• Title/Summary/Keyword: contact length

Search Result 754, Processing Time 0.027 seconds

Studies on Strength of Netting (1) The Decrease in Strength of Netting Twines by Knotting (그물감의 강도에 관한 연구 (1) 그물실의 강도가 매듭에서 감소하는 기구)

  • KIM Dai An
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.9 no.1
    • /
    • pp.1-7
    • /
    • 1976
  • 1) The decrease in strength of netting twines at the knot may be regarded to be due mainly to the frictional force acting on the tip of the knot. The knot strength T may be given by $$T=\frac{T_0}{1+{\mu}\frac{s}{\rho}\varrho^{\mu\theta}$$ were $T_0$ is the tensile strength of unknotted netting twines, $\mu$ the coefficient of friction beween two netting twines forming a knot, s the contact length between the tip and the netting twine compressing it, $\rho$ the radius of curvature of the compressing, and $\theta$ the angle at which the compressing rubs with another one in the vicinity of the opposite tip. 2) Knots are arranged in order of strength as follows : the reef knot pulled lengthwise $\risingdotseq$ the trawler knot pulled breadtwise the reef knot pulled breadthwise.

  • PDF

A Study on the Dynamic Response of Highway Bridges by 4-Axles Single Truck (4축 단일차량에 의한 도로교의 동적응답에 관한 연구)

  • Chung, Tae-Ju
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.3
    • /
    • pp.397-404
    • /
    • 2011
  • In this paper, a research for the dynamic wheel loads of a 3D vehicle model, which relates to a tire-enveloping model, is carried out. A single truck with four axles is modeled as a 10-D.O.F. vehicle by modeling both contact length of tires and pitching of tandem spring axles. The dynamic equations of the vehicle are obtained using the Lagrange's equation, the solution of the equations is calculated by Newmark-${\beta}$ method. The validity of the developed 3D vehicle model is demonstrated by comparing results obtained from the proposed method with those from experimental data. The maximum impact factors of tire force are evaluated according to the various step bumps on which a 24-ton dump truck is running.

Comparison of mechanical and biological properties of zirconia and titanium alloy orthodontic micro-implants

  • Choi, Hae Won;Park, Young Seok;Chung, Shin Hye;Jung, Min Ho;Moon, Won;Rhee, Sang Hoon
    • The korean journal of orthodontics
    • /
    • v.47 no.4
    • /
    • pp.229-237
    • /
    • 2017
  • Objective: The aim of this study was to compare the initial stability as insertion and removal torque and the clinical applicability of novel orthodontic zirconia micro-implants made using a powder injection molding (PIM) technique with those parameters in conventional titanium micro-implants. Methods: Sixty zirconia and 60 titanium micro-implants of similar design (diameter, 1.6 mm; length, 8.0 mm) were inserted perpendicularly in solid polyurethane foam with varying densities of 20 pounds per cubic foot (pcf), 30 pcf, and 40 pcf. Primary stability was measured as maximum insertion torque (MIT) and maximum removal torque (MRT). To investigate clinical applicability, compressive and tensile forces were recorded at 0.01, 0.02, and 0.03 mm displacement of the implants at angles of $0^{\circ}$, $10^{\circ}$, $20^{\circ}$, $30^{\circ}$, and $40^{\circ}$. The biocompatibility of zirconia micro-implants was assessed via an experimental animal study. Results: There were no statistically significant differences between zirconia micro-implants and titanium alloy implants with regard to MIT, MRT, or the amount of movement in the angulated lateral displacement test. As angulation increased, the mean compressive and tensile forces required to displace both types of micro-implants increased substantially at all distances. The average bone-to-implant contact ratio of prototype zirconia micro-implants was $56.88{\pm}6.72%$. Conclusions: Zirconia micro-implants showed initial stability and clinical applicability for diverse orthodontic treatments comparable to that of titanium micro-implants under compressive and tensile forces.

Comparison between Resonance Frequency and Histomorphometric Measurements of Mandibular Implants in Beagle Dogs (비글견의 하악골에 식립된 임플랜트에 대한 공진주파수와 조직계측분석의 비교 연구)

  • Kim, Woo-Young;Jang, Kyung-Soo;Kim, Chang-Whe;Kim, Yung-Soo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.4
    • /
    • pp.291-296
    • /
    • 2003
  • The use of resonance frequency analysis (RFA) provides a possibility to clinically measure implant stability and osseointegration. The implant stability quotient (ISQ) value of RFA is well known that influenced by effective abutment length and stiffness of the implant in the surrounding tissues. Among these factors stiffness is not accurately defined histologically yet. And the purpose of this study was to find the histolgical relationship of RFA. 17 implants in 3 beagle dogs were used for this study. Among these implants 10 were survived for 7 months, 4 were survived for 3 months and 3 were immediate status after placement. Resonance frequency analyses were conducted and the dogs were sacrificed. Percentage of the bone to implant contact (BIC) in the interface, percentage of the mineralized bone (bone area) within the threads of the implant, and marginal bone level were measured under light microscopy. The correlation between resonance frequency and histomorphometric measurements were analysed and following results were obtained. 1. There was statistically significant correlation between ISQ value and BIC on healed implants. But ISQ value and BIC of all implants were not significantly correlated. (P<0.01) 2. Significant correlation between ISQ value and bone area was not found in this study. 3. There was statistically significant correlation between ISQ value and marginal bone level on all implants as well as on healed implants. (P<0.01).

A finite element stress analysis on the supporting bone and abutment screw by tightening torque of dental implant abutment screw (치과용 임플란트 지대주나사의 조임체결력에 따른 지지골과 지대주나사의 유한요소법 응력 분석)

  • Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.42 no.2
    • /
    • pp.99-105
    • /
    • 2020
  • Purpose: A study analysed the stress distribution of abutment screw and supporting bone of fixture by the tightening torque force of the abutment screw within clinical treatment situation for the stability of the dental implant prosthesis. Methods: The finite element analysis was targeted to the mandibular molar crown model, and the implant was internal type 4.0 mm diameter, 10.0 mm length fixture and abutment screw and supporting bone. The occlusal surface was modeled in 4 cusps and loaded 100 N to the buccal cusps. The connection between the abutment and the fixture was achieved by combining three abutment tightening torque forces of 20, 25, and 30 Ncm. Results: The results showed that the maximum stress value of the supporting bone was found in the buccal cortical bone region of the fixture in all models. The von Mises stress value of each model showed 184.5 MPa at the 20 Ncm model, 195.3 MPa in the 25 Ncm model, and 216.5 MPa in the 30 Ncm model. The contact stress between the abutment and the abutment screw showed the stress value in the 20 Ncm model was 201.2 MPa, and the 245.5 MPa in the 25 Ncm model and 314.0 MPa in the 30 Ncm model. Conclusion: The increase of tightening force within the clinical range of the abutment screw of the implant dental prosthesis was found to have no problem with the stability of the supporting bone and the abutment screw.

The Gaiting Behaviour of the Grass Crab, Hemigrapsus penicillatus on the Nettings (망지에 대한 풀게(Heyhigrapsus penirillatus)의 보행운동)

  • KIM Yong-Hae;KO Kwan-Soh
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.20 no.3
    • /
    • pp.177-184
    • /
    • 1987
  • The quantitative mechanics on the sideways walking of the crabs may provide a basic solution for entanglements of the walking legs in gillnets. The gaiting behaviour of the crabs on the flat board and the nettings 10, 16 and 23 mm in mesh size were experimented concerning about stepping positions and times in the laboratory using video set on July, 1984, It was found that the irregular movements of walking crabs in stepping positions and patterns were appeared on the nettings due to the absence of mechanical contact in spite of neural control of compensating, while on the flat surface evolved systematic leg movements. The mean stride length and walking velocity, which were increased with the carapace width on the flat board, as well as the step period and forward by backward stroke time were greater than those values on the netting, not associated with the carapace or the mesh size. Also, the step period and the Phase difference on the nettings revealed larger fluctuation than on the flat board. The joint angles of the walking legs, on the nettings in meropodite-carporodite and thorax-meropodite, which joint was varied especially up to below horizon because of the falling legs through the netting twine, were virtually wider than those on the flat substrate.

  • PDF

Fabrication Characteristics of Slag Fiber by 4 Wheel System (4휠 시스템을 이용한 슬래그 섬유의 제조)

  • Song, Yeong-Hwan;Seong, Hwan-Goo;Park, Soo-Han;Wang, Xiaosong;Hur, Bo-Young
    • Journal of Korea Foundry Society
    • /
    • v.26 no.5
    • /
    • pp.222-226
    • /
    • 2006
  • Steel making slag has gained a considerable attraction as one candidate of eco-materials in research fields for recycling resources. Thus, many researches have been performed but were limited to development of substitute for cement being used in the construction field. A little research work also has been done on development of higher value-added materials, including heat resistant and sound absorbing materials. For this reason, the present study were focused on macrostructure characterization of fabricated slag fibers which are applicable to heat resistant materials. The slag fibers were fabricated through a modified melt extraction method. The processing variables employed were the wheel speed and molten slag temperature. The synthesized fibers were characterized by optical microscope and scanning electron microscopy. It was found that the wheel speed of 1400 rpm generated better quality of mineral fibers in terms of the relative amount of shot, diameter and length. This was attributed to the relative extent of contact width between the flowing melt and the rotating wheel. The thickness of the slag fibers also were decreased with increasing the slag melt temperature due mainly to significant decrease in the viscosity of the slag melt. In addition, the lower melt temperature caused an increase in number of shots plus the mineral fibers.

Introduction of Bong Chuna Manual Therapy (봉 추나요법의 개요)

  • Oh, Won-Kyo;Shin, Byung-Cheul
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.2 no.1
    • /
    • pp.99-114
    • /
    • 2007
  • Objectives : The purpose of this study was to introduce the Chuna Manual Therapy (CMT) using Bong (a type of stick which is called 'bong') as a part of Oriental Medicine. Methods : We searched several traditional methods of CMT using Bong, either individual contact to specialist of CMT using Bong or referred to publications, and summarized briefly for introduction. Authors also made a comparative study between existing CMT and CMT using the bong. Results & Conclusions : The indications of Bong CMT are regarded as acute or chronic pain syndrome, whiplash associated disorders, facet syndrome, vertebral misalignment, chronic fatigue syndrome, obesity and also lower extremity length difference caused by malalignment of vertebrae and pelvic bone. The Meridian Muscle Therapy by pressing down using the Bong can be carried out on the imbalances of the muscle by shortening and lengthening contraction. CMT with Bong is considered more effective than other existing CMT in terms of effectiveness. In the case of pelvic correction which needs a tremendous amount of force, it can reduce the force required effectively. This fact can be inferred by the theory of composition and decomposition of force during the transmission of power. We can perform Bong CMT feeling less fatigued subsequently than general CMT. Pressing down with flexed fingers to grip bong acts on the contraction of flexor digiti and extensor digiti muscle, this protects the $doctor^{\circ}{\emptyset}s$ wrist joints from injury. The bong which acts as a tool between the doctor and the patient, while being given treatment, absorbs and spreads out the direct impact from the patient to the doctor. CMT with Bong is able to apply to both existing massage therapies with the hand. The bong appliance can be used in all applications, particularly, but not limited to; Orthopedic and Manual Correction Therapy, Meridian Muscle Pressing, Exercise Therapy, and Meridian Point Manual Pressing Therapy. CMT with Bong belongs to the category of oriental rehabilitation and Chuna manual medicine.

  • PDF

Thermal Deformation Measurement Spherical Glasses Lens Using ESPI (ESPI를 이용한 안경용 렌즈의 열변형 측정)

  • Kim, Koung-Suk;Jang, Ho-Sub;Kim, Hyun-Min;Yang, Seung-Pill
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.2
    • /
    • pp.137-143
    • /
    • 2008
  • The spherical glasses lenses are typically classified into two groups such as (+) diopter lens and (-) diopter lens by the refractive power index. The thermal deformation of a lens is occurred by external heat source and is changed respected to the diopter of a lens. In this paper, the thermal deformation of spherical glasses lenses were quantitatively measured by using ESPI (electronic speckle pattern interferometry) which has an advantage that the non-contact, non-destructive and precise deformation measurement is available due to the coherency characteristic. The temperature changes were measured by IR camera. It makes experiments over 14 types of the plastic glasses lenses. From the results, it was confirmed that the larger diopter lens showed the less thermal deformation in case of the (+) diopter lens. On the other hand, the thermal deformation of the (-) diopter lens was measured with uniform pattern when the same temperature changes were applied. Also, it was found that the thermnal deformation of the (+) diopter lens is less than that of the (-) diopter lens. Therefore, it is expected that when the thermal deformation is occurred to the various types of the lens, the variation of the focal length caused by the thermal distortion of a lens would be measured quantitatively.

Design of a Transformable Track Mechanism for Wall Climbing Robots (변형 트랙 메커니즘을 이용한 등반로봇 설계)

  • Lee, Gi-Uk;Seo, Kun-Chan;Kim, Hwang;Kim, Sun-Ho;Jeon, Dong-Su;Kim, Hong-Seok;Kim, Jong-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.2
    • /
    • pp.178-184
    • /
    • 2012
  • This paper presents a transformable track mechanism for wall climbing robots. The proposed mechanism allows a wall climbing robot to go over obstacles by transforming the track shape, and also increases contact area between track and wall surface for safe attachment. The track mechanism is realized using a timing belt track with one driving actuator. The inner frame of the track consists of serially connected 5R-joints and 1P-joint, and all joints of the inner frame are passively operated by springs, so the mechanism does not require any actuators and complex control algorithms to change its shape. Static analysis is carried out to determine design parameters which enable $90^{\circ}$ wall-to-wall transition and driving over projected obstacles on wall surfaces. A Prototype is manufactured using the transformable track on which polymer magnets are installed for adhesion force. The size of the prototype is $628mm{\times}200mm{\times}150mm$ ($Length{\times}Width{\times}Height$) and weight is 4kgf. Experiments are performed to verify its climbing capability focusing on $90^{\circ}$ wall to wall transition and driving over projected obstacle.