시정수를 이용한 직류철도급전계통에서의 고장판단 및 고장점표정 알고리즘 (A Fault Detection and Location Algorithm Using a Time Constant for DC Railway Systems)

  • 양언필;강상희;권영진
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권10호
    • /
    • pp.563-570
    • /
    • 2003
  • When a fault occurs on railway feeders it is very important to detect the fault to protect trains and facilities. Because a DC railway system has low feeder voltage, The fault current can be smaller than the current of load starting. So it is important to discriminate between the small fault current and the load starting current. The load starting current increases step by step but the fault current increases at one time. So the type of $\Delta$I/ relay(50F) was developed using the different characteristics between the load starting current and the fault current. The load starting current increases step by step so the time constant of each step is much smaller than that of the fault current. First, to detect faults in DC railway systems, an algorithm using the time constant calculated by the method of least squares is presented in this paper. If a fault occurs on DC railway systems it is necessary to find a fault location to repair the faulted system as soon as possible. The second aim of the paper is to calculate the accurate fault location using Kirchhoff's voltage law.

LED 조명용 정전류 SMPS 개발 (Development of constant current SMPS for LED Lighting)

  • 신현용
    • 한국전자통신학회논문지
    • /
    • 제10권1호
    • /
    • pp.111-116
    • /
    • 2015
  • 본 연구에서는 실내조명을 위한 LED 조명용 정전류 컨버터를 설계하고 제작된 SMPS의 전기적 특성을 측정하였다. 출력전류가 300mA 일 때 최대 85%의 효율을 나타내었으며 100~400mA의 범위에서는 70% 이상의 효율을 나타내었다. 또한 0~250mV의 제어신호를 이용하여 디밍레벨 0~100%의 범위를 모두 제어할 수 있었다.

용융아연도금 강판 저항 점 용접 시 정전류 및 적응제어 적용에 따른 연속타점 특성 평가 및 고찰 (A comparative study of constant current control and adaptive control on electrode life time for resistance spot welding of galvanized steels)

  • 서정철;최일동;손홍래;지창욱;김치호;서성부;서진석;박영도
    • Journal of Welding and Joining
    • /
    • 제33권2호
    • /
    • pp.47-55
    • /
    • 2015
  • With using adaptive control of the resistance spot welding machine, the advantage on electrode life time for galvanized steels has been addressed. This study was aimed to evaluate the electrode life time of galvanized steels with applying the constant current control and the adaptive control resistance spot welding process for a comparison purpose. The growth in diameter of electrode face was similar for both the constant current and the adaptive control up to 2000 welds. The button diameter was decreased with weld numbers, however, sudden increase in button diameter with use of the adaptive control after 1500 welds was observed. The peak load was continuously decreased with increasing number of welds for both the constant current and the adaptive control. The current compensation during a weld was observed with using the adaptive control after 1800 welds since the ${\beta}$-peak on dynamic resistance curve was detected at later weld time. The current compensation with adaptive control during resistance spot welding enhanced the nugget diameter at the faying interface of steel sheets and improved the penetration to thinner steel sheet.

Self Field Effect Analysis of Bi-2223 Tape-Stacked-Cable With Constant Current Density Assumption

  • Nah, Wansoo;Joo, Jinnho
    • Transactions on Electrical and Electronic Materials
    • /
    • 제1권1호
    • /
    • pp.12-16
    • /
    • 2000
  • In this paper, we analyze self field effects of Bi-2223 tape-stacked cable assuming constant current density in the cross section of stacked cable. Generally, the critical current of Bi-2223 tape-stacked-cable in much less than the total summation of critical currents of each tape, which is mainly due to the self magnetic fields of the cable itself. Therefore, to predict the critical current of Bi-2223 tape-stacked-cable, we needs to analyze the self filed effects on the stacked cable as well as critical current density data(J$\_$C/) of one tape. To make it more complex, the critical current degradation of Bi-2223 tape is an-isotropic; the critical current is lower in the normal magnetic field(to the tape surface) than in the parallel field. In the paper, a novel approach to predict the critical current of a Bi-2223 tape-stacked-cable from a J$\_$C/-B curve of one tape is presented with the assumption of constant current density across the stacked cable, The approach basically includes the load analysis of the stacked tapes, and its usefulness is confirmed by the experimental data.

  • PDF

Mixed Hydrogen Gas Generator용 전력변환장치 개발 (Development of Mixed Hydrogen Gas Generator Power Conversion System)

  • 정장근;문상필;조길제;김창일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.88-92
    • /
    • 2007
  • In this paper, the basic experiment, electrolytic cell design and basic manufacturing have been made to interpret the characteristics of Hydrogen-Oxygen-Gas-Generator. As for the detailed matters, the data research on basic technology on Hydrogen-Oxygen-Gas and analysis on characteristics of Hydrogen-Oxygen-Gas from basic experiment. Also the experiment of characteristics and comparative evaluation between constant current source using IGBT converter from existing method and constant current source using new phase shift PWM control method converter. As results when it has injected constant DC current, we has compared Gas quantities by variable ripple frequencies using phase shift PWM control method converter. Therefore, in linear region, it has not different Gas quantities by constant DC current and by phase shift PWM control method converter. Also, it has increased Gas quantities wilder linear region when put ripple frequency at saturation region. Through, Gas quantities and input power, it has acquired higher input power per Gas quantities at put pulse curren. Therefore, when designing converter or inverter for electrolysis, which has ripple current.

  • PDF

Can be the dielectric constant of thin films as-grown at room temperature higher than that of its bulk material?

  • Jung, Hyun-June;Kim, Chung-Soo;Lee, Jeong-Yong;Yoon, Soon-Gil
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.23-23
    • /
    • 2010
  • The $Bi_2Mg_{2/3}Nb_{4/3}O_7$ (BMNO)-Bi composite films sandwiched by an $Al_2O_3$ protection layer exhibited a linear increase of a dielectric constant with increasing thickness and the 1000nm-thick BMNO-Bi composite films showed a dielectric constant (~220) higher than that of its bulk material (~210), keeping a low leakage current density of about $0.1{\mu}A/cm^2$. An enhancement of the dielectric constant in the BMNO-Bi composite films was attributed to the hybrid model combined by a space charge polarization, dipolar response, and nano-capacitors. On the other hand, 1000nm-thick BMNO-Bi composite films sandwiched by 40nm-thick BMNO layer exhibited a dielectric constant of about 450 at 100 kHz and a leakage current density of $0.1{\mu}A/cm^2$ at 6V.

  • PDF

Study of Constant Current-Constant Voltage Output Wireless Charging System Based on Compound Topologies

  • Tan, Linlin;Pan, Shulei;Xu, Changfu;Yan, Changxin;Liu, Han;Huang, Xueliang
    • Journal of Power Electronics
    • /
    • 제17권4호
    • /
    • pp.1109-1116
    • /
    • 2017
  • Wireless power transfer (WPT) technology has the advantages of intelligence and facilitation. This paper designs a WPT system applied to battery charging and provides a strategy which switches from the constant current (CC) charging mode to constant voltage (CV) charging mode. The LCL-LCL topology is used to realize the CC output, while the LCL-S (series compensation) topology is used to realize the CV output. The main factor affecting the output characteristics is extracted by analyzing the two topologies above. Based on the main factor, this paper puts forward a modified way to design the system. In addition, on-line monitors for the battery and switches are placed at receiving side, which avoids the need for introducing an information interaction module into the system. Therefore, the complexity of the controlling system is reduced. Finally, simulation and experimental analyses are carried out to verify the correctness of the compound topologies.

$CO_2$ 인버터 아크용접기의 송급속도 제어에 의한 용접성능향상에 관한 연구 (A Study on Welding Performance Improvement in $CO_2$ Inverter Arc Welding Machine by Constant Wire Feeding Rate Control)

  • 김길남;고재석;채영민;원충연;김규식;목형수;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.563-568
    • /
    • 1999
  • Generally the control method of wire feeding motor in welding machine has been used full-wave phase control method. The fire-angle control generates low frequency speed ripple, and it causes the output current ripple. So it results in the variation of welding condition and low welding performances such as spatter generation and bead state. For the purpose of welding performances improvement by speed controller in wire feeding motor, in this paper the constant speed control method for welding machine is proposed. The proposed system is composed of speed control loop and current control loop. As a result of experiment by using proposed constant wire feed experiment by using proposed constant wire feed speed controller, the output voltage and current waveform and metal transfer are maintained stably. And moreover the number of instantaneous short circuit occurrence is reduced remarkably.

  • PDF

전압일정과 전류일정 조건에서의 동전기 정화 현상에 관한 해석

  • 김병일;김기년;이호진;김수삼
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.203-206
    • /
    • 2004
  • To analysis the electrokinetic phenomena in the ground dependent on the way of applied electric power, such as constant current and constant voltage, the governing equations are derived considering advection, diffusion, ionmigration, and then they were formulated using by finite difference method. The developed program is verified by comparing the tested and predicted results reported in present papers. The results indicate that the slightly small electrical potential is predicted for constant current and for constant voltage pH near to the cathode was small than the test results. But the other predictions including the final suction, pH of electrolyte and cumulative flow are similar to the test results and predictions.

  • PDF

댐퍼의 두께와 재질 변화에 따른 초전도 선재에 미치는 자장특성 분석 (Analysis of Magnetic Field of Superconducting Winding According to the Changed Damper Thickness and Material)

  • 정재식;이상호;홍정표;조영식
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권3호
    • /
    • pp.5-8
    • /
    • 2012
  • Superconducting windings of synchronous machine have to be operated in below the critical temperature, critical current density and critical magnetic field. If one of these characteristics does not satisfied, then the quench occurred in superconducting winding. Especially the armature current dramatically increased as the superconducting generator is short-circuited at the rated load condition and magnetic field in field winding increased due to the armature current. Therefore, damper is required to reduce the magnetic field of field winding which increases reliability of the superconducting generator. Damper dimension can be decided by time constant[1-2]. In this paper the basic model is high-power and low-speed superconducting generator. Damper time constant was calculated from the changed damper thickness and material. Magnetic flux of field coil at the basic model and changed damper time constant model is analyzed.