• 제목/요약/키워드: concrete-filled steel tube

검색결과 446건 처리시간 0.034초

Performance-based Design of 300 m Vertical City "ABENO HARUKAS"

  • Hirakawa, Kiyoaki;Saburi, Kazuhiro;Kushima, Souichirou;Kojima, Kazutaka
    • 국제초고층학회논문집
    • /
    • 제3권1호
    • /
    • pp.35-48
    • /
    • 2014
  • In designing a 300 meter high skyscraper expected to be the tallest building in Japan, an earthquake-ridden country, we launched on the full-scale performance based design to ensure redundancy and establish new specifications using below new techniques. The following new techniques are applied because the existing techniques/materials are not enough to meet the established design criteria for the large-scale, irregularly-shaped building, and earth-conscious material saving and construction streamlining for reconstructing a station building are also required: ${\bullet}$ High strength materials: Concrete filled steel tube ("CFT") columns made of high-strength concrete and steels; ${\bullet}$ New joint system: Combination of outer diaphragm and aluminium spray jointing; ${\bullet}$ Various dampers including corrugated steel-plate walls, rotational friction dampers, oil dampers, and inverted-pendulum adaptive tuned mass damper (ATMD): Installed as appropriate; and ${\bullet}$ Foundation system: Piled raft foundation, soil cement earth-retaining wall construction, and beer bottle shaped high-strength CFT piles.

Experimental and analytical investigations of CFFT columns with and without FRP bars under concentric compression

  • Khan, Qasim S.;Sheikh, M. Neaz;Hadi, Muhammad N.S.
    • Steel and Composite Structures
    • /
    • 제30권6호
    • /
    • pp.591-601
    • /
    • 2019
  • This research study investigates experimentally and analytically the axial compressive behaviour of Concrete Filled Fiber Reinforced Polymer Tube (CFFT) columns with and without Fiber Reinforced Polymer (FRP) bars. The experimental program comprises five circular columns of 204-206 mm outer diameter and 800-812 mm height. All columns were tested under concentric axial compressive loads. It was found that CFFT columns with and without FRP bars achieved higher peak axial compressive loads and corresponding axial deformations than conventional steel reinforced concrete (RC) column. The contribution of FRP bars was about 12.1% of the axial compressive loads carried by CFFT columns reinforced with FRP bars. Axial load-axial deformation ($P-{\delta}$) curves of CFFT columns were analytically constructed, which mapped well with the experimental $P-{\delta}$ curves. Also, an equation was proposed to predict the axial compressive load capacity of CFFT columns with and without FRP bars, which adequately considers the contributions of the circumferential confinement provided by FRP tubes and lower ultimate strength of FRP bars in compression than in tension.

무내화피복 CFT 공법의 내화성능 확보를 위한 실험적 연구 (An Experimental Study on the Ensuring the Fire Resistance Performance of Non-Refractory Coating CFT)

  • 이지환;한민철
    • 한국건축시공학회지
    • /
    • 제15권3호
    • /
    • pp.273-280
    • /
    • 2015
  • 본 연구는 3시간 내화성능을 만족할 수 있는 고성능 무내화피복 CFT 기둥 개발을 위한 연구로서, 고로슬래그 미분말 치환율에 따른 성능평가를 실시한 결과 고로슬래그 미분말 치환율이 증가함에 따라 내화성능이 개선되는 것을 확인 할 수 있었으며, 내화성능을 고려한 CFT 기둥용 100MPa 충전콘크리트의 고로슬래그 미분말 적정 사용량은 40%로 나타났다. 이에 따라 고로슬래그 미분말 40% 혼입 100MPa 충전콘크리트를 적용한 CFT 실물 시험체를 대상으로 재하하중별 내화시험을 실시한 결과 재하하중이 증가함에 따라 내화성능 발현시간이 감소하는 것으로 나타났으며, 재하하중 2,000kN에서는 240분 이상의 내화성능을 나타내었고, 3,000kN에서는 184분, 4,000kN에서는 120분의 내화성능을 나타내었다.

T형 스티프너를 이용한 콘크리트 충전강관 기둥-보 접합부의 해석에 관한 연구 (Analysis of CFT Beam-to-Column Connections with T-Stiffeners)

  • 신경재;김현성
    • 한국강구조학회 논문집
    • /
    • 제17권3호통권76호
    • /
    • pp.375-384
    • /
    • 2005
  • 본 논문은 T형 스티프너를 이용한 콘크리트 충전각형강관-H형강보 접합부의 응력전달 메카니즘을 유한요소해석을 통해 정확히 이해하고, T스티프너에 관한 설계기본자료를 제공하는데 그 목적이 있다. 선행된 실대형 접합부의 실험결과에서 나타난 문제점을 파악하기 위해 실험체와 동일한 형상의 비선형 유한요소해석을 수행하여 결과를 비교하였다. 접합부의 응력전달 메카니즘을 이해하기 위해 T형 스티프너의 형상을 변수로 하여 주요 부위의 여러 응력 및 변형도 지수를 사용하였다. 해석 모델은 크게 T형스티프너 상세에 따라 3개의 계열로 분류하였다. 유한요소해석을 통한 변수해석의 결과를 이용하여 보플랜지와 수평스티프너 접합부의 응력집중을 감소시킬 수 있는 방안을 모색하였다. 접합부 상세에 따른 여러 지수의 변화를 토대로 하여 T형 스티프너의 설계를 위한 기본자료와 최소 크기를 제시하였다.

외다이아프램 응력경로에 따른 용접조립 각형기둥-보 접합부의 내진성능 평가 (Seismic Evaluation of Welded-formed square Column-Beam Connection for External Diaphragm Stress path)

  • 김선희;염경수;최성모
    • 한국강구조학회 논문집
    • /
    • 제26권4호
    • /
    • pp.311-322
    • /
    • 2014
  • 콘크리트 충전강관 기둥에 모멘트 접합부를 만들기 위해서는 추가적인 다이아프램 설치가 필요하다. 그 중 내측 다이아프램과 관통 다이아프램을 용접하기 위해서는 기둥강관에 특수한 용접기술이 필요하다. 하지만 이런 기술은 제작업체의 특수장비 보유에 따라서 제작성 저하와 생산단가 상승 유도 등의 문제를 갖고 있다. 따라서 본 연구에서는 외다이아프램을 갖는 실대형 기둥-보 접합부를 제작하였고, 반복가력 실험을 수행하였다. 다이아프램의 용접 유무와 콘크리트 충전 여부, 형상에 따른 총 6개의 T자형 접합부 실험을 통해 내진성능을 평가하였다. 또한 외다이아프램 내력식에 대한 분석이 이뤄졌다. 본 실험에서 나온 결과를 인장내력식의 적절성을 검토 하였다.

복합십자형 CFT 기둥-보 접합부의 내력식에 관한 연구 (A Study on the Equations for Load Carrying Capacities of Concrete Filled tubular Square Column-to-Beam Connections with Combined Cross Diaphragm and Sleeves)

  • 최성모;정도섭;김대중;김진호
    • 한국강구조학회 논문집
    • /
    • 제17권4호통권77호
    • /
    • pp.419-429
    • /
    • 2005
  • 본 연구의 목적은 기존의 복합십자형 다이아프램을 사용한 CFT 기둥-보 인장측 접합부에 관한 연구에 이어서 접합부 각 요소의 구조적 특성을 명료하게 하는데 있다. 복합십자형 다이아프램은 기존 접합부의 하중전달 경로 및 다이아프램의 갑작스런 기하학적인 형상 변화에 대한 디테일을 개선함으로서, 보 플랜지 및 다이아프램에 응력을 고르게 분포시키고 접합부의 응력집중이 완화된 접합방식이다. 복합십자형 다이아프램을 접합부에서 중요한 요소 중 하나인 슬리브에서의 응력전달에 관하여 연구를 수행하였다. 슬리브의 두께 및 길이를 변수로 하여 해석한 결과, 슬리브의 길이 및 두께는 접합부의 내력에 큰 영향을 주지 않고 다이아프램으로부터의 하중을 콘크리트로 전달시키는 매개체의 역할을 하였다. 또한 적정 슬리브의 길이 및 두께를 각각 직경의 1배, 슬리브 직경/두께비를 20으로 제안한다. 기존의 내력식을 검토하여 메커니즘을 수정한 후 적용가능한 접합부의 극한내력식 및 항복내력식을 제안하였다.

Axial compressive behaviour of circular CFFT: Experimental database and design-oriented model

  • Khan, Qasim S.;Sheikh, M. Neaz;Hadi, Muhammad N.S.
    • Steel and Composite Structures
    • /
    • 제21권4호
    • /
    • pp.921-947
    • /
    • 2016
  • Concrete Filled Fibre Reinforced Polymer Tube (CFFT) for new columns construction has attracted significant research attention in recent years. The CFFT acts as a formwork for new columns and a barrier to corrosion accelerating agents. It significantly increases both the strength capacity (Strength enhancement ratio) and the ductility (Strain enhancement ratio) of reinforced concrete columns. In this study, based on predefined selection criteria, experimental investigation results of 134 circular CFFT columns under axial compression have been compiled and analysed from 599 CFFT specimens available in the literature. It has been observed that actual confinement ratio (expressed as a function of material properties of fibres, diameter of CFFT and compressive strength of concrete) has significant influence on the strength and ductility of circular CFFT columns. Design oriented models have been proposed to compute the strength and strain enhancement ratios of circular CFFT columns. The proposed strength and strain enhancement ratio models have significantly reduced Average Absolute Error (AAE), Mean Square Error (MSE), Relative Standard Error of Estimate (RSEE) and Standard Deviation (SD) as compared to other available strength and strain enhancement ratios of circular CFFT column models. The predictions of the proposed strength and strain enhancement ratio models match well with the experimental strength and strain enhancement ratios investigation results in the compiled database.

Seismic applicability of a long-span railway concrete upper-deck arch bridge with CFST rigid skeleton rib

  • Shao, Changjiang;Ju, Jiann-wen Woody;Han, Guoqing;Qian, Yongjiu
    • Structural Engineering and Mechanics
    • /
    • 제61권5호
    • /
    • pp.645-655
    • /
    • 2017
  • To determine the seismic applicability of a long-span railway concrete upper-deck arch bridge with concrete-filled steel-tube (CFST) rigid skeleton ribs, some fundamental principles and seismic approaches for long-span bridges are investigated to update the design methods in the current Code for Seismic Design of Railway Engineering of China. Ductile and mixed isolation design are investigated respectively to compare the structural seismic performances. The flexural moment and plastic rotation demands and capacities are quantified to assess the seismic status of the ductile components. A kind of triple friction pendulum (TFP) system and lead-plug rubber bearing are applied simultaneously to regularize the structural seismic demands. The numerical analysis shows that the current ductile layout with continuous rigid frame approaching spans should be strengthened to satisfy the demands of rare earthquakes. However, the mixed isolation design embodies excellent seismic performances for the continuous girder approaching span of this railway arch bridge.

Influence of stiffeners on the performance of blind-bolt end-plate connections to CFST columns

  • Ding, Fa-xing;Pan, Zhi-cheng;Liu, Peng;Huang, Shi-jian;Luo, Liang;Zhang, Tao
    • Steel and Composite Structures
    • /
    • 제36권4호
    • /
    • pp.447-462
    • /
    • 2020
  • The paper aims to investigate the mechanical mechanism and seismic effect of stiffeners in blind bolt endplate connection to CFST column. A precise 3D finite element model with considering the cyclic properties of concrete and steel materials was established, and the efficiency was validated through monotonic and cyclic test data. The deforming pattern and the seismic performance of the unstiffened and stiffened blind bolt endplate connections were investigated. Then a parametric analysis was conducted to analyze the contribution of stiffeners and the joint working behaviors with endplate under cyclic load. The joint stiffness classifications were compared and a supplement stiffness classification method was proposed, and the energy dissipation ability of different class connections were compared and discussed. Results indicated that the main deformation pattern of unstiffened blind bolt endplate connections was the local bending of end plate. The vertical stiffeners can effectively alleviate the local bending deformation of end plate. And influence of stiffeners in thin endplate and thick endplate was different. Based on the stiffness of external diaphragm welded connection, a more detailed rigidity classification was proposed which included the pin, semi-rigid, quasi-rigid and rigid connection. Beam was the main energy dissipation source for rigid connection. For the semi-rigid and quasi-rigid connection, the extended endplate, stiffeners and steel beam would all participate in the energy dissipation.

CFT 기둥-보 내다이아프램의 형상변화를 고려한 인장실험 (Tension test considering the shape change of CFT Column-to-Beam Interior Diaphragm)

  • 곽성신;최병정
    • 한국산학기술학회논문지
    • /
    • 제20권2호
    • /
    • pp.67-75
    • /
    • 2019
  • 콘크리트 충전강관(Concrete Filled Steel Tube, 이하 CFT) 기둥에 사용되는 내다이아프램은 사용 강재량은 적으나 강관과 네 면을 용접해야 하므로 용접이 까다롭고 개구부가 필요한 단점을 가지고 있다. 본 연구에서 살펴보고자하는 개선 다이아프램은 콘크리트 충전을 위한 중앙부 홀을 4등분하여 각 코너부위를 절삭했다. 개선 다이아프램은 중앙부 홀의 넓이는 기존 다이아프램과 동일하지만 강관과 접하는 다이아프램의 폭이 감소하여 용접 길이가 기존 다이아프램 대비 약 70%가 감소된다. 개선 다이아프램의 인장성능을 검토하기 위하여 콘크리트 타설 홀의 반지름인 R값을 설계 변수로 3개의 실험체를 제작하였다. 단순 인장 실험을 통하여 내다이아프램에 동일 하중을 받았을 때 각 실험체의 면내 변형률을 분석하였다. 범용유한요소해석 프로그램을(ANSYS 19.2)를 사용하여 실제 단순 인장 실험과 동일한 조건으로 해석을 수행하고 개선 다이아프램과 기존 다이아프램의 하중 전달을 비교하였다. 다이아프램의 폭이 플랜지 폭과 같거나 작을 때는 다이아프램의 단부에서 부터 응력이 집중되고 플랜지 폭이 더 클 때는 중앙부에서 응력이 집중되는 것을 확인하였다.