• 제목/요약/키워드: concrete slabs

검색결과 801건 처리시간 0.024초

고강도 콘크리트를 적용한 RC 바닥판의 정적 성능 평가 (Evaluation of Structural Performance of RC Deck Slabs by High-Strength Concrete)

  • 배재현;황훈희;박성용;조근희
    • 한국안전학회지
    • /
    • 제31권3호
    • /
    • pp.89-95
    • /
    • 2016
  • Lately, the high-strength concrete is often used to increase the lifespan of bridges. The benefits of using the high-strength concrete are that it increases the durability and strength. On the contrary, it reduces the cross-section of the bridges. This study conducted structural performance tests of the bridge deck slabs applying high-strength concrete. As result of the tests, specimens of bridge deck slabs were destroyed through punching shear. Moreover, the tests exposed that the high-strength concrete bridge deck slabs satisfy the flexural strength and the punching shear strength at ultimate limit state(ULS). Also, limiting deflection of the concrete fulfilled serviceability limit state(SLS) criteria. These results indicated that the bridge deck slabs designed by high-strength concrete were enough to secure the safety factor despite of its low thickness.

Behavior of lightweight aggregate concrete voided slabs

  • Adel A. Al-Azzawi;Ali O, AL-Khaleel
    • Computers and Concrete
    • /
    • 제32권4호
    • /
    • pp.351-363
    • /
    • 2023
  • Reducing the self-weight of reinforced concrete structures problem is discussed in this paper by using two types of self-weight reduction, the first is by using lightweight coarse aggregate (crushed brick) and the second is by using styropor block. Experimental and Numerical studies are conducted on (LWAC) lightweight aggregate reinforced concrete slabs, having styropor blocks with various sizes of blocks and the ratio of shear span to the effective depth (a/d). The experimental part included testing eleven lightweight concrete one-way simply supported slabs, comprising three as reference slabs (solid slabs) and eight as styropor block slabs (SBS) with a total reduction in cross-sectional area of (43.3% and 49.7%) were considered. The holes were formed by placing styropor at the ineffective concrete zones in resisting the tensile stresses. The length, width, and thickness of specimen dimensions were 1.1 m, 0.6 m, and 0.12 m respectively, except one specimen had a depth of 85 mm (which has a cross-sectional area equal to styropor block slab with a weight reduction of 49.7%). Two shear spans to effective depth ratios (a/d) of (3.125) for load case (A) and (a/d) of (2) for load case (B), (two-line monotonic loads) are considered. The test results showed under loading cases A and B (using minimum shear reinforcement and the reduction in cross-sectional area of styropor block slab by 29.1%) caused an increase in strength capacity by 60.4% and 54.6 % compared to the lightweight reference slab. Also, the best percentage of reduction in cross-sectional area is found to be 49.7%. Numerically, the computer program named (ANSYS) was used to study the behavior of these reinforced concrete slabs by using the finite element method. The results show acceptable agreement with the experimental test results. The average difference between experimental and numerical results is found to be (11.06%) in ultimate strength and (5.33%) in ultimate deflection.

할로우코어 슬래브의 내화성능에 대한 수치해석 연구 (Numerical Study on Fire Performance of Hollowcore Slabs)

  • 민정기;우영제
    • 한국공간구조학회논문집
    • /
    • 제15권3호
    • /
    • pp.95-102
    • /
    • 2015
  • Numerical model on precast prestressed concrete (PC) hollowcore slabs using 11.3 mm diameter 7-wire stand was developed based on finite element analysis. In order to validate the modelling, previous experiment results with respect to prestressed solid concrete slabs were used and compared throughout the course of fire exposure. In addition to, the fire performance of hollowcore slabs with different aggregate types, moisture contents and compressive strength of concrete was investigated. As a result, it can be seen that the type of aggregates and moisture contents used in hollowcore slabs can affect the fire performance as well as temperature developments.

Experimental Study on Strengthening Transverse Joints between Precast Concrete Slabs

  • Park, Jong-Jin;Cheung, Jin-Hwan;Shin, Su-Bong
    • KCI Concrete Journal
    • /
    • 제12권2호
    • /
    • pp.45-54
    • /
    • 2000
  • Precast R.C. slabs are being used widely for the construction of bridge structures due to their simplicity in construction processes. However, one of the disadvantages in precast R.C. slabs is the existence of transverse joints between two precast slabs. The transverse joints are structurally fragile and the task of strengthening the joints is difficult one due to their structural discontinuity. The aim of this study was to improve the behavior of transverse joints between precast R.C. slabs by introducing prestress with external cables. Three steel-concrete composite bridge specimens, which were prestressed with the external cables anchored on steel girders, were fabricated in the laboratory. Both pretension and post-tension methods were applied to introduce prestressing on the concrete slab with a straight tendon arrangement. Static tests were conducted at service load and ultimate load test was performed to evaluate punching shear capacity of the transverse joint. In this paper, two prestressing methods were tested and their effects were evaluated with respect to the elastic behavior and ultimate loading capacity of the transverse joints.

  • PDF

Three-dimensional finite element analysis of reinforced concrete slabs strengthened with epoxy-bonded steel plates

  • Metwally, Ibrahim M.
    • Advances in concrete construction
    • /
    • 제2권2호
    • /
    • pp.91-108
    • /
    • 2014
  • This paper presents a nonlinear finite element analysis (FEA) in order to investigate the flexural performance of one-way slabs strengthened by epoxy-bonded steel plates. Four point loading scheme is selectively chosen. A model is developed to implement the material constitutive relationships and non-linearity. Five Slabs were modeled in FEM software using ABAQUS. One slab was unstrengthened control slab and the others were strengthened with steel plates with varying the plate thickness and configuration. In order to verify the accuracy of the numerical model, a comparison was done between the experimental results available in the literature and the proposed equations by ACI 318-11 for the calculation of ultimate load capacities of strengthened slabs, the agreement has proven to be good and FEA attained accurate results compared with ACI code. A parametric study was also carried out to investigate the influence of thickness of steel plate, strength of epoxy layer and type of strengthening plate on the performance of plated slabs. Also, the practical and technical feasibility of splitting the steel plate in strengthening process has been taken into account. For practical use, the author recommended to use bonded steel plate as one unit rather than splitting it to parts, because this saves more effort and reduces the risk of execution errors as in the case of multiple bonded parts. Both techniques have nearly the same effect upon the performance of strengthened slabs.

Optimal sensor placement of retrofitted concrete slabs with nanoparticle strips using novel DECOMAC approach

  • Ali Faghfouri;Hamidreza Vosoughifar;Seyedehzeinab Hosseininejad
    • Smart Structures and Systems
    • /
    • 제31권6호
    • /
    • pp.545-559
    • /
    • 2023
  • Nanoparticle strips (NPS) are widely used as external reinforcers for two-way reinforced concrete slabs. However, the Structural Health Monitoring (SHM) of these slabs is a very important issue and was evaluated in this study. This study has been done analytically and numerically to optimize the placement of sensors. The properties of slabs and carbon nanotubes as composite sheets were considered isotopic and orthotropic, respectively. The nonlinear Finite Element Method (FEM) approach and suitable optimal placement of sensor approach were developed as a new MATLAB toolbox called DECOMAC by the authors of this paper. The Suitable multi-objective function was considered in optimized processes based on distributed ECOMAC method. Some common concrete slabs in construction with different aspect ratios were considered as case studies. The dimension and distance of nano strips in retrofitting process were selected according to building codes. The results of Optimal Sensor Placement (OSP) by DECOMAC algorithm on un-retrofitted and retrofitted slabs were compared. The statistical analysis according to the Mann-Whitney criteria shows that there is a significant difference between them (mean P-value = 0.61).

도로교 콘크리트 바닥판의 합리적인 수명 평가 및 예측시스템 개발 (Development of Probabilistic Prediction System for Remaining Life of Reinforced Concrete Bridge Decks)

  • 오병환;최영철;이준혁
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.637-640
    • /
    • 2002
  • The deterioration of RC deck slabs has been a serious problem and high portion of budget has been a spent for repair and strengthening of deck slab. The concrete deck slabs are subject to direct application of vehicle loading and accumulation of fatigue damage. Besides, various environmental causes. In this paper, an probabilistic study is carried out to predict exact load effects and structural capacity of deck slab during its service life, and estimate an appropriate remaining life of deck slab. To achieve this purpose the live load model is developed using by influence line including deterioration of deck slab, and deterioration model of bridge deck slab is developed. In addition, the fatigue life of reinforced concrete deck slabs considering corrosion of reinforcement are estimated based on experimental formula. This study will help rational decisions for the management and repair of reinforced concrete deck slabs.

  • PDF

Long-term flexural cracking control of reinforced self-compacting concrete one way slabs with and without fibres

  • Aslani, Farhad;Nejadi, Shami;Samali, Bijan
    • Computers and Concrete
    • /
    • 제14권4호
    • /
    • pp.419-444
    • /
    • 2014
  • In this study experimental result of a total of eight SCC and FRSCC slabs with the same cross-section were monitored for up to 240 days to measure the time-dependent development of cracking and deformations under service loads are presented. For this purpose, four SCC mixes are considered in the test program. This study aimed to compare SCC and FRSCC experimental results with conventional concrete experimental results. The steel strains within the high moment regions, the concrete surface strains at the tensile steel level, deflection at the mid-span, crack widths and crack spacing were recorded throughout the testing period. Experimental results show that hybrid fibre reinforced SCC slabs demonstrated minimum instantaneous and time-dependent crack widths and steel fibre reinforced SCC slabs presented minimum final deflection.

Strengthening of Cutouts in Existing One-Way Spanning R. C. Flat Slabs Using CFRP Sheets

  • Shehab, Hamdy K.;Eisa, Ahmed S.;El-Awady, Kareem A.
    • International Journal of Concrete Structures and Materials
    • /
    • 제11권2호
    • /
    • pp.327-341
    • /
    • 2017
  • Openings in slabs are usually required for many different applications such as aeriation ducts and air conditioning. Opening in concrete slabs due to cutouts significantly decrease the member stiffness. There are different techniques to strengthen slabs with opening cutouts. This study presents experimental and numerical investigations on the use of Carbon Fiber Reinforced Polymers (CFRP) as strengthening material to strengthen and restore the load carrying capacity of R.C. slabs after having cutout in the hogging moment region. The experimental program consisted of testing five (oneway spanning R.C. flat slabs) with overhang. All slabs were prismatic, rectangular in cross-section and nominally 2000 mm long, 1000 mm width, and 100 mm thickness with a clear span (distance between supports) of 1200 mm and the overhang length is 700 mm. All slabs were loaded up to 30 kN (45% of ultimate load for reference slab, before yielding of the longitudinal reinforcement), then the load was kept constant during cutting concrete and steel bars (producing cut out). After that operation, slabs were loaded till failure. An analytical study using finite element analysis (FEA) is performed using the commercial software ANSYS. The FEA has been validated and calibrated using the experimental results. The FE model was found to be in a good agreement with the experimental results. The investigated key parameters were slab aspect ratio for the opening ratios of [1:1, 2:1], CFRP layers and the laminates widths, positions for cutouts and the CFRP configurations around cutouts.

활절점으로 연결된 철근콘크리트 슬래브 내력에 기존 슬래브 철근이 미치는 영향 (Effection of The Existing Reinforcement on The Strength of Reinforced Concrete Slabs Connected by Hinged Jointeds)

  • 심규관;김상식;최광호;임주혁;이정윤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.271-274
    • /
    • 2005
  • In this research, 13 RC slabs connected by hinged joints were tested. the new slab was connected to the existing slab by hinge joint injecting dowel bars between two slabs. Main parameters of the slabs were the spacing of the dowel bars (150mm, 300mm, and 450mm) and the locations of the longitudinal reinforcement of the old slab. The test results indicated that the joint strength of the RC test slabs having various types of dowel bars was about twice that calculated by the ACI 318-02 code. The locations of the longitudinal reinforcement of the old slab slightly increased the strength of the slabs connected by hinged joints.

  • PDF