• 제목/요약/키워드: confined system

검색결과 387건 처리시간 0.031초

밀폐공간에서 스마트 안전기술 적용 사례 연구 (Case study on Smart Safety Technology Application To Confined Space)

  • 정태회;소한섭;서경득;진정일;박교식
    • 한국산업보건학회지
    • /
    • 제31권4호
    • /
    • pp.503-509
    • /
    • 2021
  • Objectives: The utility of the system was analyzed by applying the smart safety technology system to the aging pipe rehabilitation facility construction classified as a confined space. Methods: Smart safety management system was applied to a site where the aging pipe rehabilitation work was in progress. The working environment was measured for 25 days, and the toxic gas saturation was analyzed according to the working time and working place. Results: Based on the measured results, two characteristic environmental changes in the confined space were confirmed. First, when working inside an aging pipe, the tendency of carbon dioxide saturation increases with working time and the number of workers. Second, oxygen decreases when working in a space away from the entrance. Conclusions: Various applications of smart safety technology have been confirmed based on the measured data, and this is expected to be useful for environmental characteristic analysis and safety management when applied to a confined space composed with various conditions in the future.

Wireless safety monitoring of a water pipeline construction site using LoRa communication

  • Lee, Sahyeon;Gil, Sang-Kyun;Cho, Soojin;Shin, Sung Woo;Sim, Sung-Han
    • Smart Structures and Systems
    • /
    • 제30권5호
    • /
    • pp.433-446
    • /
    • 2022
  • Despite efforts to reduce unexpected accidents at confined construction sites, choking accidents continue to occur. Because of the poorly ventilated atmosphere, particularly in long, confined underground spaces, workers are subject to dangerous working conditions despite the use of artificial ventilation. Moreover, the traditional monitoring methods of using portable gas detectors place safety inspectors in direct contact with hazardous conditions. In this study, a long-range (LoRa)-based wireless safety monitoring system that features the network organization, fault-tolerant, power management, and a graphical user interface (GUI) was developed for underground construction sites. The LoRa wireless data communication system was adopted to detect hazardous gases and oxygen deficiency within a confined underground space with adjustable communication range and low power consumption. Fault tolerance based on the mapping information of the entire wireless sensor network was particularly implemented to ensure the reliable operation of the monitoring system. Moreover, a sleep mode was implemented for the efficient power management. The GUI was also developed to control the entire safety-monitoring system and to manage the measured data. The developed safety-monitoring system was validated in an indoor testing and at two full-scale water pipeline construction sites.

국외 질식재해 예방규정 비교를 통한 국내 규정 개선방안 (Comparison and Improvement of Domestic and Foreign Regulations for the Prevention of Suffocation Accidents)

  • 임대성;이승길;김치년;조기홍;이광용
    • 한국산업보건학회지
    • /
    • 제31권1호
    • /
    • pp.83-93
    • /
    • 2021
  • Objectives: 'Confined space' was only defined in the Safety and Health Regulations as a place where oxygen deficiency and hydrogen sulfide must be dealt with at the time of the initial enactment (1982). The danger of fire and explosion were added in 2003. We will compare and review the regulations related to confined space work under the current safety and health rules alongside regulations in other countries and prepare a plan to improve the system through enhanced clarity and execution. Methods: In a comparison of systems for the prevention of suffocation in confined spaces in major countries (Germany, United States, Japan) different concepts of the definition of confined spaces in different countries apparently due to differences in each country's legal implementation system, accident analysis methods, the status of safety and health implementation in workplaces, the precautions against actual confined space work, and the definition of confined spaces were found to be not much different between Korea and the other foreign countries. Results: In the case of Germany and the United States, a confined space is defined as a contextual concept rather than a place, so more careful attention is needed from operators or enclosed space managers as it is often necessary to judge the actual workplace. In the case of Korea and Japan, the interior of the place is mainly defined as a place, especially in the case of Japan, which concentrates on oxygen deficiency and hydrogen sulfide poisoning. Conclusions: For measures to improve regulations on the prevention of suffocation accidents in Korea, I would like to propose three major measures to improve the system in the rules on domestic industrial safety and health standards. It is necessary to prepare and provide a guide to ensure that the 18 types of confined spaces currently defined as confined spaces are clearly understood by field management supervisors or workers.

Experimental study and modelling of CFRP-confined damaged and undamaged square RC columns under cyclic loading

  • Su, Li;Li, Xiaoran;Wang, Yuanfeng
    • Steel and Composite Structures
    • /
    • 제21권2호
    • /
    • pp.411-427
    • /
    • 2016
  • While the cyclic behaviour of fiber-reinforced polymer (FRP)-confined columns is studied rather extensively, the cyclic response especially the energy dissipation of FRP-confined damaged and undamaged square RC columns is not yet fully understood. In this paper, an experimental and numerical investigation was conducted to study the cyclic behavior of two different types of Carbon FRP (CFRP)-confined square RC columns: strengthened and repaired. The main variables investigated are initial damage, confinement of CFRP, longitudinal steel reinforcement ratio. The experimental results show that lower initial damage, added confinement with CFRP and longitudinal reinforcement enhance the ductility, energy dissipation capacity and strength of the columns, decrease the stiffness and strength degradation rates of all CFRP-confined square RC columns. Two hysteretic constitutive models were developed for confined damaged and undamaged concrete and cast into the non-linear beam-column fiber-based models in the software Open System for Earthquake Engineering Simulation (OpenSees) to analyze the cyclic behavior of CFRP-confined damaged and undamaged columns. The results of the numerical models are in good agreement with the experiments.

내부 구속 중공 CFT 기둥의 내화 성능에 대한 해석 연구 (Analytical Study on the Fire Resistance of Internally Confined Hollow CFT Column)

  • 원덕희;한택희;박종섭;강영종
    • 한국강구조학회 논문집
    • /
    • 제21권5호
    • /
    • pp.461-470
    • /
    • 2009
  • 기둥은 축하중과 지진하중에 저항하는 주부재로서 구조물에서 가장 중요한 부재중의 하나이다. 이러한 기둥은 화재 시 고온에 의해 그 성능이 저하되어 전체 구조물계에 심각한 균열을 초래할 수 있으며, 구조물의 붕괴로도 이어질 수 있다. 본 연구에서는 새로운 형식의 기둥인 내부구속 중공 콘크리트 충전강관 기둥 (ICH CFT column; Internally Confined Hollow Concrete Filled Tube column)의 내화 성능이 연구되어져 있지 않기 때문에 건축물에 적용을 하여 기준에 맞는 기둥을 만들기 위해서는 내화 성능 평가가 필요하다. 본 기둥은 콘크리트 충전 강관 기둥 (CFT column; Concrete Filled Tube column)과 같이 외부 강관에 의해 콘크리트가 구속되어 기둥의 성능을 발휘하므로, 외부 강관의 항복 여부가 전체 기둥의 강도를 결정하게 될 것이다. 그래서 본 연구에서는 화재에 의한 기둥의 온도 변화에 따른 ICH CFT 기둥의 강도를 콘크리트의 구속효과와 재료비선형성을 고려하여 해석을 수행하였고, 또한 기둥의 중공비, 외부강관의 두께, 콘크리트의 강도를 매개 변수로 선정하여 기둥의 내화 성능을 평가하였으며, 해석에는 범용 프로그램과 전용 프로그램을 병행하여 사용하였다.

Exploring the Contributory Factors of Confined Space Accidents Using Accident Investigation Reports and Semistructured Interviews

  • Naghavi K., Zahra;Mortazavi, Seyed B.;Asilian M., Hassan;Hajizadeh, Ebrahim
    • Safety and Health at Work
    • /
    • 제10권3호
    • /
    • pp.305-313
    • /
    • 2019
  • Background: The oil and gas industry is one of the riskiest industries for confined space injuries. This study aimed to understand an overall picture of the causal factors of confined space accidents through analyzing accident reports and the use of a qualitative approach. Methods: Twenty-one fatal occupational accidents were analyzed according to the Human Factors Analysis and Classification System approach. Furthermore, thirty-three semistructured interviews were conducted with employees in different roles to capture their experiences regarding the contributory factors. The content analyses of the interview transcripts were conducted using MAXQDA software. Results: Based on accident reports, the largest proportions of causal factors (77%) were attributed to the organizational and supervisory levels, with the predominant influence of the organizational process. We identified 25 contributory factors in confined space accidents that were causal factors outside of the original Human Factors Analysis and Classification System framework. Therefore, modifications were made to deal with factors outside the organization and newly explored causal factors at the organizational level. External Influences as the fifth level considered contributory factors beyond the organization including Laws, Regulations and Standards, Government Policies, Political Influences, and Economic Status categories. Moreover, Contracting/Contract Management and Emergency Management were two extra categories identified at the organizational level. Conclusions: Preventing confined space accidents requires addressing issues from the organizational to operator level and external influences beyond the organization. The recommended modifications provide a basis for accident investigation and risk analysis, which may be applicable across a broad range of industries and accident types.

폐쇄된 계의 닫힌 회전 운동에 대한 컴퓨터 씨뮬레이션 모델에 관한 연구 (A study on the computer simulation model of the closed rotating system about the closed system)

  • 정병태
    • 한국컴퓨터산업학회논문지
    • /
    • 제8권3호
    • /
    • pp.181-186
    • /
    • 2007
  • 폐쇄된 계 내부와 외부에서 작용되는 운동에는 선형 열린 운동과 닫힌 운동이 있고 비선형 열린 운동과 닫힌 운동이 있다. 선형 닫힌 운동이 마찰과 같은 외력을 받을시 갇힌 운동이 발생된다. 회전 닫힌 운동에도 마찰과 같은 외력을 받을시 회전 갇힌 운동이 있음을 해석 한다. 회전 닫힌 운동과 갇힌 운동을 액체 실험 장치를 통하여 정량적으로 고찰하고 회전 갇힌 운동이 있음을 분석하여 회전 열린 운동, 닫힌 운동 과 갇힌 운동에 대한 컴퓨터 씨뮬레이션 수식모델을 정한다. 그리고 간단한 운동 장치의 그래픽 구조를 고려 할 수 있도록 소개한다.

  • PDF

전단스팬비 영향을 고려한 RC구속조적조 벽체의 내진성능평가 (Seismic Performance Evaluation of Confined Masonry Wall System Considering of Shear-Depth Ratio)

  • 김경태;서수연;윤승조;성기태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.1-4
    • /
    • 2005
  • To investigate the effective seismic strengthening methods for masonry walls in developing countries, a total of four confined masonry (CM) walls were constructed and tested. In order to investigate the effect of the height of application point of lateral loads and reinforcing steel bars in walls and columns for the improvement of the seismic behavior of confined concrete block masonry walls, an experimental research program is conducted. The heights of inflection point considered were 0.67 and 1.11 times the height of the wall measured from the top of foundation beam. The constant vertical axial stress applied was 0 MPa. During the test, cracking patterns, load-deflection data, and strains in reinforcement and walls in critical locations was measured. From test data, it was showed that the seismic performance of confined concrete block masonry walls was significantly affected by test variables.

  • PDF

Polynomial modeling of confined compressive strength and strain of circular concrete columns

  • Tsai, Hsing-Chih
    • Computers and Concrete
    • /
    • 제11권6호
    • /
    • pp.603-620
    • /
    • 2013
  • This paper improves genetic programming (GP) and weight genetic programming (WGP) and proposes soft-computing polynomials (SCP) for accurate prediction and visible polynomials. The proposed genetic programming system (GPS) comprises GP, WGP and SCP. To represent confined compressive strength and strain of circular concrete columns in meaningful representations, this paper conducts sensitivity analysis and applies pruning techniques. Analytical results demonstrate that all proposed models perform well in achieving good accuracy and visible formulas; notably, SCP can model problems in polynomial forms. Finally, concrete compressive strength and lateral steel ratio are identified as important to both confined compressive strength and strain of circular concrete columns. By using the suggested formulas, calculations are more accurate than those of analytical models. Moreover, a formula is applied for confined compressive strength based on current data and achieves accuracy comparable to that of neural networks.

무창자돈사의 환경요인 개선을 위한 변형환기시스템의 현장 평가 연구 (A Farm Scale Study on the Modified Ventilation System for Improving Environmental Factors in a Confined Nursery Pig Building)

  • 김헌태;고한종;김기연;서진귀구;최홍림
    • Journal of Biosystems Engineering
    • /
    • 제31권3호
    • /
    • pp.175-181
    • /
    • 2006
  • Nursery pig building is imperative to provide environmental conditions favorable to maintenance of piglet health and the efficiency of growth rate. To meet the ultimate goal, it is necessary to apply proper ventilation design and construction to a confinement livestock building. This study was conducted to investigate the performance of a modified ventilation system in terms of devised slot-inlet (modification I) and exhaust fan (modification II) to improve air change rate in a confined nursery pig building, with dimension of 5.9 m(W) ${\times}$ 12.6 m(L) ${\times}$ 2.2 m(H) in an Darby Genetic Station. The experiment was carried out in August, especially when the outdoor peak temperature were above $30^{\circ}C$ and the measured indoor environmental factors were temperature, air velocity, humidity and ammonia concentration which have been known to affect the piglet health and growth. There was no difference in indoor temperature between the original and modified ventilation systems, however the air velocity and ammonia concentration in confined nursery pig building with modified ventilation system were, in most cases, better performance than original ventilation system. Therefore, it was concluded that the slot-inlet system that kept indoor environmental factors pertinent and had an economic advantage, should be considered as a ventilation system for decreasing sensible heat from piglet in confined nursery pig building during extreme summer season.