Measuring Thermal Conductivity of Nanofluids and Heat Transfer Enhancement (나노유체의 열전도율 측정과 열전달 향상)

  • Lee, Shin-Pyo;Choi, Cheol;Oh, Je-Myung
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.147-150
    • /
    • 2006
  • A new class of heat transfer fluid with higher thermal conductivity, called nanofluids has been developed by Dr. S. Choi about decade ago. Many exciting experimental and theoretical results have been reported worldwide to predict the thermal conductivity enhancement of nanofluids, however, they sometimes show excessive large discrepancies between each other. This kind of disagreements in thermal conductivity data is partly ascribable to the accuracy of the measuring apparatus, that is, mostly used THM(transient hot-wire method). New thermal conductivity measuring method whose principle is different from that of conventional THM is proposed in this article and measurements and uncertainty analysis were made for the three nanofluid samples with different particle concentration of pure, 2% and 4% of AlN nanofluids.

  • PDF

Experimental Study on Thermal Conductivity and Viscosity of Grouts for Backfilling Ground Heat Exchanger (수직 밀페형 지증 열교환기용 뒤채움재의 열전도 및 점도특성 연구)

  • Choi, Hang-Seok;Lee, Chul-Ho;Gil, Hu-Jeong;Choi, Hyo-Pum;Woo, Sang-Baik
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.529-532
    • /
    • 2007
  • In order to characterize the thermal conductivity and viscosity of grout materials used for backfilling ground heat exchangers, nine bentonite grouts and cement grouts being adapted in the United State have been considered in this study. The bentonite grouts indicate that the thermal conductivity and viscosity increase with the content of bentonite or filler (silica sand). In addition, material segregation can be observed when the viscosity of grout is relatively low. The saturated cement grouts appear to possess much higher thermal conductivity than the saturated bentonite grouts, and the reduction of thermal conductivity in the cement grouts after drying specimens is less than in case of the bentonite grouts. Maintaining the moisture content of grouts is a crucial factor in enhancing the efficiency of ground heat exchangers.

  • PDF

Electric Conductivities of LaCl3-KCl Binary Melts (용융 LaCl3-KCl 2성분계 혼합염의 전기전도도)

  • Kim, Kiho
    • Journal of the Korean institute of surface engineering
    • /
    • v.47 no.1
    • /
    • pp.48-52
    • /
    • 2014
  • Electric conductivities of $LaCl_3$-KCl binary melts have been measured by the Kohlausch bridge method over the range from their liquidus temperatures to about 1280 K. The electric conductivity increased with the content of KCl for all over the composition range of binary melts. The composition dependence of the electric conductivity and molar conductivity for the binary melt showed a non-linear relation from the additivity line, and the deviation showed a maximum value at about 60 mol.% KCl. The deviation implies the existence of complex ion of $LaCl^{4-}$ in the melt. Activation energy for electric conductivity of the binary melts decreased monotonously with increasing content of KCl.

Spatial analysis and ranges of thermal conductivity of rocks (국내 암석 열전도도 범위와 공간적인 분포)

  • Shim, Byoung-Ohan;Park, Jeong-Min;Baek, Seung-Gyun;Kim, Hyoung-Chan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.555-555
    • /
    • 2009
  • A web GIS based database system of thermophysical property of rocks in Korea is under construction. Rock samples were randomly collected over the whole country and sample spacings were generally 1 to 10 km. Thermal diffusivity, spedific heat, thermal conductivity, specific heat, density and porosity were measured on a collection of 1,560 rock samples in the laboratory. The sampled rocks were classified into igneous, metamorphic and sedimentary rock types and the variables were statistically studied. The thermal conductivity were compared with thermal diffusivity, porosity and dry density to define any correlations and the distribution of thermal conductivity is characterized by the geostatistical analysis. The optimal mapping of thermal conductivity is very useful as a practical design component for any geothermal systems.

  • PDF

Viscosity and thermal conductivity of copper oxide nanofluid dispersed in ethylene glycol

  • Kwak, Ki-Yuel;Kim, Chong-Youp
    • Korea-Australia Rheology Journal
    • /
    • v.17 no.2
    • /
    • pp.35-40
    • /
    • 2005
  • Nanofluid is a novel heat transfer fluid prepared by dispersing nanometer-sized solid particles in traditional heat transfer fluid to increase thermal conductivity and heat transfer performance. In this research we have considered the rheological properties of nanofluids made of CuO particles of 10-30nm in length and ethylene glycol in conjunction with the thermal conductivity enhancement. When examined using TEM, individual CuO particles have the shape of prolate spheroid of the aspect ratio of 3 and most of the particles are under aggregated states even after sonication for a prolonged period. From the rheological property it has been found that the volume fraction at the dilute limit is 0.002, which is much smaller than the value based on the shape and size of individual particles due to aggregation of particles. At the semi-dilute regime, the zero shear viscosity follows the Doi-Edwards theory on rodlike particles. The thermal conductivity measurement shows that substantial enhancement in thermal conductivity with respect to particle concentration is attainable only when particle concentration is below the dilute limit.

입도분석과 현장수리시험에 의한 수리전도도의 특성 비교

  • Ham Se-Yeong;Jeong Jae-Yeol;Lee Jeong-Hwan;Kim Hyeong-Su;Han Jeong-Sang
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.446-450
    • /
    • 2005
  • Hydraulic conductivity of unconsolidated media can be determined by aquifer tests, laboratory tests and empirical equations based on grain size analysis. Commonly, the different methods give different hydraulic conductivities. Grain size measurements were done to determine hydraulic conductivity, using 184 soil samples collected from eight boreholes in a riverbank filtration area, Daesan-Myeon, Changwon City, Korea, Pumping tests were conducted at the riverbank filtration area. The average hydraulic conductivity by the empirical relations from grain size measurements comes out around $10^{-2}m/s$, 22 to 55 times higher than by the pumping test analyses. The hydraulic conductivity obtained from the empirical equations is interpreted to have a relationship with steady-state condition while that obtained from the pumping tests is interpreted to have a relationship with unsteady-state condition. Thus, hydraulic conductivity obtained from various methods should be critically analyzed for reasonable management of groundwater development.

  • PDF

Evaluation of Heat Treatment of an Al-Si Alloy forging by Using Its Relationship between Electrical Conductivity and Hardness (경도-전기전도도 상관관계를 이용한 A1-Si 알루미늄합금 열간 단조품의 열처리상태 평가)

  • 이석원;전만수;이준현
    • Transactions of Materials Processing
    • /
    • v.10 no.5
    • /
    • pp.418-424
    • /
    • 2001
  • In this study, a relationship between hardness and electrical conductivity for an Al-Si aluminum alloy, forged after extruded, is investigated. Microvickers hardness is measured and compared with its corresponding electrical conductivity obtained by the eddy current test. It is found that a distinct relationship between the hardness and the electrical conductivity exists for the material. Using the relationship, the hardness of forging is predicted from the electrical conductivity obtained by eddy current test and the result is used to evaluate the condition of heat treatment.

  • PDF

Development of Experimental Apparatus For Measuring Thermal Conductivity by Transient Probe Method (과도탐침법에 의한 열전도계수 측정장치 개발)

  • 배신철;김명윤
    • Journal of Biosystems Engineering
    • /
    • v.22 no.1
    • /
    • pp.59-67
    • /
    • 1997
  • An experimental apparatus was developed for the rapid determination of thermal conductivity by transient probe method. The theoretical basis for transient probe method has been investigated. The mathematical model for this method is the Carslaw and Jaeger model which is used perfect line source theory. The small needle probe which is equipped with thermocouple and heating element is constructed. A software that performs data analysis and acquisition is programmed. The influence of the power dissipated per unit length of the probe has been assessed for glycerin. The result showed no significant correlation between thermal conductivity and power input. Determination made with this experimental apparatus were found to agree well with the recommended thermal conductivity data.

  • PDF

The Electrical Characteristics of Amorphous $Te_{80}Se_{10}Sb_{10}$ Thin Film (비정질$Te_{80}Se_{10}Sb_{10}$ 박막의 전기적 특성)

  • 김흥석;이영종;정홍배
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.238-241
    • /
    • 1996
  • In this paper, we investigated the electrical characteristics which is d.c. and a.c. conductivity of the amorphous Te$_{80}$Se$_{10}$Sb$_{10}$thin film prepared by thermal evaporation. As the results, the d.c. conduction mechanism was followed thermally activated conduction and from the data of d.c. conductivity, the acti-vation energy and mobility gap were obtained. the d.c. conductivity was increased with temperature and a.c. conductivity also was increased with temperature and frequency. It can consider that the annealing is indispensable for higher conductivity since the activation energy decreased but d.c. and a.c. conductivity increased with annealing.aling.

  • PDF

Performance Analysis of Ground Thermal Conductivity by Ground Heat Exchanger (지중열교환기의 지중열전도도 성능 분석)

  • Kim, Young-Jun;Choi, Jae-Sang;Kang, Yong-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.161-166
    • /
    • 2005
  • The objectives of this paper are to estimate the ground thermal conductivity by ground heat exchangers in two different places - Chooncheon and Wonjoo, and to analyze the effect of ground thermal conductivity on the ground thermal diffusivity and the size of the ground heat exchanger. In Chooncheon area, a single-U type HDPE pipe (25mm diameter) with borehole diameter of 150mm, length of 150m is installed. In Wonjoo area, a single-U type HDPE pipe (40mm diameter) with borehole diameter 150mm, length of 200m is installed. It is found that the ground thermal conductivities are estimated as 2.69 $W/m^{\circ}C$ and 2.99 $W/m^{\circ}C$ in Chooncheon and Wonjoo, respectively. It is also found that the ground heat exchanger size is reduced by 8.6% with 25% increase of ground thermal conductivity, and increase by 11.8% with 25% decrease of ground thermal conductivity.