• 제목/요약/키워드: conjugated heat transfer

검색결과 23건 처리시간 0.032초

국부적인 발열부분을 가진 표면에서의 잠김 비등열전달 -전자부품 액침 냉각에서의 응용- (Boiling Heat Transfer from a locally Heated Surface -A Simulated Electronic Device under Liquid Immersion Cooling-)

  • 하광순;최상민
    • 대한기계학회논문집
    • /
    • 제15권2호
    • /
    • pp.685-692
    • /
    • 1991
  • The pool boiling behavior of a heated surface has been investigated experimentally, focusing on the cases when only a part of the contact surface is heated. Characteristic boiling curves are obtained with circular metal surface test pieces heated below while immersed in Refrigerant-113. Locally heated test pieces are fabricated by inserting a heating block at the center inside a larger conducting block. Overall heat transfer rates are measured while the experimental conditions are systematically varied. The local temperature profiles along the radius are measured for conducting blocks. It is found that the conjugated boiling condition exists and the total heat fluxes should be correlated to a suitably defined temperature difference.

적층형 디지털송수신모듈의 방열특성 분석 (Analysis on Heat Dissipation Characteristics of a Tile-Type Digital Transmitter/Receiver Module)

  • 윤기철;김상운;허재훈;곽노진;김찬홍
    • 한국군사과학기술학회지
    • /
    • 제22권2호
    • /
    • pp.249-254
    • /
    • 2019
  • A Digital Transmitter/Receiver Module(DTRM), which is an essential part in active phased-array radar systems, generates a high heat density, and needs to be properly cooled for stable operation. A tile-type DTRM that is a stacking structure of multi-layer components was modeled with simplification and heat dissipation characteristics of the DTRM model were studied using computational fluid dynamics(CFD) simulations. Most of the heat was dissipated by the heat conduction through the cold plate, but the heat transfer by the forced convection on top of the DTRM also was found to play an important role in the thermal management. Under the given conjugated heat transfer environment, the DTRM was confirmed to secure a stable operating temperature range.

Thermal study of the emergency draining tank of molten salt reactor

  • C. Peniguel
    • Nuclear Engineering and Technology
    • /
    • 제56권3호
    • /
    • pp.793-802
    • /
    • 2024
  • In the framework of the European project SAMOSAFER, this numerical study focuses on some thermal aspects of the Emergency Draining Tank (EDT) located underneath the core of a Molten Salt Reactor. In case of an emergency, this tank passively receives the liquid fuel salt and is designed to ensure a subcritical state. An important requirement is that the fuel does not overheat to maintain the EDT Hastelloy container integrity. The present EDT is based upon a group of hexagonal cooling assemblies arranged in a hexagonal grid and cooled down thanks to conduction through the inert salt layer up to an air flow in charge of removing the heat. This numerical thermal study relies on a conjugated heat transfer analysis coupling a Finite Element solid thermal code (SYRTHES) and two instances of a Finite Volume CFD codes (Code_Saturne). Calculations on an initial design suggest that a simple center airpipe flow is likely to not sufficiently cool the device. Alternative solutions have been evaluated. Introduction of fins to enhance the heat transfer do not bring a noticeable improvement regarding maximum temperature reached. However, a solution in which the central pipe air flow is replaced by several cooling channels located closer to the fuel is investigated and suggests a better cooling.

연직 원통윈에서의 혼합대류-전도 복합열전달에 미치는 복사효과 (Radative Effect on the Conjugate Mixed Convection-Conduction Heat Transfer along a Vertical Circular Cylindrical Fin)

  • 최상경;여문수;손병진
    • 대한기계학회논문집
    • /
    • 제15권5호
    • /
    • pp.1706-1716
    • /
    • 1991
  • 본 연구에서는 혼합대류하는 연직원통휜 열전달에 미치는 복사효과에 Rossel- and 근사해법을 도입한 층류 경계층방정식과 휜 전도방정식을 동시에 해석하여 복사 -전도매개변수(radiation-conduction parameter) M, 대류-전도 매개변수(convectionc- onduction parameter) N$_{c}$, 부력매개변수(buoyancy force parameter) R$_{i}$ 그 리고 횡곡률 매개변수(transverse curvature parameter) .lambda.를 계산 파라미터로 하여 휜 최적설계의 기본이 되는 총열전단률, 무차원 국소등가열전달계수, 무차원 국소열플 럭스 및 휜온도분포를 계산할 수 있는 일반성있는 algorithm을 개발하고 휜 성능에 관 한 결과들을 제공함으로써, 좀 더 완전한 복사 열플럭스를 도입한, 다음 연구를 위한 범용의 기초자료를 얻는데 본 연구의 목적이 있다.

로울러 킬른 내의 이동현상에 관한 전산모사 (A computer simulation of transport phenomena in a roller kiln)

  • 이성철;김병수
    • 한국결정성장학회지
    • /
    • 제9권2호
    • /
    • pp.251-259
    • /
    • 1999
  • 로울러 킬른 내의 이동현상에 대하여 전산모사를 수행하였다. 소결 공정에서 중요한 요소인 로울러 킬른 내의 온도분포와 속도장을 구하기 위하여 유한요소법을 이용하여 에너지 보존식과 운동량 보존식을 풀었다. 로울러 킬른 내에 세라믹 원료가 없을 경우에, 벽면의 열원으로부터 유입되는 공기로 빠르게 열전달이 이루어지게 되며 공기는 이 열의 대부분을 로울러 킬른 밖으로 전달하는 것을 알 수 있었다. 세라믹 원료가 있을 경우에, 세라믹 원료는 벽면으로부터 열을 받아 온도가 상승하게 되나 상대적으로 차가운 공기의 유동 때문에 인하여 공기로 많은 열을 빼앗기게 되는 것을 알 수 있었다. 자연대류에 의한 열전달로 인하여 소성대인 영역 5에서 세라믹 원료의 바닥과 윗면에서 온도 차이가 255K 정도 생겼다. 마지막으로 복사 열전달을 고려하였을 경우에 세라믹 원료 표면에서의 복사 열전달로 인하여 전도와 자연대류만 고려하였을 때보다 온도 차이가 45 K 정도 더 생겼다.

  • PDF

Numerical investigation on ballooning and rupture of a Zircaloy tube subjected to high internal pressure and film boiling conditions

  • Van Toan Nguyen;Hyochan Kim;Byoung Jae Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2454-2465
    • /
    • 2023
  • Film boiling may lead to burnout of the heating element. Even though burnout does not occur, the heating element is subject to deformation because it is not sufficiently strong to withstand external loads. In particular, the ballooning and rupture of a tube under film boiling are important phenomena in the field of nuclear reactor safety. If the tube-type cladding of nuclear fuel ruptures owing to high internal pressure and thermal load, radioactive materials inside the cladding are released to the coolant. Therefore, predicting the ballooning and rupture is important. This study presents numerical simulations to predict the ballooning behavior and rupture time of a horizontal tube at high internal pressure under saturated film boiling. To do so, a multi-step coupled simulation of conjugated film boiling heat transfer and ballooning using creep model is adopted. The numerical methods and models are validated against experimental values. Two different nonuniform heat flux distributions and four different internal pressures are considered. The three-step simulation is enough to obtain a convergent result. However, the single-step simulation also successfully predicts the rupture time. This is because the film boiling heat transfer characteristics are slightly affected by the tube geometry related to creep ballooning.

RP4::Mu cts에 의한 Rhizobium leguminosarum 질소고정 유전자의 속간전달에 관한 연구 (Intergeneric Transfer of Nitrogen Fixation Genes from Rhizobium leguminosarum by RP4::Mu cts)

  • 허연주;이영록
    • 미생물학회지
    • /
    • 제24권3호
    • /
    • pp.211-220
    • /
    • 1986
  • Nitrogen fixation (nif) genes of Rhizobium leguminosarum were transferred to nif Klebsiella pneumoniae and E. coli by conjugation after partial heat induction of $RP_4$ :: Mu cts in Rhizobium $R^+$ transconjugant, and the hybrid plasmids in the transconjugant strains were isolated and characterized. In order to transfer the nif genes from Rhizobium, the hybrid plasmid $RP_4$ :: Mu cts was transferred by conjugation from E. coil to the symbiotic nitrogen fixer, R. leguminosarum. After stabillity test, the $RP_4$ :: Mu cts in Rhixobium $R^+$ transconjugant was subjected to partial heat induction by culturing it statically at $38^{\circ}C$ for 16 hours, and then conjugated with the nif defective mutant strains of K. pneumoniae or nif mutant strains of E. coli having whole nif gene plasmid. Recombinant strains of K. pneumoniae, which could grow in a N-free medium and exhibit the nitrogenase activity were selected. However, in the case of E. coli, they could grow well in a NA medium containing antibiotices, but hardly frow in a N-free medium. The hybrid plasmids in these transconjugal strains were isolated by gel electrophoresis and compared their molecular sizes.

  • PDF

가열된 표면에 고착된 액적의 증발 특성에 관한 수치해석 연구 (Numerical Analysis of the Sessile Droplet Evaporation on Heated Surfaces)

  • 정찬호;이형주;윤국현;이성혁
    • 한국분무공학회지
    • /
    • 제26권1호
    • /
    • pp.1-8
    • /
    • 2021
  • Droplet evaporation has been known as a common phenomenon in daily life, and it has been widely used for many applications. In particular, the influence of the different heated substrates on evaporation flux and flow characteristics is essential in understanding heat and mass transfer of evaporating droplets. This study aims to simulate the droplet evaporation process by considering variation of thermal property depending on the substrates and the surface temperature. The commercial program of ANSYS Fluent (V.17.2) is used for simulating the conjugated heat transfer in the solid-liquid-vapor domains. Moreover, we adopt the diffusion-limited model to predict the evaporation flux on the different heated substrates. It is found that the evaporation rate significantly changes with the increase in substrate temperature. The evaporation rate substantially varies with different substrates because of variation of thermal property. Also, the droplet evaporates more rapidly as the surface temperature increases owing to an increase in saturation vapor pressure as well as the free convection effect caused by the density gradient.

Cantera를 이용한 케로신 다단연소사이클 엔진용 산화제 과잉 예연소기 설계코드 개발 (Development of Design Code for Oxidizer-Rich Preburner of Staged Combustion Cycle Engine Using Cantera)

  • 강시윤;김성구;유철성;문인상
    • 한국추진공학회지
    • /
    • 제26권6호
    • /
    • pp.10-20
    • /
    • 2022
  • 본 연구에서는 케로신 다단연소사이클 엔진용 예연소기를 설계하기 위해, 고압의 산화제 과잉 조건에서 예연소가스를 계산하고 냉각유로에서 극저온 유체의 복합열전달 및 수력 특성을 해석할 수 있는 설계코드를 개발하였다. 사용자 편의성과 범용성을 가진 오픈 소스 라이브러리 Cantera를 활용하였으며, 실제유체의 열역학/전달 상태량을 정확히 계산하기 위해 관련 소스 코드들을 새로 작성하여 Cantera에 추가하였다. 현재 예비설계 중인 100톤급 부스터 엔진용 예연소기에 적용하였으며, CFD 해석결과와 비교를 통해 설계코드로서의 예측 정확도와 활용성을 확인하였다.

핀틀이 적용된 고온 가스 밸브의 비정상상태 해석 기법에 관한 연구 (Study on Transient Analysis of Hot Gas Valve with Pintle)

  • 이경욱;허선욱;권세진;이종광
    • 한국추진공학회지
    • /
    • 제22권2호
    • /
    • pp.152-159
    • /
    • 2018
  • 고온밸브의 비정상상태 복합열전달 해석 기법을 확립하기 위한 연구를 수행하였다. 장시간 작동하는 고온밸브의 특성과 해석의 경제성을 고려하여 두 가지 해석 기법을 제시하였다. 발달순서에 따라 구간을 나누고 구간별로 시간간격을 증가시켜 해석을 수행하는 다 구간 해석 기법과 정상상태 유동장 해석결과를 비정상상태 해석의 초기 값으로 사용하는 one-way 해석 기법을 제시 하였다. 다 구간 해석 기법의 경우 신뢰도가 높은 해석이 수행 가능하지만 경제적인 측면에서 설계 단계의 해석 기법으로는 부적합하였다. one-way 해석 기법의 경우 초기 신뢰도는 떨어지나 기민한 설계 변수 연구가 가능한 경제적인 해석 수행이 가능하였다.