• Title/Summary/Keyword: contact lens Fitting

Search Result 41, Processing Time 0.03 seconds

A Study of Ultrastructure on attachment of Soft Contact Lens Surface of Incubated Pseudomonas aeruginosa (배양된 Pseudomonas aeruginosa의 소프트 콘택트 렌즈 표면부착에 대한 미세구조적 연구)

  • Kim, Douk Hoon;Park, Yong Tae;You, Hae Byung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.11-14
    • /
    • 2000
  • The soft contact lens was very simple technique in handling, good sensation in fitting, good effect of a beauty, and good attachment state on the cornea in physical movement. So that, the subjects have used the correct of visual acuity. If the contact lens handling have not skill, they have acquired the side effect on eye. To analysis of a study of ultrastructure on soft contact lens surface of incubated P. aeruginosa. We have observed the soft contact lens surface by SEM. We have founded the good technical method. On the method of sample process of manufacture, the best observation of samlpe tissue was $OsO_4$ postfixation and tannic acid treatment. In this case, P. aeruginosa was a rod shape and one cilia in ultrastructure and the identification was very good. But, On the process of manufacture have not used the $OsO_4$ and tannic acid treatment, this tissue sample appeared the foreign body materials and artifacts, and the identification of the P. aeruginosa was very difficult.

  • PDF

The Effect of Hair Spray on the Fitting of Contact Lenses (헤어스프레이가 콘택트렌즈의 피팅에 미치는 영향)

  • Chung, Jin Young;Kim, Dae Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.1
    • /
    • pp.1-8
    • /
    • 2002
  • Various kinds of aerosols such as a mixture of hairspray resin and its solvents, a perfume, a soap water, and ask in-lotion were sprayed onto the contact lens which was mounted on the eye-model made of wood, varying the parameters as the distance between nozzle and contact lens and the spraying time duration. In the case of both the hairspray and the perfume including an ethanol as solvents, the shape of contact lenses has changed tremendously Jess than 1 minute after the exposure to the aerosol particles and then it continued until the lens surfaces were completely flipped over. Driving force for the lens distortion seems to be the expansion coefficient difference between the inner and outer surface of lens, which was caused by the heat of vaporization of ethanol included in the aerosol and subsequent temperature decrease induced on the lens surface.

  • PDF

Effectiveness of Overnight Orthokeratology with a New Contact Lens Design in Moderate to High Myopia with Astigmatism

  • Park, Yuli;Kim, Hoon;Kang, Jae Ku;Cho, Kyong Jin
    • Medical Lasers
    • /
    • v.10 no.4
    • /
    • pp.229-237
    • /
    • 2021
  • Background and Objectives To assess the effectiveness of overnight orthokeratology (OK) in myopia using a new contact lens design over a one-month wearing period. Materials and Methods Participants were required to have myopia between -3.00 and -7.50D and astigmatism ≤ 2.00 D to participate in the study. The participants underwent OK with the White OK lens® (Interojo, Pyungtek, Korea), which has a 6-curve lens design. Participants were assessed at weeks 1, 2, and 4 using slit-lamp bio-microscopy, and tested for refraction, uncorrected distance visual acuity, and corneal topography. Success was defined as achieving a Logarithm of the Minimum Angle of Resolution (logMAR) ≤ 0.1. Results A total of 46 eligible subjects with a mean age of 23.11 ± 7.89 years were recruited. Baseline logMAR was 1.18 ± 0.30 and a consistent decrease in logMAR was observed from week 1 to week 4. The success rate was 95.35% at week 4. The mean sphere significantly decreased from a mean pre-fitting value of -4.58 ± 1.28 D to a mean value of -0.65 ± 0.69 D at week 4 (p < 0.0001). Statistically significant corneal flattening was detected during keratometry at week 4. Conclusion Overnight OK with the White OK lens is effective for the correction of moderate and high myopia with astigmatism over a one-month wearing period.

A Study on the Change of Corneal Refractive Power before and after Wearing RGP Contact Lenses by Flat Fitting and Alingment Fitting with Diagnostic Method (RGP 콘택트렌즈의 진단적 피팅법에 의한 플랫한 피팅과 얼라인먼트 피팅 착용 전·후 각막 굴절력의 변화에 관한 연구)

  • Lee, Dae-Won;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.163-169
    • /
    • 2014
  • Purpose: This study is for compared the change of corneal refractive power before and after wearing of rigid gas permeable contact lense with diagnostic method which is 1 D flatter than alignment fitting on right eye and alignment fitting on left eye for 2 months and investigate the preference. Methods: Twenty middle school and high school students (40 eyes) who had never worn a contact lense before for no corneal topographical change, no ocular disease, no experience of ophthalmic surgery and have normal tear amount were selected for this study and corneal refractive power were examined before wearing rigid gas permeable contact lense and adaptation status and corneal examination were performed after 10 days of wearing and after cheking up the continuation of wearing, all candidate wear contact lens 8 hours per day for 2 month and corneal refractive power were compared. Results: After 2 months of wearing with 1 D flatter than the alignment fitting on right eyes, there was significant difference in the central corneal refractive power was $43.84{\pm}1.33D$, flat K power was $43.05{\pm}1.29D$, and steep K power was $44.61{\pm}1.42D$ decreased than before wearing (p<0.001, 0.001, 0.047). The e-value of the principal meridians also shows statistically significant difference (p=0.037, 0.015). After 2 months of wearing with alignment fitting on left eyes, the central corneal refractive power was $44.40{\pm}1.26D$, flat K power was $43.57{\pm}1.23D$. and flat K e-value was $0.58{\pm}0.05$ which showed no statistically significant difference (p = 0.769, 0.614, 0.181). But steep K power was $45.25{\pm}1.36$, and steep K e-value was $0.45{\pm}0.18$ which shows statistically significant difference (p=0.018, 0.027). Conclusions: Consider the comfort, clear vision, dryness for preference fitting investment, 6 students (30%) prefer right eye which is 1 D flatter fitting, 14 students (70%) prefer left eye which is alignment fitting. For rigid gas permeable fitting needed for accurate examination and should prescribe the alignment fitting which is suitable for each cornea.

Use of Piggyback Contact Lens System to GP Lens Wearers (GP렌즈 착용자에게 피기백 콘택트렌즈 시스템의 적용)

  • Kim, Yong Gil;Kim, Soo Hyun;Kim, Jai Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.47-53
    • /
    • 2010
  • Purpose: This study was performed to achieve an acceptable piggyback fit utilizing each subject's own GP lenses, in subjects with regular low myopic astigmatism. Methods: A randomized, prospective study of 15 subjects with the diagnosis of low myopic astigmatism was conducted. Nine subjects were female and 6 were male, and mean age was: 23.73${\pm}$1.68 years. Subjects were evaluated before participate on this study and then also evaluated with period of at two hours and two weeks after obtaining their lenses. All subjects were submitted to the following tests: measurement of comfort level by means of the analogical visual scale, best corrected visual acuity and over-refraction at distance. contrast sensitivity and stereo acuity. After evaluating the fit of plano soft lens, we applied each subject's own GP lens on top. Results: Vision, visual performance and satisfaction of piggyback contact lens system were stable, if not improved, for the 15 subjects when the data was compared to the patients' wear of rigid gas permeable contact lenses. Fit with a piggyback system had the same or improved comfort, visual acuity and contrast sensitivity compared to previous GP lens wear alone. The visual acuity, contrast sensitivity and stereo acuity did not show differences in relation to the studied lens type. Conclusions: These results suggest that it is possible to achieve a successful piggyback lens fitting utilizing a patient's own GP lens. The piggyback lens system satisfied the visual performance and visual requirements of this subject with GP lens alone for the correction of low myopic astigmatism.

A Study on a Changed Power of Tear lens at Spherical RGP lens Fitting (구면 RGP렌즈 Fitting시 누액렌즈 굴절력 변화에 대한 연구)

  • Park, Seong-Jong;Joo, Seok-Hee;Jung, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.455-462
    • /
    • 2004
  • In this paper, we measured and analysised the power change of tear lens for 85 patients - 170 myopia eyes - who are fitted using RGP lens, considering the BGR of RGP lens, the corneal astigmatism power, and corneal curvature. We got the following results from these experiments; 1. When the BCR of RGP lens changes, the diopters of tear lens of "on-k", 0.05Pt, 01.0Ft, 0.05St, and 0.10St are -0.25D, -0.46D, -0.63D, +0.07D, and +0.26D, respectively. 2. When the corneal astigmatism power changes, the diopters of tear lens of group below 0.75D, group of 1.00D~1.25D, group of 1.50D~1.75D, and group over 2.00D in "on-k" state, are -0.25D, -0.18D, -0.09D, and -0.39D, respectively. 3. When the corneal astigmatism power changes and the BCR of test lens is changed by 0.05mm step, the change values of tear lens diopter for 0.05St and 0.05Ft approximate to ${\pm}0.25D$, while these for 0.10St and 0.10Ft don't approximate to the value below ${\pm}0.25D$.[are irregular value below ${\pm}0.25D$.] 4. When the corneal curvature and the HCR of RGP lens change, the diopters of tear lens of group below 7.50mm, group of 7.55~7.80mm, group of 7.85~8.20mm, and group over 8.25mm in "on-k" state, are -0.40D, -0.11D, -0.20D, and -0.19D, respectively. 5. When the BCR of test lens is changed by 0.05mm step and the corneal curvature increases, the change values of tear lens diopter decrease, while these over 8.25mm are mean value ${\pm}0.17D$ and the value below ${\pm}0.25D$.

  • PDF

A Study on Prescription of RGP Contact Lens in Korean Optometrist (안경사의 RGP콘택트렌즈 처방 실태조사)

  • Kim, Young-Hoon;Baarg, Saangbai;Kim, Kwang-Bae;Kim, Dae-Hyoun;Lim, Byung-Kwan;Sun, Kyoung-Ho
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.7-17
    • /
    • 2007
  • There has been an increase in rigid gas permeable contact lens prescription by the optometrists in Korea since 1995. Therefore, the aim of our study was to find out which equipment is needed for adequate RGP contact lens prescription and the level of the clinical knowledge that they have and the level of education for the patient, to seize about the extended lens education programmes for the Korean optometrist. Also, we tried to figure out the problem that they had in the RGP contact lens prescription, to develope the educational programs for students and to improve legal uncertainties, through this research. The result came out with the following through questionnaires of 400 male and female opticians who is in clinical field. The distributions of respondents are 270 male (67.5%), 130 female (32.5%), and 356 optometry major (89%). We found out the optometry-majored people had faster clinical lens prescriptions (p=0.000), 72.5% of opticians prescribe the RGP-Lenses, and 27.5% do not because of laking in experience (P=0.000). They responded that they need slit-lamp, button lamp, fluorescein dry paper, and etc,for prescription or fitting test. In regular-check-up (Follow-up), the result came out very low by 83% of respondents who are not getting it regularly. And 83.5% (334 people) of them wanted to have those Extended Educational Programs and also the Clinical Education Programs.

  • PDF

The Efficacy and Effect of Reverse Geometry Contact Lens on Cornea (역기하학 렌즈의 유효성과 각막에 미치는영향)

  • Kim, Kwang-Bae;Kim, Young-Hoon;Bark, Sang-Bai;Sun, Kyung-Ho;Jeong, Youn-Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.2
    • /
    • pp.1-12
    • /
    • 2007
  • Object of this research is to estimate the effect of myopia correction and safety on reverse geometry contact lens fitting in school children. This research include 53(106eyes) schoolchildren among 7 to 18 years who has low to moderate myopia(-1.00D~-5.00D) and prescribed reverse geometry contact lens for purpose on orthokeratology between January to July 2004 and had 3months full follow up examination. They were tested for slit lamp examinations, BUT(Break up time), direct ophthalmoscopy, retinoscopy, uncorrected visual acuity, best corrected visual acuity, autorefraction, autokeratometry and corneal topography in each examination(1day, 1week, 2weeks, 1, 2, and 3months) of before-and-after lens wearing to find out the effect of myopic correction and side effect. The results came out as follow. The average of uncorrected visual acuity was $0.0938{\pm}0.378$ before lens wear and $0.3136{\pm}0.283$ after 1day lens wear, and there was fast improvement after 1week($0.7925{\pm}0.301$) and little improvement after 2weeks period but still they shows better uncorrected visual acuity(p<0.01). The result of this study, the reverse geometry lens is very useful to correct refractive error and control the progression of myopia temporally among low to moderate myopic patient. The side effects were relatively rare but further study should be necessary with long term lens wear effect on eye health. For the lens prescription, the clinical fitting process had higher rate of success with consideration of eccentricity and corneal topography.

  • PDF

A Correlation between Axis-Rotation and Corneal Eccentricity in Toric Soft Contact Lens Fitting in With-the-rule Astigmatism (직난시안에서의 토릭소프트렌즈 피팅 시 축 회전과 각막이심률과의 상관관계)

  • Park, Hyung Min;Park, Kyounghee;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.305-313
    • /
    • 2014
  • Purpose: A correlation between the rotating direction and rotation amount according to the eccentricity was analyzed in the present study when fitting the toric soft contact lens. Methods: One hundred fourteen eyes of with-the-rule astigmatism in 20s and 30s were appropriately applied toric soft contact lens by the guideline of manufacturer and fitting evaluations and analyzed the rotating direction and rotation amount when fixating at primary position and 8 different directions of gaze. The speed of reorientation and the correlation between the rotation amount and cornea eccentricity were also analyzed when rotating $45^{\circ}$ each toward the temporal and nasal direction. Results: The cornea eccentricity and rotation amount was shown positive correlation. For the gaze of direction, it was identified that the gaze of directions other than the gaze of direction towards the nasal and temporal had correlation, and among them, the gaze of directions to superior and the superior-temporal showed the tendency of decreasing rotation amount as the cornea eccentricity increased. On the contrary, the gaze of direction towards the inferior, inferior-temporal, superior-nasal, and inferior-nasal showed tendency of increasing rotation amount as the cornea eccentricity increased thus, it was identified that the cornea eccentricity showed different correlation according to the gaze of direction. For the case of re-orientational speed, the speed of lens reorientation in the group having the smallest corneal eccentricity was fastest in both direction but was not significantly different. Conclusions: Considering cornea eccentricity to current method of prescribing toric soft contact lens which is based on total astigmatism, it will be helpful to establish the optimal axis stabilization.

Analysis on Forces Acting on the Contact Lens Fitted on the Cornea (콘택트 렌즈에 작용하는 힘의 해석)

  • Kim, Dae-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.1-11
    • /
    • 2002
  • A mathematical model is proposed to analyze the force; acting on the hard contact lens fitted on the cornea. The model incorporates the nonlinear equations and their numerical solution program, based on the formulations of surface tension force arising from the capillary action in the tear-film layer between the lens and cornea. The model simulates how the adhesion between lens and cornea varies according to the base curves and diameters of the lenses. When the spherical lens is fitted on the spherical cornea it is to rotate downward due to the weight of lens itself until it reaches an equilibrium position along the cornea where the counter(upward) moment caused by net force between the upper and lower portion of the periphery of lens. It is found that both the adhesion and displacement of lens along the cornea, where the gravity of lens balances the capillary-induced upward force, increases rapidly as the base curve of lens increases, i.e., as the lens gets flatter, while the increase in the diameter of lenses has resulted in the less increase in the rotation and adhesion. With the base curve and diameters of lenses being remained constant the increase in surface tension of tear film yields the increase in the adhesion between the cornea and lens while the initial rotation of lens is inversely proportional to the surface tension of the tear film.

  • PDF