• Title/Summary/Keyword: conductivity measurement

Search Result 627, Processing Time 0.021 seconds

Improving Thermal Conductivity of Neutron Absorbing B4C/Al Composites by Introducing cBN Reinforcement (cBN 입자상 강화재 첨가에 따른 중성자 흡수용 B4C/Al 복합재의 열전도도 변화 연구)

  • Minwoo Kang;Donghyun Lee;Tae Gyu Lee;Junghwan Kim;Sang-Bok Lee;Hansang Kwon;Seungchan Cho
    • Composites Research
    • /
    • v.36 no.6
    • /
    • pp.435-440
    • /
    • 2023
  • This study aimed to enhance the thermal conductivity of B4C/Al composite materials, commonly used in transport/storage containers for spent nuclear fuel, by incorporating both boron carbide (B4C) and cubic boron nitride(cBN) as reinforcing agents in an aluminum (Al) matrix. The composite materials were successfully manufactured through a stir casting process and practical neutron-absorbing materials were obtained by rolling the fabricated composite ingot. The evaluation of the thermal conductivity of the fabricated composites was carried out because thermal conductivity is critical for neutron absorbing materials. The thermal conductivity measurement results indicated an approximately 3% increase in thermal conductivity under the same volume fraction when compared to composite materials using only B4C particles. Through neutron absorption cross-sectional area calculations, it was confirmed that the neutron absorption capability decreased to a negligible level. Based on the findings of this study, new design approaches for neutron absorption materials are proposed, contributing to the development of high-performance transport/storage containers.

Synthesis and Electrochemical Properties of Solid Polymer Electrolytes Using BF3LiMA as Monomer (BF3LiMA를 단량체로 하는 고체 고분자전해질 합성과 전기화학적 특성)

  • Kim, Kyung-Chan;Ryu, Sang-Woog
    • Journal of the Korean Electrochemical Society
    • /
    • v.14 no.4
    • /
    • pp.208-213
    • /
    • 2011
  • Solid polymer electrolytes using $BF_3LiMA$ as monomer were synthesized by usual one step radical polymerization in THF solvent. The effect of $BF_3LiMA$ concentration on ionic conductivity and electrochemical stability was investigated by AC impedance measurement and linear sweep voltammetry. As a result, the highest ionic conductivity reached $7.71{\times}10^{-6}S\;cm^{-1}$ at $25^{\circ}C$ was obtained in 12.9 wt% of $BF_3LiMA$ content. Further increase or decrease of $BF_3LiMA$ content result to decrease the ionic conductivity due to the brittle matrix properties in former case and the insufficient number of charge carrier in the latter case. Furthermore, since the counter-anion was immobilized in the self-doped solid polymer electrolytes, high electrochemical stability up to 6.0 V was observed even in $60^{\circ}C$.

The study of thermal properties of graphene/Cu foam hybrid structures (그래핀/구리폼과 그래파이트 하이브리드 구조체의 열전도 특성 연구)

  • Kim, Hee Jin;Kim, Hyeungkeun;Kim, Yena;Lee, Woo Sung;Yoon, Dae Ho;Yang, Woo Seok
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.23 no.5
    • /
    • pp.235-240
    • /
    • 2013
  • Pure-carbon materials such as graphite, graphene, carbon nanotubes, and diamond have very high thermal conductivities. The reported thermal conductivity of graphene is in the range 3000~5000W/m-K at room temperature. Here, we developed graphene/cu foam hybrid type heat spreader to obtain higher thermal conductivity than Cu foam. Hybrid materials were characterized using optical microscopy (OM), scanning electron microscopy (SEM) and thermal conductivity measurement system; LFA (Laser Flash Analysis @ LFA 447, NETZSCH). We suggest that excellent thermal properties of graphene/cu foam hybrid structures are beneficial for all proposed electrical applications and can lead to a thermal management application.

Effects of Microstructure on Thermoelectric Properties of $FeSi_2$

  • Park, Joon-Young;Song, Tae-Ho;Lee, Hong-Lim;Pai, Chul-Hoon
    • The Korean Journal of Ceramics
    • /
    • v.2 no.1
    • /
    • pp.11-18
    • /
    • 1996
  • The variation of electrical conductively and Seebeck coefficient of FeSi2 according to the density of the specimen has been observed over the temperature range 50 to $700^{\circ}C$. A conventional pressureless sintering method with various sintering time (0, 0.5, 1, 5h) at $1190^{\circ}C$ and/or various sintering temperatures(1160, 1175, 1190, $1200^{\circ}C$) for 2 h was carried out to prepare $FeSi_2$ specimens having various densities. The relationship between the electrical conductivity and Seebeck coefficient was investigated after two steps of annealing (at $865^{\circ}C$ and then $800^{\circ}C$ for total 160h) and thermoelectric measurement. The electrical conductivity for the specimens showed a typical tendency of semiconductor, the average activation energy of which in the intrinsic region (above $300^{\circ}C$) was observed approximately as 0.452 eV, and increased slightly with density. On the other hand, the specimen of the lower density showed the higher value of Seebeck coefficient in the intrinsic region. As the temperature fell into the non-degenerate region, the highly densified specimen which had relatively little residual metal phase showed the higher value of Seeback coefficient. The power factor of all specimens showed the optimum value at $200^{\circ}C$. However, the power factor of the specimen of the lower density increased again from $400^{\circ}C$ and that of the higher dense specimen increased from $500^{\circ}C$. The power factor was more affected by Seebeck coefficient than electrical conductivity over all temperature range.

  • PDF

Structure and Electrical Properties of Li2O-TiO2-P2O5/ Glasses (Li2O-TiO2-P2O5계 유리의 구조와 전기적 성질)

  • 윤기현;곽만석;이용근
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.2
    • /
    • pp.178-183
    • /
    • 2003
  • Electrical conductivity of$50Li_2O-xTiO_2-(50-x)P_2O_5$ glasses has been studied with an increase of the intermediate$TiO_2$content. Thermal properties were observed from TG-DTA measurement and the variation of glass structure was investigated by FT-IR. The density and glass transition temperature increased with an increase of the $TiO_2$ content. These results were attributed to the fact that bond strengthening was occurred because of the formation of P-O-Ti cross linkages in the glass. The ionic conductivity increased with $TiO_2$ content and a maximum value, $1.2{imes}10^{-6}$S/cm showed at x=20. The ionic conductivity showed a large increasement as a result that the pyrophosphate group become the predominant structural unit. This result can explain that Li ions mobility increased as a number of non-bridging oxygen on phosphate units increased.

A Study on the Measurement of Volumetric Water Content Using WCR in Final Cover Layer of Landfill (Water Content Reflectometer(WCR)을 이용한 매립지반 최종 복토층의 체적 함수비 측정에 관한 연구)

  • Kim Kyung-Chul;Hwang Koou-Ho;Lee Song
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.6
    • /
    • pp.147-154
    • /
    • 2005
  • This study deals with the calibration of low-frequency water content reflectometer for measuring the volumetric water content of soils in landfill final cover layer, and the validity of calibrations was evaluated by electrical conductivity and index properties of the soils. Linear calibrations concerning volumetric water content to WCR period provided good agreement with the data. Analysis of the calibration data indicates that the slope of the calibration decreases as the electrical conductivity of the soil increases. Lower slopes correspond to soils with greater clay content, organic content, liquid limit, and plasticity index, which typically have higher electrical conductivity. It could be well explained that WCR can operate in a lower frequency range.

A study on the Measurement of Soil Water Concentration by Time Domain Reflectometry (TDR(Time Domain Reflectometry)을 이용한 토양수농도 측정에 관한 연구)

  • Park, Jae-Hyeon
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.2
    • /
    • pp.123-132
    • /
    • 1998
  • Monitoring solute transport has been known to be difficult especially for the unsaturated soil. The object of this study is to investigate the TDR application to monitoring solute concentration in the vadose zone. The TDR calibration test was conducted for soil samples with various water contents and concentrations. The voltage attenuation of electromagnetic wave of TDR was used to estimate the bulk electrical conductivity of a soil. The relationship between the bulk soil electrical conductivity and the solute concentration was assumed to be linear at a constant volumetric soil water content. In this study four proposed relationships were compared using data obtained from KCI solution at three different concentrations. Relationships given by Topp, Daltaon, Yanuka showed the linearity between the bulk soil electrical conductivity and the solute concentration, which were more pronounced than Zegelin's. The three relationships were found to be useful to measure the solute concentration in the vadose zone. In addition, TDR method was proven to be a viable technique in monitoring solute transport through unsaturated soils in transient flow condition.

  • PDF

Adsorption Analysis of Fluorescent Whitening Agent on Cellulosic Fibers by Zeta Potential Measurement (지료의 제타전위 측정을 통한 형광증백제의 흡착 평가)

  • Lee, Ji Young;Kim, Eun Hea;Kim, Chul Hwan;Park, Jong Hye
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.47 no.6
    • /
    • pp.106-112
    • /
    • 2015
  • Many researchers have proposed analytical methods to measure the adsorption of di-sulpho fluorescent whitening agents (D-FWAs), but practical methods for D-FWA utilization in an actual paper mill have not been established. In particular, the D-FWA adsorption behavior must be monitored in paper mills to ensure the effective use of D-FWAs. This study used the zeta-potential of pulps as an indicator of the adsorption behavior of a D-FWA. We identified the relationship between the actual adsorption of the D-FWA and the zeta-potential of the pulps as a function of D-FWA addition. zeta-potential measurements were then used to analyze the D-FWA adsorption behavior under different conditions of pulp type, conductivity, and pH. The actual adsorption of a D-FWA was proportional to the ${\Delta}zeta-potential$ of the pulps (i.e., the difference between the zeta-potential of a pulp containing no D-FWA and one containing the D-FWA). The ${\Delta}zeta-potential$ of the pulps was therefore adopted for adsorption analysis. A higher adsorption of the D-FWA was observed onto Hw-BKP than onto Sw-BKP because of the shorter fiber length and higher fines content of Hw-BKP. A high conductivity and an acidic pH decreased the D-FWA adsorption because of direct effects of high ion concentrations and low pH on the D-FWA solubility. Therefore, a D-FWA must be added to Hw-BKP under low conductivity conditions and at neutral or alkaline pH to optimize the D-FWA adsorption.

Thermal Conductivity Measurement of High-k Oxide Thin Films (High-k 산화물 박막의 열전도도 측정)

  • Kim, In-Goo;Oh, Eun-Ji;Kim, Yong-Soo;Kim, Sok-Won;Park, In-Sung;Lee, Won-Kyu
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.2
    • /
    • pp.141-147
    • /
    • 2010
  • In this study, high-k oxide films like $Al_2O_3$, $TiO_2$, $HfO_2$ were deposited on Si, $SiO_2$/Si, GaAs wafers, and then the thermal conductivity was measured by using thermo-reflectance method which utilizes the reflectance variation of the film surface produced by the periodic temperature variation. The result shows that high-k oxide films with 50 nm thickness have high thermal conductivity of 0.80~1.29 W/(mK). Therefore, effectively dissipate the heat generated in the electric circuit such as CMOS memory device, and the heat transfer changes according to the micro grain size.

Investigation of the Effects of CNT Dosages on the Hydration and Heating Properties of Cement Composites with Low Water-to-binder Ratio (낮은 물-바인더 비를 갖는 시멘트 복합체의 CNT 첨가량에 따른 수화특성 및 발열특성)

  • Oh, Sungwoo;Jung, Sang-hwa;Chung, Wonseok;Choi, Young Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.182-188
    • /
    • 2018
  • Recently, various researches on the utilization of carbon nanotube(CNT) with superior electrical conductivity and large surface areas into concrete have been actively conducted. Thus, mechanical and thermal properties of cement-flyash composites were evaluated concerning the CNT replacements. Based on the low binder-to-water ratio, the cement composites were produced with 0.2 % and 0.5 % of CNT solids. The compressive strengths with various ages, isothermal calorimetry measurement, SEM analysis, thermal conductivity of cement composites and thermal gravimetry analysis were implemented. As the amount of CNT addition was increased, the thermal conductivity of cement composites were also increased. Also, there was no significant mechanical property differences between mixtures with and without CNTs.