• Title/Summary/Keyword: contamination

Search Result 5,461, Processing Time 0.033 seconds

A Survey on Microbial Contamination of Currently-Sold Drugs (I) -Bacterial contamination of marketed liquid- (시장의약품(市販醫藥品)의 미생물(微生物) 오염도(汚染度) 조사(調査) (제1보)(第1報) -시판내복액제(市販內服液劑)의 세균오염도(細菌汚染度)-)

  • Park, Young-Ju;Kim, Young-Il
    • Journal of Pharmaceutical Investigation
    • /
    • v.3 no.4
    • /
    • pp.5-15
    • /
    • 1973
  • An investigation was carried out on a basis of the bacteriological examination with a view to detecting the degree of bacterial contamination for the 77 samples collected from the locally-sold liquid specialties. It's test period was 50 days from July 10 to August 30, 1971. Specially, the survey has put emphasis on the population of general bacteria and the identification of coli-form group, staphylococcus species, streptococcus species, bacillus species, fungi, and yeast species from liquid samples. The results obtained are summarized as follows; (1) For the 77 samples tested, the contamination of general bacteria was found out as minimun 0, i,e., maximum, $12{\times}10^4$ and the total average $45{\times}10^2$ per milliliter. (2) Although streptococcus species could not be detected with the samples, the contamination of the coli-form and staphylococcus species means the strong suggestion of the possibility of pathogenic bacterial contamination. (3) Specially, the products which stay in the neutral pH range and use suspending agents need to care for the microbial contamination in the manufacturing crocess. (4) It is thought necessary to perform the microbiological quality control in the liquid preparations only at least. (5) As the microbial contamination degree in the liquid decreases according to the elapse of time, the microbiological quality control will have to be carried out immediately after the completion of the manufacturing process in order to know the accurate degree. (6) The author thinks that the main reason of the microbial contamination in the liquid is the contamination during the manufacturing process. (7) For the purpose of prevention of the microbial contamination in liquid, therefore, it is more important to make efforts for the rationalization of manufacturing process, the improvement of equipment and environment, the specific training of workers for hygienic knowledges, etc. rather than the use of preservatives for the preparations.

  • PDF

Priority Assessment for Groundwater Contamination Management Using Analytic Hierarchy Process (AHP) and GIS Approach (계층분석법(AHP)과 GIS를 이용한 고양시 일대의 지하수오염 관리우선순위 평가)

  • Lee, Moung-Jin;Hyun, Yunjung;Kim, Youngju;Hwang, Sang-Il
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.5
    • /
    • pp.26-38
    • /
    • 2013
  • In this study, priority for groundwater contamination management was assessed based on regional vulnerability in Goyang-si area, Gyonggi-do, Korea using analytic hierarchy process (AHP) and geographic information system (GIS). We proposed a concept for regional vulnerability to groundwater contamination with using socio-environmental vulnerability factors, which can be classified into three properties including regional hydrogeological property, contamination property, and groundwater use property. This concept is applied to Goyang-si area. For AHP analysis, an expertise-targeted survey was conducted. Based on the survey, a total of 10 factors (criteria) and corresponding weights for regional vulnerability assessment were determined. The result shows that regional contamination property is the most weighted factor among the three property groups (hydrogeological property: contamination property: groundwater use property = 0.3: 0.4: 0.3). Then, database layers for those factors were constructed, and regional vulnerability to groundwater contamination was assessed by weighted superposition using GIS. Results show that estimated regional vulnerability score is ranged from 22.7 to 94.5. Central and western areas of Goyang-si which have groundwater tables at shallow depths and are mainly occupied by industrial and residential areas are estimated to be relatively highly vulnerable to groundwater contamination. Based on assessed regional vulnerability, we classified areas into 4 categories. Category 1 areas, which are ranked at the top 25% of vulnerability score, take about 2.8% area in Goyang-si and give a high priority for groundwater contamination management. The results can provide useful information when the groundwater management authority decide which areas should be inspected with a high priority for efficient contamination management.

Studies on the HACCP Model of Steak-Set Menu in Hotel (HACCP 모델 적용시 호텔 .레스토랑의 세트 메뉴 중 스테이크에 관한 연구)

  • 양신철
    • Journal of Applied Tourism Food and Beverage Management and Research
    • /
    • v.12 no.1
    • /
    • pp.5-24
    • /
    • 2001
  • This study was focused on the sanitary analysis of hazard factors and the establishment of critical control points on steak-set menu In hotel by the documents and microbiological investigation. The hazard factors of shrimp cocktail were microbial contamination, residual pesticides, unsuitable healing and cross contamination. The hazard factors of potato soap were residual pesticides, microorganisms contamination, unsuitable heating and solanine in potato. The hazard factors of simple salad were microorganisms contamination, unsuitable heating and cross contamination by inappropriate package. The hazard factors of steal were residual antimicrobial drugs, microorganisms contamination, unsuitable heating and cross contamination. The critical control points of shrimp cocktail were temperature control , number of washing and center temperature control of heating step. The critical control points of potato soup were stock temperature control , number of washing and center temperature control of Heating step. The critical control points of simple salad were number of washing and dryness of utensil. The critical control points of steak were stock temperature control , number of washing, center temperature and time control of heating step.

  • PDF

Numerical analysis on the flow field and moisture contamination in a dry room (Dry Room내 기류 및 수분오염에 관한 수치적 연구)

  • Lee, Kwan-Soo;Lim, Kwang-Ok;Jung, Young-Sick
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.865-870
    • /
    • 2000
  • The flow and the moisture contamination of the dry room in the manufacturing process of lithium ion battery are analyzed numerically by finite volume method. Standard ${\kappa}-{\varepsilon}$ turbulent model widely applied in predicting turbulent flow is adopted in this study. Moisture contamination and distribution are studied by assumption of two cases; one-point generation and uniform generation throughout the room. To evaluate ventilation efficiency on moisture contamination, scales of ventilation efficiency are introduced. From these analyses, moisture contamination is strongly dependent on the flow field and the radius of moisture contamination can be reduced by closing a part of outlets in a dry room.

  • PDF

Automatic Measurement of the Degree of Contamination with Electric Conductivity and Oscillating Frequency (발진주파수 및 전도도를 통한 오손도 자동측정)

  • 최남호;구경완;이명섭;한상옥;정재기
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.153-156
    • /
    • 2000
  • To reduce the maintenance expense, and the possibility of electric outage and accident, we should optimize the outdoor insulation system. And for the optimization, accurate measurement for the degree of contamination with climatic conditions, such as wind, rain, and drought, should be carried. However the classical measuring method, brush wiping, has some problems in the aspect of man power, reliability, and expense. In this paper, we propose two type apparatus, which could detect the degree of contamination on insulators in outdoor insulation system, such as transmission and distribution line insulator and bushing. One use the leakage current, and the other use the oscillating frequency to check the degree of contamination. To avoid the oxidation of electrode AC source, and the low degree of contamination was applied. From the result of this investigation we could get the good relationship between the degree of contamination and the leakage current and oscillating frequency

  • PDF

A STUDY ON THE PREDICTION OF GROUNDWATER CONTAMINATION USING GIS (지하수오염 예측을 위한 GIS 활용연구)

  • Jo, SiBeom;Shon, HoWoong
    • Journal of the Korean Geophysical Society
    • /
    • v.7 no.2
    • /
    • pp.121-134
    • /
    • 2004
  • This study has tried to develop the modified DRASTIC Model by supplying the parameters, such as structural lineament density and land-use, into conventional DRASTIC model, and to predict the potential of groundwater contamination using GIS in Hwanam 2 District, Gyeonggi Province, Korea. Since the aquifers in Korea is generally through the joints of rock-mass in hydrogeological environment, lineament density affects to the behavior of groundwater and contaminated plumes directly, and land-use reflect the effect of point or non-point source of contamination indirectly. For the statistical analysis, lattice-layers of each parameter were generated, and then level of confidence was assessed by analyzing each correlation coefficient. Groundwater contamination potential map was achieved as a final result by comparing modified DRASTIC potential and the amount of pollutant load logically. The result suggest the predictability of contamination potential in a specified area in the respects of hydrogeological aspect and water quality.

  • PDF

A Study on Contamination Sensitivity and Condition Monitoring for a Pump (펌프의 오염 민감도와 성능 감시에 대한 연구)

  • 이재천
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.124-130
    • /
    • 1998
  • A mathematical model describing gear pump flow degradation in the presense of abrasive particles is presented. The model considers the operating parameters as Sommerfeld number, so that contamination sensitivity test results could be conversed to field application to predict contamination service life. A method to estimate the volumetric efficiency and the contamination level of a pump is proposed by measuring the temperature differences in the fluid. Test results show the validity of the theoretical establishments.

  • PDF

Evaluation of Salmonella cross contamination at retail chicken meat outlets in Kandy, Sri Lanka

  • Alwis, Upeksha S.;Mudannayake, Deshani C.;Jayasena, Dinesh D.;Ubeyarathna, Kamalika J.H.
    • Korean Journal of Agricultural Science
    • /
    • v.41 no.1
    • /
    • pp.35-40
    • /
    • 2014
  • This study was carried out to evaluate the Salmonella cross contamination at retail chicken meat outlets in Kandy, Sri Lanka and to identify the risk factors for Salmonella contamination at retail chicken meat outlets. Fifteen retail chicken meat outlets in Kandy area were randomly selected. Pre-tested questionnaires were used to collect data for identifying risk factors of Salmonella cross contamination at retail outlets and swab samples from meat contact surfaces/utensils were obtained. Out of 57 swab samples collected from meat contact surfaces/utensils, the overall prevalence of Salmonella cross contamination was 21%. Weighing scale (33%), meat containing trays/buckets (27%) and cutting board (25%) showed the highest percentage of Salmonella prevalence whereas knife and showcase showed relatively low percentages, 14% and 9%, respectively. Retail chicken outlets with slaughtering facilities had a significantly higher prevalence of Salmonella cross contamination than those without slaughtering facilities. This higher rate of Salmonella cross contamination at retail chicken meat outlets could be attributed to lack of proper cold chains and minimal facilities, and poor level of hygiene in those outlets.

An Experimental Investigation on the Contamination Sensitivity of an Automotive Fuel Pump

  • Lee Jae-Cheon;Shin Hyun-Myng
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.6 no.3
    • /
    • pp.51-55
    • /
    • 2005
  • This study addresses the contamination sensitivity test of a typical fuel pump for an automotive vehicle. The objective of the study is to find the contamination sensitivity coefficient of a fuel pump on specific contaminant particle sizes so that an optimal fuel filter could be selected. To achieve the objective, the degradation of discharge flow rate of the fuel pump is measured under the experiments of various contaminants size ranges of ISO test dust up to $80\;{\mu}m$. The fundamental theory of contamination sensitivity is introduced and the contamination sensitivity coefficients are estimated using the experimental data. Maximum contamination sensitivity coefficient of $5\chi\;10^{-6}\;L/min{\cdot}Ea$ is found in the contaminant size range of $40\;{\mu}m\~50\;{\mu}m$. The magnified picture of the surface of vane disc reveals that the abrasive wear is the principal cause of discharge flow rate degradation. Hence, this study reveals that a high efficiency filter for contaminant particles especially in the size range of $30\;{\mu}m\~70\;{\mu}m$ especially should be used to maintain the service life of the fuel filter.

An Experimental Investigation on The Contamination Sensitivity of An Automotive Fuel Pump (자동차 연료펌프의 오염민감도 실험 연구)

  • 이재천;장지현;신현명
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.6
    • /
    • pp.102-108
    • /
    • 2004
  • This study addresses the contamination sensitivity test of a typical fuel pump for automotive vehicle. The objective of the study is to find the contamination sensitivity coefficient of fuel pump on specific contaminant particle sizes so that optimal fuel filter could be selected. To achieve the objective, the degradation of discharge flow rate of fuel pump was measured under the experiments of various contaminants size ranges of ISO test dust up to 80${\mu}{\textrm}{m}$. The fundamental theory of contamination sensitivity was introduced and the contamination sensitivity coefficients were estimated using the experimental data. Maximum contamination sensitivity coefficient of $5{\times}10^{-6}$ L/minㆍEa was found on the contaminant size range of 40${\mu}{\textrm}{m}$∼50${\mu}{\textrm}{m}$. The magnified picture of the surface of vane disc revealed that the abrasive wear was the principal cause of discharge flow rate degradation. Hence, this study revealed that high efficiency filter on the contaminant particle size range of 30${\mu}{\textrm}{m}$∼70${\mu}{\textrm}{m}$ especially should be used to maintain the service lift of the fuel filter.