• 제목/요약/키워드: confinement steel amount

검색결과 30건 처리시간 0.022초

횡방향철근 구속효과를 고려한 철근콘크리트 기둥의 축력-모멘트 상관도 (PM Interaction Diagram of RC Columns considering Confinement Effect of Transverse Steels)

  • 손혁수;양병홍;윤철균;이재훈
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2005년도 학술발표회 논문집
    • /
    • pp.324-330
    • /
    • 2005
  • The flexural strength and ductility capacity of reinforced concrete columns are largely dependent on the amount of transverse steel. However, current design code does not specify the confinement effect of transverse steels in strength calculation. A non-linear moment-curvature analysis of RC column sections was conducted in order to develop PM interaction diagram considering transverse reinforcement effects. In this paper, a more reasonable application method of PM interaction diagram considering transverse steel amounts is introduced and proposed, based on moment-curvature non-linear analysis. Also, we proposed simplified method to use. easily in practical design.

  • PDF

Partial sectional confinement in a quasi-encased steel-concrete composite beam

  • Hassanzadeh, Amir Masoud;Dehestani, Mehdi
    • Computers and Concrete
    • /
    • 제22권3호
    • /
    • pp.269-278
    • /
    • 2018
  • In the recent decades, the application of composite materials, due to their desirable properties, has increased dramatically. In the present study, a quasi-encased trapezoidal section composite steel beam encased with concrete is thoroughly examined. Calculation of the load bearing capacity is carried out by finite element modeling of concrete and FRP beams with trapezoidal section under the effect of controlled displacement loading. The results are then validated comparing to the existing experimental results obtained from similar studies. Further on, the materials are changed to steel and concrete, and the section is de-signed in such a way that both concrete and steel reach a high percent-age of their load bearing capacity. In the last step, the parameters affecting the bending capacity and the behavior of the semi-confined composite beam are investigated. Results revealed that the beam diagonal web thickness plays the most effective role in load bearing capacity amongst other studied parameters. Furthermore, by analyzing the results on the effect of different parameters, an optimal model for primary beam section is presented, which exhibits a greater load bearing capacity compared to the initial design with the same amount of materials used for both sections.

FRP로 구속된 콘크리트 압축부재의 구속효과 분석 (Analysis of Confinement Effectiveness for FRP Confined Concrete Columns)

  • 최은수;최승환
    • 대한토목학회논문집
    • /
    • 제31권1A호
    • /
    • pp.19-24
    • /
    • 2011
  • FRP 자켓으로 콘크리트를 보강하는 경우 FRP의 탄성계수에 따라 강도증진효과가 상이하게 나타난다. 본 논문에서는 기존의 데이터를 사용하여 FRP 보강재의 탄성계수에 따른 보강효과를 분석하고, 실용적으로 사용할 수 있는 강도증진 추정모델을 제시하였다. FRP의 탄성계수는 일반 콘크리트의 압축탄성계수와 강재의 탄성계수를 기준으로 세 구간으로 구분하여 비교하였다. FRP의 탄성계수가 증가할수록 추정모델의 기울기 및 y-절편이 증가하는 것을 알 수 있었다. 또한, FRP의 탄성계수가 콘크리트의 압축탄성계수보다 작은 경우 FRP의 보강량이 작으며 보강효과가 없는 것으로 나타났으며, 이러한 경우 선형적인 모델을 사용하기 어렵다. 따라서 본 연구에서는 FRP의 탄성계수가 콘크리트 압축탄성계수보다 약 2배 큰 것만을 사용하는 경우의 보강효과 추정모델을 제시하였다. 본 연구에서 제시한 모델은 y-절편의 구속조건 여부와 상관없이 거의 동일한 결과를 보여 주었으며, 이러한 특징은 강재보강에서도 발견되는 것으로 합리적인 결과라고 판단할 수 있다.

축력이 재하된 원형 콘크리트 충전강관 기둥의 최대 저항능력 (Ultimate Resisting Capacity of Axially Loaded Circular Concrete-Filled Steel Tube Columns)

  • 곽효경;곽지현
    • 콘크리트학회논문집
    • /
    • 제24권4호
    • /
    • pp.423-433
    • /
    • 2012
  • 콘크리트 충전 강관 기둥은 축하중 재하시 콘크리트에 구속응력이 발생함에 따라 콘크리트의 강도가 증가한다. 콘크리트의 강도 증가분은 발생된 구속응력의 크기에 종속되므로 비선형 해석을 통하여 원형 콘크리트 충전 강관의 축방향 하중에 대한 최대 저항능력을 산정하였다. 콘크리트의 포아송비 및 응력-변형률 관계와 같은 비선형 재료 특성을 고려하였으며, 강관의 다축 항복조건을 기준으로 최대 구속응력을 산정하였다. 실험 결과와의 비교를 통하여 제안된 모델을 검증하였으며, 회귀분석을 통하여 D/t 비율 및 재료성질에 따른 최대 구속응력 산정법을 단순화하였다. Eurocode 4 설계 기준 및 기존에 제안된 다양한 경험식과의 비교를 통하여 제안된 회귀분석식의 타당성을 검증하였다.

Steel Strap으로 횡구속된 무철근 바닥판의 정적 및 피로거동 특성 연구 (A Study on Static and Fatigue Behavior of Restrained Concrete Decks without Rebar by Steel Strap)

  • 조병완;김철환
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권5호
    • /
    • pp.137-147
    • /
    • 2012
  • 무철근 교량 바닥판은 콘크리트 내부의 철근을 없애고 거더를 Strap으로 횡구속시켜 Arching action을 극대화시킨 교량 바닥판이다. 본 연구에서는 무철근 바닥판의 균열제어를 목적으로 FRP bar의 배치량을 변수로 하여 내하력과 균열, 연성도, 파괴시 응력수준 등을 판단하여 FRP bar 최소 배치량을 제시하였다. 실험결과 Steel strap 무철근 바닥판은 최소 0.15% FRP 보강근만 배치하여도 내하력과 연성이 확연히 향상됨을 확인하였다. FRP bar를 보강한 무철근 바닥판에 대하여 피로실험을 수행하였으며 200만회 반복하중 재하후 균열, 잔류 처짐 등에서 장기 사용성에 문제가 없음을 확인하였다. 교량 바닥판은 대체로 펀칭전단 파괴를 하며 2방향 슬래브의 전단강도식을 적용할 수 있으나 ACI, AASHTO 등에서는 바닥판의 비선형 파괴형상과 횡구속에 의한 Arching 효과를 명확히 고려하지 못하기 때문에 실제 파괴강도보다 과소평가 한다. 본 연구에서는 Steel strap 바닥판의 실제 파괴형상과 Strap에 의한 횡구속도를 고려한 펀칭전단강도식을 제안하였으며 이는 실험결과와도 비교적 잘 일치하는 결과를 보여주었다.

장방형 띠철근을 이용한 팔각형 플레어 RC 기둥의 파괴거동 (Failure Behavior of Octagonal Flared RC Columns Using Oblong Hoops)

  • 고성현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권3호
    • /
    • pp.58-68
    • /
    • 2014
  • 횡방향철근은 기둥의 소성힌지구간에 충분한 구속효과, 축방향철근의 좌굴방지와 연성거동을 확보하기 위해 적용된다. 기둥에서 사각형 후프 띠철근과 보강 띠철근의 조립 및 배근방법은 시공이 까다롭고 많은 횡방향철근량이 요구된다. 본 논문에서, 이러한 문제점들을 해결하기 위하여 장방형 단면과 플레어 기둥의 횡구속을 위한 장방형 후프 띠철근을 사용한 새로운 횡구속 방법이 제안되었다. 팔각 장방형 단면에 대한 실험적 연구는 플레어 기둥의 강축에 대해 수행되었다. 장방형 띠철근을 적용한 횡구속 방법은 만족할 만한 횡구속 성능을 나타내었다. 개발된 장방형 후프 띠철근 상세는 장방형 단면과 플레어 기둥의 시공성과 경제성을 향상시켜줄 수 있는 하나의 대안으로서 적용 가능한 것으로 판단된다.

Inelastic design of high-axially loaded concrete columns in moderate seismicity regions

  • Ho, Johnny Ching Ming
    • Structural Engineering and Mechanics
    • /
    • 제39권4호
    • /
    • pp.559-578
    • /
    • 2011
  • In regions of high seismic risk, high-strength concrete (HSC) columns of tall buildings are designed to be fully ductile during earthquake attack by providing substantial amount of confining steel within the critical region. However. in areas of low to moderate seismic risk, the same provision of confining steel is too conservative because of the reduced seismic demand. More critically, it causes problematic steel congestion in the beam-column joints and column critical region. This will eventually affect the quality of concrete placing owing to blockage. To relieve the problem, the confining steel in the critical region of HSC columns located in low to moderate seismicity regions can be suitably reduced, while maintaining a limited ductility level. Despite the advantage, there are still no guidelines developed for designing limited ductility HSC columns. In this paper, a formula for designing limited ductility HSC columns is presented. The validity of the formula was verified by testing half-scale HSC columns subjected to combined high-axial load and flexure, in which the confining steel was provided as per the proposed formula. From the test results, it is evident that the curvature ductility factors obtained for all these columns were about 10, which is the generally accepted level of limited ductility.

철근콘크리트 교각 심부구속철근량의 비교연구 (comparative Study on confinement Steel Amount of RC Column Bent)

  • 이재훈
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1999년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.239-246
    • /
    • 1999
  • recently there have been many destructive seismic events in Kobe Japan in 1995 and in Northridge California USA in 1994. etc. The Korean Bridge Design Standard Specifications adopted the seismic design requirements in 1992. Comparing the earthquake magnitude in Korea with those in the west coast of the USA it may be said that the current seismic design requirements of the Korean Bridge Design Standard Specifications provides too conservation design results especially for transverse reinforcement details and amount in reinforced concrete columns. This fact usually makes construction problems in concrete casting due to transverse reinforcement congestion. And the effective stiffness Ieff depends on the axial load P(Ag{{{{ {f }_{ck } }}) and the longitudinal reinforcement ratio Ast/Ag and it is conservative to use the effective stiffness Ieff than the gross section moment Ig. Seismic design for transverse reinforcement content of concrete column is considered of extreme-fiber compression strain R-factor axial load and stiffness etc.

  • PDF

Improvement of the cyclic response of RC columns with inadequate lap splices-Experimental and analytical investigation

  • Kalogeropoulos, George I.;Tsonos, Alexander-Dimitrios G.
    • Earthquakes and Structures
    • /
    • 제16권3호
    • /
    • pp.279-293
    • /
    • 2019
  • The overall seismic performance of existing pre 1960-70s reinforced concrete (RC) structures is significantly affected by the inadequate length of columns' lap-spliced reinforcement. Due to this crucial structural deficiency, the cyclic response is dominated by premature bond - slip failure, strength and stiffness degradation, poor energy dissipation capacity and low ductility. Recent earthquakes worldwide highlighted the importance of improving the load transfer mechanism between lap-spliced bars, while it was clearly demonstrated that the failure of lap splices may result in a devastating effect on structural integrity. Extensive experimental and analytical research was carried out herein, to evaluate the effectiveness and reliability of strengthening techniques applied to RC columns with lap-spliced reinforcement and also accurately predict the columns' response during an earthquake. Ten large scale cantilever column subassemblages, representative of columns found in existing pre 1970s RC structures, were constructed and strengthened by steel or RC jacketing. The enhanced specimens were imposed to earthquake-type loading and their lateral response was evaluated with respect to the hysteresis of two original and two control subassemblages. The main variables examined were the lap splice length, the steel jacket width and the amount of additional confinement offered by the jackets. Moreover, an analytical formulation proposed by Tsonos (2007a, 2019) was modified appropriately and applied to the lap splice region, to calculate shear stress developed in the concrete and predict if yielding of reinforcement is achieved. The accuracy of the analytical method was checked against experimental results from both the literature and the experimental work included herein.

Experimental study on seismic behavior of RC beam-column joints retrofitted using prestressed steel strips

  • Yang, Yong;Chen, Yang;Chen, Zhan;Wang, Niannian;Yu, Yunlong
    • Earthquakes and Structures
    • /
    • 제15권5호
    • /
    • pp.499-511
    • /
    • 2018
  • This paper aims to investigate the seismic performance of the prestressed steel strips retrofitted RC beam-column joints. Two series of joint specimens were conducted under compression load and reversed cyclic loading through quasi-static tests. Based on the test results, the seismic behavior of the strengthened joints specimens in terms of the failure modes, hysteresis response, bearing capacity, ductility, stiffness degradation, energy dissipation performance and damage level were focused. Moreover, the effects of the amount of the prestressed steel strips and the axial compression ratio on seismic performance of retrofitted specimens were analyzed. It was shown that the prestressed steel strips retrofitting method could significantly improve the seismic behavior of the RC joint because of the large confinement provided by prestressed steel strips in beam-column joints. The decrease of the spacing and the increase of the layer number of the prestressed steel strips could result in a better seismic performance of the retrofitted joint specimens. Moreover, increasing the axial compression ration could enhance the peak load, stiffness and the energy performance of the joint specimens. Furthermore, by comparison with the specimens reinforced with CFRP sheets, the specimens reinforced with prestressed steel strips was slightly better in seismic performance and cost-saving in material and labor. Therefore, this prestressed steel strips retrofitting method is quite helpful to enhance the seismic behavior of the RC beam-column joints with reducing the cost and engineering time.