• Title/Summary/Keyword: construction waterproofing

Search Result 337, Processing Time 0.028 seconds

Evaluation on the Material Properties of Waterproof Concrete with Self-healing Admixture (자가치유형 구체방수 콘크리트의 기초물성 평가)

  • Jeon, Hong-Mim;Lee, Jong-Yun;Hong, Seok-Beom;Kim, Jin-Keun;Lee, Yong-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.415-416
    • /
    • 2009
  • Concrete with Self-healing Admixture provides waterproof protection by using a organic-inorganic chemical compound throughout the concrete. Using cement chemicals eliminate the need to use additional waterproofing, If crack is occurred, this system enhance self-healing ability to increase the structural safety. In this study, we investigate material properties to conclude mixture rate of concrete to apply a construction site.

  • PDF

Tension Strength and Expansion Property Analysis Research to Utillize Thermoplasticity Recycling Plastic to Single Play Waterproof System for Construction (열가소성 재활용수지를 건축용 단층방수시스템에 활용하기 위한 인장 및 신장 특성 분석 연구)

  • Park, Sung-Woo;Ko, Jin-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.89-94
    • /
    • 2011
  • In this research, among thermoplasticity plastic raw material that recycling is possible polyolefine(TPO) and polyvinyl chloride(PVC) as target recycling plan examine wish to. It is polyolefine(TPO) and polyvinyl chloride(PVC)) is mediocrity material that there are a lot of amount useds among plastic material and it is material that recycling is also activated most. Long term made first new regulation raw material, by-product raw material happened at process of production at second factory and third time to examine recycling plan of this material divides this as raw material that pass through process separation and pelet Tuesday and analyzed each special quality removing each removed waste after is used. Measure tension strength and ext. heightening gradually mixing proportion of refreshing resources on standard Sample manufactured as new raw material and application examined possibility availability to single fly system.

  • PDF

Analysis the influence of the exterior insulation deterioration and water leakage on the aging of concrete structure (건축 구조물 외단열 시스템의 열화 및 누수현상이 구조물 노후화에 미치는 영향 분석에 관한 연구 - 초고층 oo 아파트 외벽 누수 사례를 통하여 -)

  • Park, Yeun-Jin;Park, Jin-Sang;Seon, Yun-Suk;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.159-163
    • /
    • 2007
  • We studied the example of various side on effect the aging of exterior materials for concrete structure by analyzing the reason of water leakage in exist serviced skyscraper apartment. For this side, we would like to suggest the proper waterproofing materials and construction methods resulted in the mechanical performance test. So, it could be ensured the leakage safety for using residence facility and crowd utilization after repairing. It may maximize the durability for the concrete structure.

  • PDF

A Study on the Root-Resistance Performance of PET film Sheet applied by FRP Coating material (PET 필름 내근시트와 FRP 도막층이 일체화된 방수·방근층의 방근성능에 관한 연구)

  • Kwon, Young-Hwa;Park, Jin-Sang;Kim, Dong-Bum;Park, Wan-Goo;Kim, Byoung-Il;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.253-254
    • /
    • 2018
  • In the construction industry, a variety of Root-Resistance Waterproofing Sheets ar being developed and studied. However, defects still occur in the sheet. In this study, the performance of the navigation is studied by Root-Resistance. As a result of the test, no piercing or penetration marks were found by root in all the specimens.

  • PDF

Information Network Usage Plan for the Quality Control of Leakage Prevention (누수예방을 위한 품질확보 관련 정보공유시스템의 활용방안의 관한 연구)

  • Kang, Hyo-Jin;An, Ki-Won;Kim, Soo-Yeon;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.217-218
    • /
    • 2017
  • Residential apartment underground structures are being utilized for many purposes such as parking lots, community centers, fitness centers, etc. for efficient use of space. However, there are increasing problems of leakage due to various environmental and deterioration conditions. This paper proposes the development of an information network system which can serve as a base to provide solutions, alternatives and technical information for leakage prevention and effective design at the beginning of the construction stage.

  • PDF

Exposure Characteristics of Construction Painters to Organic Solvents

  • Park, Hyunhee;Park, Hae Dong;Jang, Jae-Kil
    • Safety and Health at Work
    • /
    • v.7 no.1
    • /
    • pp.63-71
    • /
    • 2016
  • Background: Construction painters have not been studied well in terms of their hazards exposure. The objective of this study was to evaluate the exposure levels of total volatile organic compounds (TVOCs) for painters in the construction industry. Methods: Activity-specific personal air samplings were carried out in three waterproofing activities [polyurethane (PU), asphalt, and cement mortar] and three painting activities (epoxy, oil based, and water based) by using organic-vapor-monitor passive-sampling devices. Gas chromatograph with flame ionization detector could be used for identifying and quantifying individual organic chemicals. The levels of TVOCs, by summing up 15 targeted substances, were expressed in exposure-index (EI) values. Results: As arithmetic means in the order of concentration levels, the EIs of TVOCs in waterproofing works were 10.77, 2.42, 1.78, 1.68, 0.47, 0.07, and none detected (ND) for indoor PU-primer task, outdoor PU-primer task, outdoor PU-resin task, indoor PU-resin task, asphalt-primer task, asphalt-adhesive task, and cement-mortar task, respectively. The highest EI for painting works was 5.61 for indoor epoxyprimer task, followed by indoor epoxy-resin task (2.03), outdoor oil-based-spray-paint task (1.65), outdoor water-based-paint task (0.66), and indoor oil-based-paint task (0.15). Assuming that the operations were carried out continuously for 8 hours without breaks and by using the arithmetic means of EIs for each of the 12 tasks in this study, 58.3% (7 out of 12) exceeded the exposure limit of 100% (EI > 1.0), while 8.3% (1 out of 12) was in 50e100% of exposure limit (0.5 > EI > 1.0), and 4 tasks out of 12 were located in less than 50% of the limit range (EI < 0.5). Conclusion: From this study, we recognized that construction painters are exposed to various solvents, including carcinogens and reproductive toxins, and the levels of TVOC concentration in many of the painting tasks exceeded the exposure limits. Construction workers need to be protected from chemical agents during their painting works by using personal protective devices and/or work practice measures. Additional studies should focus on the exposure assessment of other hazards for construction workers, in order to identify high-risk tasks and to improve hazardous work environments.

Improvement of Selection System of Waterproofing Methods for Concrete Structure (지하 콘크리트 구조물의 적정 방수공법 선정을 위한 평가시스템 제안에 관한 연구)

  • Oh, Sang-Keun;Kwak, Kyu-Sung;Choi, Sung-Min;Kwon, Shi-Won
    • Journal of the Korea Institute of Building Construction
    • /
    • v.7 no.1 s.23
    • /
    • pp.99-106
    • /
    • 2007
  • Water leakage could be caused deterioration of environmental conditions, user condition, reduction of life span and long term safety in underground concrete structure. Many materials and construction method to repair on these problems have been developed, however, it is not proper to successful repair or raise problem of increasing repair cost However, there are many limitations as practical appraisal methods due to different view of reliability for test methods. Because, it was not enough that the technical objectivity could be lack and also application of environmental condition is inadequate. In this paper, we suggest varied test methods divided to appraisal for property of matter, construction, manufacturing, specification and maintenance, friendly environmental condition. It could be more practical as a objective standard considering various angles. In summery, it should be subdivided and differentiated to accomplish proper application and to select proper materials and construction method for repair even if the synthetical condition is very complicated.

Linear Regression Analysis of Tensile Performance for the Polyurethane Coating Waterproofing Material Periodically Exposed to Chemical Degradation (회귀 분석을 통한 폴리우레탄 도막방수재의 장기 화학 열화조건에 따른 인장성능 변화 지표)

  • Ju, Hee-Jeong;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.5
    • /
    • pp.455-461
    • /
    • 2018
  • The purpose of this study is to evaluate the tensile strength performance of the polyurethane coating material used as the waterproofing material in concrete structures. A linear regression equation is proposed to establish a correlation on the tensile strength of polyurethane coating membrane against periodic exposure to chemical degradation. The polyurethane film membrane showed a minimum strength of 23% to a maximum of 38% when subjected to chemical degradation. The elongation rate showed a relation with the tensile strength deterioration rate of at least 15% to 22% at maximum, and the proposed regression equation could be used to predict the degree of performance change of the polyurethane coating membrane under chemical degradation condition.

A Fundamental Study for Development on Waterproof and Flame Retardant processing technology the Interior Wood of using Induced electricity heating Microwave (유전가열 마이크로파를 적용한 방수·방염 내장목재 개발을 위한 기초적 연구)

  • Park, Cheul-Woo;Heo, Jae-Won;Lim, Nam-Gi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.35-41
    • /
    • 2008
  • Qualitative enhancement of dwelling life has changing the recognition for the environment friendly wood which is being highlighted for its usage as an interior materials. This trend may prove the excellent performance of wood whose inherent characteristics has its comfortable, mild feeling of material, sound resistance and stabilities and the market of interior woods including floor, moulding and wooden panel as finishing interior materials is growing sustainably. However, since this materials is vulnerable to humidity and flame, waterproofing and flame retarding stability, an essential condition for interior materials, together with maintenance, are the main topics to be resolved. From the above-mentioned results, as a result of waterdrop contact angle, wood absorption volume and water content percentage test and the performance test of the processed materials after flame retardant, though there was some submerging time changes among types of woods for ensuring waterproofing performance improvement but as time passes, similar tendency was noticed to be formulated. As the submerging time is increased, so does the absorption volume and accordingly optimal level of range is judged to be drawn in order to ensure excellent performance, taking optimal economy into consideration. Therefore, it is considered that above-mentioned woods could be utilized for waterproof and flame retardant processed interior materials using uniform microwave and in order to put this technology into practical application, a research by way of diversified performance proving is required to be carried out.

  • PDF

Verification and Improvement of Structural Behavior Response Performance Evaluation Method for the Standard Establishment of Adhesive Composite Waterproofing Sheets (점착형 복합 방수시트의 표준(안)제정을 위한 구조물 거동대응성능 시험방법 개선 및 검증 평가 연구)

  • Kim, Soo-Yeon;Park, Jong-Sun;Oh, Sang-Keun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.4
    • /
    • pp.377-386
    • /
    • 2021
  • In April 2019, this study was enacted as a test method for the performance of waterproof layers in an environment where complex deterioration and structural behavior are simultaneously applied, but some existing standards were implemented to point out the errors of the method that should be supplemented. Thus, in establishing standards for (tentative) adhesive waterproofing sheets, field workability and quantification of test results were studied on the structural behavior response performance test methods included as test items. In addition, the performance evaluation of adhesive-type composite waterproof sheets was conducted based on the considered contents to review improvements such as applicability as an item of standard standards and field workability related problems.