• Title/Summary/Keyword: concrete spalling

Search Result 351, Processing Time 0.026 seconds

Explosive Spalling of Structural Lightweight Aggregate Concrete (구조용 경량골재 콘크리트의 폭렬특성)

  • Song, Hun;Lee, Jong-Chan;Lee, Sea-Hyun;Kim, Woo-Jae
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.477-480
    • /
    • 2006
  • Normally, with all ensuring the fire resistance structure as a method of setting the required cover thickness to fire, the RC is significantly affected from the standpoint of its structural stability that the compressive strength and elastic modulus is reduced by fire. Especially, high strength concrete and lightweight aggregate concrete is occurred serious fire performance deterioration by explosive spalling. Thus, this study is concerned with explosive spalling of lightweight concrete using structural lightweight aggregate. From the experimental test result, lightweight aggregate concrete is happened explosive spalling. The decrease of cross section caused by explosive spalling made sharp increasing gradient of inner temperature.

  • PDF

Evaluation on Spalling Properties of Specimen Size with PP Fiber and Fireproof Coating

  • Kim, Gyu-Yong;Min, Choong-Siek;Lee, Tae-Gyu;Miyauchi, Hiroyuki;Park, Gyu-Yeon;Lee, Gwang-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.4
    • /
    • pp.353-362
    • /
    • 2011
  • High Strength Concrete (HSC) has weakness that in a fire, it is spalled and brittles. The phenomenon of spalling is made by water vapor's being confined in watertight concrete. This study is aimed to evaluate explosive spalling properties of high strength concrete with ${\square}100{\times}100{\times}200$ mm specimen and ${\square}400{\times}400{\times}1500$ mm column. To prevent spalling of concrete, fireproof coating and PP fiber are used. As a result, ${\square}400{\times}400{\times}1500$ mm column was prevented spalling likes ${\times}100{\times}100{\times}200$ mm specimen. When concrete protected failure to explosive spalling, quantity heat ratio (which fireproof coating specimen to pp fiber mixed specimen) between ${\square}100{\times}100{\times}200$ mm and ${\square}400{\times}400{\times}1500$ mm was maximum value at 20 minute, but difference of quantity heat ratio decreased and quantity heat ratio of each specimen is almost same at 30 minute.

Fire Performance of Structural Lightweight Aggregate Concrete using PP fiber (PP섬유 혼입 고강도 경량골재콘크리트의 내화특성)

  • Song, Hun;Chu, Yong-Sik;Lee, Jong-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.797-800
    • /
    • 2006
  • Normally, Structural light-weight aggregate concrete(LWC) has been main used in high rise building with the object of wight loss. In spite of LWC have the advantage of light-weight, limit the use of strength restrictions by reason that explosive spalling in fire. Especially, LWC is occurred serious fire performance deterioration by explosive spalling. Thus, this study is concerned with fire performance of LWC for the purpose of using PP fibers prevent to explosive spalling. From the experimental test result, LWC is happened explosive spalling.

  • PDF

A Study on the Effects of Fire-Resistant Coating Materials for Prevention of Concrete Spalling (콘크리트 폭렬 저감에 대한 내화 피복재의 영향에 관한 연구)

  • Jeong, Eui-Dam;Song, Myong-Shin;Kang, Hyun-Ju;Kang, Seung-Min
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.5
    • /
    • pp.9-15
    • /
    • 2010
  • Recently, the high-compressive strength concrete where the use is extending was weak in fire because of spalling that was occurring with rise of internal vapor pressure by high temperature. For preventing spalling of high-strength concrete in fire, Organic fibers have been using in concrete generally. By melting of organic fibers in concrete in fire, the internal moistures of concrete moves quickly to the outside, and so, preventing of spalling of high-strength concrete. But this method will be able to prevent the spalling of high-strength concrete, but makes the decrease of the concrete strength after fire. This study make a comparison between properties of preventing of spalling and remaining compressive strength of concrete using intumescence Alkali-Silicates fire-resistant material and that of concrete with organic fibers. Using organic fibers for preventing of spalling of concrete are P.P and Nylon fibers, and anti-fire intumescence material for protection of concrete surface is alkali-silicate materials. Fire resistance test executed as long as 3 hr under the flame temperature $1,200^{\circ}C$ over. In the case of concrete with P.P fibers, don't occurred the spalling, but the remaining compressive strength will not be able to measure, the concrete using intumescence Alkali-Silicates system fire-resistant material is not only preventing of the spalling but also the remaining compressive strength maintained until the maximum 96%.

Spalling Properties of High Strength Concrete Mixed with Various Mineral Admixtures Subjected to Fire

  • Han, Cheon-Goo;Han, Min-Cheol;Heo, Young-Sun
    • International Journal of Concrete Structures and Materials
    • /
    • v.2 no.1
    • /
    • pp.41-48
    • /
    • 2008
  • This study investigates the spalling properties of high strength concrete designed with various types of mineral admixture and diverse content ratios of polypropylene (PP) fiber. Experimental factors considered in series I are four pozzolan types of mineral admixture and series II consists of three shrinkage reducing types of mineral admixture. PP fiber was added 0.05, 0.10 and 0.15vol. % in each mixture of series I and series II, so that totally 27 specimens including control concretes in each series were prepared. Test results showed that the increase of fiber content decreased the slump flow of fresh concrete and increased or decreased the air content depending on the declining ratio of slump flow. For the properties of compressive strength, all specimens were indicated at around 50 MPa, which is high strength range; especially all specimens in series II were 60 MPa. Fire test was conducted in standard heating curve of ISO 834 with ${\phi}100{\times}200\;mm$ size of cylinder moulds for 1 hour. The specimens incorporating silica fume exhibited severe spalling and most specimens without the silica fume could be protected from the spalling occurrence in only 0.05vol % of PP fiber content. This fire test results demonstrated that the spalling occurrence in high strength concrete was not only affected by concrete strength related to the porosity of microstructure but also, even more influenced by micro pore structure induced by the mineral admixtures.

A Review on Spalling Phenomenon of High Strength Concrete during a Fire Accident (화재시 고강도 콘크리트의 폭열현상에 관한 고찰)

  • Kim, Hyung-Doo
    • Fire Science and Engineering
    • /
    • v.20 no.2 s.62
    • /
    • pp.80-86
    • /
    • 2006
  • This study focuses on spalling phenomenon which is the one of the main issues of high strength concrete. The definition, classification and characterization, causes and the reaction mechanism of the spalling were investigated on the basis of previous literatures. The spalling phenomenon occurs when several factors such as sharp temperature increase, high water content, low water/cement ratio and local stress concentration in material combine in the concrete material. On the basis o f the factors, the preventing methods from the spalling are known as decrease of temperature increase, preventing of concrete fragmentation and fast drying of internal moisture. In this study, the controlling method of water content below some critical value was proposed as the most effective spalling-preventing method among the spalling-preventing methods. The spalling phenomenon can be prevented by adjusting the water content in the high strength concrete. Therefore, an enforced drying method is needed to decrease the water content below a critical value. Additional experimental data should be generated to determine the critical value of water content for preventing the spalling.

A Case Study on the Field Construction of Spalling Resistance Method of High Performance Concrete (고성능 콘크리트의 폭렬방지 공법 시공사례)

  • Kim, Kyoung-Min;Heo, Young-Sun;Lee, Jae-Sam;Jee, Suk-Won;Lee, Seong-Yeun;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.610-613
    • /
    • 2006
  • This paper is the fundamental study for manufacture of spalling resistance concrete and also analyses the mechanism and spalling resistance method with materials, mixture proportion and lateral confinement. The present work with the basic experiment achieved successful method for spalling resistance using both proper amounts of fiber contents and lateral confinement using metal lath. Moreover, the developed spalling resistance method was applied for full sized column construction in the Doosan We've Poseidon I field, located in Busan city. Authors investigated the physical properties examining workability, placeability and pumpability. These studies are continuously processing to develop new technology expecting remarkable impact on the spalling resistance and fire resistance performance of high-raise building construction in the future.

  • PDF

Performance of fire damaged steel reinforced high strength concrete (SRHSC) columns

  • Choi, Eun Gyu;Kim, Hee Sun;Shin, Yeong Soo
    • Steel and Composite Structures
    • /
    • v.13 no.6
    • /
    • pp.521-537
    • /
    • 2012
  • In this study, an experimental study is performed to understand the effect of spalling on the structural behavior of fire damaged steel reinforced high strength concrete (SRHSC) columns, and the test results of temperature distributions and the displacements at elevated temperature are analyzed. Toward this goal, three long columns are tested to investigate the effect of various test parameters on structural behavior during the fire, and twelve short columns are tested to investigate residual strength and stiffness after the fire. The test parameters are mixture ratios of polypropylene fiber (0 and 0.1 vol.%), magnitudes of applied loads (concentric loads and eccentric loads), and the time period of exposure to fire (0, 30, 60 and 90 minutes). The experimental results show that there is significant effect of loading on the structural behaviors of columns under fire. The loaded concrete columns result more explosive spalling than the unloaded columns under fire. In particular, eccentrically loaded columns are severely spalled. The temperature distributions of the concrete are not affected by the loading state if there is no spalling. However, the loading state affects the temperature distributions when there is spalling occurred. In addition, it is found that polypropylene fiber prevents spalling of both loaded and unloaded columns under fire. From these experimental findings, an equation of predicting residual load capacity of the fire damaged column is proposed.

Fire Loading Analysis of Underground Box Structure with Considering of Concrete Spalling I : Spalling Analysis (박리를 고려한 지하박스구조물의 화재하중해석 I : 박리해석)

  • Lee, Gye-Hee;Choi, Ik-Chang
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.4
    • /
    • pp.477-483
    • /
    • 2007
  • In this study, the numerical fire analysis for temperature distribution and spalling behavior of underground concrete box structures that contained lifelines, such as power cables and communication cables. The temperature field of inner space was assumed based on the fire curve with the thermal gradient obtained from CFD analysis. It was assumed that the spalling behaviors of concrete are occurred when the concrete temperature reached the threshold, as dehydration degree. In this case, the elements correspond to spalling parts were removed and the analysis model were updated. Three fire scenarios were analyzed and the results were showed adequate spalling behavior. The bearing capacities of the box structures would be estimated in the companion paper.

Spalling of Concrete with Compressive strength and heating rates (압축강도 및 가열속도에 따른 콘크리트의 폭렬성상)

  • Choe, Gyeong-Choel;Kim, Gyu-Yong;Yoon, Min-Ho;Lee, Young-Wook;Hwang, Ui-Chul;Yoo, Jae-Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.43-44
    • /
    • 2015
  • In this study, spalling property were evaluated from concrete with compressive strengths of 30MPa, 90MPa, 180MPa, applied with fast heating condition(ISO-834 standard heating curve) and slow heatign condition(1℃/min). As a result, the spalling property of concrete was shown differently with compressive and heatign rate. And It could be separated three as non spalling, surface spalling and explosive spalling.

  • PDF