• Title/Summary/Keyword: consumption efficiency

Search Result 2,997, Processing Time 0.029 seconds

Residential Solar Cell System by driving of High Efficiency Inverter

  • Kwak Dong-Kurl;Lee Hyun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.687-691
    • /
    • 2001
  • With today's global environmental and energy problems, high expectations exist for solar power generation to reduce carbon dioxide generated by the consumption of fossil fuels. On the other hand, power consumption in residential homes is increasing every year. Among the many household appliances, the power demand for air conditioners increases dramatically during the summer, particularly in the afternoons. As this pattern closely matches the output pattern of solar cells, it should be possible to combine a photovoltaic array with an air conditioner to decrease the energy consumption within the home. We have developed a residential solar-powered air conditioner that operates through a combination of photovoltaic array and commercial power. In this paper, the configuration and specification of the residential solar-powered system are described to a novel high efficiency inverter using a ZVCS boost converter. And the performance evaluations of the solar-powered air conditioner are examined by the analysis of a new tracking controller with a maximum power $P_{max}$ detection of solar cell.

  • PDF

A High-Efficiency Driver Design for Mobile Digital Audio Speakers (모바일용 디지털 오디오 스피커를 위한 고효율 드라이버 설계)

  • Kim, Yong-Serk;Rim, Min-Joon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.1
    • /
    • pp.19-26
    • /
    • 2011
  • In this paper, we designed Interpolation FIR(Finite Impulse Response) filter and 1-bit SDM(Sigma- Delta Modulator) for small digital audio speaker, which has low power consumption and high output characteristics. In order to achieve high linearity and low distortion performance of the systems, we adopt Type I Chevychev FIR filter which has equiripple characteristics in the pass band and proposed high efficient FIR filter structure. SDM is the most efficient modulation technique among the noise shaping techniques. In this paper, we implemented SDM using CIFB(Cascade of Intergrators, Feed-Back) which is generally used in DAC of small digital audio speakers. The proposed SDM structure can achieve high SNR, high-efficiency characteristics and low power consumption in mobile devices. Also considering manufacture of SoC(System on Chip), we performed simulation with Matlab and Verilog HDL to obtain optimal number of operational bits and verified a good experimental results.

Electrode Thickness Optimization at Full Color OLED and Analysis of Power Consumption

  • Park, Sung-Joon;Kim, Ok-Tae;Kim, Hee-Je
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.3
    • /
    • pp.106-110
    • /
    • 2004
  • The operating condition of the OLED (organic light-emitting diode) is very sensitive to electrode thickness properties. The electrode thickness is a significant issue in the construction of OLEDs because of its transparency, high conductivity and high efficiency as an injector into organic materials. We carried out a systematic study to optimize the electrode thickness conditions in Indiumtin oxide (ITO), Molybdenum (Mo) and Aluminum (Al). Further, we measured electrode thickness under standard conditions [ITO 1500$\AA$, Mo 2600$\AA$, Al 1500$\AA$]. We also evaluated power consumption. In addition, we analyzed substrate uniformity with IVL measurement results. From these results, it is known that the electrode thickness should be optimized in order to accomplish optimal power efficiency.

An Analysis on the Causal Relation Between Electricity Consumption and GDP by industries in KOREA (한국의 산업별 전력소비와 경제성장간 인과관계 분석)

  • Park, Min Hyug;Roh, Geon Ki;Lee, Seung Eun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.3
    • /
    • pp.39-45
    • /
    • 2016
  • In these days global energy policy is changed from "supply" to "demand". In this regards, there are needs to analysis on effect of policy such as energy efficiency strategy, electricity rates. This study examines the relationship between energy consumption reduced by new energy policy and GDP growth for each industrial sector for Korea from 1970 to 2013. With respect to the direction of causality, energy use of 1th industry like agriculture and mining leads to GDP growth. On the other hand, GDP growth of 2nd industry, manufacturing, leads to energy use. And there is bidirectional causality in 3rd industry, service sector. These findings imply that the government policies aimed at reducing electricity consumptions and increasing energy efficiency should be progressed cautiously depend on status of each industry condition.

A Study on the Major Contituent Components & the Effect of Efficiency Improvement for the BEMS (BEMS(Building Energy Management System) 구축을 위한 주요 구성요소와 건물에너지효율등급 개선효과에 관한 연구)

  • Son, Hag-Sig
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.1
    • /
    • pp.105-113
    • /
    • 2014
  • Currently, the energy consumption rate in buildings is approximately 28.5% of the total energy consumption in Korea. Therefore the amount of the consumption of petroleum resourses is at a worrying level of the blackout. The system of the amount of the Architectural Energy Efficiency Grade [AEEG] is in force by the government to apply the technologies of the Emissions Trading System and the Target Management System to mitigate the Green House Gases for buildings according to the climate change. On the account the mitigation of the Green House Gases and the reduction of the energy, from the view of maintenance and management, for the new and remodeling buildings should be under consideration. The author wants to present the possible ways how to improve the AEEG for the existing buildings by trying to establish the foundation of the BEMs, and by confirming the potential of the energy savings.

Performance Evaluation of a Crank-driven Compressor and Linear Compressor for a Household Refrigerator

  • Park, Minchan;Jung, Yoongho;Lee, Jaeyeol;Lee, Jaekeun;Ahn, Youngchull
    • Journal of Power System Engineering
    • /
    • v.21 no.5
    • /
    • pp.5-12
    • /
    • 2017
  • With the difficulties in increasing the efficiency of conventional crank-driven compressors due to mechanical loss, compressor manufacturers have investigated new kinds of compressor such as a free piston compressor mechanism. This study investigates the energy efficiency of two different types of compressor for a household refrigerator. One is the conventional crank-driven compressor, and the other one is a linear compressor. The energy efficiencies of these compressors are evaluated. Experimental results show that the linear compressor has 10% lower power consumption than the brushless direct-current (BLDC) reciprocating compressor. The linear compressor demonstrates excellent energy efficiency by reducing the friction loss. Furthermore, a motor efficiency exceeding 90% is achieved by using a linear oscillating mechanism with a moving magnet. Additionally, the compressor stroke to piston diameter ratio of the oscillating piston in the linear compressor can be adjusted in order to modulate the cooling capacity of the compressor for improved system efficiency.

Competition and Efficiency : Evidence from the Korean Electricity Market (경쟁이 효율성을 증가시키는가 : 전략산업 구조개편을 중심으로)

  • Kim, Dae-Wook
    • Environmental and Resource Economics Review
    • /
    • v.17 no.1
    • /
    • pp.23-49
    • /
    • 2008
  • In this paper, we estimate whether changes in the economic environment a firm operates in affects technical efficiency. Since efficiency gains can manifest themselves in a variety of ways, we estimate for efficiency gains on annual generating plants input demand for expenses and fuel use. We find that generating plants reduced their workers and costs respectively by 6.8% in 1999 and 37.9% in 2001. However, they didn't show any systematic caloric consumption changes facing various economic environmental shocks. These results suggest that restructuring brought efficiency gains by replacing regulated monopoly with a more competitive firms in the context of the Korean electricity market.

  • PDF

Evaluation of the Applicability of Livestock Wastewater Treatment using Boron-Doped Diamond (BDD) Electrodes (BDD 전극을 이용한 축산폐수 처리의 적용성 평가)

  • Hyun-Gu Kim;Dae-Hee Ahn
    • Journal of Environmental Science International
    • /
    • v.32 no.6
    • /
    • pp.465-475
    • /
    • 2023
  • In this study, we evaluated the treatment efficiency of livestock wastewater by altering the current density using boron-doped diamond (BDD) electrodes. As the current density was adjusted from 10 to 35 mA/cm2, the removal efficiency of organic matter increased from 22.2 to 71.5%. Similar to that of organic matter, the removal efficiency of color increased with increasing current density up to 85.7%, indicating a higher removal efficiency for color than that of organic matter. The removal efficiency of ammonia nitrogen increased from 14.6 to 53.3% as the current density increased, but it was lower than that of organic matter. In addition, the removal of organic matter, color, and ammonia nitrogen followed first-order reactions, according to the reaction rate analysis. The energy consumption ranged from 4.87 to 8.33 kWh/kg COD, and it was found that the organic matter removal efficiency was more efficient at high current densities. Based on various analyses, the optimal current density was 20 mA/cm2, and the corresponding energy consumption was 6.824 kWh/kg COD.

A Development of Test Method on the Energy Consumption Efficiency of Domestic Gas Boiler below 70 kW (70 kW 이하 가정용 가스보일러 에너지소비효율 실험방법 개발)

  • Park, Chanil;Kim, Laehyun
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.73-82
    • /
    • 2016
  • The energy consumption efficiency in a variety of operational test mode was considered for domestic gas boiler below 70 kW. The energy efficiency test carried out in the experimental conditions similar to the actual operation status was analyzed and compared with the current Korean efficiency test method. Four types of test modes for each boiler(Non-condensing and condensing boiler) were carried out in the condition of laboratory mode(full load, steady state) and actual operating mode. Futhermore divided into two operational status for each of these, it was applied by maximum gas consumption and consumer sales conditions. Test equipment has the function referred to gas boiler standards, such as KS or European standard EN. The equipment should be continuously measured and record the measuring factors which are the flow volume of gas and water, laboratory temperature, water flow volume for heating, return water volume after heating and quantity of the exhaust gases(CO, NO, $NO_2$). The experimental results were found that non-condensing boiler efficiency of laboratory mode is about 10% higher than that of actual mode. In case of condensing boiler, the efficiency of laboratory condition is about 20% higher than that of the actual using conditions. I suggest that the government will gradually take the efficiency test method considering the actual conditions.

Investigation on the Reduction Effect on Cooling Power Consumption and Operating Cost of Mist-spray Outdoor Units in Air Conditioner

  • Lee, Keon-ho;Cho, Dong-woo;Kim, Hyemi;Song, Young-hak
    • Architectural research
    • /
    • v.19 no.4
    • /
    • pp.101-108
    • /
    • 2017
  • The use of the air conditioner is increasing due to the rise of the outdoor temperature during summer, and the problems of the fire and the cooling performance deterioration are caused due to lack of maintenance of the outdoor unit. In particular, overall performance of cooling system and efficiency in outdoor units have been degraded due to an intake of high-temperature outdoor air thereby increasing cooling energy and operating cost. Thus, this study aimed to increase efficiency of outdoor units by evaporating and cooling intake air through mist spray at the intake port surface in the outdoor unit. The measurements results showed that total power consumption of misting outdoor unit compared to that of conventional outdoor units was reduced by 21% approximately, and total power consumption of the entire system including pump was reduced by 16.7%. In addition, the operating cost including water use was reduced by 13.5% approximately. In summary, if a mist-spray nozzle kit is installed in air-cooled outdoor units, the reduction in the usage of cooling energy and operating cost will be achieved without replacement of existing cooling systems or a large scale of repairs.