• Title/Summary/Keyword: construction joints

Search Result 610, Processing Time 0.026 seconds

A Study on Behaviors of Prestressed Bridge Girders Made Continuous (연속화된 Prestress 거더교의 거동연구)

  • 구민세;최인식;김진헌
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.396-403
    • /
    • 2002
  • To eliminate deck joints, continuous span bridges are becoming an attractive option. Defferent continuty methods and construction sequences have different time-dependent effects on the behavior of the bridge system. This paper is carried out to evaluate the restraint moments generated at interior span of bridges constructed with full-span prestessed concrete bridge. Especially, effects of creep and shrinkage between ACI209-95 and Eurocode 2 are compared in this paper. Time-dependent effects in prestressed concrete bridges include creep and shrinkage of concrete. Creep due to prestress makes the girders camber up and cause positive restraint moments. The most significant effect of shrinkage in continuous bridges is the differential shrinkage that occurs because of the difference in type and age of girder and deck concrete. Differential shrinkage between the precast girder and the deck typically causes negative res03int moments.

  • PDF

A Study on the BIM-based Design for the Elements of Wooden Structure of Korean Traditional Buildings Through a Parametric Design Methodology (파라메트릭 디자인 방법론을 활용한 한옥 목구조부재의 BIM 설계 프로세스 연구)

  • Park, Jung-Dae
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.2
    • /
    • pp.104-113
    • /
    • 2011
  • With the rising social interest in the sustainable life, demands are growing for Hanok, as a viable alternative to modernized architecture of Western origin. However, even Hanok is gaining popularity among the general public, its design and construction are still a minor practice. Aiming to build an information system of Hanok, this research proposes a new design process for traditional architecture, utilizing a parametric design methodology. This process, based on the understanding of tectonic joints and spatial composition of our traditional architecture, defines a parametric relationship among the structural elements that compose Hanok. The research uses Gehry Technologies' Digital Project and Autodesk Revit Architecture to apply a concurrent parametric design methodology, approaching the project in both bottom-up and top-down to present a new design process for Hanok elements.

Cyclic and static behaviors of CFT modular bridge pier with enhanced bracings

  • Kim, Dongwook;Jeon, Chiho;Shim, Changsu
    • Steel and Composite Structures
    • /
    • v.20 no.6
    • /
    • pp.1221-1236
    • /
    • 2016
  • Modular structures consist of standardized modules and their connections. A modular bridge pier is proposed to accelerate bridge construction. Multiple concrete-filled steel tubes (CFTs) using commercial steel tubes were chosen as the main members. Buckling restrained bracings and enhanced connection details were designed to prevent premature low-cycle fatigue failure upon cyclic loading. The pier had a height of 7.95 m, widths of 2.5 m and 2.0 m along the strong and weak axis, respectively. Cyclic tests were performed on the modular pier to investigate structural performance. Test results showed that four CFT columns reached yielding without a premature failure of the bracing connections. The ultimate capacity of the modular pier was reasonably estimated based on the plastic-hinge-analysis concept. The modular CFT pier with enhanced bracing showed improved displacement ductility without premature failure at the welding joints.

The ultimate bearing capacity of rectangular tunnel lining assembled by composite segments: An experimental investigation

  • Liu, Xian;Hu, Xinyu;Guan, Linxing;Sun, Wei
    • Steel and Composite Structures
    • /
    • v.24 no.4
    • /
    • pp.481-497
    • /
    • 2017
  • In this paper, full-scale loading tests were performed on a rectangular segmental tunnel lining, which was assembled by steel composite segments, to investigate its load-bearing structural behavior and failure mechanism. The tests were also used to confirm the composite effect by adding concrete inside to satisfy the required performance under severe loading conditions. The design of the tested rectangular segmental lining and the loading scheme are also described to better understand the bearing capacity of this composite lining structure. It is found that the structural ultimate bearing capacity is governed by the bond capacity between steel plates and the tunnel segment. The failure of the strengthened lining is the consequence of local failure of the bond at waist joints. This led to a fast decrease of the overall stiffness and eventually a loss of the structural integrity.

Reliability Improvement Method of Weld Zone in Water Wall Tube for an Ultra Supercritical Coal Fired Boiler (초초임계압 석탄화력 보일러 수냉벽 수관의 용접신뢰성 향상방안)

  • Ahn, Jong-Seok;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.6 no.3
    • /
    • pp.53-61
    • /
    • 2010
  • This paper presents failure analysis on weld-joint of the waterwall tubes in USC boilers. Visual inspections were performed to find out the characteristics of the fracture. Additionally both microscopic characteristics and hardness test were carried out on failed tube samples. Failures seem to happen mainly because the welding process such as preheating and PWHT(post-weld heat treatment) was not conducted strictly. Thus, this paper has the purpose to describe the main cause of the poor welding process and to explain how to prevent similar failures in those weld-joints.

  • PDF

Life Prediction of High Pressure Hydraulic Hose Assemblies by the Impulse Test

  • KIM, Hyoung-Eui;LEE, Yong-Bum;Kwon, Young-Il
    • Corrosion Science and Technology
    • /
    • v.3 no.5
    • /
    • pp.209-215
    • /
    • 2004
  • Flexible hydraulic hose assembly that consists of hose and joints is used widely on various construction heavy equipments, agricultural machines, motor vehicles, and industrial heavy machines that require flexibility on hydraulic pipelines. It is classified by the maximum usage pressure which is determined by the winding layers of coiling steel wire and the inner diameter of the hoses. In this paper, we designed and performed an accelerated life test for assessing the reliability of a flexible hydraulic hose assembly. In the proposed accelerated life test, typical impulse pressure testing method is applied with the half omega flexing operation to simulate the practical flexing motion of the hose assembly.

Outrigger Systems for Tall Buildings in Korea

  • Chung, Kwangryang;Sunu, Wonil
    • International Journal of High-Rise Buildings
    • /
    • v.4 no.3
    • /
    • pp.209-217
    • /
    • 2015
  • Outrigger systems are highly efficient since they utilize the perimeter zone to resist lateral forces, similar to tubular systems. The entire structural weight can be reduced due to the system's significant lateral strength. Therefore, it is the most commonly selected structural system for tall and supertall buildings built in recent years. In this paper, issues regarding the differential shortening effect during construction of the outrigger system and the special joints used to solve these issues will be addressed. Additionally, the characteristics of wind and seismic loads in Korea will be briefly discussed. Lastly, buildings in Korea using an outrigger as their major structural system will be introduced and the structural role of the system will be analyzed.

Behaviour of continuous prestressed concrete beams with external tendons

  • Chan, K.H. Enoch;Au, Francis T.K.
    • Structural Engineering and Mechanics
    • /
    • v.55 no.6
    • /
    • pp.1099-1120
    • /
    • 2015
  • External prestressing has been applied to both new construction and retrofitting of existing reinforced and prestressed concrete structures. Continuous beams are preferred to simply supported beams because of economy, fewer movement joints and possible benefits from moment redistribution. However, this paper argues that continuous prestressed concrete beams with external unbonded tendons demonstrate different full-range behaviour compared to reinforced concrete (RC) beams. Applying the same design approach for RC to external prestressing may lead to design with a lower safety margin. To better understand the behaviour of continuous prestressed concrete beams with unbonded tendons, an experimental investigation is performed in which nine such specimens are tested to failure. The full-range behaviour is investigated with reference to moment-curvature relationship and moment redistribution. The amounts of moment redistribution measured in the experiments are compared with those allowed by BS 8110, EC2 and ACI 318. Design equations are also proposed to estimate the curvature ductility index of unbonded prestressed concrete beams.

Experimental study on rock-concrete joints under cyclically diametrical compression

  • Chang, Xu;Guo, Tengfei;Lu, Jianyou;Wang, Hui
    • Geomechanics and Engineering
    • /
    • v.17 no.6
    • /
    • pp.553-564
    • /
    • 2019
  • This paper presents experimental results of rock-concrete bi-material discs under cyclically diametrical compression. It was found that both specimens under cyclical and static loading failed in three typical modes: shear crack, tensile crack and a combined mode of shear and wing crack. The failure modes transited gradually from the shear crack to the tensile one by increasing the interface angle between the interface and the loading direction. The cycle number and peak load increased by increasing the interface angle. The number of cycles and peak load increased with the interface groove depth and groove width, however, decreased with increase in interface groove spacing. The concrete strength can contribute more to the cycle number and peak load for specimens with a higher interface angle. Compared with the discs under static loading, the cyclically loaded discs had a lower peak load but a larger deformation. Finally, the effects of interface angle, interface asperity and concrete strength on the fatigue strength were also discussed.

Application of Hybrid Structural System Using Coupled Vibration Control Structure and Seismic Isolated Structure in High-Rise Building

  • Nakajima, Shunsuke
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.3
    • /
    • pp.219-227
    • /
    • 2021
  • This building is a forty-eight story, 170 meters high multiple dwelling house with Dual Frame System (DFS), a coupled vibration system connecting two independent structures with hydraulic dampers. Generation of large deformation between two structures during earthquakes contributes to make the hydraulic dampers effective. To improve the aseismic performance more, this building adopts DFS hybrid system that consists of DFS and base isolation system. About typical floors, columns and beams are constructed with LRV precast concrete method that shorten the construction period greatly by integrating column-beam joints in column members.