• Title/Summary/Keyword: confidence band

Search Result 43, Processing Time 0.062 seconds

A Study on Organic Solvent Measurement Using Diffusive Sampler (확산포집기를 이용한 공기 중 유기용제 포집에 관한 연구)

  • Park, Mi Jin;Yoon, Chung Sik;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.208-223
    • /
    • 1994
  • The purpose of this study was to evaluate the efficiency of diffusive(or passive) sampler in measuring airbone organic solvents. Diffusive samplers are generally simple in construction and do not require power for operation. The efficiency of the diffusive samplers has not sufficiently been investigated in Korea. Three types of samplers were studied in this study. The sampling and analytical results by passive samplers were compared with results by charcoal tube method recommended by NIOSH(National Institute for Occupational Safty and Health). The following characteristics are identified and studied as critical to the performance passive monitors; recovery, reverse diffusion, storage stability, accuracy and precision, face velocity and humidity, n-Hexane, TCE(trichloroethylene) and toluene were used as test vapors. A dynamic vapor exposure system consisting of organic vapor generator and sampling chamber for evaluating diffusive samplers are made. The results of the study are summarized as follows. 1. NIOSH recommands that the overall accuracy of a sampling method in the range of 0.5 to 2.0 times the occupational health standard should be ${\pm}25$ percent for 95 percent confidence level. Among three types of diffusive samplers, sampler A has permeation membrane and samplers Band C have diffusive areas, samplers A and B met the criterion that overall accuracy for 95% confidence level of the samplers were within ${\pm}25$ percent of the reference value. Sampler C had overall accuracy ${\pm}9.6%$ and ${\pm}11.8%$ in hexane and TCE, respectively. The concentration of toluene was overestimated in sampler C with overall accuracy of ${\pm}43.9%$. 2. The desorption efficiencies of diffusive samplers were 96-107%. 3. There was no significant sampe loss during four weeks of storage both with and without refrigeration. 4. There was no significant reverse diffusion, when the samplers were exposure to clean air for 2 hours after sampling for 2 hours at the level of 2 TLY. 5. In case of 8 hours sampling, relative differences(RD) of concentrations between charcoal tube method and diffusive method were 15-39%, 13-46%, and 4-35% for sampler A, B and C, respectively. The performance was poor in 8 hours sampling for multiple substance monitors. 6. At high velocity(100 cm/sec), samplers B and C overestimated the concentrations of organic vapors, and sampler A with permeation membrance gave better results. 7. At 80% relative humidity, samplers showed no siginificant effect. Low humidity also did not affect the diffusive samplers.

  • PDF

Wind-driven Current in the East Sea Observed from Mini-met Drifters (기상뜰개로 관측된 동해에서의 취송류)

  • Lee, Dong-Kyu
    • Ocean and Polar Research
    • /
    • v.36 no.2
    • /
    • pp.103-110
    • /
    • 2014
  • A wind-driven current in the East Sea from Lagrangian measurements of wind and current at 15 m using MiniMet drifters was analyzed. Spectral analysis of the current from 217 pieces of a 10 day-long time series shows the dominant energy at the inertial frequency for the current at 15 m. Wind has energy peaks at a 0.2-0.5 cycles per day (cpd) frequency band. The power spectrum of the clockwise rotating component is predominant for the current and was 1.5-2 times larger than the anticlockwise rotating component for wind. Co-spectra between the wind and current show two peak frequency bands at subinertial frequency and 0.5-0.3 cpd. Coherences between the wind and current at those peak frequencies are significant with 95% confidence and phase differences were $90-100^{\circ}$. From the phase differences, the efolding depth is estimated as 17 m and this e-folding depth is smaller than the estimation by Chereskin's (1999) 25 m using a moored Acoustic Doppler Current Profiler and an anemometer installed at the surface buoy. The angle between the wind-driven current (or ageostrophic current) and wind from this study was also much larger than the global estimate by Rio and Hernandez (2003) using reanalysis wind and drifters. The possible explanation for the discrepancy comes from the fact that the current is driven by a wind of smaller length scale than 250 km but the satellite or the reanalysis products do not resolve winds of length scale smaller than 250 km. Large rms differences between Mini-Met and QuickSCAT wind on spatial lags smaller than 175 km substantiate this explanation.

Clinical outcomes and characteristics of acute myocardial infarction patients with developing fever after percutaneous coronary intervention

  • Jae-Geun Lee;Yeekyoung Ko;Joon Hyouk Choi;Jeong Rae Yoo;Misun Kim;Ki Yung Boo;Jong Wook Beom;Song-Yi Kim;Seung-Jae Joo
    • Journal of Medicine and Life Science
    • /
    • v.19 no.2
    • /
    • pp.46-56
    • /
    • 2022
  • The incidence of fever complicating percutaneous coronary intervention (PCI) is rare. However, little is known regarding the cause of fever after PCI. Therefore, this study aimed to determine the clinical characteristics of patients with acute myocardial infarction (AMI), with or without fever, after PCI. We enrolled a total of 926 AMI patients who underwent PCI. Body temperature (BT) was measured every 4 hours or 8 hours for 5 days after PCI. Patients were divided into two groups according to BT as follows: BT<37.7℃ (no-fever group) and BT ≥37.7℃ (fever group). The 2 years clinical outcomes were compared subsequently. Fever after PCI was associated with higher incidence of major adverse cardiac events (MACE) (hazard ratio [HR], 1.56; 95% confidence interval [CI], 1.07-2.28; P=0.021), all-cause death (HR, 2.32; 95% CI, 1.18-4.45; P=0.014), cardiac death (CD) (HR, 2.57; 95% CI, 1.02-6.76; P=0.049), and any revascularization (HR, 1.69; 95% CI, 1.02-2.81; P=0.044) than without fever. In women, prior chronic kidney disease, lower left ventricular (LV) ejection fraction, higher LV wall motion score index, white blood cell count, peak creatine kinase-myocardial band level, and longer PCI duration were associated with fever after PCI. Procedures such as an intra-aortic balloon pump, extracorporeal membrane oxygenation, continuous renal replacement therapy, central and arterial line insertion, and cardiopulmonary resuscitation were related to fever after PCI. Fever after PCI in patients with AMI was associated with a higher incidence of MACE, all-cause death, CD, and any revascularization at the 2 years mark than in those without fever.

Glutathione S-transferase polymorphism of neonatal hyperbilirubinemia in Korean neonates (한국인 신생아 황달과 Glutathione S-transferase 다형성에 관한 연구)

  • Kang, Chang Seok;Hong, Seung Su;Kim, Ji Sook;Kim, Eun Ryoung
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.3
    • /
    • pp.262-266
    • /
    • 2008
  • Purpose : Glutathione S-transferase (GST) is a polymorphic supergene family of detoxification enzymes that are involved in the metabolism of numerous diseases. Several allelic variants of GSTs show impaired enzyme activity and are suspected to increase the susceptibility to diseases. Bilirubin is bound efficiently by GST members. The most commonly expressed gene in the liver is GSTM1, and GSTT1 is expressed predominantly in the liver and kidneys. To ascertain the relationship between GST and neonatal hyperbilirubinemia, the distribution of the polymorphisms of GSTT1 and GSTM1 were investigated in this study. Methods : Genomic DNA was isolated from 88 patients and 186 healthy controls. The genotypes were analyzed by polymerase chain reaction (PCR). Results : The overall frequency of the GSTM1 null was lower in patients compared to controls (P=0.0187, Odds ratio (OR) =0.52, 95% confidence interval (CI), 0.31-0.88). Also, the GSTT1 null was lower in patients compared to controls (P=0.0014, OR=0.41, 95% CI=0.24-0.70). Moreover, the frequency of the null type of both, in the combination of GSTM1 and GSTT1, was significantly reduced in jaundiced patients (P=0.0008, OR=0.31, 95% CI=0.17-0.61). Conclusion : We hypothesized that GSTM1 and GSTT1 might be associated with neonatal hyperbilirubinemia. However, the GSTT1 and GSTM1 null type was reduced in patients. Therefore the null GSTT1, null GSTM1, and null type of both in the combination of GSTM1 and GSTT1 may be not a risk factor of neonatal jaundice.

Elevated Prx1 Provides Resistance to Docetaxel, But Is Not Associated with Predictive Significance in Lung Cancer

  • Hwang, Ki Eun;Park, Chul;Seol, Chang Hwan;Hwang, Yu Ri;Hwang, June Seong;Jung, Jae Wan;Choi, Keum Ha;Jeong, Eun Taik;Kim, Hak Ryul
    • Tuberculosis and Respiratory Diseases
    • /
    • v.75 no.2
    • /
    • pp.59-66
    • /
    • 2013
  • Background: This study was conducted in order to elucidate the effects of docetaxel on the growth of peroxiredoxin 1 (Prx1) knockdown A549 xenograft tumors and further tested the role of Prx1 as a predictor for how a patient would respond to docetaxel treatment. Methods: Effects of docetaxel on the growth of scrambled- and shPrx1-infected A549 xenograft tumors in nude mice were measured. Moreover, immunohistochemical expression of Prx1 was evaluated in paraffin-embedded tissues from 24 non-small cell lung cancer patients who had received docetaxel-cisplatin regimens as a first-line treatment. Results: Docetaxel treatment in Prx1 knockdown xenograft tumor resulted in reduced tumors growth compared with other groups. Prx1 knockdown increased the production of cleaved caspases-8 and -9 in the control itself compared to scramble tumors. Moreover, docetaxel treatment in Prx1 knockdown tissue led to an increased protein band. Phosphorylated Akt was found in Prx1 scramble tissues. Phosphorylated FOXO1 was detected in the docetaxel treatment group. On the other hand, Prx1 knockdown completely suppressed the Akt-FOXO1 axis. The median progression-free survival (PFS) of patients with low Prx1 expression was 7 months (95% confidence interval [CI], 6.0-7.7), whereas the median progression-free survival of patients with high Prx1 expression was 4 months (95% CI, 4.0-5.0). However, high Prx1 expression was not associated with decreased PFS (p=0.114). Conclusion: Our findings suggest that elevated Prx1 provides resistance to docetaxel treatment through suppression of FOXO1-induced apoptosis in A549 xenograft tumors, but may not be related with the predictive significance for response to docetaxel treatment.

Detection of Carnation necrotic fleck virus and Carnation ringspot virus Using RT-PCR (RT-PCR에 의한 카네이션괴저바이러스와 카네이션둥근반점바이러스 정밀진단)

  • Lee, Siwon;Kang, Eun-Ha;Heo, Noh-Yeol;Kim, Sang-Mok;Kim, Yu-Jeong;Shin, Yong-Gil
    • Research in Plant Disease
    • /
    • v.19 no.1
    • /
    • pp.36-44
    • /
    • 2013
  • Carnation is considered to be one of the top three cutting flowers in the world, which is a main crop with 21 billion annual volume of manufacture. The four carnation items such as cuttings, seed, plant and unrooted cuttings are imported and exported. Viruses can be easily transmitted during vegetative propagation of carnation. Carnation necrotic fleck virus (CNFV) and Carnation ringspot virus (CRSV) are designated as Korea plant quarantine viruses and inspected. This study was aimed to develop specific primer sets for easy and rapid detection of CNFV and CRSV. Two RT-PCR primer sets were efficiently amplified 288 and 447 bp fragments for CNFV and 503 549 bp fragments for CRSV. Furthermore, developed nested primer sets make possible to high sensitive detection and verification. CNFV nested PCR primer sets all produced band of 147 bp and CRSV nested PCR primer sets did bands of 395 and 347 bp. In addition, plasmid inserted 6 sequences in amplicon were used as a positive control to improve inspection confidence. The successful application of PCR module newly developed in this study will be highly useful for detect of CNFV and CRSV for quarantine inspections.

PRODUCT10N OF KSR-III AIRGLOW PHOTOMETERS TO MEASURE MUV AIRGLOWS OF THE UPPER ATMOSPHERE ABOVE THE KOREAN PENINSULAR (한반도 상공의 고층대기 중간 자외선 대기광 측정을 위한 KSR-III 대기광도계 제작)

  • Oh, T.H.;Park, K.C.;Kim, Y.H.;Yi, Y.;Kim, J.
    • Journal of Astronomy and Space Sciences
    • /
    • v.19 no.4
    • /
    • pp.305-318
    • /
    • 2002
  • We have constructed two flight models of airglow photometer system (AGP) to be onboard Korea Sounding Rocket-III (KSR-III) for detection of MUV dayglow above the Korean peninsular. The AGP system is designed to detect dayglow emissions of OI 2972${\AA}$, $N_2$ VK(0,6) 2780${\AA}$, $N_2$ 2PG 3150${\AA}$ and background 3070${\AA}$ toward the horizon at altitudes between 100 km and 300 km. The AGP system consists of a photometer body, a baffle an electronic control unit and a battery unit. The MUV dayglow emissions enter through a narrow band interference filter and focusing lens of the photometer, which contains an ultraviolet sensitive photomultiplier tube. The photometer is equipped with an in-flight calibration light source on a circular plane that will rotate at the rocket's apogee. A bane tube is installed at the entry of the photometer in order to block strong scattering lights from the lower atmosphere. We have carried out laboratory measurements of sensitivity and in-flight calibration light source for the AGP flight models. Although absolute sensitivities of the AGP flight models could not be determined in the country, relative sensitivities among channels are well measured so that observation data during rocket flight in the future can be analyzed with confidence.

Effect of Non-paralyzed side and Paralyzed side of Elastic Band Combined with Proprioceptive Neuromuscular Facilitation Lower Extremity Patterns on Balance in Chronic Stroke Patients (비 마비 측과 마비 측에 적용한 탄력밴드를 결합한 고유수용성 신경근 촉진법 하지패턴이 만성 뇌졸중 환자의 균형에 미치는 영향)

  • Lee, Young-Min;Ham, Min-Sik;Kim, Taek-Soo
    • PNF and Movement
    • /
    • v.13 no.4
    • /
    • pp.181-188
    • /
    • 2015
  • Purpose: This study aimed to examine the effects of proprioceptive neuromuscular facilitation (PNF) lower extremity patterns combined with elastic bands applied to stroke patients diagnosed with hemiplegia through self-training using the non-paralyzed side approach and the paralyzed side approach, and to investigate the differences in the effects. Methods: Nine chronic stroke patients who were being treated not more than twice a week at H, K, R, and C hospitals located in Gangwon-do, performed self-training for 16 minutes, two times per day for four weeks between August and October 2015. The subjects' balance ability was measured using the Tetrax stability index, the weight distribution index, the Berg Balance Scale (BBS), and the Timed Up and Go (TUG) test before the experiment and four weeks later. Among the statistical methods, paired t-tests were conducted for intra-group comparison of the measurements taken before and after the experiment, and independent t-tests were conducted for inter-group comparison of the ex post facto values. The statistical significance level was set to 0.05. Results: When the lower extremity patterns were applied to the non-paralyzed side group and the paralyzed side group, significant intra-group differences were observed for the Tetrax stability index, the weight distribution index, the Berg Balance Scale (BBS), and Timed Up and Go (TUG) tests (p<0.05); however, the inter-group comparisons showed no significant differences. Conclusion: The non-paralyzed side approach was found to be easy for patients to participate in and it also affected the patients' paralyzed side. Although the paralyzed side approach produced good exercise effects in a short period of time, it could result in adverse effects, such as a decrease in motivation and self-confidence. Therefore, these approaches are considered to be more effective when they are selectively applied depending on the purpose of the intervention and the degree of a patients' participation.

Assessing the Benefits of Incorporating Rainfall Forecasts into Monthly Flow Forecast System of Tampa Bay Water, Florida (하천 유량 예측 시스템 개선을 위한 강우 예측 자료의 적용성 평가: 플로리다 템파 지역 사례를 중심으로)

  • Hwang, Sye-Woon;Martinez, Chris;Asefa, Tirusew
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.4
    • /
    • pp.127-135
    • /
    • 2012
  • This paper introduced the flow forecast modeling system that a water management agency in west central Florida, Tampa Bay Water has been operated to forecast monthly rainfall and streamflow in the Tampa Bay region, Florida. We evaluated current 1-year monthly rainfall forecasts and flow forecasts and actual observations to investigate the benefits of incorporating rainfall forecasts into monthly flow forecast. Results for rainfall forecasts showed that the observed annual cycle of monthly rainfall was accurately reproduced by the $50^{th}$ percentile of forecasts. While observed monthly rainfall was within the $25^{th}$ and $75^{th}$ percentile of forecasts for most months, several outliers were found during the dry months especially in the dry year of 2007. The flow forecast results for the three streamflow stations (HRD, MB, and BS) indicated that while the 90 % confidence interval mostly covers the observed monthly streamflow, the $50^{th}$ percentile forecast generally overestimated observed streamflow. Especially for HRD station, observed streamflow was reproduced within $5^{th}$ and $25^{th}$ percentile of forecasts while monthly rainfall observations closely followed the $50^{th}$ percentile of rainfall forecasts. This was due to the historical variability at the station was significantly high and it resulted in a wide range of forecasts. Additionally, it was found that the forecasts for each station tend to converge after several months as the influence of the initial condition diminished. The forecast period to converge to simulation bounds was estimated by comparing the forecast results for 2006 and 2007. We found that initial conditions have influence on forecasts during the first 4-6 months, indicating that FMS forecasts should be updated at least every 4-6 months. That is, knowledge of initial condition (i.e., monthly flow observation in the last-recent month) provided no foreknowledge of the flows after 4-6 months of simulation. Based on the experimental flow forecasts using the observed rainfall data, we found that the 90 % confidence interval band for flow predictions was significantly reduced for all stations. This result evidently shows that accurate short-term rainfall forecasts could reduce the range of streamflow forecasts and improve forecast skill compared to employing the stochastic rainfall forecasts. We expect that the framework employed in this study using available observations could be used to investigate the applicability of existing hydrological and water management modeling system for use of stateof-the-art climate forecasts.

Sea Level Variability at a Synoptic Band along the East Coast of Korea and its Causal Mechanism (한국 동해연안의 종관주기 해수면 변동 특성과 발생원인)

  • Jung, Sung-Yun;Yun, Jae-Yul;Park, Tae-Wook;Lim, Se-Han;Oh, Im-Sang
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.13 no.2
    • /
    • pp.89-105
    • /
    • 2008
  • Sea level and atmospheric pressure data of 1999-2005 from four stations along the Korean east coast were analyzed to understand the sea level variability and its causal mechanism. The results of the wavelet and the auto-spectrum analyses indicate that the sea level fluctuations of 3-17 day period are statistically significant at the 95% confidence level, especially in spring to early summer. In this period, the coherency between the sea levels and the atmospheric pressures in a cross-spectrum is high, implying the importance of an inverted barometric effect in generation of the sea level fluctuations. To learn about the sea level variability, the cross-spectrum analyses were applied between the sea levels of the adjacent stations. The results show a case of southward phase propagations along the coast, as in 1999, 2003 and 2005, and an another case of no progressive phase lags between the stations, as in 2000-2002, and 2004. The phase speed in the former case is 12-15 m/s, which is a commonly observed phase speed of coastal Kelvin waves. Generation of such fluctuations seems to be related to low pressure cells developed in the Asian continent in spring and summer and moving eastward over the coastal region north of the stations. The latter case of no progressive phase lag, however, occurs when the low pressure cells developed in the continent move along the region south of the stations. In this case, the northeastward phase propagation with a speed of 5-8 m/s is observed along the southwestern coast of Japan.