• Title/Summary/Keyword: contact lens

Search Result 397, Processing Time 0.027 seconds

The Clinical Study on the Visual Acuity and Cornea of ez-NANOsence II RGP Contact Lens (ez NANOsence II RGP 콘택트렌즈의 시력과 각막에 미치는 임상적 연구)

  • Kim, Douk-Hoon;Bae, Han-Young;Han, Mung-Gyo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.55-69
    • /
    • 2007
  • The purpose of this study was to perform a clinical test using ez NANOsence II RGP contact lenses for the effects of visual acuity and cornea on subjects with abnormal refraction status. One hundred twenty one adults (twenty nine males, ninety two females, range = 17 to 43, mean = 22.86) were recorded. The subject's history including, the symptoms from previous lens wear, were studied. The subjects were observed, both pre and post lens wear, for any symptoms and signs of change of the eye. The Visual acuity and the binocular status were tested at the far distance using the contact lens. The refraction test was performed on the naked eye using the objective method (Topcon KR-8100, Japan). The Stereopsis test was performed at the near distance after contact lens wear by the Titmus fly (Stereo Optical Co., U.S.A) and TNO (TECH, The netherlands). The contrast sensitivity diagnosis was performed at 1m distance after contact lens wear by the contrast sensitivity chart (pelli-Robertson, USA). The corneal topography was analyzed on the naked eye after lens wear by ORB scan (Bausch Lomb, U.S.A.). The ultra structure of surface on the contact lens was observed using SEM (JMS-5800, Japan). The chemical component's of the contact lens was analyzed by EDS program. The results of this study were as follows: 1. The longer of contact lens wear period, The subjects have acquired the most improved visual function. 2. Subjects had experienced few side effects wearing the contact lenses. 3. The lenses were easy to use by the subjects. 4. The longer of contact lens wear period, the power of cornea had more decrease. but the base curve of cornea had more increase and corneal astigmatism was decrease (p<0.01). Also, the thickness of corneal center was few decrease. 5. Longer periods of using the contact lens showed stereopsis and contrast sensitivity at more normal values. 6 The corneal topographical after lens wear showed most subjects with similar morphology for different wear periods. 7. The surface ultrastructure of the new and used contact lens was the similar fine shape. 8. The chemical component's of in the new and used contact appeared to have similar results. In conclusion, this study showed that the surface ultrastructure and chemical component's of the new and used contact lens are similar. In addition, the subjects had improved the quality of vision and few experienced any side effects during long periods of contact lens wear. Also they have decrease of corneal astigmatism during the long period of lens wear. Our test has showed that the chemical composition and fine structure of contact lens have related to the visual function on contact lens wearer. In this paper, we suggested that ez NANOsence II RGP contact lenses had a moderate effect for correcting vision of abnormal refraction eye.

  • PDF

Biosafety of the New Soft Contact Lens Materials in the Fibroblast L-929 Cell Line (흰쥐의 섬유아세포 L-929를 이용한 새로운 Soft Contact Lens 소재의 생물안전성 검증)

  • You, Young-Hyun;Nam, Joo-Hyeung;Kim, Bieong-Kil;Kim, Soon-Bok;Moon, Ik-Jae;Kim, Jong-Pil;Seu, Young-Bae
    • Microbiology and Biotechnology Letters
    • /
    • v.37 no.1
    • /
    • pp.75-79
    • /
    • 2009
  • In this study, we polymerized new materials for soft contact lens using HEMA (2-hydroxyethyl methacrylate) which is the based-monomer of soft contact lens, EGDMA (ethylene glycol dimethacrylate) as cross linkage agent, and the new additives of monoester or di-ester derived from itaconic acid commercially produced by the fermentation of Asp. itaconicus. New polymer materials for soft contact lens were synthesized with the mixture of HEMA and mono- or diester at different ratios and presented to a good water content and oxygen transmissibility (Dk/L) values. In case of polymerization with HEMA and mono-ester (15%), the water content and oxygen transmissibility of contact lens were found to be good values at 57.6% and 28.5 Dk respectively. The mixture of HEMA and mono-ester is more excellent than HEMA/di-ester in the water content and oxygen transmissibility. The toxicity of new contact lens materials were confirmed in the fibroblast L-929 cell line using a agar overlay test and a growth inhibition test with the extract solution of contact lens.

Elution Properties of Naringin from Soft Contact Lens Containing Naringin (나린진(naringin)이 함유된 소프트 콘택트렌즈에서 나린진의 용출 특성)

  • Ryu, Geun-Chang;Jun, Jin;Jin, Moon-Seok;Chae, Soo-Chul;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.45-50
    • /
    • 2008
  • Purpose: A soft contact lens was manufactured by adding naringin known as natural anti-bacterial material to resin solution. With solution eluted from manufactured contact lens, we examined its optical properties, physical and chemical states of naringin in the polymer, and elution properties. Methods: The soft contact lens with naringin was synthesized by bulk polymerization method. IR spectrum and HPLC were used to define the bonding type of naringin itself in the soft contact lens contained naringin, elution process of naringin to the saline solution, and the amount of naringin solution eluted from the lens with elapsed time. Results: Naringin was continuously eluted with constant concentration from the soft contact lens for about a month and the structure ofnaringin which is eluted was as same as before it was added to resin solution. Any change in optical properties such as transmittance couldn't be found. Bonding state and the structure of naringin in contact lens were explained with IR spectrum and HPLC results. Conclusions: In the contact lens with naringin, naringin remained in the contact lens bonding with weak hydrogen bonding and/or van der Waals force between naringin and polymer. Naringin was continuously eluted from the contact lens contained naringin during about 1 month. Even after 1 month, it showed that the concentration of the naringin eluted was approximately 10 ppm in a day. From the results, adding naringin to the soft contact lens resin is very effective method for manufacturing the soft contact lens which has anti-bacterial function for a period of time.

  • PDF

Dry Eye Syndrome and Ocular Fatigue according to the Status of Contact Lens Wearing and Management among Female University Students (여대생의 콘택트렌즈 착용 및 관리 실태에 따른 안구건조증과 눈 피로)

  • Her, Sun;Kim, Kye Ha
    • Research in Community and Public Health Nursing
    • /
    • v.25 no.4
    • /
    • pp.259-269
    • /
    • 2014
  • Purpose: The purpose of this study was to examine dry eye syndrome and ocular fatigue according to the status of contact lens wearing and management among female university students. Methods: The subjects were 195 female university students wearing contact lenses. Ocular Surface Disease Index (OSDI) and Virtual Reality Symptom Questionnaire (VRSQ) were used to determine the level of dry eye syndrome and ocular fatigue. The SPSS/WIN 21.0 program was used for analysis of data. Results: Significant differences in the level of dry eye syndrome were observed according to the period of case solution change (F=3.36, p=.037) and the reasons for the change of lens (F=4.56, p=.004). In ocular fatigue, significant differences were observed according to the price of lens (F=3.53, p=.031), rinse in storing lens in a case (t=-2.57, p=.011), and learning about contact lens (t=-2.01, p=.046). A significant positive correlation was observed between dry eye syndrome and ocular fatigue in the subjects. Conclusion: The results of this study show that some subjects have problems in wearing and management of contact lenses. Therefore, an education program related to contact lenses should be provided to contact lens wearers to improve the status of wearing and management of contact lenses.

A Study of Internal Ultrastructure on the RGP Contact Lens (RGP 콘택트 렌즈의 내부 미세구조에 대한 연구)

  • Kim, Douk Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.55-58
    • /
    • 2001
  • The rigid gas permeable(RGP) contact lens has nearly side effect on the cornea. So that, this lens has used the clinical reflective correction of the eye. This study have used several methods for research the fine internal structure on the RGP contact lens by scanning electron microscopy. The results have indicated that the postfixation of 1% $OsO_4$ and tannic acid is responsible for a fine structure in the internal plane of RGP contact lens. These internal surface of contact lens appeared the several shape of the hole of the stereo shape form with arrangement of round form. But, on the contact lens with non-postfixation, the stereo shape have not present and the boundary of the vesicle have not clear. Maybe, these results suggest that the fixation methods have effect on the morphological characters of materials on the RGP contact lens.

  • PDF

The status of care for Soft Contact Lens and periodic examination (연성 콘택트렌즈의 관리 및 정기검사 실태)

  • Shin, Jang Cheol
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.107-113
    • /
    • 2000
  • This study has analyzed soft contact lens care-after-sale and periodic examinations at optical shops and eye clinics. And I wish to make that use of educational data for the soft contact lens lesson of the department of ocular optics. This questionnaire studied the status of care for soft contact lens and periodic examination, of students who wears soft contact lens. The results are as follows: First, 7.5% of students questioned wore soft contact lens. More women than men wore soft contact lens. The soft contact lens wearers purchased lens mainly at optical shops. 78.5% of them wore daily wear lens. Because of cosmetic advantages of soft contact lens. 47.9% of them wore soft contact lens. 72.5% of them wore soft contact lens less than 12 hours per a day. 32.0% of them has worn soft contact lens more than 6 months less than 1 year. 51.1% of them experienced irritation. 39.7% of them have exchanged soft contact lens between 6 and 9 months. Secondly, when purchasing lenses. 60% of soft contact lens wearers were given instructions of general care, such as duration of wearing lens, how to remove protein, how to store, and how to sterilize at both of eye clinics and optical shops. But the proportion of instructions, such as side effects and periodic examination which were given to soft contact lens wearers, is lower both at eye clinics and optical shops. Especially at optical shops, the proportion of instruction for periodic examination, is lower than at eye clinics(p<0.05). Thirdly, The proportion of operations of periodic examinations after use of soft contact lens both at eye clinics and optical shops, is low. The soft contact lens wearers have had more periodic examinations at eye clinics than at optical shops. But the rate of non-periodic examination at optical shop is 87.9%. And for periodic examinations, general care was done at optical shops. On the other hand, eye examinations, general care, and treatments were done more at eye clinics. Fourthly, 60.3% of the soft contact lens wearers understood the necessity of the periodic examinations, but actually, only 6.4% of them were given the schedule for the periodic examinations, and 2.5% of them were given at an optical shop(p<0.01).

  • PDF

A Study on the Optical Properties of Contact Lens Analyzer CA-20 (CONTACT LENS ANALYZER CA-20의 광학계 성능 조사)

  • Ji, Taeksang;Lim, Hyeonseon;Kim, Bonghwan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.199-203
    • /
    • 2000
  • Magnification shall large to test a surface of a contact lens also chromatic aberration and distortion to be removed. Be used of this study a contact lens analyzer is "CONTACT LENS ANALYZER CA-20", it is a good analyzer to suitable with surface test 16 times of big magnification and distortion.

  • PDF

A Study on Protein Adsorption-resistant Soft Contact Lens (단백질흡착을 막는 소프트콘택트렌즈에 관한 연구)

  • 조종수;정영일
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.3
    • /
    • pp.291-296
    • /
    • 1996
  • Poly(ethylene glycol)(PEG) macromers terminated with diacrylate Iyoups and interpenetrating poly- mer networks(IPN) composed of poly(hydroxyethyl methacrylate)(PHEMA) or poly(hydroxyethyl methacrylate-co-hydronypropyl methacrylate-co- N-vinyl pyrrolidone ) [ P( HEM A-co- HPM A-co- NVP) ] and PEG macromer were synthesized with the aim of obtaining protein adsorption resistant soft contact lens. Polymerization of PEC macromer resulted in the formation of cross-linked gels due to the multifunctionality of macromer. Crosslinked P(HEMA) or P(HEMA-co-HPMA-co-WVP) chains were interpenetrated into the cross-linked three-dimensional networks of PEG. It was found that albumin adsorption onto the contact lens prepared by P(HEMA-co-HPMA-co-NVP) /PEG IPW decreases with an increase of molecular weight of PEG. Also, it was found that albumin adsorption onto the both contact lens decreases with an increase of concentration of PEC macromer in the IPN preparation. There are also more adequate in the bioinertnen for the contact lens by P(HEMA)/PEG IPN or P (HEMA-co-HPMA-co-NVP)/PEG IPN than that by P(HEMA) or P(HEMA-co-HPMA-co-NVP)

  • PDF

The Change in the Amounts of Proteins and Lipids Deposited on Soft Contact Lens Caused by Drinking (음주로 인한 소프트콘택트렌즈의 단백질 및 지질 침착양 변화)

  • Kim, So Ra;Lim, Shin Gyu;Bae, Seok Chun;Choi, Jung Hyun;Park, Sang Hee;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.233-239
    • /
    • 2012
  • Purpose: In the study, the change of protein and lipid deposits on soft contact lens by drinking was investigated. Methods: Fifty male subjects wearing soft contact lens were surveyed whether they felt any discomfort induced by drinking or not. Further, 32 male subjects who has no ocular disease drank 190 mL alcohol. The protein and lipid deposits on soft contact lens (etafilcon A material) of subjects were measured after 4 hours later and compared with those of non-drinking subject. Results: When subjects drink alcohol with soft contact lens on, 58% of subjects answered they experienced the change of lens awareness such as stiffness, blurry sight, dryness and so on. The protein deposit on soft contact lens increased an average of $59.3{\mu}g/lens$ by drinking and the case of more than double in protein deposit was reached in 9 eyes. However, the protein deposited on soft contact lens was lysozyme which was unchanged by drinking. The amounts of cholesterol and methyl oleate after drinking were 85.5% (p=0.25) and 52.6% (p=0.002) of non-drinking's indicating some change of lipid deposit on soft contact lens by drinking. Conclusions: The results showed the composition of protein and lipid deposited on soft contact lens was changed due to drinking. Thus, it is suggested that wearing soft contact lens when drinking might be one of the reasons to feel discomfort.

The role of domestic tap water in Acanthamoeba contamination in contact lens storage cases in Korea

  • JEONG Hae Jin;YU Hak Sun
    • Parasites, Hosts and Diseases
    • /
    • v.43 no.2 s.134
    • /
    • pp.47-50
    • /
    • 2005
  • A survey was carried out from August to December 2004 in Pusan, Korea to document the presence of free-living amoeba (FLA), including the genus Acanthamoeba, in both contact lens storage cases and domestic tap water. Acanthamoeba was isolated from $5(4.2\%)$ in 120 contact lens storage cases. Four house tap water samples from residents, whose contact lens storage cases had been contaminated by Acanthamoeba, were also found to be contaminated with Acanthamoeba. Therefore, the contamination rate of FLA and Acanthamoeba in domestic tap water was investigated in order to examine the role of domestic tap water in Acanthamoeba contamination of contact lens storage cases. FLA and Acanthamoeba were identified in $97(46.8\%)\;and\;16(7.7\%)$ of the 207 domestic tap water samples, respectively. There were no significant differences between the contamination rates of FLA in tap water according to the filtration plant of origin. No FLA was detected in the tap water directly supplied by the water purification plants. Water storage tanks appear to promote FLA colonization, including Acanthamoeba, in domestic tap water. This increases the risk of Acanthamoeba contamination in contact lens storage cases as well as increasing the risk of Acanthamoeba keratitis.