• 제목/요약/키워드: cone base

검색결과 94건 처리시간 0.023초

A New Species of Leptostrobus from the Upper Triassic Amisan Formation of the Nampo Group in Korea

  • Kim, Jong-Heon;Kim, Hee-Soo;Lee, Bong-Jae;Kim, Jung-Min;Lee, Hee-Kwon
    • 한국지구과학회지
    • /
    • 제23권1호
    • /
    • pp.30-37
    • /
    • 2002
  • Leptostrobus myeongamensis sp. nov. is newly described from the well-preserved but broken material occurring in the Upper Triassic Amisan Formation of the Nampo Group in Korea. This species is characterized by its lateral appendages of cone axis, each consisting of a rounded capsule and small scale leaf, and by its cone base covered with small scale leaves, the same size as in cone axis. This species is the first record from the Mesozoic strata in Korea.

Computation of aerodynamic coefficients of a re-entry vehicle at Mach 6

  • R.C. Mehta;E. Rathakrishnan
    • Advances in aircraft and spacecraft science
    • /
    • 제10권5호
    • /
    • pp.457-471
    • /
    • 2023
  • The paper evaluates the aerodynamic coefficients on a blunt-nose re-entry capsule with a conical cross-section followed by a cone-flare body. A computer code is developed to solve three-dimensional compressible inviscid equationsfor flow over a Space Recovery Experiment (SRE) configuration at different flare-cone half-angle at Mach 6 and angle of attack up to 5°, at 1° interval. The surface pressure variation is numerically integrated to obtain the aerodynamic forces and pitching moment. The numerical analysis reveals the influence of flare-cone geometry on the flow characteristics and aerodynamic coefficients. The numerical results agree with wind tunnel results. Increase of cone-flare angle from 25° to 35° results in increase of normal force slope, axial forebody drag, base drag and location of centre of pressure by 62.5%, 56.2% and 33.13%, respectively, from the basic configuration ofthe SRE of 25°.

상용해석 툴을 이용한 소형 스크류 디캔터의 설계에 관한 연구 (A Study on Design of Small Type Screw Decanter using Commercial Analysis Tool)

  • 김용석;김종태;양순용
    • 드라이브 ㆍ 컨트롤
    • /
    • 제11권4호
    • /
    • pp.46-52
    • /
    • 2014
  • This study suggests a small-sized screw decanter specialized for dredging sites. Generally, conventional screw decanters are composed of a cylinder and a cone. However, the suggested screw decanter simply has a cone based on a cone-type bowl structure. In this research, a commercial analysis tool is used to establish an optimal design for the bowl and the screw conveyor. Moreover, the base frame, where the main bearings that support the spindle of the bowl and the screw conveyor are installed, is optimally designed considering the weight of the rotating body and the deflection caused by the high centrifugal force. Furthermore, the natural frequency range of the spinning body, the bowl and the screw conveyor, is applied to this base frame; it is designed not to correspond to the resonance frequency range and achieves stability as a result. This study suggests an optimal design for the rotating body and the base frame of a screw decanter considering its vibration characteristics. Such a design will prevent overuse of materials and help to reduce the weight and volume-and the price-of a screw decanter.

유한체적법에 의한 로켓플룸 저부가열의 열복사 모델 (Thermal radiation model for rocket plume base heating using the finite-volume method)

  • 김만영;백승욱
    • 대한기계학회논문집B
    • /
    • 제20권11호
    • /
    • pp.3598-3606
    • /
    • 1996
  • The finite volume method for radiation is applied to investigate a radiative heating of rocket base plane due to searchlight and plume emissions. Exhaust plume is assumed to absorb, emit and scatter the radiant energy isotropically as well as anisotropically, while the medium between plume boundary and base plane is cold and nonparticipating. Scattering phase function is modelled by a finite series of Legendre polynomials. After validating benchmark solution by comparison with that of previous works obtained by the Monte-Carlo method, further investigations have been done by changing such various parameters as plume cone angle, scattering albedo, scattering phase function, optical radius and nozzle exit temperature. The results show that the base plane is predominantly heated by the plume emission rather than the searchlight emission when the nozzle exit temperature is the same as that of plume.

Evaluation of morphometric features of fossa navicularis using cone-beam computed tomography in a Turkish subpopulation

  • Magat, Guldane
    • Imaging Science in Dentistry
    • /
    • 제49권3호
    • /
    • pp.209-212
    • /
    • 2019
  • Purpose: Fossa navicularis is a bone defect in the clivus. Familiarity with this anatomical variant is important because it is close to vital anatomical structures in the base of the skull. The aim of this study was to determine the prevalence and morphometric properties of fossa navicularis within the clivus in a Turkish subpopulation using cone-beam computed tomography (CBCT). Materials and Methods: A total of 168 CBCT scans (female: 96, male: 71) were evaluated. High-quality CBCT images of patients without a syndromic condition or a history of neurological disease or surgery were included in the study. The prevalence, depth, length, and width of the fossa navicularis were performed. Results: The prevalence of fossa navicularis was 27.5% (n=46 patients). Sex was not associated with the depth, length, or width of the fossa navicularis (P>0.05). A significant positive correlation was found between age and length of the fossa navicularis(P>0.05). Conclusion: Fossa navicularis was found to be rare (27.5%). Anatomical variants of the skull base can also be clearly identified on CBCT images. The results of this study may be useful to radiologists, anatomists, and surgeons interested in the skull base.

Arrested pneumatization of the sphenoid sinus mimicking intraosseous lesions of the skull base

  • Jalali, Elnaz;Tadinada, Aditya
    • Imaging Science in Dentistry
    • /
    • 제45권1호
    • /
    • pp.67-72
    • /
    • 2015
  • Arrested pneumatization of the sphenoid sinus is a developmental variant that is not always well recognized and is often confused with other pathologies associated with the skull base. This report describes the case of a patient referred for cone-beam computed tomography (CBCT) imaging for dental implant therapy. CBCT demonstrated a well-defined incidental lesion in the left sphenoid sinus with soft tissue-like density and sclerotic borders with internal curvilinear opacifications. The differential diagnoses included intraosseous lipoma, arrested pneumatization of the sphenoid sinus, chondrosarcoma, chondroid chordoma, and ossifying fibroma. The radiographic diagnosis of arrested pneumatization was based on the location of the lesion, its well-defined nature, the presence of internal opacifications, and lack of expansion. Gray-scale CBCT imaging of the area demonstrated values similar to fatty tissue. This case highlighted the fact that benign developmental variants associated with the skull base share similar radiographic features with more serious pathological entities.

매립지반의 팽이말뚝 평판재하시험 사례 연구 (Case Study Top-Base Foundation Static Loading Test in Reclaimed Land)

  • 신은철;김성환;이애영
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.721-728
    • /
    • 2008
  • Top-Base Method is a stabilization method for light weight structures particularly in the soft ground. It is widely used for the increment of bearing capacity and the effect of restraining settlement when the bearing capacity of the ground is not enough. Top-shaped cone concrete foundations are installed in graveled laid over soft ground. The principle of the basic method is to maximize effect of dispersing the overburden pressure by increasing the contact area of the top-shaped cone. Therefore, the bearing capacity is increased and the settlement is decreased by the embedded resistance of pile part in the ground. In this paper, the plate bearing test was conducted to evaluate the feasibility of Top-Base foundation. Based on the test results, the coefficient of subgrade reaction, elastic modulus, and settlement of foundation on reclaimed land was derived.

  • PDF

텍사스 콘 관입시험을 이용한 IGM에 근입된 현장타설말뚝의 설계 (Design of IGM Socketed Drilled Shafts Using Texas Cone Penetrometer Tests)

  • 남문석
    • 한국지반공학회논문집
    • /
    • 제22권10호
    • /
    • pp.55-67
    • /
    • 2006
  • IGM(Intermediate Geomaterial)에 근입된 현장타설말뚝의 설계를 수행하기 위해서는 대상 지반의 강도특성을 알아야 하고, 이를 위해 IGM에 대한 일축이나 삼축 등의 압축강도시험을 수행한다. 그러나, 설계 대상의 IGM지반이 풍화가 된 경우에는 압축강도시험을 통한 강도특성 파악이 힘들다. 이러한 경우에는 압축강도시험을 대체하여 IGM지반의 강도 특성을 파악할 수 있는 방법들이 필요로 한다. 본 연구에서는 현재 텍사스주 도로국(Texas Department of Transportation)에서 말뚝기초의 설계인자로서 사용 중인 텍사스 콘 관입시험(Texas Cone Penetrometer Test)을 이용하여 IGM지반의 역학특성을 파악하였다. 그리고 미국의 텍사스주 지역에 분포하는 IGM지반인 셰일(Clay Shale)과 석회암(Limestone)을 대상으로 시험현장을 선택하였고 말뚝재하시험과 텍사스 콘 관입시험을 수행하였다. 본 연구결과를 바탕으로 텍사스 콘 관입시험과 IGM 근입 현장타설말뚝의 주면마찰력과 선단지지력과의 상관관계를 제시하였다.

Evaluation of canalis basilaris medianus using cone-beam computed tomography

  • Syed, Ali Z.;Zahedpasha, Samir;Rathore, Sonali A.;Mupparapu, Mel
    • Imaging Science in Dentistry
    • /
    • 제46권2호
    • /
    • pp.141-144
    • /
    • 2016
  • The aim of this report is to present two cases of canalis basilaris medianus as identified on cone-beam computed tomography (CBCT) in the base of the skull. The CBCT data sets were sent for radiographic consultation. In both cases, multi-planar views revealed an osseous defect in the base of the skull in the clivus region, the sagittal view showed a unilateral, well-defined, non-corticated, track-like low-attenuation osseous defect in the clivus. The appearance of the defect was highly reminiscent of a fracture of the clivus. The borders of osseous defect were smooth, and no other radiographic signs suggestive of osteolytic destructive processes were noted. Based on the overall radiographic examination, a radiographic impression of canalis basilaris medianus was made. Canalis basilaris medianus is a rare anatomical variant and is generally observed on the clivus. Due to its potential association with meningitis, it should be recognized and reported to avoid potential complications.

플라즈마 반응기구조에 따른 코로나방전 및 NO-NO$_2$ 전환특성에 관한 실험적 연구 (Experimental Study on the Effect of Plasma Reactor Type on Corona Discharge and NO-NO2 Conversion Characteristics)

  • 박용성;전광민
    • 한국자동차공학회논문집
    • /
    • 제10권6호
    • /
    • pp.65-71
    • /
    • 2002
  • Characteristics of corona discharge of the different types of the plasma reactors which are cone-hole and cone-plate is investigated experimentally. The discharge starts at lower voltage for the cathode corona than the anode corona and spark occurs at higher voltage for the cathode corona. And the cathode corona makes more stable discharge than the anode corona. The effect of the base gas in corona discharge for different O$_2$/N$_2$ concentrations is related with the gas molecular weight. The discharge for the smaller molecular weight gas occurs easier than for the high molecular weight gas. The discharge current decreases with the increase of oxygen concentration and it increases more sharply for anode corona than for cathode corona as discharge voltage increases after corona onset voltage. NO-NO$_2$ conversion increases with the energy density of corona discharge and the addition of O$_2$ in a base N$_2$ gas.