• Title/Summary/Keyword: concrete quality

Search Result 2,018, Processing Time 0.042 seconds

A Proposal for Improving the Measurement and Management of Unit Water Content in In-Situ Concrete (현장 타설 콘크리트의 단위수량 측정 및 관리 개선 방안 제시)

  • Yun, Ja-yeon;Jang, Hyo-Jun;Lee, Taegyu;Choi, Hyeonggil
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.3
    • /
    • pp.319-329
    • /
    • 2024
  • This study examined domestic and international regulations concerning concrete unit weight, along with an evaluation of unit weight in concrete poured on construction sites. Fluctuations in unit weight were observed to correlate with concrete quality issues such as material separation, bleeding, and latency. A word cloud analysis, centered on the concept of concrete quality, further highlighted the significant influence of unit weight. Comparative analysis between Korea and Japan revealed few substantial differences in unit weight management and measurement techniques. However, calculation of concrete unit weight at delivery, using the unit volume mass method, indicated considerable variability among random on-site samples. Notably, the unit weight often exceeded the recommended standard. These findings emphasize the necessity for strict adherence to unit weight standards by all stakeholders involved in concrete production and construction, including ready-mix concrete (REMICON) producers, construction firms, and inspectors. To ensure consistent quality of cast concrete on-site, the establishment of a more comprehensive and practical system is recommended, incorporating measures such as on-site inspections.

Preparation and Water Quality Purification of Permeable Concrete Pavement Filled with Microbial-Soil Sheet (미생물토양시트를 충진한 도로포장용 다공성 콘크리트의 제조 및 수질정화특성)

  • Kang, Young-Heoun;Hwang, Pil-Gi;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.6
    • /
    • pp.727-733
    • /
    • 2009
  • This study was performed to investigate the physical characteristics like compressive strength, permeability, porosity and the water quality removal characteristics of permeable concrete pavement filled with microbial-soil sheet to remove SS, organic matter and nutrients in artificial rainfall. As a result, it can show the removal efficiency is SS 90~95%, COD 85~93%, BOD 80~83%, T-N 61~75%, T-P 71~78% on WAPS I(W1) and WAPS II(W2). Therefore, permeable concrete pavement filled with microbial-soil sheet shows higher removal efficiency(SS 10%, organic matter and nutrients 30%) than a conventional porous concrete(W3). By filling microbial-soil sheet to permeable concrete pavement, we confirm that the function and efficiency are improved significantly and that a naturally-friendly facility can be developed and applied to treat non-point sources.

Influence of Aggregate on the Rebound Value of P Type Schmidt Hammer (P형 슈미트햄머의 반발도에 미치는 골재종류의 영향)

  • 김태현;김기정;이용성;이백수;윤기원;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.239-242
    • /
    • 2002
  • This study is intended to investigate the relationship between rebound value of P type schmidt hammer and the compressive strength with various aggregates, and a series of experiments about early strength quality control by P type schmidt hammer was performed. According to the results, the compressive strength of concrete using basalt and limestone aggregate is higher by 3% and lower by 4% than that of concrete using granite aggregate respectively. Concrete using basalt and lime stone aggregate show high rebound value in vertical strike. Estimation of the compressive strength does not show differences in horizontal strike, but the compressive strength is estimated high in order of granite, basalt and limestone aggregate in vertical strike. A good correlation between the rebound value of schmidt hammer and the compressive strength is confirmed regardless of aggregate types, so it could be possible to control the quality of concrete by P type schmidt hammer test when basalt and limestone aggregates are used at the same time.

  • PDF

The Test Methodological Effects on the Flexural Toughness of Steel Fiber Reinforced Concrete (강섬유보강 콘크리트의 휨인성에 영향을 미치는 실험방법적 요인)

  • 한승환;이형준;오병환;조재열
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10a
    • /
    • pp.380-385
    • /
    • 1998
  • Nowadays, shotcrete plays an essential part in he construction of underground structures, and steel fiber is so useful for increasing the toughness of the concrete that is spotlighted at tunnel or pavement site. A variety of tests have been developed to measure and quantity the improvements achievable in steel fiber reinforced concrete(SFRC) and shotcrete. But Korea doesn`t have specific standards in this respect, and the only criteria that KHC(Korea Highway Corporation) applies to tunnel shotcreting are flexural strength and toughness quotient. Test results in order to manage the quality of steel fiber reinforced concrete and shocrete are very affected by various test method. Therefore, this study deals with the test methodological effects on SFRC quality. The major interests are loading method, that is, load control and displacement control, loading velocity, support condition.

  • PDF

Application on Concrete using Artificial Aggregate with Paper Sludge Ash (제지 슬러지 소각회 인공골재의 콘크리트에의 적용)

  • 문경주;백명종;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10c
    • /
    • pp.173-178
    • /
    • 1998
  • This study is described the experimental result of the development of artificial aggregate using paper sludge ash and the application of it in concrete. Artificial aggregates are prepared with crushed stone in the variety aspect. Therefore, Quality properties of artificial aggregate using paper sludge ash are fairly corresponded with it of crushed stone. For the application of artificial aggregate using paper sludge ash in concrete, Coarse aggregates are replaced with artificial aggregate using paper sludge ash in the constant of volume(0%, 30%, 70%, 100%). It is conclued from the test results that the artificial aggregate using paper sludge ash could be used replacement of coarse aggregate in concrete. Continuous study should be planned for improvement of it's quality.

  • PDF

Application of Waste Foundry Sand to Concrete-Based Product Having Low Water Cement Ratio (낮은 W/C비를 갖는 콘크리트 제품에 대한 폐주물사의 적용)

  • 이대경;김동주;조홍준;김진만
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.79-84
    • /
    • 2001
  • Because the WFS(Waste Foundry Sand), by-product of a casting factory, is generally a smaller particle than a fine aggregate, it has a bad influence on quality of concrete. Especially, the grading of aggregate is a very important factor in the case of concrete-based products having low water cement ratio manufactured by vibration and pressing method. Therefore, it is necessary to use WFS with the suitable grading of aggregate that it don't has a bad Influence on the quality of concrete-based products. This study investigated the suitable using proportion of WFS by means of the composition method of aggregate suggested by Driscoll. The results showed that it was desirable to use 10% of WFS since higher strength was developed with that amount.

  • PDF

Development and Performance Evaluation of Floor Level Joint System (다목적 바닥 레벨조인트 공법의 개발 및 성능평가에 관한 연구)

  • 최윤철;서수연;지남용;이리형
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.953-958
    • /
    • 2002
  • The finishing method of concrete floor using automatic surface finisher is one of new technologies in concrete floor construction. The development of high technologies in construction will increase in order to satisfy the demand to construct high quality building. Using this method, it is possible to increase the quality of building as well as to reduce the labor work in site. In this paper, a system which can be used to finish the concrete floor using automatic surface finisher, is presented and its structural capacities are evaluated. The system is composed of rail which guides the surface vibrator and absorbs the volume change of concrete, and a device supporting the rail. From the experimental work for these devices, it was shown that the support and rail had suitable strength to resist the automatic surface finisher. For design purpose, also, effective span of supports was tabulated.

  • PDF

A Study on a Performance evaluation for Quality Liguid Siliceous of waterproof agent using on the concrete Structure (콘크리트구조물에 적용하는 액상형 규산질계 침투성 방수재의 성능평가에 관한 연구)

  • Kang Hyo Jin;Kwon Shi-Won;Oh Sang-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.184-187
    • /
    • 2004
  • There are many factors that generate the early deterioration of the concrete structure. As the one of the representative factors, we can think an invasion of the water, air and so on. The water and air invade in inside void along the capillarity and they become the cause that the durability like corrosion of layer department due to freezing and thawing, inside steel frame corrosion, and so on blacks. Therefore with covering permeability covering waterproofing material of fluid condition in outer wall, intercepting the deterioration factor due to the infiltration of water from outside and for salt damage of concrete layer department, freezing damage and neutralization, it needs to improve durability of structure. This study separately examined physical and chemical specific of quality liguid siliceous of waterproofing material. Therefore as this applys the construction site, it improves the durability of concrete structure. Further this presents the application plan from the construction market against the new material.

  • PDF

The Study on the design of durability of Concrete in Agricultural Hydraulic Structures (농업용 수리구조물의 내구성 설계방안 연구)

  • Park Kwang Su;Kim Meyong Won;Kim Kwan Ho;Lee Joon Gu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.830-833
    • /
    • 2004
  • Hydraulic structures have been constructed with low cost concrete so as to increase the investment efficiency. But, it has caused to produce structures having excess internal voids inside concrete. As the construction of agricultural irrigation and drainage project is concentrated on off-farming season and scattered in wider area, variation of quality of structures is big and it caused increase of internal voids. Due to that reason, hazardous substance is passing rather freely through the voids causing occur of crack and accordingly life time of structures is getting shortened. It is necessary to make a thesis of design criteria for design strength to increase life time, range of variation of quality, strength of ready-mixed concrete proper to design strength, and water-cement ratio and air content.

  • PDF

A Field Study on the Mass Concreting in Cold Weather Environment (매스콘크리트의 한중시공에 관한 현장실험연구)

  • 한민철;김현우;김성수;최강순;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.287-292
    • /
    • 1999
  • Mass concreting in cold weather environment should be focused on the control of thermal crack caused by high hydration heat rather than curing method for protecting from frost damage at early age because the thermal stress have much influence on the quality of structure placed in cold weather. Therefore, in this paper, the control of thermal crack of mass concrete in cold weather environment are dealt with preparing the practice plan for mass concrete and placing the concrete according to the plactice plan. According to the results, we can obtain good quality mass concrete without thermal crack caused by the difference of temperature between inner part and outer part.

  • PDF