• Title/Summary/Keyword: contact area

Search Result 1,937, Processing Time 0.03 seconds

Effect of Surface Film and Surface Roughness on Contact Resistance (표면막과 표면거칠기가 접촉 저항에 미치는 영향)

  • Lee, HyeonCheol;Lee, Bora;Yu, Younghun;Cho, Youngjoo
    • Tribology and Lubricants
    • /
    • v.35 no.1
    • /
    • pp.16-23
    • /
    • 2019
  • In this study, we aim to analyze the effects of both contact layer properties and surface roughness on contact resistance. The contact has a great influence on performance in terms of electrical conduction and heat transfer. The two biggest factors determining contact resistance are the presence of surface roughness and the surface layer. For this reason we calculated the contact resistance by considering both factors simultaneously. The model of this study to calculate contact resistance is as follows. First, the three representative surface parameters for the GW model are obtained by Nayak's random process. Then, the apparent contact area, real contact area, and contact number of asperities are calculated using the GW model with the surface parameters. The contact resistance of a single surface layer is calculated using Mikic's constriction equation. The total contact resistance is approximated by the parallel connection between the same asperity contact resistances. The results of this study are as follows. The appropriate thickness with reduction effect for contact resistance is determined according to the difference in conductivity between the base layer and surface layer. It was confirmed that the standard deviation of surface roughness has the greatest influence on surface roughness parameters. The results of this study will be useful for selecting the surface material and surface roughness when the design considering the contact resistance is needed.

An analysis on the factors responsible for relative position of interproximal papilla in healthy subjects

  • Kim, Joo-Hee;Cho, Yun-Jung;Lee, Ju-Youn;Kim, Sung-Jo;Choi, Jeom-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.4
    • /
    • pp.160-167
    • /
    • 2013
  • Purpose: This study examined the factors that can be associated with the appearance of the interproximal papilla. Methods: One hundred and forty-seven healthy interproximal papillae between the maxillary central incisors were examined. For each subject, a digital photograph and periapical radiograph of the interdental embrasure were taken using a 1-mm grid metal piece. The following parameters were recorded: the amount of recession of the interproximal papilla, contact point-bone crest distance, contact point-cemento-enamel junction (CEJ) distance, CEJ-bone crest distance, inter-radicular distance, tooth shape, embrasure space size, interproximal contact area, gingival biotype, papilla height, and papilla tip form. Results: The amount of recession of the interproximal papilla was associated with the following: 1) increase in contact point-bone crest, contact point-CEJ, and CEJ-bone crest distance; 2) increase in the inter-radicular distance; 3) triangular tooth shape; 4) decrease in the interproximal contact area length; 5) increase in the embrasure space size; and 6) flat papilla tip form. On the other hand, the amount of gingival recession was not associated with the gingival biotype or papilla height. In the triangular tooth shape, the contact point-bone crest distance and inter-radicular distance were longer, the interproximal contact area length was shorter, and the embrasure space size was larger. The papilla tip form became flatter with increasing inter-radicular distance and CEJ-bone crest distance. Conclusions: The relative position of the interproximal papilla in healthy subjects was associated with the multiple factors and each factor was related to the others. A triangular tooth shape carries a higher risk of recession of the interproximal papilla because the proximal contact point is positioned more incisally and the bone crest is positioned more apically. This results in an increase in recession of the interproximal papilla and flat papilla tip form.

Kinetic Analysis of Foot Balance and Gait Patterns in Patients with Adult Spinal Disease (성인 척추질환자의 발균형 및 보행형태에 대한 운동역학적 분석)

  • Park, Jae Soung;Lee, Joong Sook
    • Korean Journal of Applied Biomechanics
    • /
    • v.29 no.1
    • /
    • pp.23-32
    • /
    • 2019
  • Objective: The aim of this study was to provide kinematic data on the characteristics of spinal disease patients by comparing and analyzing kinematic variables related to foot balance and gait pattern of spinal disease. Method: The subjects of the study included 40 adult men and 60 adult women who visited the hospital in Busan. Patients who were diagnosed with spinal disease by a physician through X-ray examination were selected as subjects for the diagnosis of vertebral disc herniation, spinal stenosis, spinal disease diagnosed with spinal disease and the general public. Left and right foot pressure and contact area were checked by Gaitview pro meter. X-ray photographs were taken with a Zen-2090 mobile fluoroscopy under physicians' direct participation. One-way ANOVA was performed to compare the differences between the kinematic variables and post-hoc was performed by the Duncan method. Results: The difference in contact area between the left foot and the right foot was $115.30{\pm}14.15cm^2$ in the left side and $124.25{\pm}13.65cm^2$ in the left side in the spinal disease patients. The difference in pressure between the left and right side of the spinal disease patients was wider than that of the general people. Especially, the right side of the spinal disease patients showed a larger area of left foot contact than the general population. Conclusion: Spinal disease patients have wider contact area of the left foot than those of the general population. In the case of right spinal disease, the left foot support area is widened due to pain. In the gait, women showed slightly more posterior body center than men, and the upper body muscle imbalance and immobilization due to the spinal disease caused imbalance of the muscles moving to the lower limb, It was analyzed to inhibit movement.

Evaluation of the proximal contact and comparison of methods for measuring in normal dentition (건강한 자연치열에서 인접면 접촉의 평가 및 측정방법에 따른 비교분석)

  • Ji-Eun Kim;Cheong-Hee Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.198-203
    • /
    • 2023
  • Purpose. The aim of this study was to evaluate the proximal contact with a dental floss compared to a celluloid strip and a metal strip in normal dental arch and investigate what the most effective method for measuring is. Materials and methods. The subjects of this study was consisted with 20 healthy adults (10 males and 10 females) who had normal dentition. A dentist with more than 5 years of clinical experience evaluated the proximal contacts using a dental floss method, a celluloid strip method, and a metal strip method. Statistical analysis were performed by the use of Mann-Whitney U test. A P-value < .05 was considered statistically significant in all analysis. In addition, in the evaluation of proximal contact using a dental floss, the measurement of proximal contact using a celluloid strip and a metal strip was compared. Results. 80 % of all proximal contact was proper. Proper proximal contact was observed at the posterior area compared to the anterior area (P < .05). And male had proper proximal contact at the anterior area, female had proper proximal contact at the posterior area (P < .05). The consistency analysis between the results of the celluloid strip and the metal strip experiment on the results obtained from the floss using the consistency scale Kappa index shows that using celluloid strip is more advantageous than using the metal strip. Conclusion. Only 80% of all proximal contact was proper. Using celluloid strips with various thickness for evaluating of proximal contact is considered to be helpful for accurate measuring of proximal contact.

Three Dimensional Visualization of Contact Region for a Protein Complex (단백질 복합체를 위한 접촉 영역의 3차원 가시화)

  • Kang, Beom Sik;Kim, Ku-Jin;Kim, Yukyeong
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.2 no.12
    • /
    • pp.899-902
    • /
    • 2013
  • In this paper, we present a method to visualize the contact region between two molecules in a protein complex in a threedimensional space. The contact region of two molecules shows compatibility in geometric aspects. Usually, the computation of the area of contact region has been used to show the strength of compatibility. The numerical value and simple drawing of contact region would be useful for comparing the relative strength of different contacts, but it is not appropriate for analysing the geometric characteristics of the contact region. In this paper, we present a method to show the compatibility between two molecules by visualizing the distance information between them.

The Effects of Surface Energy and Roughness on Adhesion Force (표면에너지와 거칠기가 응착력에 미치는 영향)

  • Rha, Jong-Joo;Kwon, Sik-Cheol;Jeong, Yong-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.11 s.254
    • /
    • pp.1335-1347
    • /
    • 2006
  • Surface energies calculated from measured contact angles between several solutions and test samples, such as Si wafer, $Al_2O_3$, $SiO_2$, PTFE(Polytertrafluoroethylene), and DLC(Diamond Like Carbon) films, based on geometric mean method and Lewis acid base method. In order to relate roughness to adhesion force, surface roughness of test samples were scanned large area and small by AFM(Atomic Force Microscopy). Roughness was representative of test samples in large scan area and comparable with AFM tip radius in small scan area. Adhesion forces between AFM tip and test samples were matched well with order of roughness rather then surface energy. When AFM tips having different radius were used to measure adhesion force on DLCI film, sharper AFM tip was, smaller adhesion force was measured. Therefore contact area was more important factor to determine adhesion force.

Influence of Flux Density of Electric Leakage Area by Inundation (침수에 의한 누전지역의 자속밀도 영향)

  • Choi, Woon-Shik;Kim, Tag-Yong;Kim, Jin-Sa
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.6
    • /
    • pp.1109-1113
    • /
    • 2010
  • Recently, important for the safety has been increasing together economic developments. The leakage only is measured by the voltage difference. This method is a way to contact the electric leakage area. It can cause electric shock at users. We propose a non-contact method to detect a short circuit in this paper. We investigate magnetic field at electric leakage area to present non-contact method. Simulated environment created a short circuit in the flooded areas. Voltage is supplied 50, 150 and 200[V]. Magnetic field was measured at 0, 5 and 10[cm]. Magnetic flux was reduced about $0.4[{\mu}T/cm]$ depending on the distance changes in the steady region. But we confirmed that magnetic flux is measured the same value depending on the distance changes in the electric leakage area.

Computer Modeling of Hot Spot Phenomena in Ventilated Disk Brake Rubbing Surface

  • Kim, Chung-Kyun;Cho, Seung-Hyun;Ko, Young-Bae
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.229-230
    • /
    • 2002
  • This paper presents the hot spot behaviors on the rubbing surface of ventilated disk brake by using finite element method. The depth of asperities on the rubbing surface is usually $2-3\;{\mu}m$ so the real contact area is microscopically. Non-uniform contacts between the disk and the pads lead to high local temperatures, which may cause the material degradation, and develops hot spots, thermal cracking, and brake system failures at the end. High contact asperity flash temperatures in rubbing systems, which is strongly related to the hot spot. It was generally known that high temperature over about $700^{\circ}C$ may form martensite on the cast iron which is material for automotive disk brakes. In this paper, the contact stress, temperature distribution and strain have been presented for the specific asperities of real contact area microscopically by using coupled thermal-mechanical analysis technique.

  • PDF

Development of the non contact tongue moisture measuring device (비접촉식 설면 습윤도 측정 기구의 개발)

  • Kim, Dae-Bok;Park, Yu-Gyung;Kim, Ki-Wang
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.14 no.2
    • /
    • pp.67-74
    • /
    • 2010
  • Objectives: Tongue moisture is one of major features in tongue diagnosis of Oriental Medicine. But with regard to the methods to qualify the tongue moisture level, there have been no adequate modalities to satisfy clinicians' needs. So we developed an novel device and method to quantify the tongue moisture level without contact. Methods and Materials: Ratio of saturated area to total tongue area in the image captured with a spot light at various angles was calculated. We regarded that ratio represented the moisture of tongue surface. To evaluate the performance of suggested method, we observed the correlation between conventional contact method and our method with 19 healthy subjects. Results: With comparison to conventional contact method (Schirmer test), the suggested method showed good correlation (R = 0.8602, R2 = 0.7399). Conclusion: This Method could be a convenient and robust method to evaluate tongue moisture.

Optimized Sealing Profile Design of Mechanical Face Seals for a Hydro-power Turbine (소수력 터빈용 기계평면시일의 최적형상설계에 관한 연구)

  • Kim, Chung-Kyun;Kim, Jung-Il;Sihn, Ihn-Cheol;Lim, Kwang-Hyeon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.499-502
    • /
    • 2006
  • This paper presents computed results of FEM analysis on the tribological contact behaviors of a primary sealing components of mechanical face seals for a small hydro-power turbine. The FEM computed results present that the contact area between seal rings and seal seats is very important for a good tribological performance such as low friction heating, low wear, high contact normal stress in a primary seal ing components. Based on the FEM computation, model III in which has a small sealing contact area shows low dilatation of primary sealing components, and high contact stress between a seal ring and a 1)seal seat.

  • PDF