• Title/Summary/Keyword: cone-beam 전산화단층촬영

Search Result 45, Processing Time 0.016 seconds

EFFECTIVE DOSE FROM CONE BEAM CT FOR IMAGING OF MESIODENS (상악 정중과잉치 진단을 위한 cone beam CT의 유효선량)

  • Han, Won-Jeong;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.3
    • /
    • pp.273-279
    • /
    • 2012
  • Purpose : This study was aimed to calculate effective dose from cone beam CT and compare effective dose from periapical and panoramic radiography for mesiodens. Materials and Methods : Upper anteiror periapical, panoramic radiography and cone-beam CT were taken for diagnosis of mesiodens. The effective dose were calculated by using an anthropomorphic phantom loaded with thermoluminescent dosimeters at the 23 sites related to sensitive organs. Results : The highest absorbed doses were received by the mandibular body, parotid gland and cheek from periapical, panoramic and cone-beam CT, respectively. The effective doses for periapical, panoramic radiography and cone-beam CT measured 2, 18 and 48 ${\mu}Sv$. Conclusion : Cone-beam CT, although providing additional diagnostic benefits, exposes patients to higher levels of radiation than conventional periapical and panoramic radiography.

Analysis of Image Distortion by Mandibular Arch Form in Cone Beam CT and Panoramic Image (Cone Beam형 CT와 파노라마 영상에서 하악궁의 영상 왜곡 분석)

  • Jeong, Cheonsoo;Lee, Geeheun
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.4
    • /
    • pp.301-305
    • /
    • 2013
  • This thesis intends to analyze tooth distortion by mandibular arch form by reproducing existing panorama image and reconstructed panorama image of Cone Beam CT data with the three-dimensional computer program. The diameter of tooth measured in Cone Beam CT's cross-section image and reconstructed panorama was synchronized without any big change from incisors to posteriors. But, panorama showed serious distortion as going to posteriors after showing a little distortion in incisors. The panorama reconstructed for patients' individual arch showed reduced distortion than panoramas used generally. In addition, panorama showed serious distortion from incisors to posteriors and it means that distortion is reduced in reconstructed panorama.

Evaluation of Bonwill triangle using cone beam computerized tomography in Korean (콘빔형 전산화단층영상을 이용한 한국인의 본윌 삼각에 대한 평가)

  • Kong, Hyun-Jun;Oh, Sang-Chun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.97-103
    • /
    • 2018
  • Purpose: The aim of this study was to evaluate the Bonwill triangle of Korean using the cone beam computerized tomography (Cone-beam CT). Materials and Methods: 120 Koreans (60 males and 60 females) who visited Daejeon Dental College Hospital of Wonkwang University and who underwent the Cone-beam CT were selected. The Cone-beam CT images were analysed with Invivo 5.1 (Anatomage, San Jose, USA). After reorientation of axis, the intercondylar distance was measured by clicking both middle points of condyle. And the condyle-incisor distance was measured by clicking the middle point of condyle and contact point of the mandibular central incisor's incisal edge. The collected data were analysed using the SPSS Version 23.0 (IBM Inc., Armonk, USA) and statistical significance was verified by gender using independent t-test. Results: The mean intercondylar distance of Korean was 105.9 mm, and the male (108.3 mm) was statistically significantly larger than the female (103.4 mm). The mean condyle-incisor distance of Korean was 105.2 mm, and the male (108.1 mm) was statistically significantly larger than the female (102.3 mm). Conclusion: The mean intercondylar distance of Korean in this study was 105.9 mm that was smaller than well-known 110 mm of Caucasian and the male was statistically significantly larger than the female. Within the limitations of this study, it would be necessary to use the articulator which can adjust the intercondylar distance according to the individual for prosthodontic treatment of Korean.

Morphological Analysis of the Sinus Lateral Wall Using Cone-Beam Computed Tomography (콘빔형 전산화단층영상을 이용한 상악동 측벽의 형태학적 분석)

  • An, Seo-Young;Kim, Yong-Gun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.4
    • /
    • pp.349-357
    • /
    • 2012
  • The purpose of this study was to measure the thickness of the sinus lateral wall using cone-beam computed tomography (CBCT), and to find the most suitable vertical position for lateral window opening prior to sinus elevation. Fifty three patients requiring sinus elevation had CBCT scans acquired by CB MercuRay (Hitachi, Medico, Tokyo, Japan) from July, 2010 to June, 2012. The thickness of the sinus lateral wall was measured according to its vertical position against the sinus inferior border (SIB), and its mean was calculated through two repeated measurements. The thickness of the sinus lateral wall was more than 2 mm at 2 mm above the sinus inferior border (SIB+2), however, it was less than 2 mm at 3 mm above the sinus inferior border (SIB+3). In conclusion, it is recommended that the inferior border of lateral wall window be made 3 mm above the sinus inferior border during sinus elevation using the lateral approach considering the thickness of the sinus lateral wall.

The Usefulness of Cone Beam Computed Tomography in Diagnosis of Temporomandibular Joint Osteoarthritis (측두하악관절 골관절염 환자의 진단에서 Cone Beam 전산화 단층촬영의 유용성)

  • Roh, Chang-Se;Jung, Yun-Hoa;Tae, Il-Ho;Ko, Myung-Yun;Ahn, Yong-Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.1
    • /
    • pp.81-90
    • /
    • 2009
  • This study is designed to assess Relationship between clinical diagnosis of Temporomandibular Joint Disorder and diagnostic finding of Cone Beam Computed Tomography(CBCT) The author performed clinical examination for TMD Patients who visited Orofacial pain clinic, Jin-ju ooo Dental office. CBCT(Cone beam computed tomography) was taken for 190 joints in 95 subjects. A Oral medicine and Oral radiologist evaluated CBCT each other. then we compared with that result, Condyle bony changes were classified by no bone change, flattening, erosion and osteophyte. The obtained results were as follow: 1. The Kappa index of the diagnosis between oral medicine and oral radiogist were high, the index of diagnosis by degenerative joint disease were more higher. 2. The Kappa index of panoramic view and CBCT was low, more condylar bone chages were observed by CBCT diagnosis 3. Condylar bone changes of the 54.2% of non-DJD group clinicaly was observed by CBCT diagnosis and no bone changes of the 15.3% of DJD group.was observed by CBCT 4. TMJ pain was associated with erosion of condyle bone change of TMJ. Crepitation and longest duration of TMD were associated with osteophytic bone change.

THE EVALUATION OF THE PATIENTS TAKING CBCT IN DEPARTMENT OF PEDIATRIC DENTISTRY (소아치과에서 Cone beam형 전산화단층영상을 이용한 환자의 평가)

  • Jeon, Hye-Jin;Yang, Yeon-Mi;Kim, Jae-Gon;Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.3
    • /
    • pp.249-256
    • /
    • 2012
  • Cone beam computed tomography (CBCT) has become widely available in recent years and is recognized as an important diagnostic tool for varies disease and condition of the orofacial structure. Clinician is easy to determine adequate treatment plan for pediatric patients by using CBCT. CBCT is used in Chonbuk National University Dental Hospital since 2005. This research presents clinical application of CBCT on patients visiting department of pediatric dentistry in Chonbuk National University Dental Hospital from Jan, 2005 to July, 2011. 1. Total number of patients taken CBCT is 252, and total number of area taken CBCT is 279. 2. An age group form 9 years to 12 years showing 53% was highest and percentage of 6~8 years showed 24%. 3. Chief complaints for CBCT taking are position and shape of impacted teeth (49.1%), mesiodens (19.4%), supernumerary teeth (7.9%), position and root canal shape of erupting teeth (7.2%), cyst (5.4%), inflammatory lesion (3.9%), odontoma (3.9%), tumor (2.2%), and et al. 4. Treatments are extraction (29.7%), orthodontic traction and leveling (24.0%), follow up (16.5%), refer to other professional part (11.5%), endodontic treatment (3.9%), surgical removal (2.9%), malsupialization (3.9%), enucleation (1.1%), and fail to follow up (5.0%), and et al.

Radiologic Diagnosis of Temporomandibular Joint (측두하악관절의 영상진단)

  • Park, Hyok;Chung, A-Young;Jung, Da-Woon;Kim, Seong-Taek
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.3
    • /
    • pp.291-299
    • /
    • 2012
  • There are many kinds of techniques for imaging temporomandibular joints. None of them for imaging "best fit" for every patient of temporomandibular disorder is recommended ideally. It is more important to be able to select the modality that is most adequate and appropriate for a given clinical issue.

Digital approach integrating 3D facial scan and a virtual mockup for esthetic restorative treatment: A case report (심미보철 수복을 위한 3차원 안면스캔과 가상 보철물 시각화를 이용한 디지털 치료 증례)

  • Mai, Hai Yen;Choi, Yong-Do;Lee, Du-Hyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.425-431
    • /
    • 2019
  • This clinical case report describes the digital workflow that combines a face scan, cone beam computed tomography and an intraoral scan to visualize the outcome of prosthodontic treatment in the anterior region. This approach improves communication between clinic, laboratory and patients. A patient with healthy general condition came for a restorative treatment to treat post-traumatic central incisors of maxilla. A virtual patient replica was made by incorporating a face scan, cone beam computed tomography and an intraoral scan. Design mockup of definitive restorations was shown to the patient and modified according to the patient's desire. This digital workflow facilitates the fabrication of optimal esthetic restorations, and enhances the predictability of outcome of restorations.

Evaluation of interdental distance of natural teeth with cone-beam computerized tomography (콘빔형 전산화단층영상을 이용한 자연치 치간거리의 평가)

  • Oh, Sang-Chun;Kong, Hyun-Jun;Lee, Wan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.278-283
    • /
    • 2017
  • Purpose: The aim of this study was to evaluate the interdental distances of anterior, premolar, and molar teeth at the cementoenamel junction (CEJ) and 2 mm below the CEJ in healthy natural dentition with cone-beam computerized tomography (cone-beam CT) in order to provide valuable data for ideal implant positioning relative to mesiodistal bone dimensions. Materials and Methods: Two hundred patients who visited Dental Hospital, Wonkwang University, who had natural dentition with healthy interdental papillae, and who underwent cone-beam CT were selected. The cone-beam CT images were converted to digital imaging and communication in medicine (DICOM) files and reconstructed in three-dimensional images. To standardize the cone-beam CT images, head reorientation was performed. All of the measurements were determined on the reconstructed panoramic images by three professionally trained dentists. Results: At the CEJ, the mean maxillary interdental distances were 1.84 mm (anterior teeth), 2.07 mm (premolar), and 2.08 mm (molar), and the mean mandibular interproximal distances were 1.55 mm (anterior teeth), 2.20 mm (premolar), and 2.36 mm (molar). At 2mm below the CEJ, the mean maxillary interdental distances were 2.19 mm (anterior teeth), 2.51 mm (premolar), and 2.60 mm (molar), and the mean mandibular interproximal distances were 1.86 mm (anterior teeth), 2.53 mm (premolar), and 3.01 mm (molar). Conclusion: The interdental distances in the natural dentition were larger at the posterior teeth than at the anterior teeth and also at 2 mm below the CEJ level compared with at the CEJ level. The distances between mandibular incisors were the narrowest and the distances between mandibular molars were the widest in the entire dentition.

Evaluation of Dose Reduction and Maintaining Image Quality according to Exposure Factors of Cone Beam Computed Tomography (콘빔전산화단층촬영에서 노출 조건에 따른 화질 유지 및 선량 감소에 대한 평가)

  • Han, Jin-Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.353-360
    • /
    • 2020
  • This research aims at suggesting exposure condition that shows maintaining the value of the physical image quality factor by decreasing tube voltage and tube current from the standard exposure condition(80 kV, 7 mA) of a CBCT apparatus. To measure the value of the physical image quality factor, modular transfer function(MTF) was analyzed and dose-area product(DAP) was used for the measurement of exposure dose. CBCT images of a Sedentex IQ phantom were obtained under 15 exposure conditions of different combination of tube voltage(80, 78, 76 kV) and tube current(7, 6, 5, 4, 3 mA) and MTF 10 was calculated under each exposure conditions. There were no significant differences in MTF 10 under 80 kV-6 mA, 80 kV-5 mA exposure conditions in comparison with standard exposure condition. Based on the results of this research, 80 kV-5 mA condition are expected to be able to reduce exposure dose with maintaining the value of the physical image quality factor of the standard exposure condition.