• 제목/요약/키워드: cone-type friction pendulum bearing

검색결과 4건 처리시간 0.02초

진동대실험을 통한 원추형 마찰진자베어링의 내진성능 평가 (Seismic Performance Evaluation of Cone-type Friction Pendulum Bearing System Using Shaking Table Test)

  • 전법규;장성진;김남식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 춘계학술대회 논문집
    • /
    • pp.389-394
    • /
    • 2011
  • Existing FPS(Friction Pendulum System) is isolation system which is possible to isolate structures by pendulum characteristic from ground vibration. Structural natural frequency could be decided by designing the radius of curvature of FPS. Thus, response vibration could be reduced by changing natural frequency of structures from FPS. But effective periods of recorded seismic wave were various and estimation of earthquake characteristic could be difficult. If effective periods of seismic wave correspond to natural frequency of structures with FPS, resonance can be occurred. Therefore, CFPBS(Cone-type Friction Pendulum Bearing System) was developed for controlling the response acceleration and displacement by the slope of friction surfaces. Structural natural frequency with CFPBS can be changed according to position of ball on the friction surface which was designed cone-type. Therefore, Divergence of response could be controlled by CFPBS which had constantly changing natural frequency with low modal participation factor in wide-range. In this study, Seismic performance of CFPBS was evaluated by numerical analysis and shaking table test.

  • PDF

진동대실험을 통한 원추형 마찰진자베어링의 내진성능 평가 (Seismic Performance Evaluation of Cone-type Friction Pendulum Bearing System Using Shaking Table Test)

  • 전법규;장성진;김남식
    • 한국소음진동공학회논문집
    • /
    • 제21권7호
    • /
    • pp.599-608
    • /
    • 2011
  • FPS(friction pendulum system) is an isolation system which is possible to isolate structures from earthquake by pendulum characteristic. Natural frequencies of the structures could be determined by designing the radius of curvature of FPS. Thus, response vibration could be reduced by changing natural frequency of structures from FPS. But effective periods of recorded seismic wave were various and estimation of earthquake characteristic could be difficult. If effective periods of seismic wave correspond to natural frequency of structures with FPS, resonance can be occurred. Therefore, CFPBS(cone-type friction pendulum bearing system) was developed for controlling the acceleration and displacement of structure by the slope of friction surfaces. Structural natural frequency with CFPBS can be changed according to position of ball on the friction surface which was designed cone-type. Therefore, superstructures on CFPBS could be isolated from earthquake. In this study, seismic performance of CFPBS was evaluated by numerical analysis and shaking table test.

Base isolation performance of a cone-type friction pendulum bearing system

  • Jeon, Bub-Gyu;Chang, Sung-Jin;Kim, Sung-Wan;Kim, Nam-Sik
    • Structural Engineering and Mechanics
    • /
    • 제53권2호
    • /
    • pp.227-248
    • /
    • 2015
  • A CFPBS (Cone-type Friction Pendulum Bearing System) was developed to control the acceleration delivered to a structure to prevent the damage and degradation of critical communication equipment during earthquakes. This study evaluated the isolation performance of the CFPBS by numerical analysis. The CFPBS was manufactured in the shape of a cone differenced with the existing FPS (Friction Pendulum System), and a pattern was engraved on the friction surface. The natural frequencies of the CFPBS were evaluated from a free-vibration test with a seismic isolator system consisting of 4 CFPBS. To confirm the earthquake-resistant performance, a numerical analysis program was prepared using the equation of the CFPBS induced from the equations of motion. The equation reported by Tsai for the rolling-type seismic isolation bearings was proposed to design the equation of the CFPBS. Artificial seismic waves that satisfy the maximum earthquake scale of the Korean Building Code-Structural (KBC-2005) were created and verified to review the earthquake-resistant performance of the CFPBS by numerical analysis. The superstructural mass of the CFPBS and the skew angle of friction surface were considered for numerical analysis with El Centro NS, Kobe NS and artificial seismic waves. The CFPBS isolation performance evaluation was based on the numerical analysis results, and comparative analysis was performed between the results from numerical analysis and simplified theoretical equation under the same conditions. The validity of numerical analysis was verified from the shaking table test.

원추형 마찰진자베어링의 내진성능평가 (Seismic Performance Evaluation of a Cone-type Friction Pendulum Bearing System)

  • 전법규;장성진;박경록;김남식;정득영
    • 한국지진공학회논문집
    • /
    • 제15권2호
    • /
    • pp.23-33
    • /
    • 2011
  • 본 연구에서는 중요 통신장비의 지진발생시 파손 및 성능저하를 방지하기 위하여 구조물로 전달되는 가속도를 조절할 수 있는 CFPBS(Cone-type Friction Pendulum Bearing System:원추형 마찰진자베어링)를 개발하고 내진성능을 검증하였다. CFPBS는 기존의 FPS(Friction Pendulum System)와 다르게 원추형으로 제작되었으며 보다 큰 마찰력을 얻기 위하여 마찰면에 패턴을 음각하였다. CFPBS의 고유성능을 파악하기 위하여 4개의 CFPBS가 하나의 개체를 이루도록 제작된 지진격리장치를 이용하여 자유진동시험을 수행하였다. 운동방정식으로부터 유도된 CFPBS의 이론식과 Newmark-${\beta}$ Method를 이용하여 내진성능을 검증하기위한 MATLAB7.0 기반의 동적 수치해석프로그램을 제작하였으며 CFPBS의 제작 시 원하는 성능을 발휘할 수 있도록 간략화된 CFPBS의 설계식을 제안하였다. 수치해석을 통한 CFPBS의 내진성능평가를 위하여 건축구조설계기준(KBC-2005)의 최대지진규모에 해당하는 인공지진파를 생성하고 검증하였다. El Centro NS(1940)와 Kobe NS(1995), 인공지진파 등을 사용하여 CFPBS의 상부질량과 경사각을 매개변수로 하는 수치해석을 수행하였다. 수치해석의 결과를 토대로 CFPBS의 내진성능을 평가하였으며 수치해석의 결과와 설계식을 이용하여 동일한 조건에서 얻어진 결과를 비교분석하였다.