• 제목/요약/키워드: contact discharge

검색결과 269건 처리시간 0.024초

밀착형 선형 영상감지소자를 위한 a-Si:H막의 특성 (Characteristics of a-Si:H Films for Contact-type Linear Image Sensor)

  • 오상광;박욱동;김기완
    • 전자공학회논문지A
    • /
    • 제28A권11호
    • /
    • pp.894-901
    • /
    • 1991
  • Contact-type linear image sensors have been fabricated by means of RF glow discharge decomposition method of silane and hydrogen mixtures. The dependences of the electrical and optical properties of these sensor on thickness, RF power, substrate temperature and ambient gas pressure have been investigated. the ITO/i-a-Si:H/Al structure film shows photosensitivity of 0.85 and photocurrent to dark current ratio ($I_{ph}/I_{d}$) of 150 at 5V bias voltage under 200${\mu}W/cm^[2}$ red light intensity. Under 200${\mu}W/cm^[2}$ green light intensity, the ratio is 100. In order to investigate photocarrier transport mechanism and to obtain ${\mu}{\gamma}$ product we have measured the I-V characteristics of these sensors favricated with several different deposition parameters under various light sources. The linear inage sensor for document reading has been operated under reverse bias condition with green light source, resulting in ${\mu}{\gamma}$ product of about 1.5$[\times}10^{-9}cm^{2}$/V.

  • PDF

전기저항 용접 시 발생하는 지그의 비정상 마모현상 원인 분석 (Investigation of Abnormal Wear of Jig in Electric Resistance Welding)

  • 김선호;조행득
    • 한국기계가공학회지
    • /
    • 제14권1호
    • /
    • pp.51-56
    • /
    • 2015
  • This paper presents an investigation of abnormal wear of a contact jig between a nail and a nail fixture in electric resistance welding. To perform an analysis on the abnormal wear phenomenon, several methods are provided. Based on the theory of electric resistance welding, are analyzed. Using microscopic analysis, surface craters are observed. In the measurement of the electric current flow in the nail fixture, the current flow distribution is measured. From several analyses, the cause of abnormal wear in the contact jig is measured using the electric discharge of high current density at the inflow point of the electric supply to the nail fixture. An alternative shape for normal wear is proposed.

전해 프로세스에 의한 초미세 펀치의 제작 (Fabrication of Ultrathin Punch by Electrochemical Process)

  • 임형준;임영모;김수현;곽윤근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.792-796
    • /
    • 2000
  • With the development of micro machining, it becomes an important part to fabricate an electrode which has tens of ${\mu}m$ or less. There are two methods to get a narrow hole; non-contact type such as EDM(Electro-discharge machining) and contact type such as punching. A punch which has a tapered shape with a cylindrical tip is fabricated in this paper. To make this punch, a method which was used to fabricate a cylindrical shape by electrochemical process was applied. The control factors for the shape and their limits are verified through an experiment.

  • PDF

플루오르 화합물을 플라즈마 처리한 PET 직물의 표면특성 (Surface Property of PET Fabric Treated with $CF_4$ Plasma and $C_2F_6$ Plasma)

  • 김태년;모상영
    • 한국염색가공학회지
    • /
    • 제11권1호
    • /
    • pp.25-33
    • /
    • 1999
  • PET fabric was grafted with $CF_4$ or $C_2F_6$ plasmas generated by glow discharge. The water repellency of plasma-treated fabrics were evaluated with contact angle meter. The change in surface morphologies was observed by SEM, and the change of surface chemical characteristics were analyzed by FT-IR, ESCA and microchemical analysis technique. The results obtained are as follows : 1) The contact angle of plasma-treated fabric was over $150^\circ{C}$. 2) It was observed by SEM that the surface of treated substrate was over coated with thin film formed by the fluorocarbon plasma treatment. 3) According to ESCA analysis, there were prevailing -CHF-, $-CF_2$- and a little $-CF_3$ components on fluorocarbon plasma treated substrate. -CHF- and $-CF_2$- components were reduced by washing, and $-CF_2$- component was recovered by heat treatment. 4) In consideration of quantitative analysis of fluorine and F/C ratio by ESCA, we found that fluorination reached to the inner of substrate.

  • PDF

다공성 패드를 갖는 챔버의 배열에 따른 공기 부상 테이블의 비접촉 부상 수준에 대한 연구 (Non-Contact Level on Air Levitation Table with Porous Chamber Array)

  • 김준현;정영석;이태걸;김태훈;정효재
    • 한국생산제조학회지
    • /
    • 제22권6호
    • /
    • pp.913-920
    • /
    • 2013
  • This paper presents an applicable basic design that can configure non-contact levitation table for conveying a large sheet of glass. The suggested air levitation table consists of a series of air chambers with porous pads and fans as the conveyor system. The air supply chambers are arrayed to supply an adequately strong upward airflow for supporting the glass. Levitation is controlled by the size and discharge velocity, of the chamber arrays, as well as the glass supporting height. After pre-evaluation of the glass rigidity and the filer functional performance, a one-way fluid structure interface (FSI) analysis is performed for predicting pressure and deflection working of the 8G glass in the transverse and longitudinal directions, respectively. After comparing calculated levels of flatness of the glass, it determines the chamber array for the linear non-contact conveying motion.

대기압 저온 플라즈마 처리에 의한 폴리이미드의 친수화 효과 (Hydrophilic Effect of the Polyimide by Atmospheric Low-temperature Plasma Treatment)

  • 조중희;강방권;김경수;최병규;김세훈;최원열
    • 한국전기전자재료학회논문지
    • /
    • 제18권2호
    • /
    • pp.148-152
    • /
    • 2005
  • Atmospheric low-temperature plasma was produced using dielectric barrier discharge (DBD) plate-type plasma reactor and high frequency of 13.56 Hz. The surfaces of polyimide films for insulating and packaging materials were treated by the atmospheric low-temperature plasma. The contact angle of 67$^{\circ}$ was observed before the plasma treatment. The contact angle was decreased with deceasing the velocity of plasma treatment. In case of oxygen content of 0.2 %, electrode gap of 2 mm, the velocity of plasma treatment of 20 mm/sec, and input power of 400 W, the minimum contact angle of 13$^{\circ}$ was observed. The chemical characteristics of polyimide film after the plama treatment were investigated using X-ray photoelectron spectroscopy (XPS), and new carboxyl group bond was observed. The surfaces of polyimide films were changed into hydrophilic by the atmospheric low-temperature plasma. The polyimide films having hydrophilic surface will be very useful as a packaging and insulating materials in electronic devices.

진공 저온 플라즈마와 대기압 코로나 방전가공 PET 직물의 물리화학적 특성 (The Physicochemical Characteristics of PET Fabrics Treated with Low Temperature Glow Plasma and Atmospheric Corona Discharge)

  • 마재혁;양진영;구강;양현아;박영미
    • 한국염색가공학회지
    • /
    • 제26권3호
    • /
    • pp.201-208
    • /
    • 2014
  • The high value-added functionality for synthetic fiber can be considered through a plasma enhanced treatment. In this study, PET(Polyethyleneterephthalate) was treated with a glow plasma and corona treatment. Surface characteristics of treated fabric were investigated using electron scanning microscopy(SEM), contact angle, X-ray photoelectron spectroscopy(XPS), tensile and adhesion strength. It was found that the contact angle showed $85.5^{\circ}$ for untreated fabric, $0^{\circ}$ for plasma and corona treatment at the condition of 200W for 7min. By XPS analysis, atomic ratio of O 1s/C 1s was increased from 0.27 to 0.43 by glow plasma and 0.27 to 0.41 by corona treatment at 200W for 7min, respectively. Glow plasma and corona treatment did not significantly change the tensile strength of PET fabric. Adhesion strength showed a substantial enhancement for the surface treated with the glow plasma, while corona treatment was adversely affected.

대기중의 이산화탄소가 공기-아연전지에 미치는 영향 (Effect of Carbon Dioxide in the Air on Zinc-air Cell)

  • 김남인;박기홍;최용국;이우태
    • 공업화학
    • /
    • 제10권2호
    • /
    • pp.177-182
    • /
    • 1999
  • 대기중의 이산화탄소가 공기-아연전지에 미치는 영향을 검토하기 위하여 수산화칼륨 수용성 전해액을 공기와 접촉시킨 다음 시간의 경과에 따라 전해액중의 탄산칼륨 농도를 분석하여 전지 용량과의 관계를 규명하고자 하였다. 전해액은 공기와 접촉하는 시간이 경과함에 따라 대기중의 이산화탄소 흡수로 인하여 탄산칼륨의 농도가 증가하였으나 이에 비례하여 전지의 용량은 선형적으로 감소하였다. 이산화탄소의 흡수반응속도는 소수성 막의 세공크기가 주 인자로 작용하였으며, 세공크기를 조절한 소수성 막을 사용한 결과 이산화탄소 흡수로 인한 전지용량 열화현상을 현저히 감소시킬 수 있었다.

  • PDF

와이어 방전가공을 이용한 상어 표피 모사 리블렛 표면 제작 (Fabrication of a Micro-riblet Shark Skin-like Surface using a WEDM Process)

  • 박영환;김태완
    • Tribology and Lubricants
    • /
    • 제32권6호
    • /
    • pp.201-206
    • /
    • 2016
  • In this study, we attempt to produce a semi-elliptical riblet with a shark skin-like surface using wire electrical discharge machining (WEDM) and micro molding techniques. Our design for the production of the semi-elliptical mold includes an electrode, a winding roller, and a guide on the WEDM system. A replication mold with negative riblets is machined using WEDM, and a shark skin inspired surface with positive riblets is fabricated using a micro molding technique. For a comparison with the original shark skin, a shark skin replica is also produced using the micro molding technique directly from a shark skin template. Droplet contact angles on a flat surface, the shark skin replica, and the epoxy resin-based micro riblet shark skin-like surface are evaluated. The effect of a Teflon coating on the contact angles for the three different surfaces is also investigated. The results show the micro riblet with a shark skin-like surface has a similar contact angle as the shark skin replica, which means that the simplified riblet shark skin surface strongly influences the performance of wettability. This study confirms the effectiveness of using the WEDM method to prepare hydrophobic surfaces with diverse surface patterns.

아르곤 저온 플라즈마 처리에 의한 CTA 필름의 접착성 연구 (A Study on Adhesive Properties of Cellulose Triacetate Film by Argon Low Temperature Plasma Treatment)

  • 구강;박영미
    • 한국염색가공학회지
    • /
    • 제16권5호
    • /
    • pp.28-34
    • /
    • 2004
  • The polarizing film application exploits the unique physicochemical properties between PVA(Poly vinyl alcohol) film and CTA(Cellulose triacetate) film. However, hardly any research was aimed at improving the adhesion characteristics of the CTA film by radio frequency(RF) plasma treatment at argon(Ar) gaseous state. In this report, we deal with surface treatment technology for protective CTA film developed specifically for high adhesion applications. After Ar plasma, surface of the films is analyzed by atomic force microscopy(AFM), roughness parameter and peel strength. Furthermore, the wetting properties of the CTA film were studied by contact angle analysis. Results obtained for CTA films treated with a glow discharge showed that this technique is sensitive to newly created physical functions. The roughness and peel strength value increased with an increase in treatment time for initial treatment, but showed decreasing trend for continuous treatment time. The result of contact angle measurement refer that the hydrophilicity of surface was increased. AFM studies indicated that no considerable change of surface morphology occurred up to 3 minutes of treatment time, but a considerable uneven of surface structure resulted from treating time after 5 minutes.