• 제목/요약/키워드: concrete mix

검색결과 1,199건 처리시간 0.027초

인천 LNG 지하탱크 #219 Bottom Slab시공 및 온도균열 안정성 평가 (Construction and Evaluation of Thermal Crack Stability about Bottom Slab of the #219 LNG Underground Tank in Incheon)

  • 손영준;하재담;엄태선;이종열;박종식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.689-692
    • /
    • 2006
  • The crack of concrete induced by the heat of hydration is a serious problem, particularly in massive concrete structures. In order to control the temperature crack of massive concrete, the selection of appropriate materials like low heat cement, mixture materials, etc. is essential. In tills study, mix proportion using low heat portland cement and lime stone powder was designed and the best mix proportion, B-1, was selected. When bottom slab of the #219 LNG tank in Incheon was constructed, concrete temperature was measured. And thermal stress was analyzed about bottom slab of the LNG tank. As results of the thermal analysis, crack index was 1.60 in bottom slab and satisfied with construction specifications(over 1.0).

  • PDF

시멘트콘크리트 포장체의 거동연구를 위한 축소모델 배합의 재료적 상사성 (The Similitude of Material for Small-Scale Model Mix Proportion of Concrete Pavement)

  • 고영주;이용우;배주성
    • 콘크리트학회지
    • /
    • 제11권2호
    • /
    • pp.139-145
    • /
    • 1999
  • 본 연구는 시멘트콘크리트 포장체의 거동연구를 위한 축소모형실험에 앞서 모형시험체의 제작에 가장 중요한 변수인 재료적 상사성을 확보하기 위한 방법론을 기술하였다. 현재 고속도로의 콘크리트 포장 배합설계기준과 동일한 배합비로 제작한 시험편과 골재의 최대치수를 축소하고 W/Cm C/a, S/a, 골재종류를 변수로 하여 총 224개의 원형공시체를 제작하여 그들의 응력-변형률 거동을 분석하므로써 재료적 상사성을 만족하는 모형배합비를 도출하였다. 모형콘크리트 배합비로 쇄석은 C/a 31%에서 S/a 28%, 강자갈은 C/a 30%일 때 S/a 27%가 가장 적합한 것으로 나타났다. 이는 실내 모형실험에 의해 콘크리트포장체의 거동연구를 하고자 할때 모형실험에 대한 신뢰성을 향상시키고, 향후 연구의 기초자료를 제공할 수 있으리라 판단된다.

Investigation of steel fiber effects on concrete abrasion resistance

  • Mansouri, Iman;Shahheidari, Farzaneh Sadat;Hashemi, Seyyed Mohammad Ali;Farzampour, Alireza
    • Advances in concrete construction
    • /
    • 제9권4호
    • /
    • pp.367-374
    • /
    • 2020
  • Concrete surfaces, industrial floors, sidewalks, roads and parking lots are typically subjected to abrasions. Many studies indicated that the abrasion resistance is directly related to the ultimate strength of the cured concrete. Chemical reactions, freeze-thaw cycles, and damages under abrasion are among many factors negatively affecting the concrete strength and durability. One of the major solutions to address the abrasive resistance of the concrete is to use fibers. Fibers are used in the concrete mix to improve the mechanical properties, strength and limit the crack propagations. In this study, implementation of the steel fibers in concrete to enhance the abrasive resistance of the concrete is investigated in details. The abrasive resistance of the concrete with and without steel fibers is studied with the sandblasting technique. For this purpose, different concrete samples are made with various hooked steel fiber ratios and investigated with the sandblasting method for two different strike angles. In total, 144 ASTM verified cube samples are investigated and it is shown that those samples with the highest steel fiber ratios have the highest abrasive resistance. In addition, the experiments determine that there is a meaningful correlation between the steel fiber percentage in the mix, strike angle and curing time which could be considered for improving structural behavior of the fiber-reinforced concrete.

석탄 가스화 복합발전(IGCC) 슬래그잔골재의 PHC파일 성형성 및 배합특성에 관한 연구 (The Study on Moldability and Mix Characteristic of IGCC Slag Aggregate as PHC-Pile)

  • 박용규;고효진;윤기원
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.273-274
    • /
    • 2018
  • When IGCC Slag(CGS) aggregate was used as PHC-Pile, the moldability was lowered as the mixing ratio increased. concrete mix design. Also the mix characteristics increased the use of AD depending on the usage rate, however, require detailed consideration.

  • PDF

소입경 골재노출콘크리트포장의 최적 배합 및 노출기법에 관한 연구 (A Study on the Optimum Mix and Exposing Method of the Fine-Size Exposed Aggregate PCC Pavements)

  • 김영규;이승우;유태석;김형배
    • 한국도로학회논문집
    • /
    • 제11권2호
    • /
    • pp.1-15
    • /
    • 2009
  • 골재노출콘크리트포장은 콘크리트 타설 직후 포장표면에 응결지연제를 살포하여 표면으로부터 깊이 2$\sim$3mm 정도의 모르타르 경화를 늦추게 한 후 표면의 모르타르 제거를 통해 굵은골재를 포장표면에 노출시키는 공법이다. 골재노출콘크리트포장의 타이어-노면 소음이 일반 콘크리트포장보다 작으면서도 적정한 미끄럼저항을 장기간 유지한다는 장점을 가지고 있다. 특히 굵은골재가 소입경일수록 소음저감효과가 우수한 것으로 알려져 있다. 성공적인 소입경 골재노출콘크리트포장의 건설을 위해서는 굵은골재의 최대입경이 적정하여야 하며, 적정량의 굵은골재를 포장표면에 균일하게 노출하도록 해야 하며 이를 위한 적절한 배합과 노출기법의 도출이 요구된다. 일반적인 콘크리트포장의 배합기준은 강도설계로 이루어지지만 소입경 골재노출콘크리트포장의 경우 강도뿐만 아니라 소음저감효과, 미끄럼저항을 적절히 발현시킬 수 있는 배합설계를 실시하기 위해서는 강도실험 외에도 노면의 미끄럼저항, 소음을 고려할 필요가 있다. 본 연구에서는 소입경 골재노출콘크리트포장에 대하여 적정 강도를 유지하며 포장표면조직의 소음 저감효과 및 적정 미끄럼저항성을 동시에 만족시킬 수 있도록 표면조직을 형성할 수 있는 최적배합에 대해 제시하였다. 또한 콘크리트포장은 온도, 습도 및 대기환경에 의해 모르타르의 경화속도가 달라지므로 콘크리트의 물리적 성질을 정량적으로 고려한 최적 노출기법이 제시되었다.

  • PDF

콘크리트 배합요인별 상·하부 분리타설에 의한 수화열 균열지수 저감방안 및 현장적용 (Method of Decreasing Cracking Index by Different Mix Conditions for Separated Placement and its Field Application)

  • 김민호;한천구
    • 한국건설순환자원학회논문집
    • /
    • 제4권3호
    • /
    • pp.292-298
    • /
    • 2016
  • 본 연구에서는 매스 매트 콘크리트에 있어, 상 하부를 구분하여 타설하는 실무조건을 고려하여, 상부 및 하부배합의 혼화재 종류와 치환율을 동일 및 달리하는 배합 조건 변화로부터 최적치를 도출한 다음, 실구조체에 적용하여 해석치와 실측치간을 비교하므로서, 혼화재를 활용한 매스콘크리트의 효율적인 수화열균열 저감방안을 제안하고자 하였다. 연구결과 먼저, 현장적용 전 사전검토를 위해 Midas gen을 이용하여 수화열 해석을 실시한 결과 상부는 OPC : FA = 85 : 15 배합, 하부는 OPC : FA : BS = 50 : 20 : 30 배합을 본 대상 구조물 매스 매트콘크리트의 최적배합으로결정하였다. 이를 적용한 실제 현장의 시험결과 슬럼프, 공기량 및 압축강도는 모두 목표범위를 만족하였다. 또한, 봄철 실제 현장의 매스 매트콘크리트의 온도특성으로 최적배합의 경우는 중심부의 최고 온도 약 $59^{\circ}C$, 표층부 온도 약 $49^{\circ}C$로 나타나, 약 $10^{\circ}C$의 온도차가 나타났으며, 수화열 해석결과 약 1.4의 균열지수를 나타내었다. 따라서, 실무를 고려한 매스 매트콘크리트의 경우 상 하부 타설 콘크리트간의 저발열 배합정도를 달리 고려하는 수화발열량차 공법적용은 침하균열 방지 및 수화열 균열제어에 효과적인 방법이 될 것으로 사료된다.