• 제목/요약/키워드: concrete strut

검색결과 257건 처리시간 0.02초

콘크리트 스트럿의 유효강도가 콘크리트 부재의 설계에 미치는 영향 (Effect of Effective Compressive Strength of Concrete Strut on Structural Concrete Design)

  • 윤영묵;석철호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.241-246
    • /
    • 2000
  • In the strut-tie model design of structural concrete, the importance of the effective strength of concrete strut has been overlooked by many practitioners. The authors believe that the effective strength of concrete strut is an important factor not only in determining steel tie forces but also in verifying the nodal zone strength and geometric compatibility condition of a selected strut-tie model. This study evaluate the effect of the effective strength of concrete strut on structural concrete design by applying the different effective strut strengths to the strut-tie model design of a post-tensioned anchorage zone and a continuous concrete deep beam.

  • PDF

스트럿-타이 모델에 의한 콘크리트 부재 설계방법의 고찰 (Strut-Tie Model Design Approaches of Structural Concrete)

  • 윤영묵
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.821-826
    • /
    • 2001
  • This paper presents four types of strut-tie model design approaches of structural concrete through the anchorage zone design of a post-tensioned concrete I-beam. The differences and distinctive feature of each approach in terms of structural type of selected strut-tie model, external force acting on strut-tie model, effective strength of concrete strut, and strut-tie model design procedure are analyzed and compared. The outcomes of present study enable structural designers to understand the merits and demerits of each strut-tie model design approach, and thus to conduct reasonable and accurate design of structural concrete.

  • PDF

콘크리트 스트럿 유효강도 결정방법의 적합성 평가 (Validity Evaluation of Determination Methods of Effective Concrete Strut Strength)

  • 윤영묵
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.595-599
    • /
    • 2003
  • For implementation of the strut-tie model approach to the practical analysis and design of structural concrete, the effective strengths of concrete struts in a strut-tie model, which have a crucial effect on the determination of strut and tie forces and the validity verification of strut-tie model's geometric compatibility condition, have to be determined accurately. In this study, the validity of the methods for determining the effective strengths of concrete struts was evaluated by conducting the strut-tie model analyses of the three reinforced concrete deep beams tested to failure with the effective strengths of concrete struts obtained from the suggested determination methods.

  • PDF

Strut-tie model evaluation of behavior and strength of pre-tensioned concrete deep beams

  • Yun, Young Mook
    • Computers and Concrete
    • /
    • 제2권4호
    • /
    • pp.267-291
    • /
    • 2005
  • To date, many studies have been conducted for the analysis and design of reinforced concrete members with disturbed regions. However, prestressed concrete deep beams have not been the subject of many investigations. This paper presents an evaluation of the behavior and strength of three pre-tensioned concrete deep beams failed by shear and bond slip of prestressing strands using a nonlinear strut-tie model approach. In this approach, effective prestressing forces represented by equivalent external loads are gradually introduced along strand's transfer length in the nearest strut-tie model joints, the friction at the interface of main diagonal shear cracks is modeled by the aggregate interlock struts along the direction of the cracks in strut-tie model, and an algorithm considering the effect of bond slip of prestressing strands in the strut-tie model analysis and design of pre-tensioned concrete members is implemented. Through the strut-tie model analysis of pre-tensioned concrete deep beams, the nonlinear strut-tie model approach proved to present effective solutions for predicting the essential aspects of the behavior and strength of pre-tensioned concrete deep beams. The nonlinear strut-tie model approach is capable of predicting the strength and failure modes of pre-tensioned concrete deep beams including the anchorage failure of prestressing strands and, accordingly, can be employed in the practical and precise design of pre-tensioned concrete deep beams.

Numerical method for the strength of two-dimensional concrete struts

  • Yun, Y.M.
    • Computers and Concrete
    • /
    • 제28권6호
    • /
    • pp.621-634
    • /
    • 2021
  • For the reliable strut-and-tie model (STM) design of disturbed regions of concrete members, structural designers must accurately determine the strength of concrete struts to check the strength conditions of a selected STM el and the anchorage of reinforcing bars in nodal zones. In this study, the author proposed a consistent numerical method for strut strength, applicable to all two-dimensional STMs. The proposed method includes the effects of a biaxial stress state associated with tensile strains in reinforcing bars crossing a strut, deviation angle between strut orientation and compressive principal stress flow, and degree of confinement provided by reinforcement. The author examined the method's validity through the STM prediction of the ultimate strengths of 517 reinforced concrete (RC) deep beams, 24 RC panels, and 258 RC corbels, all tested to failure.

스트럿-타이 모델을 이용한 세장한 철근콘크리트 부재의 강도평가 (Evaluation of Shear Strength of RC Beams using Strut-and-Tie Model)

  • 박홍근;엄태성;박종철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.271-274
    • /
    • 2005
  • Existing strut-and-tie model cannot be applied to analysis of slender beams without shear reinforcement because shear transfer mechanism is not formed. In the present study, a new strut-and-tie model with rigid joint was developed. Basically, concrete strut is modeled as a frame element which can transfer shear force (or moment) as well as axial force. Employing Rankine failure criterion, failure strength due to shear-tension and shear-compression developed in compressive concrete strut was defined. For verification, various test specimens were analyzed and the results were compared with tests. The proposed strut-and-tie model predicted shear strength and failure displacement with reasonable precision, addressing the design parameters such as shear reinforcement, concrete compressive strength, and shear span ratio.

  • PDF

Strut-tie model for two-span continuous RC deep beams

  • Chae, H.S.;Yun, Y.M.
    • Computers and Concrete
    • /
    • 제16권3호
    • /
    • pp.357-380
    • /
    • 2015
  • In this study, a simple indeterminate strut-tie model which reflects complicated characteristics of the ultimate structural behavior of continuous reinforced concrete deep beams was proposed. In addition, the load distribution ratio, defined as the fraction of applied load transferred by a vertical tie of truss load transfer mechanism, was proposed to help structural designers perform the analysis and design of continuous reinforced concrete deep beams by using the strut-tie model approaches of current design codes. In the determination of the load distribution ratio, a concept of balanced shear reinforcement ratio requiring a simultaneous failure of inclined concrete strut and vertical steel tie was introduced to ensure the ductile shear failure of reinforced concrete deep beams, and the primary design variables including the shear span-to-effective depth ratio, flexural reinforcement ratio, and compressive strength of concrete were reflected upon. To verify the appropriateness of the present study, the ultimate strength of 58 continuous reinforced concrete deep beams tested to shear failure was evaluated by the ACI 318M-11's strut-tie model approach associated with the presented indeterminate strut-tie model and load distribution ratio. The ultimate strength of the continuous deep beams was also estimated by the experimental shear equations, conventional design codes that were based on experimental and theoretical shear strength models, and current strut-tie model design codes. The validity of the proposed strut-tie model and load distribution ratio was examined through the comparison of the strength analysis results classified according to the primary design variables. The present study associated with the indeterminate strut-tie model and load distribution ratio evaluated the ultimate strength of the continuous deep beams fairly well compared with those by other approaches. In addition, the present approach reflected the effects of the primary design variables on the ultimate strength of the continuous deep beams consistently and reasonably. The present study may provide an opportunity to help structural designers conduct the rational and practical strut-tie model design of continuous deep beams.

스트럿-타이 모델 방법에 의한 콘크리트 구조물의 해석 및 설계 (Analysis and Design of Concrete Structures with Strut-Tie Model Approach)

  • 윤영묵;박문호;박승진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 봄 학술발표회 논문집
    • /
    • pp.251-256
    • /
    • 1995
  • This paper presents an evaluation of the strength and behavior of a tested simply supported rectangular reinforced eoncrete beam and a design example of a shear wall using two-dimensional strut-tie model with finite element nonlinear analysis. Strut-tie models reflecting the actual support and loading conditions are developed for the beam and shear wall. The strut-tie model not only provides simple solutions for large number of design situations dealing with the entire range of concrete structures which appear to be rather complicated but also predicts the behavior and strength of concrete members.

  • PDF

3차원 콘크리트 스트럿의 유효강도 (Effective Strength of 3-Dimensional Concrete Strut)

  • 윤영묵
    • 대한토목학회논문집
    • /
    • 제34권2호
    • /
    • pp.403-413
    • /
    • 2014
  • 스트럿-타이 모델 방법을 이용한 콘크리트 구조부재의 설계 시 가장 중요한 요소 중 하나는 콘크리트 스트럿의 유효강도를 정확하게 결정하는 것이다. 콘크리트 스트럿의 유효강도를 결정하기 위한 많은 연구가 진행되어 왔으며, 여러 종류의 스트럿의 유효강도 값 및 산정식이 제안되었다. 그러나 이들은 2차원 콘크리트 구조부재의 스트럿-타이 모델 설계를 위한 것으로, 그 값을 3차원 콘크리트 구조부재의 설계에 적용하는 것은 적절하지 않다. 이 연구에서는 콘크리트 스트럿이 위치한 곳의 3축 응력 상태, 콘크리트의 3차원 파괴기준, 스트럿 길이의 영향, 스트럿과 압축 주응력 흐름과의 불일치의 영향, 콘크리트 압축강도의 영향, 그리고 철근에 의한 콘크리트 스트럿의 구속의 정도 등을 고려하여 3차원 콘크리트 스트럿의 유효강도를 일관성 있게 결정할 수 있는 방법을 제안하였다. 제안한 방법의 타당성을 검증하기 위해 기존 연구자들에 의해 파괴실험이 수행된 115개의 철근콘크리트 파일캡 시험체의 극한강도를 평가하였으며, 그 결과를 실험결과 및 현행 설계기준에서 제안한 스트럿의 유효강도 값을 이용하여 평가한 결과와 비교분석하였다.

스트럿-타이 모델에 의한 개구부를 갖는 깊은 보의 극한강도 예측 (Prediction of Ultimate Strength of Concrete Deep Beams with an Opening Using Strut-and-Tie Model)

  • 지호석;송하원;변근주
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.189-194
    • /
    • 2001
  • In this study, ultimate strength of concrete deep beams with an opening is predicted by using Strut-and-Tie Model with a new effective compressive strength. First crack occurs around an opening by stress concentration due to geometric discontinuity. This results in decreasing ultimate strength of deep beams with an opening compared with general deep beams. With fundamental notion that ultimate strength of deep beam with an opening decreases as a result of reduction in effective compressive strength of a concrete strut, an equivalent effective compressive strength formula is proposed in order to reflect ultimate strength reduction due to an opening located in a concrete strut. An equivalent effective compressive strength formula which can reflect opening size and position is added to a testified algorithm of predicting ultimate strength of concrete deep beams. Therefore, ultimate strength of concrete deep beam with an opening is predicted by using a simple and rational STM algorithm including an equivalent effective compressive strength formula, not by finite element analysis or a former complex Strut-and-Tie Model

  • PDF