• Title/Summary/Keyword: connection socket

Search Result 35, Processing Time 0.025 seconds

Test for the influence of socket connection structure on the seismic performance of RC prefabricated bridge piers

  • Yan Han;Shicong Ding;Yuxiang Qin;Shilong Zhang
    • Earthquakes and Structures
    • /
    • v.25 no.2
    • /
    • pp.89-97
    • /
    • 2023
  • In order to obtain the impact of socket connection interface forms and socket gap sizes on the seismic performance of reinforced concrete (RC) socket prefabricated bridge piers, quasi-static tests for three socket prefabricated piers with different column-foundation connection interface forms and reserved socket gap sizes, as well as to the corresponding cast-in-situ reinforced concrete piers, were carried out. The influence of socket connection structure on various seismic performance indexes of socket prefabricated piers was studied by comparing and analyzing the hysteresis curve and skeleton curve obtained through the experiment. Results showed that the ultimate failure mode of the socket prefabricated pier with circumferential corrugated treatment at the connection interface was the closest to that of the monolithic pier, the maximum bearing capacity was slightly less than that of the cast-in-situ pier but larger than that of the socket pier with roughened connection interface, and the displacement ductility and accumulated energy consumption capacity were smaller than those of socket piers with roughened connection interface. The connection interface treatment form had less influence on the residual deformation of socket prefabricated bridge piers. With the increase in the reserved socket gap size between the precast pier column and the precast foundation, the bearing capacity of the prefabricated socket bridge pier component, as well as the ductility and residual displacement of the component, would be reduced and had unfavorable effect on the energy dissipation property of the bridge pier component.

An experimental study on different socket base connections under cyclic loading

  • Pul, Selim;Husem, Metin;Arslan, Mehmet Emin;Hamzacebi, Sertac
    • Computers and Concrete
    • /
    • v.13 no.3
    • /
    • pp.377-387
    • /
    • 2014
  • This paper presents an experimental study on socket base connections of precast reinforced concrete columns. The main purpose of this study is to determine socket base connection which has the closest behavior to monolithic casted column-base joints. For this purpose, six specimens having different column-socket base connection details were tested under cyclic loading. For each test, strength, stiffness, ductility and drift ratios of the specimens were determined. Test results indicated that a suggested connection type is 10%-30% stronger than the other type of connections under lateral loading. The welded connection (PC-5) had better lateral load carrying capacity and ductility. On the other hand, performance of standard connection (PC-1) which is commonly used in construction was weaker than other connections. Thus, decision of connection type should be referred not only performance but also applicability.

Seismic performance of precast assembled bridge piers with hybrid connection

  • Shuang, Zou;Heisha, Wenliuhan;Yanhui, Liu;Zhipeng, Zhai;Chongbin, Zhang
    • Structural Engineering and Mechanics
    • /
    • v.85 no.3
    • /
    • pp.407-417
    • /
    • 2023
  • Precast assembled bridge piers with hybrid connection (PASP) use both tendons and socket connections. To study the seismic performance of PASP, a full-scale in-situ test was performed based on an actual bridge project. The elastic-plastic fiber model of PASP was established using finite element software, and numerical analyses were performed to study the influence of prestress degree and socket depth on the PASP seismic performance. The results show that the typical failure mode of PASP under horizontal load is bending failure dominated by concrete cracking at the joint between the column and cushion cap. The cracking of the pier concrete and opening of joints depend on the prestress degree and socket depth. The prestressing tendons and socket connection can provide enough ductility, strength, restoration capability, and bending strength under small horizontal displacements. Although the bearing capacity and post yield stiffness of the pier can be improved to some extent by increasing the prestressing force, ductility is reduced, and residual deformation is increased. Overall, there are reasonable minimum socket depths to ensure the reliability of the socket connection.

A Study on Safe Permanent Joint Type Multiple Socket-Outlets Development without Soldering Crimped Connection (안전형 비납땜 틀고정 영구 접속형 멀티콘센트 개발에 관한 연구)

  • Cho, Won-Seok;Lee, Wi-Ro
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.47-54
    • /
    • 2015
  • Normally, multiple socket-outlet is manufactured with soldered, welded permanent connection (termination). Because this procedure is very non-environmental and requires many labor forces, many companies skip this process. To solve this these problems, this research had to design permanent joint type multiple socket-outlet, develop safer multiple socket-outlet than is sold in markets. Progressing this research, we took 3 steps. First, we had to design device for fixing a frame suitable for multiple socket-outlet. Second, this multiple socket-outlet must pass fundamental standards through international standard (IEC 60884-1) and Korean standard (K 60884-1) tests. Third, it had to pass both several mechanical and electrical tests which is more strict than fundamental standards and vibration and impact tests following KS standards for enhancing its safety. After finishing 3 steps, we could obtain objective and fair data, develop environmental permanent joint type multiple socket-outlet without soldering crimped connection.

Tensile Strength on Connection Socket of Cables (케이블 연결 소켓의 인장강도)

  • Park, Kang-Geun;Lee, Jang-Bok;Ha, Chae-Won;Kim, Jae-Bong
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.37-42
    • /
    • 2008
  • Cable member in structure is tension systems in which the load carrying members transmit loads to support system by tensile stress with no compression or flexure allowed. Cable system have been widely used large span structure roof, air-supported structure, prestressed membrane, cable network roof, suspension structures, guyed tower, ocean platforms, suspension bridges. Cable member can transmit loads by the edge connected system such as socket, swaging, mechanical splice sleave, clip, wedge, loop splice etc. This study will shown an experimental results on the strength of connection socket of cables. In the results of experiment, most of cable connection specimen occurred the failure at the connection socket part before the cable arrived at tensile failure load.

  • PDF

Failure analysis of steel column-RC base connections under lateral cyclic loading

  • Demir, Serhat;Husem, Metin;Pul, Selim
    • Structural Engineering and Mechanics
    • /
    • v.50 no.4
    • /
    • pp.459-469
    • /
    • 2014
  • One of the most important structural components of steel structures is the column-base connections which are obliged to transfer horizontal and vertical loads safely to the reinforced concrete (RC) or concrete base. The column-base connections of steel or composite steel structures can be organized both moment resistant and non-moment resistant leading to different connection styles. Some of these connection styles are ordinary bolded systems, socket systems and embedded systems. The structures are frequently exposed to cycling lateral loading effects causing fatal damages on connections like columns-to-beams or columns-to-base. In this paper, connection of steel column with RC base was investigated analytically and experimentally. In the experiments, bolded connections, socket and embedded connection systems are taken into consideration by applying cyclic lateral loads. Performance curves for each connection were obtained according to experimental and analytical studies conducted and inelastic behavior of connections was evaluated accordingly. The cyclic lateral performance of the connection style of embedding the steel column into the reinforced concrete base and strengthening of steel column in upper level of base connection was found to be higher and effective than other connection systems. Also, all relevant test results were discussed.

The Development of Extension Card(Socket Jig) for Memory Module Test (메모리 모듈 시험용 확장 카드(Socket Jig) 개발)

  • 최종문;김선주;김동진;홍철호;정영창
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.4
    • /
    • pp.372-379
    • /
    • 2003
  • In order to improve a damage of connection part of Main Board Memory, we developed a hazard extension card(Socket Jig). The damage occurs during the test of the memory module product of the Desktop-PC. The connection part of main board was broken by 15% per a day before the development. There existed two major problems; One was that we must obtain more than 15% of surplus equipment. while the other was that we needed people who were wholly responsible for repair. The development of extension card decreased operation delay. Besides, it improved capacity of surplus equipment and operation efficiency. Therefore, we can save 78,000,000 won per year.

  • PDF

Experimental Analysis of the fixed socket strength of a removable soil nail (제거식 쏘일네일의 고정자소켓 강도에 관한 실험적 해석)

  • Kim, Nak-Kyung;Kim, Sung-Kyu;Yun, Seung-Kwon;Cho, Kyu-Wan;Kim, Woong-Kyu;Lee, Chung-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.1250-1253
    • /
    • 2008
  • As a reinforcement technique, the application of removable soil nailing has been extended to solve the public grievance of typical soil nailing such as the geotechnical environmental problem and invasion of adjacent land. In the case of removable soil nailing, pullout capacity of the nail depends on the adhesive strength of a fixed socket. Because the existing fixed socket is made from a plastic product, the strength of a socket is less than a steel bar and then the yield failure by abrasion and deformation is occurred on the steel bar-socket contact surface. In this study, therefore, experimental analysis from laboratory test of a removable soil nail equipped with steel socket, improving the adhesive strength of steel bar-socket connection is performed to estimate the increase effect of pullout capacity of a soil nail.

  • PDF

Java API for Native ATM Services (순수 ATM 서비스를 제공하는 자바 API)

  • Seong, Jong-Jin;Lee, Geun-Gu;Kim, Jang-Gyeong
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.7
    • /
    • pp.1884-1896
    • /
    • 1999
  • In this paper, we propose an ATM API for Java pplication programming. The proposed Java ATM API is an extended form of java.net package of the Java Core API. Our Java ATM API is defined based on the ATM Forum's semantic standard for native ATM services, "Native ATM Service : Semantic Description, Version 1.0". IN order to provide native ATM services, we defined several new classes within the java.net package, including AtmAddress for AtmAddress, AtmSocket, ATM BLLI and AtmBHLI for Atm BLLI and BHLI information, AtmServerSocket, AtmMulticastSocket, AtmSocketImpl for socket programming over native ATM communication, and AtmConnAttr for native ATM connection characteristics. Software structure for construcing the Java ATM API over Winsock 2 environment and its implementation method are also presented.

  • PDF

Morphology of Retinas and Lenses in the Fish of the Genus Zacco (Cypriniformes, Cyprinidae): Possible Relationship with Prey and Habitat

  • Lim, Jae-Won;Lee, Chung-Lyul;Lee, Moo-Sam
    • Animal cells and systems
    • /
    • v.7 no.4
    • /
    • pp.331-335
    • /
    • 2003
  • Vertebrates with different habitats have different proportions of visual cells, with the rod cells responding to scotopic vision and the cone cells responding to photopic and color vision in their retinas. The present work studied whether the kinds and arrangement patterns of the cone cells and interlocking morphology of the lens were related to the kind of preys and habitats in the genus Zacco. The retinas were observed by a light microscopy using H-E staining method and the interlocking formula of the lens fibers were investigated by a scanning electron microscopy. The interlocking formula of the lens fibers of Z. temmincki is an ' anchor and socket ' connection, and that of Z. platypus is a ' ball and socket ' connection. The cone cells of Z. platypus and Z. temmincki constituted compacted mosaic patterns of row type. Away from the center, the double and single cone cells gradually increased in diameter. Zacco temmincki had identical double cone cells and Z. platypus had non-identical double and single cone cells. The eyes of Z. temminckifeeding on a moving aquatic insects in relative limpid water and swift current of mid and upper stream have better resolution than that of Z. platypus feeding on mainly adhesive algae and some aquatic insects in slightly turbid water of mid stream.