfectants. It needs to improve the 3 way stopcock change intervals from 48 hours.

  • PDF

Monitoring of Microbial Contaminants in Processing Line of Some Mushromm Canneries (양송이 통조림 공장의 미생물 오염도 변화 추적)

  • 신동화;홍재식
    • Journal of Food Hygiene and Safety
    • /
    • v.4 no.2
    • /
    • pp.103-108
    • /
    • 1989
  • Three mushroom cannerries were selected by size which are representative vegetable processing firms in korea for monitoring microbial contamination of processing water, washing water, mushroom before and after washing through first and second washing tanks and, blanched and prolonged mushroom for certain time at room temperature. Total contamination degree was expressed as colony forming unit (CFU) of mesophilic aerobes. The contamination degree of processing water was $10^{2}\;CFU/100\;ml$ and washing water in first and second washing tank were 10 to 100 times higher than processing water. When 2.3 tons of washing water was used for washing 1 ton of mushroom, washing effect was showed by reduction of microbial load but cutting it to 1.8 tonsIl ton of mushroom, microbial load was higher than that of raw mushroom level. Blanching reduced microbial load to 50-500 CFU/g of blanched mushroom and it was not seen much increase of CFU in blanched mushroom left at room temperature for 3 hours in $16^{\circ}C$ processing water. Just after injection of $80^{\circ}C$ brine in container, CFU/ml of brine in container was $84{\times}10^{4}$ but it was increased rapidly to $20{\times}10^{7}$ after 2 hours at ambient temperature.

  • PDF

Survey for contamination and study for reduction of ochratoxin A and aflatoxin in red pepper (고추 중 오크라톡신 A와 아플라톡신의 오염도 조사 및 저감화방안 연구)

  • Kim, Dong-Ho;Jang, Han-Sub;Kim, Yeong-Min;Ahn, Jong-Sung
    • Journal of Food Hygiene and Safety
    • /
    • v.24 no.4
    • /
    • pp.299-306
    • /
    • 2009
  • Aflatoxin (AF) and Ochratoxin A (OTA) are carcinogenic and possible carcinogenic mycotoxins respectively produced by Aspergillus spp or Penicillium spp. The study for contamination survey and proposal for reduction of mycotoxin in red pepper were carried out. 192 samples were collected at such various stages and markets as pre/post-harvest stages, internet shopping mall /super-market and small stakeholder mill/geographically indicated company. As only 2 samples were positive for aflatoxin, so contamination rate was 1.04%. In the meanwhile, contamination rate for ochratoxin A was 21.88% and a various amount of OTA was detected in 42 positive samples. 6 samples were found to be contaminated at higher level than $5\;{\mu}gkg^{-1}$ for ochratoxin A, which was established recently as a maximum permissible limit in korea. There was no difference in degree of contamination with regard to cultivation type because any mycotoxin was not found at all in both organically and conventionally grown red pepper. But, there was statistically significant difference in the process of manufacturing. Finished products were OTA-contaminated at a level of $2.32\;{\pm}\;6.54\;{\mu}gkg^{-1}$(mean ${\pm}$ SD), even though OTA was not detected in deep frozen red peppers right after long term storage. And contamination for OTA was a level of $0.33\;{\pm}\;0.91\;{\mu}gkg^{-1}$(mean ${\pm}$ SD) in red paprika powder after uv sterilization, while the contamination for OTA was $2.78\;{\pm}\;4.49\;{\mu}kg^{-1}$(mean ${\pm}$ SD) in non-uv sterilized powder. In addition, our investigation shows that higher OTA contamination occurred in some of famous brand products sold in super-market and domestic products than products collected through on-line shopping or from small stakeholder mills and imported products respectively, however, difference was not statistically significant.

Cost-effective Investigation on Contaminated Land and Assessment of Measurement Uncertainty (오염토양의 효율적 조사기법과 측정불확도의 평가방법)

  • 이종천
    • Economic and Environmental Geology
    • /
    • v.37 no.1
    • /
    • pp.49-59
    • /
    • 2004
  • The concectration and distribution of contaminants obtained from a contaminated land investigation or an environmental geochemistry survey constitutes the basis of a decision-making process on environmental policies or of scientific researches. As the quality of data determines the reliability of the result, the investigation plan should be adjusted according to the purpose of the investigation. In general, the effort to improve the data quality had been focused mainly on the QA/QC procedures in laboratories. The rapid progress of analytical instrument has also contributed toward improving the analytical precision to a sacrificable degree. Nevertheless, in many cases, it is not the analytical precision that needs improvement for the better precision of overall measurement process: it is rather during the sampling process in the field that is responsible for the poor precision. To assess the data quality on a measured value, ISO recommends to provide information on "measurement uncertainty" along with the measured value. The measurement uncertainty in an environmental measurement context can be explained as the statistical number that expresses the degree of the uncertainty stemming from the sampling and analytical procedures. There is a cost involved in order to improve the precision of sampling and analytical methods so as to decrease the degree of measurement uncertainty. The economical point of compromise in an investigation planning can be achieved when the allowable degree of uncertainty has been set before-hand. The investigation can then be planned accordingly not to exceed the uncertainty limit. Furthermore, if the measurement uncertainty estimated from the preliminary investigation can be separated into sampling and analytical uncertainties, it can be used as a criterion where the resources for the investigation should be allotted cost-effectively to reinforce the weakest link of the whole investigation process. This paper aims to present a method of estimating the level of measurement uncertainty of a measured contamination concentration at a site used as an example and to show how the estimated uncertainty can be applied to serve the particular purpose of an investigation.

Effect on Corrosion Characteristics of SS 400 Steel by Alkali Water pH from Electrolysis of City Water (수돗물의 전기분해에 의해서 생성된 알카리수의 pH가 SS 400강의 부식특성에 미치는 영향)

  • Moon, Kyung-Man;Ryoo, Hae-Jeon;Kim, Yun-Hae;Jeong, Jae-Hyun;Baek, Tae-Sil
    • Journal of Ocean Engineering and Technology
    • /
    • v.31 no.3
    • /
    • pp.248-255
    • /
    • 2017
  • Many rivers and seas have been affected by environmental contamination. Therefore, city water supplies often require a high-degree purification treatment to provide safe drinking water. However, in order to achieve a high-degree purification treatment, a large amount of chlorine has to be added to sterilize city drinking water. The added chlorine reacts chemically with water and forms hypochlorous and chlorine ions. The hypochlorous ionizes with hypochlorous ions and hydrogen ions. As a result, the city water contains a large amount of chlorine ion. As such, when city water is used with domestic boilers, many kinds of heat exchangers, and the engines of vehicle and ships, there are often corrosion problems. In this study, alkali water was electrochemically made by electrolysis of city water, and corrosion properties between alkali and city water were investigated with an electrochemical method. Most of the chlorine ions are thought to not be contained in the alkali water because the alkali water is created in the cathodic chamber with an electrolysis process. In other words, the chlorine ion can be mostly removed by its migration from a cathodic chamber to an anodic chamber. Moreover, the alkali water also contains a large amount of hydroxide ion. The alkali water indicated relatively good corrosion resistance compared to the city water and the city water exhibited a local corrosion pattern due to the chlorine ion created by a high-degree purification treatment. In contrast, the alkali water showed a general corrosion pattern. Consequently, alkali water can be used with cooling water to inhibit local corrosion by chlorine ions in domestic boilers, various heat exchangers and the engine of ships and for structural steel in a marine structure.

A Study on the ICCP Control and Monitoring System for Ship (선박용 ICCP 제어 감시 시스템에 관한 연구)

  • 이지영;오진석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.4
    • /
    • pp.667-674
    • /
    • 2004
  • This thesis is about the Impressed Current Cathodic Protection (ICCP) control and monitoring system. which brings protection against the corrosion of the ship's hull in the sea environments. The ICCP system is composed of a power supply. anode. reference electrode and controller. AC sources from the ship's generator are converted to DC sources in terms of power supply, and a protection current is sent to ship's hull though anode. The controller fully senses whether or not the detected potential is within a range of protection of ship's hull and then it is automatically controlled to increase or decrease the amount of protective current to be sent to the anode. The monitoring system with RS 232/485 communication is also studied in order to check the normal state of the system at a long period. because an operator does not always watch over this system and thus the system cannot operate well because of his or her negligent management. Since the vessel always navigates in the sea. an characteristics experiment of the ICCP system is conducted by introducing various corrosive environmental factors such as velocity, resistivity, dissolved oxygen, PH, temperature and contamination degree. These results must be referred to when the ICCP system is set up. In short. the ICCP is a multi-system for use on ships and on land structures because it includes a safety device. It is suggested that this system can accomodate a ship's automation and will be very useful.

Regression Analysis Between Climate Conditions and Contaminants for Development of Prediction Method of the Salt Pollution (염해 오손도 예측기법 개발을 위한 오손물과 기후 인자와의 상관관계 분석)

  • Kim, D.Y.;Kim, J.H.;Lee, W.Y.;Han, S.O.;Park, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.173-175
    • /
    • 2004
  • The degree of contamination on outdoor insulators is one of the most importance factor to determine the pollution level of outdoor insulation. Outdoor insulators in coastal are affected due to salty wind blowing from the seaside. The sea salt is known as the most dangerous pollutant. As known through the preceding study, the generation of salt pollutant and the pollution degree of outdoor insulators have a close relation in accordance with meteorological conditions, such as temperature, humidity, dewpoint, wind velocity and wind direction. Therefore, at first, we have analyzed relation between meteorological conditions and contaminants for development of prediction method. In this paper, we have investigated a statistical estimation technique based on actual data for equivalent salt deposit density(ESDD) of outdoor insulators which were installed in Kochang field test substation with multiple linear regression analysis.

  • PDF

Mitigation of steel corrosion in concrete by electrochemical chloride extraction at the AI-supporting electric source

  • Jiseok Kim;Ki Yong Ann;Woongik Hwang
    • Computers and Concrete
    • /
    • v.33 no.6
    • /
    • pp.631-642
    • /
    • 2024
  • The present study concerns the corrosion mitigation of electrochemical chloride extraction (ECE) in concrete structure. Concrete specimen was fabricated with 5.0% chloride in cast, while the other specimen was exposed to 4.0M NaCl solution for 1 year to accelerate corrosion of steel. Then, the ECE was applied to the concrete specimen with 1000 mA/m2 of the current density for 2, 4 and 8 weeks, respectively. During the ECE, the corrosion current density and corrosion potential were regularly monitored. As a result, the ECE was very effective in mitigating the degree of corrosion on the steel surface. The corrosion current density was significantly reduced from thousands to decades mA/m2, while the corrosion potential was mostly shifted to positive direction. Assuming that the corrosion starts at 1.0 mA/m2 of the corrosion current density or/and -275 mV vs SCE of the corrosion potential, the ECE could not fully achieve the repassivation of the steel, although its degree was lowered more or less depending on the duration of the treatment and type of chloride contamination. A visual examination confirmed that an increase in the duration of the treatment could lower the rust formation, but never fully removed all rust stains.

Assessing Groundwater Vulnerability Using DRASTIC Method and Groundwater Quality in Changwon City (DRASTIC과 지하수 수질에 의한 창원시 지하수 오염취약성 평가)

  • Hamm Se-Yeong;Cheong Jae-Yeol;Kim Moo-Jin;Kim In-Soo;Hwang Han-Seok
    • Economic and Environmental Geology
    • /
    • v.37 no.6 s.169
    • /
    • pp.631-645
    • /
    • 2004
  • This study assesses groundwater vulnerability to contaminants in industrial and residential/commercial areas of the city of Changwon, using DRASTIC technique and groundwater data. The DRASTIC technique was originally applied to situations in which the contamination sources are at the ground surface, and the contaminants flow into the groundwater with infiltration of rainfall. Mostly the industrial area has higher DRASTIC indices than the residential/commercial area. However, a part of the residential/commercial area having much groundwater production and great drawdown is more contaminated in groundwater than other industrial and the residential/commercial areas even if it has lowest DRASTIC indices in the study area. It indicates that groundwater contamination in urban areas can be closely related to excessive pumping resulting in a lowering of the water level. The correlation coefficient between minimum DRASTIC indices and the degree of poor water quality for 10 districts is as low as 0.40. On the other hand, the correlation coefficients between minimum DRASTIC indices and the groundwater discharge rate, and between minimum DRASTIC indices and well distribution density per unit area are 0.70 and 0.87, respectively. Thus, to evaluate the potential of groundwater contamination in urban areas, it is necessary to consider other human-made factors such as groundwater withdrawal rate and well distribution density per unit area as well as the existing seven DRASTIC factors.

Analysis of Pathogenic Microorganism's Contamination on Cultivation Environment of Strawberry and Tomato in Korea

  • Oh, Soh-Young;Nam, Ki-Woong;Kim, Won-Il;Lee, Mun Haeng;Yoon, Deok-Hoon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.47 no.6
    • /
    • pp.510-517
    • /
    • 2014
  • The purpose of this study was to analyze microbial hazards for cultivation environments and personal hygiene of strawberry and tomato farms at the growth and harvesting stage. Samples were collected from thirty strawberry farms and forty tomato farms located in Korea and tested for Staphylococcus aureus and Bacillus cereus. To investigate the change in the distribution of the S. aureus and B. cereus, a total of 4,284 samples including air born, soil or medium, mulching film, harvest basket, groves and irrigation water etc. were collected from eight strawberry farms and nine tomato farms for one year. As a result, total S. aureus and B. cereus in all samples were detected. Among the total bacteria of strawberry farms, S. aureus (glove: $0{\sim}2.1Log\;CFU/100cm^2$, harvest basket: $0{\sim}3.0Log\;CFU/100cm^2$, soil or culture media: 0~4.1 Log CFU/g, mulching film: $0{\sim}3.8Log\;CFU/100cm^2$), B. cereus (glove: $0{\sim}2.8Log\;CFU/100cm^2$, harvest basket: $0{\sim}4.8Log\;CFU/100cm^2$, soil or culture media: 0~5.3 Log CFU/g, mulching film: $0{\sim}4.5Log\;CFU/100cm^2$) were detected in all samples. The total bacteria of tomato farms, S. aureus (glove: $0{\sim}4.0Log\;CFU/100cm^2$, harvest basket: $0{\sim}5.0Log\;CFU/100cm^2$, soil or culture media: 0~6.1 Log CFU/g, mulching film: $0{\sim}4.0Log\;CFU/100cm^2$), B. cereus (glove: $0{\sim}4.0Log\;CFU/100cm^2$, harvest basket: $0{\sim}4.3Log\;CFU/100cm^2$, soil or culture media: 0~5.9 Log CFU/g, mulching film: $0{\sim}4.7Log\;CFU/100cm^2$) were detected in all samples. The contamination of S. aureus and B. cereus were detected in soil, mulching film and harvest basket from planting until harvest to processing, with the highest count recorded from the soil. But S. aureus and B. cereus were not detected in irrigation water samples. The incidence of S. aureus and B. cereus in hydroponics culture farm were less than those in soil culture. The amount of S. aureus and B. cereus detected in strawberry and tomato farms were less than the minimum amount required to produce a toxin that induces food poisoning. In this way, the degree of contamination of food poisoning bacteria was lower in the production environment of the Korea strawberry and tomato, but problems can be caused by post-harvest management method. These results will be used as fundamental data to create a manual for sanitary agricultural environment management, and post-harvest management should be performed to reduce the contamination of hazardous microorganisms.