1 |
Tan, K. H., & Zhao, H. (2004). Strengthening of openings in one-way reinforced-concrete slabs using carbon fiber-reinforced polymer systems. J Compos Constr, 8(5), 393-402.
DOI
|
2 |
Vasquez, A., & Karbhari, V. M. (2003). Fiber-reinforced polymer composite strengthening of concrete slabs with cutouts. ACI Struct J, 100(5), 665-667.
|
3 |
ACI 318-14, "Building Code Requirements for Structural Concrete and Commentary", American Concrete Institute, Farmington Hills, Michigan, February, 68 pp.
|
4 |
ANSYS. (2011). Release 14.0 documentation. ANSYS Inc. http://www.ansys.com
|
5 |
Muhammed, N. (2012). Experimental study of self compacting RC slabs with opening strengthening with carbon fiber laminated and steel fiber. Journal of Engineering and Development, 16(1), March 2012 ISSN 1813-7822.
|
6 |
Casadei, P., Nanni, A., & Ibell, T. J. (2003). Experiments on two-way RC slabs with openings strengthened with CFRP laminates. In Proceedings of advancing with composites, PLAST 2003. Milan, Italy, Conference 7-9 May, Conference 2003.
|
7 |
Enochsson, O., Lundqvist, J., Taljsten, B., Rusinowski, P., & Olofsson, T. (2007). CFRP strengthened openings in two-way concrete slabs-An experimental and numerical study. Construction and Building Materials, 21(4), 810-826.
DOI
|
8 |
Khajehdehia, R., & Panahshahib, N. (2016). Effect of openings on in-plane structural behavior of reinforced concrete floor slabs. Journal of Building Engineering, 7, 1-11
|
9 |
Mosallam, A. S., & Mosalam, K. M. (2003). Strengthening of two-way concrete slabs with FRP composite laminates. Construction and Building Materials, 17, 43-54.
DOI
|
10 |
Mota, M. C., & Kamara, M. (2006). Floor openings in two-way slabs. Concrete Int., 28(7), 33-36.
|
11 |
Ozgur, A., Nalan, K., & Onur, A. (2013). Strengthening of one way RC slab with opening using CFRP strips. Construction and Building Materials, 48(10), 883-893.
DOI
|
12 |
Smith, S. T., & Kim, S. J. (2009). Strengthening of one-way spanning RC slabs with cutouts using FRP composites. Construction and Building Materials, 23, 1578-1590.
DOI
|
13 |
Song, J. K., Kim, J., Song, H. B., & Song, J. W. (2012). Effective punching shear and moment capacity of flat plate-column connection with shear reinforcements for lateral loading. International Journal of Concrete Structures and Materials., 6(1), 19-29.
DOI
|
14 |
Sorin-Codrut, F., Sas, G., Popescu, C., & Stoian, V. (2015). Tests on reinforced concrete slabs with cut-out openings strengthened with fibre-reinforced polymers. Composites: Part B, 66, 484-493.
|