• Title/Summary/Keyword: conducted EMI

Search Result 140, Processing Time 0.023 seconds

Conducted Noise Reduction in PFC Boost Converter for Air Conditioner (에어컨용 PFC Boost Converter의 전도 노이즈 저감)

  • Lee S.H.;Kim L.H.;Kim Y.G.;Won C.Y.;Kim T.D.;Kim D.K.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.793-797
    • /
    • 2003
  • Switching PFC converters are widely used not only to comply the power quality specification but also for maximum efficiency. However switching PFC converters generate serious electromagnetic interference (EMI). In this paper to solve this problem, we applied the APW(Anti Phase Winding) and RPWM(Ran-dom PWM) technique to PFC boost converter and obtained satisfactory results. Simulation and experimental results show the improved harmonic and reduced EMI effect in air-conditioner system.

  • PDF

A Study on the Simulation method for the common-mode voltage and current in the voltage fed PWM inverter system (PWM 인버터로 구동된 유도전동기의 누설전류 억제에 관한 연구(I))

  • 전진휘;이재호;이상훈;김철우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.3
    • /
    • pp.246-253
    • /
    • 2000
  • 전동기의 제어기법과 제어기 등의 발달로 유도전동기는 산업용으로 널리 보급되고 있으며, 유도전동기를 고효율로 제어하기 위하여 PWM 인버터가 널리 사용되고 있다. 그리고 IGBT와 같은 고속 스위칭 소자의 발달로 인해 전압형 PWM 인버터의 스위칭 주파수가 증가가 가능하게 됐으며, 그로 인해 매우 우수한 동작 특성을 가지게 되었다. 그러나 고속 스위칭은 전압과 전류의 급격한 변화로 인해 매 스위칭마다 발생하는 고주파 성분의 커먼 모드전압과 전류를 발생하게 되고 이들은 베어링 전류와 축전압, 전도 및 방사 EMI, 기기의 절연수명 단축, 등의 악영향을 유발한다. 본 연구에서는 이러한 커먼 모드 전압과 전류에 대한 시스템 레벨 해석이 가능한 시뮬레이션 기법에 대해 실제 측정과 시뮬레이션을 통해 검정하였다. 이를 통해서 커먼 모드 전압과 전류가 PWM 인버터 시스템의 각 부에 미치는 영향을 쉽게 확인 할 수 있으며, 커먼 모드 전압과 전류의 저감을 위해 추가될 수 있는 부가적인 보조회로의 영향에 대해서도 제시된 시뮬레이션 기법을 통해 확인 할 수 있다.

  • PDF

Conducted Noise in Switched Mode Power Supply (SMPS에서 전도성 노이즈에 관한 연구)

  • Yi, H.H.;Lee, I.H.;Lee, H.H.;Oh, D.G.;Kwon, Y.A.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.106-108
    • /
    • 2002
  • SMPS는 스위칭을 통해 전력을 변환하므로 높은 dv/dt 및 di/dt 특성을 갖게 된다. 이러한 스위칭특성으로 인해 발생하는 EMI (Electromagnetic Interference) 노이즈는 기기 내부 또는 외부에 간섭을 일으킨다. 미국의 FCC (Federal Communications Commission) 및 유럽 의 CISPR(International Special Committee on Radio Interference) 등의 규정을 만족시키기 위해서 전도성 노이즈에 대한 충분한 이해와 해석이 필요하다. 본 연구는 SMPS에서의 EMI/EMC 대책 구현에 앞서, 전도성노이즈의 기본개념 및 발생/결합 경로를 분석하고 실제로 노이즈를 측정한다. 측정을 위해 Boost 컨버터가 제작/사용된다.

  • PDF

A Study on the Low Noise Medical SMPS (의료용 SMPS 개발 및 노이즈 감소 대책에 대한 연구)

  • 이정우;김응석;김기만;윤형로
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.2 no.1
    • /
    • pp.53-58
    • /
    • 2001
  • The main noise sources in SMPS are divided into three parts: the switching devices, the rectifiers in secondary part, the output transformer and choke coil. In this paper we performed the noise analysis with respect to bobbin type and winding method, and designed an optimized transformer focusing on the transformer. For the comparison. we measured four parameters for each cases, including EMI conducted emission noise. signal from the switching devices, output ripple/noise voltage and leakage current. As the result, the transformer using a vertically-typed bobbin and a parallel, sandwich winding method showed the best performance. We confirmed that the SMPS developed in this research is satisfied with the IEC 601-1 international standard for the medical instrumentation. by testing its electrical characteristics and safety.

  • PDF

A Study on Prediction of Conducted EMI In PWM inverter fed Induction Motor Drive System (PWM 인버터-유도전동기 구동시스템의 전도노이즈 예측에 관한 연구)

  • 이진환;안정준;원충연;김영석;최세완
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.367-372
    • /
    • 1999
  • In this paper, an inverter fed induction motor drive system is analyed in order to predict the conducted interference. High frequency model for inverter, motor and system parasitic components are proposed. High frequency component allows time and frequency domain analysis to be performed with standard PSpice tool. The overall high frequency component and model are verified by comparing simulation and experimental result.

  • PDF

A Study on the Design of Conducted Noise Separator for Power Line Noise (전원선 전도잡음 분리기 설계에 관한 연구)

  • 권준혁;이응주
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.4
    • /
    • pp.552-559
    • /
    • 1998
  • Conducted noise in power line contains both the common mode(CM) and differential mode(DM) noise. These two modes of noise are caused by different noise sources and paths. Therefore, CM/DM noise must be deal with individually in EMI filter. In this paper the technique to separate power line noise is presented, which can be used to measure both the CM and the DM noise from total generated noise. Also, noise-separator is designed and experimental results showed 30 dB above of separation performance in 10 kHz~10 MHz.

  • PDF

Use of Electromagnetic Inductance for Salinity Measurement in Reclaimed Saline Land (전자장 유도 장치를 이용한 간척지 토양의 염농도 측정)

  • Jung, Yeong-Sang;Lee, Won-Ho;Joo, Jin-Ho;Yu, Il-Ho;Shin, Wan-Sik;Ahn, Yeol;Yoo, Sun-Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.36 no.2
    • /
    • pp.57-65
    • /
    • 2003
  • Mapping of salinity distribution in the reclaimed lands was attempted by using the electromagnetic inductance technique. Field study was conducted to monitor ground conductivity with an electromagnetic inductance, EM 38 (Geonics), and electrical conductivity of the saturated extract, ECe of the soils, at the Daeho reclaimed land. EM values of horizontal mode, EMh, and vertical mode, EMv, mode were recorded at the interval of $2m{\times}2m$ from the ground. Soil samples were taken through the profile down to 100cm for calibration. ECe of poor drained area of Daeho, were in the range of $19.50-91.50ds\;m^{-1}$, while ECe of well-drained area ranged from $1.10-34.40ds\;m^{-1}$. Multiple regression equations for the measured EMv, EMh, and ECe were highly significant. The EMh showed higher correlation with ECe than EMv. With the multiple equation, ECgM could be calculated. Correlation between ECe and ECgM was the highest ($r=0.753^{***}$), when EMI readings were taken on the ground. The relationships were highly significant below 30 cm height of measurement, With the EM38 measurement, the salinity distribution was effectively expressed for the experimental filed in Daeho reclaimed land.

Controller design and conducted noise reduction of FM-PWM 컨버터 (FM-PWM 컨버터의 제어기 설계와 전도성 잡음 저감)

  • Park, Seok-Ha;Jin, In-Soo;Kim, Jae-Hwan;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2733-2735
    • /
    • 1999
  • The conducted noises mainly emitted from PWM DC power supply have a periodicity with respect to switching frequency, and especially center at the switching frequency and the discrete harmonic frequencies. The concentration of noise energy at these discrete frequencies makes it harder to meet EMI regulations. To reduce the conducted noises, this paper presents the novel FM-PWM control method by using random switching frequency modulation control. This control makes it to generate the noises of side bands by shattering emission spectrum, and to reduce the peak level of conducted noises.

  • PDF

Applying the Flipped Learning Model to an English-Medium Nursing Course

  • Choi, Heeseung;Kim, Jeongeun;Bang, Kyung-Sook;Park, Yeon-Hwan;Lee, Nam-Ju;Kim, Chanhee
    • Journal of Korean Academy of Nursing
    • /
    • v.45 no.6
    • /
    • pp.939-948
    • /
    • 2015
  • Purpose: An emerging trend in Asian higher education is English-medium instruction (EMI), which uses English as the primary instructional language. EMI prepares domestic students for international leadership; however, students report difficulty in learning, and educators have raised questions concerning the effectiveness of EMI. The flipped learning model (FLM), in which lecture and homework activities for a course are reversed, was applied to an English-medium course offered by a college of nursing in Korea. The aims of this study were to: 1) revise an existing English-medium nursing course using the FLM; 2) explore students' learning experiences and their acceptance of the FLM; and 3) identify key factors in the success of FLM. Methods: We used a descriptive, cross-sectional, mixed-methods design and the participants were students at one nursing school in Korea. A series of course development meetings with faculties from the nursing school and the center for teaching and learning were used to develop the course format and content. We conducted course evaluations using the Flipped Course Evaluation Questionnaire with open-ended questions and focus group interviews. Results: Students (N=75) in a 15-week nursing course responded to a survey after completing the course. Among them, seven students participated in one of two focus groups. Overall, students accepted and favored the flipped learning strategy, and indicated that the method enhanced lecture content and their understanding of it. Factors associated with effective instruction included structured monitoring systems and motivational environments. Conclusion: The FLM requires sufficient preparation to facilitate student motivation and maximize learning outcomes.

HARMONICS OF INDUSTRIAL POWER ELECTRONIC CONVERTERS IN THE EREQUENCY RANGE UP TO 10 KHZ

  • Buttner, J.;Krechla, A.;Petzoldt, J.;Machost, D.
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.598-602
    • /
    • 1998
  • This paper refers to fundamental investigations and simulations of conducted electromagnetic inference emissions produced by power electronic devices in a frequency range from 2 to 10 kHz. The emissions of different industrial power converters were measured and compared. The influence of different working conditions over the altitude of the EMI are represented. Simulations of the power converter system including the line impedance stabilisation network certify the measurements.

  • PDF