• Title/Summary/Keyword: contact safety factor

Search Result 95, Processing Time 0.023 seconds

Scour Impact on the Horizontal Bearing Capacity of Pier-Type Dolphin Structures (잔교식 돌핀 구조물의 수평 지지력에 세굴이 미치는 영향 검토)

  • Tae Young Jeong;Su Won Kang;Kyu Won Kim;Jong Hwa Won;Chan Joo Kim
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.35 no.6
    • /
    • pp.138-145
    • /
    • 2023
  • A study using numerical analysis techniques was conducted to examine the scour effect of pier-type dolphin structures installed in the domestic marine environment, and the effect of scour on horizontal bearing capacity was examined. In this study, we designed the berthing structures, taking into account the environmental and ground conditions of the target maritime area, and after calculating the predicted scour area, stability evaluation was performed by removing the ground elements of the area. The increase in scour depth was found to induce a direct decrease in horizontal bearing capacity due to soil loss in contact with the foundation, establishing a relationship that increases horizontal displacement. However, in the foundation designed to withstand the design load by reflecting the safety rate, the increase in horizontal displacement formed by possible scour is not large, which did not have a dominant effect on the horizontal bearing capacity of the foundation. In the future, research is required to analyze the impact of each factor and formalize evaluation and design techniques to evaluate the scour safety of marine foundations and pier-type structures installed in various ground conditions and structural formats.

Screening for Anti-inflammatory Activities in Extracts from Korean Herb Medicines (국산 생약 추출물의 항염증 활성 스크리닝)

  • An, Sang Mi;Kim, Hyoung Gun;Choi, Eun Jung;Hwang, Hyoung Hoon;Lee, Eunseok;Baek, Ji Hwoon;Boo, Yong Chool;Koh, Jae Sook
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.40 no.1
    • /
    • pp.95-108
    • /
    • 2014
  • Cosmetics are products used over long periods by the public, and their safety is very important. Contact dermatitis induced by cosmetics is the result of an inflammatory response of the skin to direct irritancy. The initial event that this inflammatory response is observed is the release of pro-inflammatory cytokines. In this study, the anti-inflammatory activities of extracts from Korean herb medicines were investigated using RAW264.7 macrophage. Among the fifty one extracts tested, the ethanol extracts from Biotae Orientalis Folium, Biotae Orientalis Folium (roasted), Cyperi Rhizoma, Nepetae Spica, Benincasae Semen, Dioscoreae Rhizoma, Dioscoreae Rhizoma (roasted), Mori Ramulus, Pini Ramulus and Alismatis Rhizoma reduced the cytotoxicity and inhibited the productions of Nitric oxide (NO) and cytokines such as interleukin (IL)-1${\beta}$, IL-6 and tumor necrosis factor (TNF)-${\alpha}$n lipopolysaccharide (LPS)-induced RAW264.7 macrophage. Additionally, they didn't induce the skin irritation when tested the human patch test. Overall, the result of this study suggests that the extracts of the ten Korean herb medicines are useful cosmetic agents for preventing the skin irritation.

Human Dermal Risk Assessment on Chlorpyrifos of Korean Farmers (우리나라 농민의 Chlorpyrifos에 대한 피부 위해성 평가)

  • 정경미;이효민;이은희;이선희;김진화;심영용;홍진태;이용욱
    • Environmental Mutagens and Carcinogens
    • /
    • v.22 no.3
    • /
    • pp.187-198
    • /
    • 2002
  • Chlorpyrifos is an organophosphate insecticide and one of the most commonly and widely used insecticide. However, a little known about the dermal risk of chlorpyrifos on human being. Therefore, this study was conducted for the dermal risk assessment after exposure to chlorpyrifos in Korean farmers. First, skin irritation by chlorpyrifos (10 mg/$\textrm{cm}^2$, 50 mg/$\textrm{cm}^2$, 100 mg/$\textrm{cm}^2$, 250 mg/$\textrm{cm}^2$ in acetone) was determined in rabbits for 5 days considering the usage of chlorpyrifos short term highly exposure. The index of skin irritation by chlorpyrifos was increased in each dose and length of exposure dependent manners. Next, using benchmark dose (BMD$_{5}$) approach, the dose-response relationship was assessed to calculate the reference dose (RfD). The value of RfD was 2.84 $\mu\textrm{g}$/kg/day from 142.16 $\mu\textrm{g}$/kg/day BMD5 value divided uncertainty factor 50. Finally, we assessed human dermal risk of chlorpyrifos with exposure level and RfD. Skin absorbed levels were assumed with several exposure scenarios encounting the circumstances of exposure that application method, protection equipment and cloth, exposure time and exposure frequency during chlorpyrifos spraying. By the comparison of skin absorbed dose with the reference dose, it was identified that risk values (risk index) to skin chlorpyrifos exposure were 0.958 from the point of above results and it was recommended that the occurrence of hazard effect (skin irritation toxicity) of chlorpyrifos would not be expected. Risk index was smaller than 1 in the case of spraying vehicle mounted application, 1hour exposure time and wearing protective cloth exposure. Whereas, risk index was above 1 in the case of hand-held application, 2hour exposure time and wearing common cloth. Comparing two kinds of application method, total risk index of the hand held application (1.67) was higher than vehicle mounted (0.27). Therefore, chlorpyrifos skin exposure was mainly affected by application equipment and applied form. The results of risk assessment on the human dermal toxicity of chlorpyrifos should be required to control in keeping safety rules, skin surface area available for contact, spraying time ,and spraying frequency.y.

  • PDF

A Study on Electrode Array for Measurement of Induced Polarization of Rock Samples (암석 시료의 유도분극 측정을 위한 전극배열 비교)

  • Man-ho Han;Jung-hwan Lee;Keun-Soo Lee;Myeong-Jong Yi
    • Tunnel and Underground Space
    • /
    • v.33 no.6
    • /
    • pp.483-494
    • /
    • 2023
  • Measurement of the physical properties of rocks or minerals is an important factor in determining the distribution of the underground medium as well as mineral resource investigations. Resistivity and induced polarization, which are widely used in Korea, are methods for measuring electrical properties, which are representative properties of obtaining subsurface information. In order to precisely analyze the exploration data obtained from various sites, it is important to accurately measure the material properties. Electrical properties of rock is measured using two-electrode or four-electrode method. Compared to the four-electrode method, the two-electrode method is generally used because it is very easy to contact the sample and the electrode, but there is a problem in that the impedance of the electrode and the sample is measured together. In this study, the time-domain the induced polarization effects were measured using the 2-electrode method and the 4-electrode method for artificial samples mixed with graphite and cement having induced polarization characteristics, and the results were compared. Although the 4-electrode method has difficulties in installing potential electrodes, it was confirmed that it is effective in measuring electrical properties because it can reduce the problem caused by the impedance of potential electrodes compared to the 2-electrode method.

Study on Fire Hazard Analysis along with Heater Use in the Public Use Facility Traditional Market in Winter (겨울철 다중이용시설인 전통재래시장 난방기구 사용에 따른 화재 위험성 분석에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.4
    • /
    • pp.583-597
    • /
    • 2014
  • Fire caused by heater has various causes as many as the types of heater. also, lots of damage of human life and property loss are caused, since annually continuous fire accident by heater in traditional market is frequently occurring. There are not many cases of fire due to heater in most of residential facilities such as general house, apartments, etc., because they are supplied with heating boiler, however the restaurant, store and office of the market, sports center, factory, workplace, etc. still use heater, e.g. oilstove, electric heater, etc., so that they are exposed to fire hazard. Also, when investigating the number of fire due to heater, it was analyzed to occur in order of home boiler, charcoal stove, oilstove, gas heater/stove, electric stove/heater, the number of fire per human life damage was analyzed in order of gas heater/stove, oil heater/stove, electric heater/stove, briquette/coal heater. Also, gas and oil related heater were analyzed to have low frequency, however, with high fire intensity. Therefore, this research aimed at considering more scientific fire inspection and identification approach by reenacting and reviewing fire outbreak possibility caused by combustibles' contact and conductivity under the normal condition and abnormal condition in respect of ignition hazard, i.e. minimum ignition temperature, carbonization degree and heat flux along with it, due to oilstove and electric stove, which are still frequently used in public use facility, traditional market, and, of which actual fire occurrence is the most frequent. As the result of reenact test, ignition hazard appeared very small, as long as enough heat storage condition is not made in both test objects(oilstove/electric stove), however carbonization condition was analyzed to be proceeded per each part respectively. Eventually, transition to fire is the ignition due to heat storage, so that it was analyzed to ignite when minimum heat storage temperature condition of fire place is over $500^{\circ}C$. Particularly, in case of quartz pipe, the heating element of electric stove, it is rapidly heated over the temperature of $600^{\circ}C$ within the shortest time(10sec), so that the heat flux of this appears 6.26kW/m2, which was analyzed to result in damage of thermal PVC cable and second-degree burn in human body. Also, the researcher recognized that the temperature change along with Geometric View Factor and Fire Load, which display decrease of heat, are also important variables to be considered, along with distance change besides temperature condition. Therefore, the researcher considers that a manual of careful fire inspection and identification on this is necessary, also, expects that scientific and rational efforts of this research can contribute to establish manual composition and theoretical basis on henceforth fire inspection and identification.