• Title/Summary/Keyword: connectors

Search Result 548, Processing Time 0.031 seconds

Optimization of shear connectors with high strength nano concrete using soft computing techniques

  • Sedghi, Yadollah;Zandi, Yosef;Paknahad, Masoud;Assilzadeh, Hamid;Khadimallah, Mohamed Amine
    • Advances in nano research
    • /
    • v.11 no.6
    • /
    • pp.595-606
    • /
    • 2021
  • This paper conducted mainly for forecasting the behavior of the shear connectors in steel-concrete composite beams based on the different factors. The main goal was to analyze the influence of variable parameters on the shear strength of C-shaped and L-shaped angle shear connectors. The method of ANFIS (adaptive neuro fuzzy inference system) was applied to the data in order to select the most influential factors for the mentioned shear strength forecasting. Five inputs are considered: height, length, thickness of shear connectors together with concrete strength and respective slip of the shear connectors after testing. The ANFIS process for variable selection was also implemented in order to detect the predominant factors affecting the forecasting of the shear strength of C-shaped and L-shaped angle shear connectors. The results show that the forecasting methodology developed in this research is useful for enhancing the multiple performances characterizing in the shear strength prediction of C and L shaped angle shear connectors analyzing.

Electrical Impedance Change due to Contamination at the Contact Interface of Connectors for Automobile Crank Shaft Position Sensor

  • Kim, Young-Tae;Sung, In-Ha;Kim, Dae-Eun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.5 no.2
    • /
    • pp.46-52
    • /
    • 2004
  • Numerous connectors are used in automobiles for transmission of electrical signals across various electro-mechanical components. The connectors must operate with high reliability in order to minimize failures due to signal degradation. In this work, the effects of contamination at the contact interface of connectors used fur automobile crankshaft position sensor on the impedance change were investigated. An experimental set-up was built to simulate the electrical signal transmitted from the sensor to the engine control unit through a connector. Output from the connector was investigated using connectors contaminated with engine block residues and water droplets. It was found that slight contamination of the connectors could lead to significant signal degradation which can lead to engine failure. Also, the effect of water in the connector altered the signal severely. However, the signal gradually regained the original state as the water evaporated from the interface.

Investigation of pipe shear connectors using push out test

  • Nasrollahi, Saeed;Maleki, Shervin;Shariati, Mahdi;Marto, Aminaton;Khorami, Majid
    • Steel and Composite Structures
    • /
    • v.27 no.5
    • /
    • pp.537-543
    • /
    • 2018
  • Mechanical shear connectors are commonly used to transfer longitudinal shear forces across the steel-concrete interface in composite beams. Steel pipe as a new shear connector is proposed in this research and its performance to achieve composite strength is investigated. Experimental monotonic push-out tests were carried out for this connector. Then, a nonlinear finite element model of the push-out specimens is developed and verified against test results. Further, the finite element model is used to investigate the effects of pipe thickness, length and diameter on the shear strength of the connectors. The ultimate strengths of these connectors are reported and their respective failure modes are discussed. This paper comprises of the push-out tests of ten specimens on this shear connector in both the vertical and horizontal positions in different reinforced concretes. The results of experimental tests are given as load-deformation plots. It is concluded that the use of these connectors is very effective and economical in the medium shear demand range of 150-350 KN. The dominant failure modes observed were either failure of concrete block (crushing and splitting) or shear failure of pipe connector. It is shown that the horizontal pipe is not as effective as vertical pipe shear connector and is not recommended for practical use. It is shown that pipe connectors are more effective in transferring shear forces than channel and stud connectors. Moreover, based on the parametric study, a formula is presented to predict the pipe shear connectors' capacity.

Application of ANFIS technique on performance of C and L shaped angle shear connectors

  • Sedghi, Yadollah;Zandi, Yousef;Shariati, Mahdi;Ahmadi, Ebrahim;Azar, Vahid Moghimi;Toghroli, Ali;Safa, Maryam;Mohamad, Edy Tonnizam;Khorami, Majid;Wakil, Karzan
    • Smart Structures and Systems
    • /
    • v.22 no.3
    • /
    • pp.335-340
    • /
    • 2018
  • The behavior of concrete slabs in composite beam with C and L shaped angle shear connectors has been studied in this paper. These two types of angle shear connectors' instalment have been commonly utilized. In this study, the finite element (FE) analysis and soft computing method have been used both to present the shear connectors' push out tests and providing data results used later in soft computing method. The current study has been performed to present the aforementioned shear connectors' behavior based on the variable factors aiming the study of diverse factors' effects on C and L shaped angle in shear connectors. ANFIS (Adaptive Neuro Fuzzy Inference System), has been manipulated in providing the effective parameters in shear strength forecasting by providing input-data comprising: height, length, thickness of shear connectors together with concrete strength and the respective slip of shear connectors. ANFIS has been also used to identify the predominant parameters influencing the shear strength forecast in C and L formed angle shear connectors.

Behaviour and design of stainless steel shear connectors in composite beams

  • Yifan Zhou;Brian Uy;Jia Wang;Dongxu Li;Xinpei Liu
    • Steel and Composite Structures
    • /
    • v.46 no.2
    • /
    • pp.175-193
    • /
    • 2023
  • Stainless steel-concrete composite beam has become an attractive structural form for offshore bridges and iconic high-rise buildings, owing to the superior corrosion resistance and excellent ductility of stainless steel material. In a composite beam, stainless steel shear connectors play an important role by establishing the interconnection between stainless steel beam and concrete slab. To enable the best use of high strength stainless steel shear connectors in composite beams, high strength concrete is recommended. To date, the application of stainless steel shear connectors in composite beams is still very limited due to the lack of research and proper design recommendations. In this paper, a total of seven pushout specimens were tested to investigate the load-slip behaviour of stainless steel shear connectors. A thorough discussion has been made on the differences between stainless steel bolted connectors and welded studs, in terms of the failure modes, load-slip behaviour and ultimate shear resistance. In parallel with the experimental programme, a finite element model was developed in ABAQUS to simulate the behaviour of stainless steel shear connectors, with which the effects of shear connector strength, concrete strength and embedded connector height to diameter ratio (h/d) were evaluated. The obtained experimental and numerical results were analysed and compared with existing codes of practice, including AS/NZS 2327, EN 1994-1-1 and ANSI/AISC 360-16. The comparison results indicated that the current codes need to be improved for the design of high strength stainless steel shear connectors. On this basis, modified design approaches were proposed to predict the shear capacity of stainless steel bolted connectors and welded studs in the composite beams.

A Study on Strength of Shear Connectors in Composite Beams of Steel and Lightweight Concrete Slabs (경량콘크리트 슬래브와 철골보의 합성보에서 쉬어 코넥터의 강도에 관한 연구)

  • 주기수;박성무
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.10a
    • /
    • pp.356-361
    • /
    • 1994
  • From the previous experimental test results, it has shown that shear that shear strength in lightweight concrete beams was about 85% on that in normal concrete beams. It is speculated that shear connectors in composite beams of steel and lightweight concrete associated with the longitudinal shear strength decrease more in strength than those in normal concrete. So this paper, as a study on strength of shear connectors in composite beams of steel and lightweight concrete slabs, has a purpose to compare the strength formula resulted from the push-out test of thirteen solid slab and four deck Plate slab with the established ones, and then to suggest a proper strength formula of the shear connectors. The established strength formula of the shear connectors is prescribed for $P_ps = 0.50A_s . \sqrt{f_C . E_C}$by AISC coed, but from the experimental test results the strength values of the shear connectors in lightweignt concrete slabs shows about 70% on those of the shear connectors in normal concrete slabs by AISC code. Therefore, as a strength formula this paper suggests to multiply the established strength formula by reduction factor$(\varphi=0.7)$.

  • PDF

Push-out test on the one end welded corrugated-strip connectors in steel-concrete-steel sandwich structure

  • Yousefi, Mehdi;Ghalehnovi, Mansour
    • Steel and Composite Structures
    • /
    • v.24 no.1
    • /
    • pp.23-35
    • /
    • 2017
  • Current form of Corrugated-strip connectors are not popular due to the fact that the two ends of this form need to be welded to steel face plates. To overcome this difficulty, a new system is proposed in this work. In this system, bi-directional corrugated-strip connectors are used in pairs, and only one of their ends is welded to the steel face plates on each side. The other end is embedded in the concrete core. To assemble the system, common welding devices are required, and welding process can be performed in the construction sites. By performing the Push-out test under static loading, the authors experimentally assess the effects of geometric parameters on ductility, failure modes and the ultimate shear strength of the aforesaid connectors. For this purpose, sixteen experimental samples are prepared and investigated. For fifteen of these samples, one end of the shear connectors is welded to steel face plates, and the other end is embedded in the concrete. Another experimental sample is prepared in which both ends are welded to the steel face plates. According to the achieved results, several relations are proposed for predicting the ultimate shear strength and load vs. interlayer slip (load-slip) behavior of corrugated-strip connectors. Moreover, these formulas are compared with those of the well-known codes and standards. Accordingly, it is concluded that the authors' relations are more reliable.

Rotational Stiffness of Connection in Multi-span Vinyl Greenhouse (내재해형 연동 비닐하우스 접합부의 회전강성)

  • Kim, Min-Sun;Choi, Ki-Sun;Shin, Ji-Uk
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.12
    • /
    • pp.3-10
    • /
    • 2018
  • Recently, severe damage to domestic horticultural structures is frequently observed due to extreme climate effects. To minimize the structures' damage, a study on the structural stability of multi-span vinyl greenhouses is needed. This paper presents to measure the rotational stiffness of different connectors to improve the design capacities of the specification. The paper investigated fourteen types of the different connectors, which was commonly used in the multi-span greenhouses, and three different types of the connectors predicted to be under moment-connection were selected: i) T-clamp, ii) U-clamp, iii) C-clamp. Static loading tests for three different connectors were performed to measure the rotational stiffness. Additionally, the boundary condition for the structural design was proposed based on the experimental results of the rotational stiffness. One of three connectors, C-clamp had larger rotational stiffness than other connectors, and the experimental results presented the three connectors had boundary conditions; i) T-clamp was pinned-connection, ii) U-clamp was semi-rigid connection, iii) C-clamp was semi-rigid connection.

Design and Implementation of Component Connector Modeling in the .lava Beans Environment (Java Beans 환경에서 컴포넌트 연결자 모델링의 설계 및 구현)

  • 정성옥
    • Proceedings of the IEEK Conference
    • /
    • 2001.06c
    • /
    • pp.195-198
    • /
    • 2001
  • Components are abstractions of system level computational entities, connectors are abstractions of component interrelationships. we propose connectors as transferable abstractions of system level component interconnection and inter-operation. Connectors are architectural abstractions of component coordination in the abstract architecture of a system only. Connectors describe a collaboration rationale for component adaptations, which are then modeled in the concrete architecture of a system.

  • PDF

Interface Study of the Intermediate Connectors in Tandem Organic Devices

  • Tang, Jian-Xin;Lee, Shuit-Tong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.225-228
    • /
    • 2009
  • We have demonstrated several effective intermediate connectors in tandem organic light-emitting devices (OLEDs) using doped or nondoped organic p-n heterojunction. The influence of n-type or p-type organic layer in intermediate connectors on device performance has been investigated based on the understanding of interfacial electronic structures.

  • PDF