• 제목/요약/키워드: condensation method

검색결과 570건 처리시간 0.027초

평판에서 층류 막응축의 근사해 (Approximate Solutions for Laminar Film Condensation on a Flat Plate)

  • 이승홍;권장렬;이억수
    • 설비공학논문집
    • /
    • 제3권4호
    • /
    • pp.215-221
    • /
    • 1991
  • Laminar film condensation of a saturated vapor in forced flow over a flat plate is analyzed by using integral method. Laminar condensate film is so thin that the inertia and thermal convection terms in liquid flow can be neglected. Approximate solutions for water are presented and well agreed with the similarity solutions over the wide range of physical parameter, Cp1(Ts-Tw)/Pr.hfg. For the strong condensation case, it is found that magnitude of the interfacial shear stress at the liquid-vapor interphase boundary is approximately equal to the momentum transferred by condensation, i.e., ${\tau}_i{\simeq}\dot{m}(U_O-U_i)$.

  • PDF

CFD와 TDR을 이용한 고층 공동주택의 결로 판정 도구 개발 (Development of Analytical Tool for Checking Condensation of High-Rise Apartment Using CFD & TDR)

  • 방승기;김철현
    • 한국지열·수열에너지학회논문집
    • /
    • 제9권4호
    • /
    • pp.15-24
    • /
    • 2013
  • On this Thesis, We conduct a research of curtain wall high-rise apartment located in Songdo for preparing a simple method to check possibility of condensation on each part of curtain wall using only indoor temperature, humidity and outdoor temperature. According to CFD analysis result, condensation occurred if indoor environment did not ventilated. On the other hand, in case of ventilation on indoor environment, condensation did not appear; so I could find ventilation prevent surface condensation on inside surface of curtain wall. Moreover, when temperature of the floor is higher, condensation is decrease more than lower floor temperature.

대형 시스템에서의 다단계 부분구조 기법을 이용한 시스템 축소기법에 관한 연구 (Study on the Structural System Condensation using Multi-level Sub-structuring Scheme in Large-scale Problems)

  • 백승민;김현기;조맹효
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2008년도 정기 학술대회
    • /
    • pp.356-361
    • /
    • 2008
  • Eigenvalue reduction schemes approximate the lower eigenmodes that represent the global behavior of the structures. In the previous study, we proposed a two-level condensation scheme (TLCS) for the construction of a reduced system. And we have improved previous TLCS with combination of the iterated improved reduced system method (IIRS) to increase accuracy of the higher modes intermediate range. In this study, we apply previous improved TLCS to multi-level sub-structuring scheme. In the first step, the global system is recursively partitioned into a hierarchy of sub-domain. In second step, each uncoupled sub-domain is condensed by the improved TLCS. After assembly process of each reduced sub-eigenvalue problem, eigen-solution is calculated by Lanczos method (ARPACK). Finally, Numerical examples demonstrate performance of proposed method.

  • PDF

비비례 감쇠 구조의 고유치 문제에 대한 반복적인 동적 축소법 (Dynamic Condensation using Iterative Manner for Structural Eigenproblem with Nonproportional Damping)

  • 조맹효;최동수
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2008년도 정기 학술대회
    • /
    • pp.342-349
    • /
    • 2008
  • A selection method of primary degrees of freedom in dynamic condensation for nonproportional damping structures is proposed. Recently, many dynamic condensation schemes for complex eigenanalysis have been applied to reduce the number of degrees of freedom. Among them, iterative scheme is widely used because accurate eigenproperties can be obtained by updating the transformation matrix in every iteration. However, a number of iteration to enhance the accuracy of the eigensolutions may have a possibility to make the computation cost expensive. This burden can be alleviated by applying properly selected primary degrees of freedom. In this study, which method for selection of primary degrees of freedom is best fit for the iterative dynamic condensation scheme is presented through the results of a numerical experiment. The results of eigenanalysis of the proposed method is also compared to those of other selection schemes to discuss a computational effectiveness.

  • PDF

초전도 박막 제작을 위한 산화 시스템 구축 및 평가 (Construction and Evaluation of Oxidation System for Superconductor Thin Film)

  • 임중관;박용필;송경용
    • 한국전기전자재료학회논문지
    • /
    • 제16권2호
    • /
    • pp.163-167
    • /
    • 2003
  • Ozone is strong and useful oxidizing gas for the fabrication of oxidation thin films. In order to obtain high quality thin film, the ozone concentration must be increased. An ozone condensation system is evaluated in the viewpoint of an ozone supplier for oxidation thin film growth. Ozone is condensed by the adsorption method and ozone concentration reaches 8.5 mol% by 2.5 h after the beginning of the ozone condensation is negligible if the condensed ozone is transferred between the ozone condensation system and the film growth chamber within a few minutes. CuO peak which is the result of the obtained Cu-films using condensed ozone appears by XRD patterns.

수직 벽에서 과열증기의 막응축에 대한 열물성의 영향 (The Influence of Variable Thermophysical Properties for Filmwise Condensation of Superheated Vapor on a Vertical Wall)

  • 김경훈;성현찬
    • 설비공학논문집
    • /
    • 제12권3호
    • /
    • pp.235-243
    • /
    • 2000
  • A theoretical model for laminar filmwise condensation along an isothermal vertical wall at constant pressure has been formulated on the basis of conservation laws and other fundamental physical principles. The model was applied to the prediction of the influences of variable thermophysical properties of liquid and vapor layers in the filmwise condensation of superheated vapor of Rl2, R134a, R142b and R152a. The dimensionless velocity component method was employed in the transformation of the governing equations and their boundary conditions, and the polynomial method was used for treating variable thermophysical properties of liquid and vapor. Physical quantities, such as the dimensionless thickness of the liquid layer, local heat transfer rate and mean heat transfer coefficient, were investigated for different values of the superheated temperature of the stagnant vapor far from the wall. It was found that the value of mean heat transfer coefficient of R134a was higher than other refrigerants for the change of the superheated temperature.

  • PDF

초음속 노즐에서 발생하는 응축충격파 진동의 피동제어 (Passive Control of the Condensation Shock Wave Oscillation in a Supersonic Nozzle)

  • 백승철;권순범;김희동
    • 대한기계학회논문집B
    • /
    • 제26권7호
    • /
    • pp.951-958
    • /
    • 2002
  • Rapid expansion of a moist air or a stream through a supersonic nozzle often leads to non-equilibrium condensation shock wave, causing a considerable energy loss in flow field. Depending on amount of latent heat released due to non-equilibrium condensation, the flow is highly unstable or a periodical oscillation accompanying the condensation shock wave in the nozzle. The unsteadiness of the condensation shock wave is always associated with several kinds of instabilities as well as noise and vibration of flow devices. In the current study, a passive control technique using a porous wall with a plenum cavity underneath is applied for the purpose of alleviation of the condensation shock oscillations in a transonic nozzle. A droplet growth equation is coupled with two-dimensional Navier-Stokes equation system. Computations are carried out using a third-order MUSCL type TVD finite-difference scheme with a second-order fractional time step. An experiment using an indraft wind tunnel is made to validate the present computational results. The results show that the oscillations of the condensation shock wave are completely suppressed by the current passive control method.

공동주택 결로 하자 사례를 통한 개선방안 도출 (Study on the Improvement Plans of Condensation Defect Examples in Apartment Building)

  • 오세민;박선효;정광섭
    • 설비공학논문집
    • /
    • 제29권2호
    • /
    • pp.82-88
    • /
    • 2017
  • There are main issues of defect type that condensation, concrete crack and noise in apartment buildings. Especially, according to the Apartment Defect Dispute Mediation Committee in Korea (ADDMC) at Ministry of Land Infrastructure and Transport in Korea (MLIT), condensation defects are great importance (14 percent) on whole number of reported cases of faults from 2015 in Korea. Most condensation defects have many different causes that take a toll on the resident's life and space. So it is very important to early detection and repair. For preventing the condensation in apartment buildings, there are building codes in Korea such as 'Standard of Method and Judgment for Apartment defect of investigation, Repair cost Estimate'. This research aims to study on the improvement of preventing the condensation aforementioned korea standard. Types and characteristics (opaque wall, windows, doors) of cause of occurrence and existing state condensation defect is analyzed from evaluation of real application 100 case in 2015 ADDMC data.

금속 산화물 박막 제작을 위한 산화 시스템의 평가 (Evaluation of Oxidation System for Metal Oxide Thin Film)

  • 임중관;김종서;박용필
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 춘계종합학술대회
    • /
    • pp.590-593
    • /
    • 2003
  • 금속 산화물 박막 제작에 유효한 산화가스로 오존가스를 채택했다. 고품질의 산화 박막을 얻기 위해 고농도 오존이 필요하여 오존 농축 시스템을 구축 및 평가하였다. 이 장치는 실리카겔로 오존의 선택 흡착을 이용해, 농축 공정 시작 후 유입 농도 8.5 mol%가 검출되는 2.5 h에서 농축이 완료되고, 진공 배기로 고농도 오존가스를 생성하였으며, 성막 장치까지 가스가 공급되는 몇 분 동안은 자연분해 효과를 무시할 수 있었다.

  • PDF

Condensation Prevention Performance Assessment Taking Into Account Thermal Insulation Performance Degradation Due to Aging for Apartment Housing

  • Choi, Doo-Sung;Lee, Myung-Eun
    • KIEAE Journal
    • /
    • 제15권6호
    • /
    • pp.11-18
    • /
    • 2015
  • Purpose: The current study analyzed trends in thermal insulation performance with aging, and condensation characteristics caused by the former. Method: Thermal insulation and condensation prevention performance of an architecture were assessed using Temperature Difference Ration Inside, or TDRi. Subjects of this quantitative analysis in thermal insulation performance change due to aging included recently constructed apartments and aged apartments older than 40 years. Time series comparison and analysis were conducted to observed changes in the thermal insulation performance and condensation characteristics. Result: Analysis showed that wall insulation performance degraded with aging regardless of fortified insulating material usage or insulating material type, which caused increased danger of condensation. In addition, when fortified insulating material was installed on the connection between the walls, insulation performance degradation was lower compared to cases in which fortified materials were not used. In all cases from 1 to 10, the rate of thermal insulation performance degradation increased after 20 years of aging.